Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹38.9 LAccepted-AOC 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹42.9 L+₹4.0 L (10.3%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L-2 | Rejected-Finance other than lowest bidder | |
| 3 | L-3₹44.1 L+₹5.2 L (13.4%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L-3 | Rejected-Finance other than lowest bidder | |
| 4 | L4₹44.5 L+₹5.6 L (14.4%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L4 | Rejected-Finance other than lowest bidder | |
| 5 | L-5₹45.3 L+₹6.4 L (16.5%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L-5 | Rejected-Finance other than lowest bidder |
| Sl No | Description | Qty | Unit | S B ENTERPRISE L8 | ELECTRO FREEZE L6 | RADHA ENTERPRISE L5 | KWALITY CONSTRUCTION L2 | EASTERN REFRIGERATION AND ELECTRICAL CO L1 | M/S J S ENTERPRISES L4 | SUDHA ENTERPRISES L3 | INDIA ELECTRICAL EQUIPMENTS L7 | ARATI TRADING CO L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Providing maintenance services for summer appliances on daily basis by engaging Refrigerator Mechanic-1 No (Skilled) and Helper-01 No (Semi Skilled) for necessary servicing of Air conditioners, water coolers & refrigerators and carrying out necessary repairs, filling of refrigerent gas, shifting of AC, etc. complete all as specified and as directed.
Note: (i) The above personnel shall have to be present at the MES service centre at HQ BSA/IMH Complex/TV to carryout the work also.
(ii) Any spare parts/refrigerant gas required to be used by the above present shall be measured and paid seperately as "supply only" (iii) Daily Job card shall be issued to the above presonnel by the concerned JE E/M as per requirment at site
(iv) All necessary tools shall be provided by contractor | 30 | Per Day | 2,806 ₹84,180 | 2,760 ₹82,800 | 2,668 ₹80,040 | 2,530 ₹75,900 | 2,300 ₹69,000 Lowest | 2,622 ₹78,660 | 2,599 ₹77,970 | 2,852 ₹85,560 | 2,875 ₹86,250 |
| 2.00 | Supply only AC single phase 230 Volts contactor assembly for 1.5/ 2.0 TR capacity split AC condensing unit complete all as specified and as directed. Make: Carrier/Voltas/LG/Amtex or equivalent as approved by GE | 2 | Each | 1,647 ₹3,294 | 1,620 ₹3,240 | 1,566 ₹3,132 | 1,485 ₹2,970 | 1,350 ₹2,700 Lowest | 1,539 ₹3,078 | 1,526 ₹3,052 | 1,674 ₹3,348 | 1,688 ₹3,376 |
| 3.00 | Supply only Strainer for Split AC of any capacity complete all as specified and as directed. | 2 | Each | 98 ₹196 | 96 ₹192 | 93 ₹186 | 79 ₹158 Lowest | 80 ₹160 | 92 ₹184 | 91 ₹182 | 100 ₹200 | 100 ₹200 |
| 4.00 | Supply only 4 mfd capacitor for blower motor of AC of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | 5 | Each | 86 ₹430 | 84 ₹420 | 82 ₹410 | 77 ₹385 | 70 ₹350 Lowest | 80 ₹400 | 80 ₹400 | 87 ₹435 | 88 ₹440 |
| 5.00 | Supply only 6 mfd capacitor for blower moter of AC of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | 5 | Each | 98 ₹490 | 96 ₹480 | 93 ₹465 | 88 ₹440 | 80 ₹400 Lowest | 92 ₹460 | 91 ₹455 | 100 ₹500 | 100 ₹500 |
| 6.00 | Supply only 36 mfd running capacitor of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | 5 | Each | 549 ₹2,745 | 540 ₹2,700 | 522 ₹2,610 | 495 ₹2,475 | 450 ₹2,250 Lowest | 513 ₹2,565 | 509 ₹2,545 | 558 ₹2,790 | 563 ₹2,815 |
| 7.00 | Supply only 40 mfd running capacitor of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | 5 | Each | 610 ₹3,050 | 600 ₹3,000 | 580 ₹2,900 | 550 ₹2,750 | 500 ₹2,500 Lowest | 570 ₹2,850 | 565 ₹2,825 | 620 ₹3,100 | 625 ₹3,125 |
| 8.00 | Supply only 50 mfd running capacitor of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | 5 | Each | 671 ₹3,355 | 660 ₹3,300 | 638 ₹3,190 | 605 ₹3,025 | 550 ₹2,750 Lowest | 627 ₹3,135 | 622 ₹3,110 | 682 ₹3,410 | 688 ₹3,440 |
| 9.00 | Supply only 100-120 mfd Starting capacitor of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | 5 | Each | 793 ₹3,965 | 780 ₹3,900 | 754 ₹3,770 | 715 ₹3,575 | 650 ₹3,250 Lowest | 741 ₹3,705 | 735 ₹3,675 | 806 ₹4,030 | 813 ₹4,065 |
| 10.00 | Supply only Sensor for 1.5/ 2.0 TR capacity Split type AC complete all as specified and as directed. | 5 | Each | 732 ₹3,660 | 720 ₹3,600 | 696 ₹3,480 | 660 ₹3,300 | 600 ₹3,000 Lowest | 684 ₹3,420 | 678 ₹3,390 | 744 ₹3,720 | 750 ₹3,750 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Apr 2026, 6:00 pmClosed
Garrison Engineer Alipore
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR/ RENEWAL TO VARIOUS TYPES OF SUMMER AND WINTER APPLIANCES AT TURF VIEW COMPLEX, IMH COMPLEX, BSA and GOKHALE ROAD COMPLEX UNDER GE ALIPORE
2026_MES_758758_1
GE/ALP (8656) KOLKATA OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Alipore
Class D category b (i)
10 documents required · 10 mandatory
₹500
Garrison Engineer Alipore
₹80,000
Yes
Garrison Engineer Alipore
1 Jun 2026
31 Mar 2026
23 Apr 2026
31 Mar 2026
21 Apr 2026
14 Apr 2026
31 Mar 2026 - 7 Apr 2026
8 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Providing maintenance services for summer appliances on daily basis by engaging Refrigerator Mechanic-1 No (Skilled) and Helper-01 No (Semi Skilled) for necessary servicing of Air conditioners, water coolers & refrigerators and carrying out necessary repairs, filling of refrigerent gas, shifting of AC, etc. complete all as specified and as directed.
Note: (i) The above personnel shall have to be present at the MES service centre at HQ BSA/IMH Complex/TV to carryout the work also.
(ii) Any spare parts/refrigerant gas required to be used by the above present shall be measured and paid seperately as "supply only" (iii) Daily Job card shall be issued to the above presonnel by the concerned JE E/M as per requirment at site
(iv) All necessary tools shall be provided by contractor | - | Per Day | - | - |
| - | Supply only AC single phase 230 Volts contactor assembly for 1.5/ 2.0 TR capacity split AC condensing unit complete all as specified and as directed. Make: Carrier/Voltas/LG/Amtex or equivalent as approved by GE | - | Each | - | - |
| - | Supply only Strainer for Split AC of any capacity complete all as specified and as directed. | - | Each | - | - |
| - | Supply only 4 mfd capacitor for blower motor of AC of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | - | Each | - | - |
| - | Supply only 6 mfd capacitor for blower moter of AC of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | - | Each | - | - |
| - | Supply only 36 mfd running capacitor of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | - | Each | - | - |
| - | Supply only 40 mfd running capacitor of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | - | Each | - | - |
| - | Supply only 50 mfd running capacitor of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | - | Each | - | - |
| - | Supply only 100-120 mfd Starting capacitor of any capacity complete all as specified and as directed.
Make: Sarda/ Universal/Tibcon motor or equivalent as approved by GE | - | Each | - | - |
| - | Supply only Sensor for 1.5/ 2.0 TR capacity Split type AC complete all as specified and as directed. | - | Each | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_849877.xls
BOQ • 1.03 MB
tenderdoc.pdf
Tender Documents • 0.96 MB
sch.pdf
Additional Documents • 0.20 MB
corrigendum_8656.pdf
PDF • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .