Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | L1 | Accepted-AOC being 1st Lowest | |
| 2 | L2₹19.6 L+₹1.9 L (10.9%)Rejected-Finance | L2 | Rejected-Finance Being not a first lowest | |
| 3 | L3₹19.6 L+₹1.9 L (11.0%)Rejected-Finance | L3 | Rejected-Finance Being not a first lowest | |
| 4 | L4₹19.7 L+₹2.0 L (11.6%)Rejected-Finance | L4 | Rejected-Finance Being not a first lowest |
Tender Value
₹19.9 L
EMD Value
₹39,700
Closing Date
1 Feb 2023, 6:00 pmClosed
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
PROVN OF TOILET WITH ALLIED FACILITIES INCL SPECIAL REPAIR TO BLDG NO T-90 UNDER GE (WEST) PATHANKOT
2022_MES_571426_1
GE/PKT-65/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹39,700
Yes
23 Feb 2023
27 Dec 2022
3 Feb 2023
27 Dec 2022
1 Feb 2023
18 Jan 2023
28 Dec 2022 - 5 Jan 2023
Amount
Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 metre in depth for foundation etc and for manholes etc n.exc. 10 Sqm on plan and n.exc. 1.5 metre depth and getting out in soft/loose soil complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.50 above the starting point complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick as in soft/loose soil complete all as specified and directed.
Treating the top surface of filled earth at the rate of 7.50 litres of emulsion per square metre of surface complete all as specified and directed.
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
Material & labour for soil filling under the floor including spreading and levelling in layers n.exc. 25cm thick, well ramming including watering as required complete all as specified and directed.
Material & labour for hardcore of Broken stone boulders or boulders n.exc. 63mm, deposited spread and levelled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed.
Material & labour for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base of floor complete all as specified and directed.
Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Use and waste of Form work of sides of pillars, posts, struts, piers, columns etc square or rectangular or polygonal rough surfaces of concrete complete all as specified and directed.
M&L for Form work to sides and soffits of beams lintels etc finished rough complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick flat fair finished surfaces of concrete complete all as specified and directed.
M&L for form work to the edge of concrete flat n. exc 200 mm thick complete all as specified and directed.
Supply & fixing mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Supply & fix mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required as in stirrups complete all as specified and directed.
M&L for RCC, M-25 using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M & L for RCC, M-25 using 20 mm graded stone aggregate as in Columns, pillars etc complete all as specified and directed.
M & L for RCC, M-25 using 20 mm graded stone aggregate as in beams, lintels over 1.5 m span etc complete all as specified and directed.
M&L for RCC, M-25 using 20 mm graded stone aggregate for roof slabs supported on walls, beams and the like complete all as specified and directed.
Material & labour brick work with fly ash bricks in CM 1;6 brick old size bricks straight or curved on plain exeeding 6m mean radius complete all as specified.
M&L 40mm thick DPC in cement concrete 1:2:4 type B-0 mixing with liquid water proofing admixture as per manufacturer instructiions including necessary form work complete all as specified and directed. (Note:- WPC shall be measured & paid seperateley)
Supply only integral water proofing compound complete all as specified and directed.
Material & labour for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces,in CM(1:4) surface finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for 5 mm thick plaster in CM 1:3 on ceiling surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 using (40 mm graded stone agg) as in sub base complete all as specified and directed.
Supply and fixing joint free non skid Ceramic tiles, coloured 7mm to 8mm thick (square/ rectangular) polished, area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles.
Material & labour for glazed coloured ceramic tiles of size 450x300x7-8mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/ coloured cement to match with existing work over and including 10mm thick rendering in CM 1:4 complete all as specified & directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE.
Material and labour for Cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified.
Material & labour for preparation of new plastered surfaces of walls etc and applying two coats of cement base paint over a coat of primer complete all as specified & directed.
Material and labour for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified & directed.
Material and labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified & directed.
Material & labour for cleaning of plastered /concrete surfaces and Applying roof treatment on top of roof with APP modified membrane with non–woven polyster reinforcement/mat (centre core) with thermal insulation with white mineral gravel finish on upper side of weight not less than 3.5 Kg/Sqm & thickness not less than 3mm, laid by torch application method with overlap 100mm on length side and 100mm on the width side as per manufacturer’s instructions over a coat of approved cold applied bituminous oil based primer (IS-3384) @ 0.30 Litre/Sqm and including 20 mm thick screed bed in CM 1:4 including mixed with water proofing admixture as per manufacturer's instructions and ensure water does not stand anywhere after Sprinkle water on the roof surface complete all as specified.(Note:- WPC shall be measured and paid separately) Note:- Water proofing treatment shall be provided with APP modified membrane on plastered surface as per manufacturer’s instructions and under strict supervision of manufacturer technical representative.
Flat iron hold fast 25mm x 6mm welded to angle iron door frame complete all as specified and directed.
Mild steel angle iron door frame 40mmx40mmx6mm conforming to Fe 410-0 incl 12mm dia deformed bars for strengthing at bottom of chowkhats incl cutting floor at bottom to accommodated strengthing bars & making good the floor in PCC 1:2:4 type B-0 to match the existing floor complete all as specified and directed.
Supply & fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC , ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed to getter with solvent cement, supplying & fixing in the frame at site as per specification & drawing for Item No. 08080 on page No 156 of SSR 2010 (Part-II) complete all as specified and directed.
Supply & fixing 150mm size aluminium alloy handles cast type anodized complete all as specified & directed.
S&F aluminium tower bolts 150mm long, of extruded section complete all as specified and directed.
Supply & fixing Aluminium. Sliding door bolts, plate type, complete, 250mm long complete all as specified and directed.
M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F Steel window/ventilator factory made out of box type and shutter (double shuter) with sash bar made out of section using flash butt welding, complete including hinges ,tower bolt,handle , grill 10 mm sq bar including two coat of synthetic enamel paint over one coat of red oxide primer, tarred hold fasts, PCC blocks, including plain/figured glass and wire mesh 0.36 mm nominal dia of wire and average width of aperture 1.18 mm all as shown on drg No CEPZ /TD-245/01 sheet 1/1 and CEPZ /TD -246/01 sheet No 1/2 & 2/2 complete all as specified and directed.
S&F 20mm thick Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply & fixing bib taps cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm bore, complete all as specified & directed.
Supply & fixing vitreous china wash hand basin, white, flat back of size 550x400mm counter Wash basin and 15mm thick Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed (excluding taps, waste chain and plug and porcelain stopper) but including brackets suitable for 15mm dia pipe complete all as specified & directed.
Supply & fixing angular valve, 15 mm dia, cast copper alloy, chromium plated, fancy type with long shank and cup, screwed down, high pressure screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified & directed.
Supply & fixing rotational moulded polyethylene water storage tanks 500 liters capacity, (cylindrical, vertical in closed top) hoisted and fixed in position with all GI fittings complete all as specified and directed.
Supply & fixing PVC low level flushing cistern of 9-10 ltrs capacity, ISI Marked, white, symphonic action type with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm bore, suitable for low level cistern complete all as specified & directed.
Supply & fixing 15mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed.
Supply & fixing 20 mm bore, tubes medium grade, galvanized with all fittings and fixed to walls and ceiling or laid in floors including testing complete all as specified & directed.
Supply & fixing 3mm thick sheet glass, pin headed, and glazing with oil putty/beading in square not exceeding 0.50sqm each pane complete all as specified & directed.
Supply & fixing butt hinges, 100 mm long of stainless steel, complete all as specified & directed.
Supply & fixing PVC connections of 450mm long suitable for 15mm dia iron pipe including PTMT nuts complete all as specified & directed.
Supply & fix vitreous china squatting pan of ‘Orrisa pattern’ size 580x440mm, white with, integral foot rest including ‘P’ or ‘S’ trap, lime concrete bedding and making good floor complete all as specified and directed.
S&F Flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and directed.
S&F for 110 mm bore PVC floor traps plain with grating and 300 mm long out let including jointing with cement concrete 1:2:4, type B-1 complete all as specified & directed.
Supply and fixing PVC bends 110mm bore, any radius complete all as specified & directed.
S&F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified & directed.
S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed.
PVC (SWR), junction single, (Single T) equal or unequal 110 mm bore complete all as specified and directed.
Supply & fixing vitreous china wash down water closet Pedestal pattern white plastic seat cover for W.C.(E.T.) white including M.S. CP or aluminium hinging device complete all as specified and directed.
S&F CP brass jet spray with hand hold arrangement incl. 1.5m long flexible pipe with hook of superior quality complete all as specified & directed.
S&F Tubular towel rail 20mm dia, D type, 60cm long between flanges Aluminium anodised complete all as specified and directed.
M&L for 50mm thick PCC 1:2:4, type B-1 (20 mm graded aggregate) finish even without using extra cement as in floor complete all as specified and directed.
M&L for 50mm thick 1:2:4 type B-0 (12.5 graded grade aggregate) as in copings complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc complete all as specified and directed.
M&L for Concrete bed to drain pipes 150mm including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC(1:4:8) type D2 (using 40 mm graded stone aggregate) complete all as specified and directed.
M&L for unplasticized sewage/drainage pipe 150mm dia type 'B' with wall thickness 4mm (min) of pessure rating 8KN/Sqm laid in trenches and jointed with solvent including testing complete all as specified and directed.
M&L for Precast cement concrete solid block in PCC 1:2:4 type B-1 using (20 mm graded aggregates) set in CM 1:4 complete all as specified and directed. (Note:- Size of precast concrete block as per directed by GE)
M&L for 80mm thick PCC tile coloured rubber moulded (interlocking type) interlocking tiles joint filled with sand and campacted with mechanical plate vibrator complete all as specified and directed.
M&L for Sand for cushioning, interlocking tiles joint to be filled with sand, including spreading and levelling in layers n exc 25 mm thick complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position in Unframed work complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position in framed work complete all as specified and directed.
S&F steel work tubular trusses incliding special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S 1161-1979 grade st-240 complete all as specifed and directed
Dismantling asbesots cement (corrugated, semi-corrugated etc) sheets in roof coverings complete all as specified and directed.
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or 'J / L' hooks all as specified and directed.
All as per srl item No. 77.00 but plain sheet as in ridges, gutters , facia bd etc
Demolition of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas, & similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition) and disposal of debris out of MoD land complete all as specified and directed.
Demolition of brick work built in cement mortar complete all as specified and directed
Dismantling wall and ceiling boards or insulation boards any thickness, any description including cover fillets complete all as specified and directed
S & F for suspended false ceiling system using chicago metallic (E grid) exposed suspended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture complete all as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints hacking for key and scrubbing down with water etc complete all as specified and as directed.
M & L for 15 mm thick rendering in CM (1:4) on fair faces of brick wall or concrete surface finished fair & even without using extra cement complete all as specified and as directed.
M & L for rendering 15 mm thick on Brick wall finished fair & even in CM (1:6) complete all as specified and directed.
Material and labour for preparation of newly plastered internally surfaces of wall and applying min 1.5 mm thick wall care putty on the surfaces & making the surface absolutely smooth surface and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion finished without any brush marks on the surface in any colour including necessary scaffolding up to four storeys height of bldgs if required ,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
Material and labour for complete removal of existing treatment internally surface of wall and applying min 1.5 mm thick wall care putty on the surfaces and making surface absolutely smooth and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion without any brush marks on the surface in any tint including necessary scaffolding up to four storeys height of bldgs if required ,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
M & L for preparation of old plastered surfaces of walls and applying one coats of cement base paint complete all as specified and as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site complete all as specified and directed.
Taking down chowkat with shutters of any description without taking off shutters from frame area exc 1.50 Sqm but not exc 4.00 sqm complete all as specified and directed.
S & F pressed steel frames 125 x 60 x1.25 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate including one shop coat of primer complete all as spd and directed
M & L for cement concrete type C-0, 1:3:6 using 12.5 mm graded crushed stone aggregate as in back filling of hollow portion of frame with plain cement concrete and for fixing of hold fast complete all as specified and directed.
S&F 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, confirming to IS- 2202(Part-I-1999), ISI Marked complete all as specified and directed
S&F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc divided in square with plain, chamfered or rounded mitered and rebated sash bars any number, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, complete all as specified in SSR Part I section 8, clause 8.24 (a) fitted to chowkat complete all as specified and directed.
S&F for 200 mm long anodised aluminium barrel tower bolt of extruded section complete all as specified and as directed.
S&F 300mm long aluminium anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F Mild steel 300 mm, ordinary rat rail tail, rod pattern springs, including roller and roller plate (Helical door spring) complete all as specified & directed.
M&L for preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n. exc. 15 cm thick (below or above ground level) complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS15658-2006 of 60 mm thickness M-35 Grades complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises and removing the debris outside from defence land complete all as specified and directed .
Supply and fixing joint free non skid Ceramic tiles, coloured 7mm to 8mm thick (square/ rectangular) polished, area of each tiles exceeding 0.11 sqm but not exceeding 0.18 Sqm in vertical/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat/rendering in cement mortar 1:4 for fixing of tiles complete all as specified and as directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, Bracke sketch fitting, ceiling roses, lamp holders, brackets, pendants, regulators, sockets, light fitting etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by EIC. Note:- The damaged surfaces to be made good with plastering (1:6). & applying colour wash in required coats to matching with existing surfaces as directed by Engineer-in-charge. Cost of the same deem to be included in quoted rates and nothing extra on this account admissible.
M&L for Point wiring with 1.5 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade drawn through and incl PVC rigid concealed conduit (ISI Marked) suitable size with all accessories having thickness not less than 1.8mm incl sheet steel/ CI terminal box of adequate size having thickness not less than 2mm including 3mm thick hylem/masonite sheet including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor multistranded cable of green colour as earth conductor connected to common earth dolly complete all as specified and directed for one light / fan point controlled by one switch 5 Amp, SP, one way, 240 Volts complete all as specified and directed. Note: 1. Connections of cable with MCBs/Switch Sockets shall be done through proper size copper/brass thimbles. 2. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit in not feasible. 3. Proper colour code will be used for wiring as per the electrical rule and as directed.
All as per Srl item No 105.00 here-in-before but for one 5 pin 5 Amp socket outlet point on inependent board controlled by one switch SP, one way 5 Amp, 240Volts.
All as per Srl item No 105.00 here-in-before but for one 5 pin 5 Amp socket outlet point on same board controlled by one switch SP, one way 5 Amp, 240Volts.
M & L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable with in and including PVC concealed conduit heavy duty 20mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface complete all as specified and directed. Note:- (a) Insulation test of point wiring (b) colour coding is to be maintained
S & F switch piano flush button single pole one way 5 Amp AC 240 volts, all as specified and as directed.
S & F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S & F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed.
M & L for ceiling rose, PVC/Polycarbonate, insulated body, surface Bakelite 65mm dia three terminals all as specified and as directed.
Supply and fixing of ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.
S & F LED Bulb B22 type ,14 watt white ,complete all as specified and directed.
S&F 20W surface / wall mounted batten LED luminair, extruded aluminium housing with PC diffuser and ind electronic driver with high efficiency long life, CRI = 80 (Minimum), PF > 0.95, luminous efficacy > 100 lumens/Watt operating voltage 140V-240V, CCT (K) > 6500, THD < 10% complete including 20W LED tube rod with all accessories internally prewired and including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed
S & F of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
S&F MCB SP 240V, 50Hz, 10 KA, 'B' curve of rating 6 to 32 Amp all as specified and directed.
S&F MCB SPN 240V, 50Hz, 10 KA, 'B' curve of rating 6-32 Amp all as specified and directed.
S & F bldg secuirty light fitting energy saving high efficiency LED street light fitting 30 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 32 mm dia bent to shape having length on less than 1.5 mtr fixing with clamp etc and making connections using cord flexible 3 core copper cable of size 23/ .0076 from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.25 metre deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as showin in electrical plate No.3 of SSR Part-I (2009) including filling of charcoal dust, common salt all around Earth plate upto 150 mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40 mm thick RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregrate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including test on completion. (Note :- The rate quoted include cost of min 7.5 metre earthing wire)
S&F mirror light 10 Watt LED 2' length prewired with all accessories including lamp and connected electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor 3core cable of size 0.50Sqmm complete all as specified and directed.
S&F Energy saving, surface mounted, bulk head LED luminaire 10 W with PDC aluminium housing and polycarbonate diffuser with IP 66 protection complete including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified & directed.
M & L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing MS ventilating fans Single phase, 230 volts 300 mm or 12” H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
S & F of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
S & F storage type Electric water heater (Geyser) capacity 25 ltrs , BEE 5 star rating PVC body with PVC connection 15 mm x 450mm long 2 no for each geysers, complete accessoiries complete all as specified and directed
M&L for sub Main Wiring with 2 run of single core, 6 Sqmm FRLS PVC insulated and unsheathed, multi starndedcopper conductor cable using colour code for phase red and neutral black with and including 6 Sqmm FRLS PVC insulated and unsheathed copper conductor cable in green colour as earth conductor connected to common earth dolly, drawn in and including concealed PVC rigid conduit of suitable size having thickness not less than 1.8mm (ISI marked) with and including all accessories complete and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface including taking down of existing unserviceable surface/cocealed sub main wiring any type complete all as specified and directed. Note:- Two run of submain wire (phase and neutral), and one run of earth including PVC conduit and accessories will be measured as one run.
Supply, fixing, testing and connecting the BEE star rated ceiling fan 230 volts, single phase of 1200 mm sweep double bearing type, copper winding, Air delivery 230 m3/min including down rod, canopy cover etc and connecting with flexible copper conductor of 1.50 sq mm 3 Core and including writing of MES No with black enamelled paint complete all as spd and directed.
S&F stop valves, cast copper alloy, screwed down, high pressure with crutcher butterfly handle, screwed both ends for 15mm bore dia of pipe complete all as spd and directed.
Supply & fixing bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe of 15mm bore, complete all as specified & directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with 20Amp single pole MCB complete all as specified & directed.
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 9,926.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 3% (Three percent) of the accepted contract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
Abrol construction co
Nishikant Mahajan Govt Contractor
M/S Raghuvanshi Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .