Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹20.0 L+₹1.8 L (9.76%)Rejected-Finance RZG 205 RZG STREET NO 9 PALAM COLONY RAJ NAGAR PART 2 BAGDOLA SOUTH WEST DELHI DELHI 110077 | SOUTH WEST DELHI | DELHI | 110077 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹21.7 L+₹3.5 L (19.1%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹22.5 L+₹4.3 L (23.8%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹22.9 L+₹4.7 L (25.8%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SUBROTO PARK
GE (AF) Subroto Park, Delhi Cantt Delhi-110010
As described in Bill of quantities
2023_MES_598429_1
GE/SP/ TOKEN-39/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE (AF) SUBROTO PARK
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) SUBROTO PARK
₹80,000
Yes
28 Aug 2023
26 May 2023
1 Jul 2023
26 May 2023
23 Jun 2023
10 Jun 2023
Amount
Excavation in trenches in hard and dense soil n exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipe,foundation for poles, stay, laying cables etc and getting out complete all as directed by engineer-in-charge.
Returning filling in including spreading, leveling watering and well ramming in layers n. exc 25 cm in hard/dense soil complete all as directed by engineer-in-charge.
Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point complete all as directed by engineer-in-charge.
M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as directed by engineer-in-charge.
Supply and laying well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable complete all as directed by engineer-in-charge.
M&L for precast cement concrete block masonry with solid blocks,exceeding 10 cm in width and setting in mortar type B1, 1:2:4 using 20 mm graded aggrigate complete all as specified and as directed.
Material and labour for cutting of road/ hard standing up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 and block top with black bituminous upto existing surface level complete all as specified and as directed by Engineer-in-charge.
Supply and laying GI pipe light grade galvanized with all fittings laid in trenches or fix on wall for cable protection of 80 mm bore complete all as directed by engineer-in-charge.
All as per srl item No 6 above but size 50 mm bore complete all as directed by engineer-in-charge.
Disconnecting,removing & taking out faulty U/G cable off sizes from trenches,wall and ducts complete all specified and as directed
Supply, Laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 300 sqmm x 3.5 core complete all as directed by engineer-in-charge.
All as per srl item No 11 above but size 185 Sq mm x 3.5 core complete all as directed by engineer-in-charge.
All as per srl item No 11 above but size 120 Sq mm x 3.5 core complete all as directed by engineer-in-charge.
All as per srl item No 11 above but size 95 Sq mm x 3.5 core complete all as directed by engineer-in-charge.
All as per srl item No 11 above but size 70 Sq mm x 3.5 core complete all as directed by engineer-in-charge.
All as per srl item No 11 above but size 50 Sq mm x 3.5 core complete all as directed by engineer-in-charge.
All as per srl item No 11 above but size 35 Sq mm x 3.5 core complete all as directed by engineer-in-charge.
All as per srl item No 11 above but size 16 Sq mm x 4 core complete all as directed by engineer-in-charge.
All as per srl item No 11 above but size 10 Sq mm x 2 core complete all as directed by engineer-in-charge.
All as per srl item NO 11 above but of size 400 sq mm 3.5 core
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 240 to 400 sq mm all as specified and directed by engineer-in-charge.
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 16 to 180 sq mm all as specified and directed by engineer-in-charge.
M & L in replacement FRP juction box including MCBs with front cover fixed with locking arrangement with suitable clamp/fixture on pole complete all as specified and directed by Engineer-in-Charge.
Material and labour for cleaning of Electric panel at rusted portion with sand paper and painting with synthetic enamel paint suaitable for metal complete all as specified and as directed by Engineer-in-Charge
Supply & fix in replacement PVC insulated Aluminium conductor twin core service cable ISI marked of size 6 Sqmm complete all as specified & directed by engineer in charge
Supply & fix in replacement PVC insulated Aluminium conductor twin core service cable ISI marked of size 10 Sqmm complete all as specified and as directed by Engr-inCharge.
Preparation of old painted surface of steel tubular swaged poles (9 to 11 meter long) with good neck brackets including junction box, GI pipe and light fittings i.e HPSV/HPMV any rating and painting with one coat of aluminium paint including cleaning the acrylic cover and painting with black to 1.5 mtr height from top of PCC coping and marking pole numbers with one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
All as per item No 28 here in before but using galvanised iron strip 25x4mm as earthhing lead
M&L for 4mm dia GI wire complete all as specified and directed.
Material and labour for galvanised iron strip 25 X 4 mm with saddles and fixing screws and connected as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Disconnecting to worn out cable off size from main control panel /LT over head line/UG line cutting worn out portion and reconnecting including suitable size of aluminium lugs & thimbles ,nuts, bolts & washers comlpete (excavation of necessary earth work shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.)
S&F in replacement of ACB 800 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 36 KA.
S&F in replacement of MCCB 400 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 36 KA.
S&F in replacement of MCCB 250 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
S&F in replacement of MCCB 200 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
S&F in replacement of MCCB 160 Amps FP 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32 AMP in the MCB DB/ junction box complete with connection testing and commissioning.
Supply and fix tape insulation PVC 25 mm wide in various colours of standard length complete all as specified and as directed by Engineer-in-Charge.
M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 1200 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following acessories Incoming:- (a) ACB, 4 pole, 800 amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 50 KA - 01 No ( Incoming) (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue - set 01 Outgoings:- (a) MCCB 4 pole, 250 Amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 36 KA - 03 Nos (b) MCCB 4 pole, 400 Amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 50 KA - 03 Nos
M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 1200 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following acessories: Incoming:- (a) MCCB, 4 pole,400 amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 36 KA - 01 No ( Incoming) (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue - set 01 Outgoings:- (a) MCCB 4 pole, 100 Amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 36 KA - 2 Nos (b) MCCB 4 pole, 160 Amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 16 KA - 02 Nos
M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 800 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following acessories: Incoming:- (a) MCCB, 4 pole,200 amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 36 KA - 01 No ( Incoming) (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue - set 01 Outgoings:- (a) MCCB 4 pole, 100 Amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 36 KA - 05 Nos
Taking down old unsv MCB DB of any size.
Supply and fixing in replacement load line vertical distribution board 'A, frame made out of CRCA 2mm thick mild steel sheet,double door, surface mounting TPN 8 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 125 Amps =01 No MCB for outgoing complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 125 Amps =01 No MCB for outgoing complete all as specified and as directed by Engineer-in-Charge.Cat Part No - DB LL4W DD VERT W/O MCCB Make - Havells or equivalent to Standard Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type Cat Part No - DHDPSHODRW08 complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type Cat Part No - DHDPSHODRW08 complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, and neutral, 240 volts, 40 amps C Curve capacity.
S&F MCB TP 63 Amps 10 KA, 440 volt 50 Hz complete all as specified ans directed by engineer in- charge.
S&F MCB TP 100 Amps 10 KA 440 volt 50 Hz all as specified ans directed by engineer in- charge.
M/S LADPURIA ENTERPRISES
P S TRADERS
Sandeep Enterprises
sheetal engineering
J.P. Enterprises
OMVIN ENTERPRISES LLP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .