Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L1 | Accepted-AOC Being a lowest bidder and reasonalbe | |
| 2 | L2₹24.4 L+₹71,605.60 (3.02%)Rejected-Finance 60 4 MOTILAL GUPTA ROAD KOL 700008 | KOLKATA | WEST BENGAL | 700008 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹41.6 L+₹17.9 L (75.8%)Rejected-Finance 72 A ABINASH CHANDRA BANERJEE LANE KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹42.7 L+₹19.1 L (80.6%)Rejected-Finance VILL JETHIA NATUN PARA PO JETHIA HALISAHAR PIN 743135 | 24 PARAGANAS NORTH | WEST BENGAL | 743135 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹49.9 L+₹26.3 L (110.9%)Rejected-Finance 168 BISWA SINGHA ROAD NEAR DAS BROTHERS COOCH BEHAR WEST BENGAL 736101 | COOCHBEHAR | WEST BENGAL | 736101 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
28 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/ MAINT OF EXTERNAL LIGHTING IN CERTAIN MD AND OTM ACCN ALONGWITH CONNECTED WORKS AT OUTSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2024_MES_641486_1
8216/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹79,000
30 Mar 2024
8 Feb 2024
29 Feb 2024
8 Feb 2024
28 Feb 2024
21 Feb 2024
Amount
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Excavation in Trenches exc. for each additional 1.5m or part thereof in depth beyond the first 1.5 m for laying of steel tubular pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and Specifications.
Returning, filling in, including spreading watering and well ramming in layers not exc 25cm in layers, complete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
M&L for Sand cushioning in trenches for cushioning of LT underground cable including spreading, leveling, well ramming in layers not exceeding 25cm in depth, complete all as specified and directed.
Supply and fix sub class 'B' bricks of standard size for cable protection in trenches complete all as specified and directed.
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 35 Sqmm, 3.5 core
Relaying of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminum conductor cable, laid in trench or fixed to wall / passing through pipe/ pole. (retrieved against item No 1 above) incl necessary aluminum thimbles, jointing and testing complete all as specified and directed for the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 35 Sqmm, 3.5 core
Supply, Laying, jointing and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminum conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary thimbles complete all as specified and directed for the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 Sqmm, 4 core
16 Sqmm, 4 core
25 Sqmm, 4 core
35 Sqmm, 3.5 core
Taking out existing unserviceable/ defective light fitting / high bay light fitting of any wattage from poles/walls/ high mast (including taking down of high mast fitting), dismantling the complete fittings of checking out the defects, trace out damage/ unserviceable parts like driver, wire, led lamp etc and clean thoroughly the complete set and re-fixing in its original position after replacing defective parts including testing complete all as specified and as directed by Engr-in-Charge. Note :- (a) Any minor item like nuts, bolts, clamps, washers and wires for connection is required to make the fitting serviceable are deemed to be included in the quoted rate. (b) Defective parts replaced against relevant items shall be paid under supply only item.
M&L for replacement of electronic driver with input voltage 220 to 240 volts and output voltage suitable for different LED of luminaires, complete all as specified and directed for the following types and capacities:-. (NOTE: Make of driver shall be as OEM or any other make as specifically approved by GE)
35/36 Watt Street Light Luminaire
40/45 Watt Street Light Luminaire
60/70 Watt Street Light Luminaire
80/90 Watt Street Light Luminaire
100/120 Watt Street Light Luminaire
30 Watt Flood Light Luminaire
50 Watt Flood Light Luminaire
60 Watt Flood Light Luminaire
80 Watt Flood Light Luminaire
100 Watt Flood Light Luminaire
120 Watt Flood Light Luminaire
150/160 Watt Flood Light Luminaire
180/200 Watt Flood Light Luminaire
9/10 Watt Bollard Light Luminaire
25-40 watt post top lantern
M&L for replacement of PVC insulated Multi Stranded Copper Conductor Cable 1.5 Sqmm 3 Core, Round Flexible for connection of Street Light Fitting complete all as specified and as directed.
M&L for replacement of PVC Insulated Multi Stranded Flat Service Aluminium Conductor Cable, 1100 Volt grade, heavy duty, served with inner sheathing of PVC Tape and overall PVC sheathed of size 10 Sqmm 3 Core complete all as specified and as directed.
M&L for replacement of PVC Insulated Multi Stranded Flat Service Aluminium Conductor Cable, 1100 Volt grade, heavy duty, served with inner sheathing of PVC Tape and overall PVC sheathed of size 16 Sqmm 4 Core complete all as specified and as directed.
Supply and fix in repairs LED Street Light fitting, of various capacity as mentioned under, in high pressure die cast aluminum housing with lens and toughened sealed glass cover with integrated constant current electronic driver, incl taking down existing fitting complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power Factor not less than 0.95 (e) Having in built short circuit and surge protection upto 5 kV (f) Colour temperature not less than 5700 degree K (g) Life not less than 50000 hours of operation (h) Weather protection grade: IP66 (NOTE: (1) Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Wire for electric connection shall be measured and paid separately)
60 Watt Street Light Luminaire
90 Watt Street Light Luminaire
M&L for replacement of Surge Protection Device of capacity 10 KV Single Phase 50 Hz complete all as specified and as directed. NOTE : MAKE of Surge Protection Device should be provided as per Light Fittings MAKE available at Site of Work.
Supply and fix in repairs LED Street Light fitting, of various capacity as mentioned under, in high pressure die cast aluminum housing with lens and toughened sealed glass cover with integrated constant current electronic driver, incl taking down existing fitting complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power Factor not less than 0.95 (e) Having in built short circuit and surge protection upto 5 kV (f) Colour temperature not less than 5700 degree K (g) Life not less than 50000 hours of operation (h) Weather protection grade: IP66 (NOTE: (1) Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Wire for electric connection shall be measured and paid separately)
70 Watt Flood Light Luminaire
120 Watt Flood Light Luminaire
170 Watt Flood Light Luminaire
Supply and Fix in repairs, LED bollard made with aluminum extrusion, 10 Watts,CCT 3000°K,with UV stabilized injection moulded opal polycarbonate diffuser and degree of protection IP-65, complete all as specified and directed.[Cat No LBLSN-10-CDL of Make 'CG' or equivalent Model of Make 'Philips'/ 'Bajaj']
Supply and Fix in repairs, LED post top light fittings, 40 Watts,CCT 3000°K,with aluminum housing and injection moulded opal polycarbonate diffuser and degree of protection IP-65, complete all as specified and directed. [Cat No.LPTO-40-CDL-M of Make 'CG' or equivalent Model of Make 'Philips'/ 'Bajaj']
Supply and Fix in repairs, LED post top light fittings, 20 Watts, Heritage type CCT 3000°K,with aluminum housing and injection moulded opal polycarbonate diffuser and degree of protection IP-65, complete all as specified and directed. LPTH-20-CDL of Make 'CG' or equivalent Model of Make 'Philips'/ 'Bajaj']
Supply and fix in repairs LED Highbay luminaire, circular shape, of 150 watt capacities, in high pressure die cast aluminum housing with lens and toughened glass cover with integrated constant current electronic driver, incl taking down existing fitting complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy > 140 lumen/watt (b) CRI not less than 80, (c) THD < 10% (d) Power factor not less than 0.95 (e) having in built short circuit and surge protection > 5 kV (internal), 10 KV ( External ) (f) colour temperature not less than 5700 degree K (g) life not less than 50000 hours of operation (h) Weather protection grade: IP66 (NOTE: (1) Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work. (2) Wire for electric connection is included in the above quoted rate. Make Magik Cat No HCVP150 C or equivalent
S&F in repairs Solar Bollard LED Light 1.6 watt, consists of alloy aluminum housing stand and poly carbonate diffuser, cool white, safe operation with maintenance free integrated lithium ion battery with Over-charged, deep-discharged & short-circuit protection, with integrated constant current electronic driver, two lighting mode incl all fittings and fixtures complete with PCC work incl taking down existing luminaire complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 100 lumen/watt (b) CRI not less than 70, (c) Power factor not less than 0.90 (d) Colour temperature not less than 5700- 6500 K (e) Life not less than 50000 hours of operation (f) Weather protection grade: IP65 Make : Havells, Model : BUDZ
S&F in repairs Solar Post Top Lantern 20 watt with inbuilt solar PV module consists of die cast aluminum housing with polycarbonate clear diffuser, cool white, safe operation with maintenance free integrated lithium ion battery with Over-charged, deep-discharged & short-circuit protection, with integrated constant current electronic driver with PIR sensor for 360° coverage up to 8 mtr from base of light fixed on suitable size of GI pipe OD 72- 76mm light grade incl all fittings and fixtures complete with PCC work incl taking down existing luminaire complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 100 lumen/watt (b) CRI not less than 70, (c) Power factor not less than 0.90 (d) Colour temperature not less than 5700 - 6500 K (e) Life not less than 50000 hours of operation (f) Weather protection grade: IP65 Make : Havells, Model : MANOR
S&F in repairs Solar Post Top Lantern 20 watt with inbuilt solar PV module consists of die cast aluminum housing with molded polycarbonate lens plates, cool white, safe operation with maintenance free integrated lithium ion battery with Over-charged, deep-discharged & short-circuit protection, with integrated constant current electronic driver with multiple lighting timing operated through remote controller fixed on suitable size of GI pipe OD 57- 62mm light grade incl all fittings and fixtures complete with PCC work incl taking down existing luminaire complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 100 lumen/watt (b) CRI not less than 70, (c) Power factor not less than 0.90 (d) Colour temperature not less than 5700 - 6500 K (e) Life not less than 50000 hours of operation (f) Weather protection grade: IP65 Make : Havells, Model : FIORIO
M&L for replacement of Pole Mounted Junction Box 254 x 180 x 111mm, having insulated and made out of thermoplastic Polycarbonate with glass fibre reinforced, rated for Degree of Ingress Protection IP 66 in accordance with IEC 60529, IK 07, weather proof for outdoor installation (with knockouts for cable entry) having Gasket Material shall be Polyurethane and the Gasket shall be internally embedded, Tested at 650°C, with Plastic Mounting Bracket, Din Rail, Mild Steel Flat Iron Clamp, Nuts, Bolts and Washers, with MCB SP 6 Amps, 'B' Curve, 10 KA, complete all as specified and as directed. MAKE: CAPE Electric Model No. TKPS 2518 - 11M or HENSAL cat Pt No. KF 2525B or equivalent.
M&L for replacement of Pole Mounted Junction Box 182 x 180 x 111 mm, having insulated and made out of thermoplastic Polycarbonate with glass fibre reinforced, rated for Degree of Ingress Protection IP 66 in accordance with IEC 60529, IK 07, weather proof for outdoor installation (with knockouts for cable entry) having Gasket Material shall be Polyurethane and the Gasket shall be internally embedded, Tested at 650°C, with Plastic Mounting Bracket, Din Rail, Mild Steel Flat Iron Clamp, Nuts, Bolts and Washers, with MCB SP 6 Amps, 'B' Curve, 10 KA, complete all as specified and as directed. MAKE: CAPE Electric Model No. TKPS 1818 - 11M or equivalent.
M&L for replacement of Connector suitable for fixing of Cable of size Cross sectional area 10 Sqmm to 35 Sqmm armoured/PVC for preventing of Short Circuiting of Cable in Junction Boxes, complete all as specified and as directed. MAKE: HENSAL/ RITTAL/ SCHNEIDER
S&F in repairs Street light junction box made out of 3 mm thick mild steel sheet including applying two coats of synthetic enamel paint over a coat of zinc chrome primer duly spray painted of size not less than 25 cm x 25 cm x 15 cm with locking arrangements inclusive of 20 x 3 mm thick aluminum bus bar 100 amps-04 Nos of suitable length incl MCB SP 5 amp - 01 No, fixed on and including insulators for mounting bus bar (with provision of cable entry and exit conduit), fixed at bottom portion of the pole, fixed with GI bolts, nuts and washers (of suitable size), incl taking down existing junction box complete all as specified and as directed by the Engineer-in-charge.
Dismantling of damage PCC of steel tubular/RCC pole of any size and description and removing the all debris from site after making the new PCC complete all as specified and directed.
Material & Labour for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundation of pole complete all as specified and directed.
Material & Labour for PCC 1:3:6 type C2 using 40mm graded aggregate as in plinth course, string course etc complete including slightly rounded or chamfered for Galvanised steel tubing post for air termination rod including form work etc complete all as specified and directed.
Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed by the Engineer-in-Charge.
M&L for replacement of GI Pipe Bracket made out of Galvanised Iron Tubing 32/40mm bore (dia), light grade, 1.50 Metre long fixed with 02 sets of flat iron clamp of size 25mm x 5 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminum paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed by the Engr-in-Charge.
M&L for replacement of Galvanised Steel Tubing Pipe 40mm bore (dia), Medium Grade, length 0.60 mtr having 50 Cm with long Bends, Each for Incoming and Outgoing Cables, grouting in Cement Concrete, complete all as specified and as directed. NOTE : Cement Concrete will be measured and paid for separately under appropriate Item.
Dismantling of broken/dislodged pre-stressed concrete poles/steel tubular poles, of any description including earthwork for removal of concrete foundation, keeping serviceable poles in safe custody for re-use and removal of unserviceable poles from site, complete all as specified and directed.
Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt as specified type 410 SP-31 (9 Meter long) duly painting with two coats of aluminum paint over a coat of red oxide primer on exposed surface and one coat of black bituminous paint on embedded surface incl writing of Pole Numbers etc., and marking of two black & two yellow strips with synthetic enamel paint upto 1.2 Mtr height and making good disturbed surface complete all as specified and directed.
Erecting of serviceable pre-stressed concrete poles/steel tubular poles (Serviceable steel tubular pole/pre-stressed concrete poles obtained from Item No. 21.00 here-in-before), of any description, with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt etc, including demolition of existing PCC foundation and making good disturbed surfaces complete all as specified and directed. (NOTE: PCC foundation for installation of pole shall be measured separately)
S&F in repair Astronomical time switch with USB key, 2 channel, 240 Volt AC, DIN mounting type suitable for street light operation complete all as specified an directed. (MAKE: HAGER Cat No: EE181 or equivalent model in other makes specified in tender)
S&F in repairs Contactor 40 Amp, 3 module, 2 NO+2NC, Type 1, DIN mounting type suitable for street light operation complete all as specified and directed. (MAKE: HAGER Cat No: ECS442 or equivalent model in other makes specified in tender)
S&F in repairs MCB TPN 63 Amp, 415V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and directed.
S&F in repairs LED Strip light 6 watt, 50 Meter long, 6500 K, warm white, IP 65, 100 lumen per watt, 120 -300 Volt, 50 Hz including electronic driver as IP 65 rating complete all as specified and directed.
M&L for preparation of old painted surfaces of steel tubular poles above PCC coping including cross arms, brackets, pole box and applying two coat of aluminum paint including cleaning of wild vegetation growth/ trimming of tree branches in the vicinity, writing of poles number with sentensile measure white Paint in Black base on steel tubular pole and two black and two yellow strip upto 1.20 metre height with synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted surfaces of pre-cast concrete poles above PCC coping including cross arms, brackets, pole box and applying one coat of samosan paint including cleaning of wild vegetation growth/ trimming of tree branches in the vicinity, writing of poles number with sentensile measure white Paint in Black base on PCC pole and two black and two yellow strip upto 1.20 metre height with synthetic enamel paint complete all as specified and directed.
Taking down of old unserviceable GI steel tubing 40/50 mm bore complete all as specified and directed.
Supply and fixing GI tubing 50mm bore (light grade) for fixing of Post Top lantern complete all as specified and as directed by Engineer-in-Charge.
Material and labour Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron and protected medium grade 40 mm dia 7.5 metre long GI pipe connected to Pole and GI pipe medium grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick and PCC chamber pit with PCC 1:3:6 type C1 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009.
Supply and Fix in repairs, LED Spyke light made with aluminum extrusion, 09 Watts,CCT 3000°K,with UV stabilized injection moulded opal polycarbonate diffuser and degree of protection IP-65, complete all as specified and directed. Cat No BLWUP 09W WW' or equivalent Model of Make 'Philips'/ 'CG']
Repair/ Maintenance LED lights along with driver of Glow sign board at East gate and South gate having letters of " AZADI KA AMRIT MAHOTSAV " and "SWARNIM VIAJY DWAR" both outside and inside gate along with all signatures boards complete cleaning and checking all connections including taking down old Strip light alongiwth driver complete all as specified and directed by Engr-in-charge. Note:- All parts along with replacement of LED light and drivers all included in the above Job quoted rate. No extra cost will be beared by the department at later stage.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
M/S RAJ CONSTRUCTION AND COMPANY
MS HORIZEN
BASU AND CO
R R ENTERPRISE
UNITED ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .