Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.3 LAccepted-AOC | ₹22.3 L | 1 | Accepted-AOC Work Order |
| 2 | 2₹23.7 L+₹1.4 L (6.16%)Rejected-Finance | ₹23.7 L+₹1.4 L (6.16%) | 2 | Rejected-Finance Reject |
| 3 | 3₹24.9 L+₹2.5 L (11.4%)Rejected-Finance | ₹24.9 L+₹2.5 L (11.4%) | 3 | Rejected-Finance Reject |
| 4 | 4₹26.0 L+₹3.7 L (16.8%)Rejected-Finance | ₹26.0 L+₹3.7 L (16.8%) | 4 | Rejected-Finance Reject |
| 5 | 5₹26.0 L+₹3.7 L (16.8%)Rejected-Finance | ₹26.0 L+₹3.7 L (16.8%) | 5 | Rejected-Finance Reject |
Tender Value
₹26.3 L
EMD Value
₹31,286
Closing Date
17 Jan 2026, 5:00 pmClosed
Additional Chief Executive Officer Z P Satara
Additional Chief Executive Officer Z P Satara
REPAIRING OF SCHOOL BUILDING FOR ZILLHA PARISHAD PRIMARY SCHOOL 7 ROOMS AT KENJAL TAL WAI DIST SATARA
2026_SATAR_1268027_12
Works/North/A-8/Shala/10/25-26
Open Tender
Civil Works
Percentage
180 days
REPAIRING OF SCHOOL BUILDING FOR ZILLHA PARISHAD P
Registered Qualified unemployed Engineers
8 documents required · 8 mandatory
₹1,000
₹31,286
13 Aug 2026
10 Jan 2026
19 Jan 2026
10 Jan 2026
17 Jan 2026
10 Jan 2026
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts excetra complete. Item / Page No : 19 / 297 Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge.
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts excetra complete. Item / Page No : 15 / 296 Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge.
Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts excetra complete. Item / Page No : 9 / 296 Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge.
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 40 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor)kajaria as per specification (using ARTIFICIAL SAND). Item / Page No : 41 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing solid core flush door shutter commercial in single leaf 32 milimetre thick without ventilator commercial type of exterior grade as per detailed drawings, with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting three coats, excetra complete. (For Ground Floor) Item / Page No : 10 / 246 Specification No : Bd.T.36 Spec. Page No : 500
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With powder coating without box. (For Ground Floor) Item / Page No : 44 / 254 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and applying plastic emulsiton paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface (excluding the primer coat), excetra complete. (For Ground Floor) Item / Page No : 12 / 227 Specification No : Bd.P.6 Spec. Page No : 414 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor) Item / Page No : 25 / 225 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For Ground Floor) Item / Page No : 34 / 236 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). - 301 milimetre to 600 milimetre girth (surface width) (For Ground Floor) Item / Page No : 35 / 237 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housing, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes - Capacity between 1000 litres to 20000 litres. (For Ground Floor) Item / Page No : 54 / 280 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND). Item / Page No : 1 / 175 Specification No : Bd.E.1 Spec. Page No : 287-288 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 197 Specification No : Bd.G.1 Spec. Page No : 313 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : Bd.G.5 Spec. Page No : 315 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 with neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 209 Specification No : Bd.L.2, Bd.L.10 Spec. Page No : 368, 370 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 209 Specification No : Bd.L.4 Spec. Page No : 368 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing on walls / celling / floor, 15 milimetre diameter chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) Item / Page No : 55 / 280 Specification No : Bd.V.5 Spec. Page No : 551 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates excetra as per detailed desings and drawings or as directed including cuting, fabricating, hoisting, erecting, fixing in position, making rivetted / bolted / welded connection and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For Ground Floor) Item / Page No : 4 / 173 Specification No : Bd.C.8 Spec. Page No : 278
Providing 25 milimetre to 30 milimetre thick partition of polished black Kadappa stone slab of approved quality including giving required sizes and shape, excetra, fixing in cement mortar 1:3, curing and cement, excetra complete. - One side polish (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 32 / 216 Specification No : Bd.M.35B Spec. Page No : 393 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying vitrified rustic matt stone finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 44 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor) Item / Page No : 2 / 264 Specification No : Bd.U.1 Spec. Page No : 537
Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 68 / 220 Additional Specifications : 1. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and applying one coat of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding if necessary, cleaning and preparing surface (excluding primer coat), excetra complete. (For Ground Floor) Item / Page No : 8 / 223 Specification No : Bd.O.6 Spec. Page No : 406
Providing and fixing crimped wire galvanised iron mesh of size 20 milimetre X 20 milimetre, 10 gauge to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its origional position and oil painting, excetra complete. (Excluding cost structural steel) (For Ground Floor) Item / Page No : 21 / 295 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at one kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre X 300 milimetre, making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 205 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in charge. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 184 Specification No : BDF-9, B-7 Spec. Page No : 303-304, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) Item / Page No : 33 / 188 Specification No : Bd.F.17 Spec. Page No : 306
Providing and fixing oval type under counter wash hand basin of 16 inch X 22 inch size and of special colour shed having telephonic black / colour granite of 18 milimetre thick fixed on black kadapaa frame work, including cromium plated coupling, bottle-trap using approved make oval type wash basin as per detailed drawing or as directed by Engineer In-charge, excetra complete. (For Ground Floor) Item / Page No : 88 / 283 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and fixing Name board of size 0.90 X 1.20 mtr.with two vertical Angle of 40 X 40 X 5 mm of 2.25 mtr.height out of which 0.45 mtr.embedded in cement concrete 1:4:8 of trap metal and M.S.Angle 40 X 40 X 5 mm top and bottom and 16 gauge thick sheet including anticorrosive and oil paint coating and lettering of text height 3 inches as Yellow background and letters in black colours etc. complete Rate Abst No : Rate Abstract No : 0053 Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 40 / 217 Specification No : As per Item No 4 Spec. Page No : --- Additional Specifications : As per Item No 4
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor)kajaria as per specification (using ARTIFICIAL SAND). Item / Page No : 41 / 217 Specification No : As per Item No 5 Spec. Page No : --- Additional Specifications : As per Item No 5
Providing and fixing solid core flush door shutter commercial in single leaf 32 milimetre thick without ventilator commercial type of exterior grade as per detailed drawings, with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting three coats, excetra complete. (For First Floor) Item / Page No : 10 / 246 Specification No : As per Item No 6 Spec. Page No : --- Additional Specifications : As per Item No 6
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With powder coating without box. (For First Floor) Item / Page No : 44 / 254 Specification No : As per Item No 7 Spec. Page No : --- Additional Specifications : As per Item No 7
Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For First Floor) Item / Page No : 34 / 212 Specification No : Bd.P.6 Spec. Page No : 414 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For First Floor) Item / Page No : 25 / 225 Specification No : As per Item No 9 Spec. Page No : --- Additional Specifications : As per Item No 9
Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For First Floor) Item / Page No : 34 / 236 Specification No : As per Item No 10 Spec. Page No : --- Additional Specifications : As per Item No 10
Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housing, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes - Capacity between 1000 litres to 20000 litres. (For First Floor) Item / Page No : 54 / 280 Specification No : As per Item No 12 Spec. Page No : --- Additional Specifications : As per Item No 12
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : As per Item No 15 Spec. Page No : --- Additional Specifications : As per Item No 15
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 with neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 209 Specification No : As per Item No 16 Spec. Page No : --- Additional Specifications : As per Item No 16
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 209 Specification No : As per Item No 17 Spec. Page No : --- Additional Specifications : As per Item No 17
Providing, laying and fixing polyvinyl chloride pipe of 110 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete. Item / Page No : 28 / 277 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing 25 milimetre to 30 milimetre thick partition of polished black Kadappa stone slab of approved quality including giving required sizes and shape, excetra, fixing in cement mortar 1:3, curing and cement, excetra complete. - One side polish (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 32 / 216 Specification No : As per Item No 20 Spec. Page No : --- Additional Specifications : As per Item No 20
Providing and fixing white glazed earthenware wash hand basin of 55 centimetre X 40 centimetre size including cold water piller tap / cold and hot water piller tap brackts, rubber plugs and brass chain, stop tap and necessary pipe connections including polyvinyl chloride waste pipe and trap upto the outside face of the wall.Making good the damaged surface,testing excetra complete. (For First Floor) Item / Page No : 63 / 272 Specification No : Bd.V.30 Spec. Page No : 565
Providing and laying vitrified rustic matt stone finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 44 / 217 Specification No : As per Item No 21 Spec. Page No : --- Additional Specifications : As per Item No 21
Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For First Floor) Item / Page No : 2 / 264 Specification No : As per Item No 22 Spec. Page No : --- Additional Specifications : As per Item No 22
Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For First Floor) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 68 / 220 Specification No : As per Item No 23 Spec. Page No : --- Additional Specifications : As per Item No 23
Providing and applying one coat of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding if necessary, cleaning and preparing surface (excluding primer coat), excetra complete. (For First Floor) Item / Page No : 8 / 223 Specification No : As per Item No 24 Spec. Page No : --- Additional Specifications : As per Item No 24
Providing and fixing frame with / without ventilator of size as specified with non teak wood for doors and windows including chamfering, rounding, rebating holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For First Floor) Item / Page No : 2 / 245 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181 Specification No : Bd.F.6, B-7 Spec. Page No : 300-301, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 184 Specification No : As per Item No 27 Spec. Page No : --- Additional Specifications : As per Item No 27
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates excetra as per detailed desings and drawings or as directed including cuting, fabricating, hoisting, erecting, fixing in position, making rivetted / bolted / welded connection and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For First Floor) Item / Page No : 4 / 173 Specification No : As per Item No 19 Spec. Page No : --- Additional Specifications : As per Item No 19
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Mechanical Means Item / Page No : 2 / 153 Specification No : Bd.A.1 Spec. Page No : 259
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181 Specification No : As per Item No 50 Spec. Page No : --- Additional Specifications : As per Item No 50
Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water, striking joints on unexposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 199 Specification No : Bd.H.1 Spec. Page No : 329 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. Item / Page No : 37 / 157 Specification No : Bd.A.11 Spec. Page No : 263-264
Providing and laying ceramic tiles of having sizes 30 centimetre X 45 centimetre and confirming to corrosponding Indian standared for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 26 / 215 Specification No : Bd.M.13 Spec. Page No : 386 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying antiskid ceramic tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to Indian Standard 15622:2006 (Group BIIa) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 67 / 220 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying polished Shahabad stone Flooring 25 milimetre to 30 milimetre thick and of required width wide in plain / diamond pattern on a bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 213 Specification No : Bd.M.3, Spec. Page No : 380 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 70 / 182 Specification No : Bd.F.8, B-7 Spec. Page No : 302-303, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and fixing on walls / celling / floor 15 milimetre diameter unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) Item / Page No : 89 / 284 Specification No : Bd.V.5 Spec. Page No : 551 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing on walls / celling / floor 25 milimetre diameter unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor) Item / Page No : 91 / 284 Specification No : Bd.V.5 Spec. Page No : 551 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing on walls / celling / floor 50 milimetre diameter unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete. (For Ground Floor) Item / Page No : 94 / 284 Specification No : Bd.V.5 Spec. Page No : 551 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing European type white glazed earthenware water closet pan with unplasticized poly vinyl chloride seat and lid with chromium plated brass hinges and rubber buffers including unplasticized poly vinyl chloride vent pipe up to the outside face of wall, without flushing cistern with flush cock and with water jet and necessary fitting including cutting and making good to the walls and floors, testing, excetra complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) (For Ground Floor) Item / Page No : 20 / 289 Additional Specifications : 1. Prior approval of sample and brand by Executive Engineer is necessary before use. 2. The work shall be carried out as per instructions of Engineer in charge.
Providing and fixing wall mounted European type white glazed earthenware water closet pan with unplasticized polyvinyl chloride seat and lid with chromium plated brass hinges and rubber buffers including unplasticized polyvinyl chloride and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 milimetre diameter unplasticized polyvinyl chloride flush pipe with fittings and clamps ,20 milimetre dia.UPVC overflow pipe ,mosquito proof couplings galvanised iron chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing , excetra complete.( prior approval of sample and brand by Ex. Engineer is necessary before use) (For Ground Floor) Item / Page No : 44 / 292 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
Providing and fixing fibreglass reinforced polyster door shutter 30 milimetre thick as per Indian Standard : 14856 (2000) (reaffirmed-2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, excetra complete. (For Ground Floor) Item / Page No : 58 / 257 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing with hot dip zinc coating including fabricating, glazing with plain / obscured glass panes 5 milimetre thick of approved type and quality and iron oxidised fixtures and fastening, oil paint two coats, excetra complete. (For Ground Floor) Item / Page No : 29 / 249 Specification No : Bd.T.53 Spec. Page No : 509 Additional Specifications : The work shall be done as per instructions of Engineer in charge.
Providing weathered pointing with cement mortar 1:3 for stone / brick masonry including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 19 / 210 Specification No : Bd.L.17 Spec. Page No : 373 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing soak pit of size 120 centimetre X 120 centimetre X 120 centimetre including excavating and filling with brick bats. Item / Page No : 19 / 275 Specification No : Bd.V.46 Spec. Page No : 576
Providing soling using 80 milimetre size trap metal in 15 centimetre layer including filling voids with crushed sand / grit, ramming, watering, excetra complete. Item / Page No : 40 / 157 Additional Specifications : The work shall be carried out as per instructions of Engineer in-charge.
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 11 / 178 Specification No : Bd.F.3, B-7 Spec. Page No : 298, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 31 / 179 Specification No : Bd.F.5, B-7 Spec. Page No : 300, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 23 / 185 Specification No : Bd.F.12, B-7 Spec. Page No : 304-305, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
Compressive Strength of Cement Concrete Cube 1 Test for quantity upto 5 cubic metre, 2 Tests for quantity above 5 cubic metre and upto 15 cubic metre, 3 Tests for quantity above 15 cubic metre and upto 30 cubic metre, 4 Tests for quantity above 30 cubic metre and upto 50 cubic metre. For quantity 50 cubic metre and above - 4 Tests + 1 Test for each additional 50 cubic metre
Sieve Analysis Test for Metal below 40 milimetre 1 Test per 200.00 Cubic Metre
Water Absorption, Specific Gravity, Impact Value, Crushing Value Test for Metal below 40 milimetre 1 Test per Source
Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks 1 Test per 50000.00 Number
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.65 MB
b1.pdf
Tender Documents • 5.61 MB
BOQ_2184317.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .