Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | Admitted-Finance |
| 2 | Admitted-Finance 194 IIND FLOOR POCKET 9 SECTOR 24 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | Admitted-Finance |
| 3 | Admitted-Finance 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | Admitted-Finance |
| 4 | Admitted-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | Admitted-Finance |
| 5 | Admitted-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | Admitted-Finance |
Tender Value
₹46.6 L
EMD Value
₹93,260
Closing Date
23 Sept 2024, 6:00 pmClosed
GE (South West)
GE (South West) New Delhi-03
REPLACEMENT OF BER INCINERATOR AND ITS CONNCTED ASSOCIATED WORK AT ARC MAHIPALPUR, PROVN OF ELECTRIC INCINERATOR AND ITS CONNECTED ASSOCIATED WORK AT TAG, PROVN OF AIR WASHER SYSTEM FOR KITCHEN OF MAIN CANTEEN AT MBC AND PROVN OF INLINE AXIAL FAN IN
2024_MES_662365_1
GE/SW-36/2024-25
Limited
Electrical and Maintenance Works
Item Rate
180 days
GE (South West) New Delhi
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE (South West) New Delhi
₹93,260
Yes
25 Sept 2024
2 Sept 2024
25 Sept 2024
2 Sept 2024
23 Sept 2024
16 Sept 2024
Amount
M&L for Dismantling unserviceable diesel fired incinerator complete with all connected associated items/ parts care fully after disconnecting all electrical and mechanical connection in and including RCC/PCC base and removing of scrap and debris rubbish from site before installation of new incinerator. Dismantling material will be properties of contractor under schedule of credit. The dismantling wherever required shall be done in a manner so that no other portion of the building or its fixtures is damaged. If any damages are done, it will be made good by the contractor at his own cost. Rate for transportation and labour for removing scrap material & debris deemed including in this item complete all as specified and as directed by Engr-in-Charge.
Supply, install, commissioning and testing of ELECTRIC incinerator having 50KG per day burning capacity horizontal/vertical type comprising of heater power 3000w with sensor safety cut off SS burning chamber insulated with ceramic materials with door fitted with hinges and handles for proper sealing to avoid heat loss having top loading opening with automatic timer cut off , including all other accessories and piping, equipments and civil works required for installation of incinerator chimney complete all as specified.
Excavation in trenches n.exc 1.5 m wide and not exc 1.5 m depth and getting out in soft and loose soil complete all as specified and directed.
Returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Removal of surplus excavated material of any type not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for Sand cushioning/sand covering for underground cable protection complete all as specified. Note: Punned thickness only will be measured and paid.
Supply and laying sub class 'B' bricks of old size (approved size locally available) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engr-in-Charge.
Supply & lay GI tubing light grade, 25 mm dia, fixed to wall/on poles or laid at road crossing for protection of cable.
Supply and laying or fixing or passing through pipe or in cable ducts and Testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm,4 core complete all as specified and as directed.
Supply & Fixing in replacement of sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP 25Amp of capacity 20P+E Amps complete and making good disturbed surface all as specified and directed.
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1, using (20mm graded stone aggregate), "mild steel angle iron frame" made out of MS angle iron of size 40x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No 3" and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing as directed.
Supply, install, commissioning and testing of ELECTRIC incinerator having 50KG per day burning capacity horizontal/vertical type comprising of heater power 3000w with sensor safety cut off SS burning chamber insulated with ceramic materials with door fitted with hinges and handles for proper sealing to avoid heat loss having top loading opening with automatic timer cut off , including all other accessories and piping, equipments and civil works required for installation of incinerator chimney complete all as specified, Make SRI adhava power industries Cat part no SAPI Burn 3.5 or equivalent
Supplying and laying reinforced precast concrete cable cover, class LV, type 1with peak, size 250mm x 150mm x 40mmcomplete all as specified and directed.
Supply & Fixing in replacement of sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP 25Amp of capacity 20P+E Amps complete and making good disturbed surface all as specified and directed. Make : Legrand/ Schneider/ Hager/ Simens
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI strip 32 x 6mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 15 mm bore light grade for protection of earthing wire PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, watering pipe 20mm bore light grade, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR part-I and including excavation & earth work & connecting the earthing point/equipment and testing complete.
Supply, installation, commissioning and testing of Evaporator type, industrial Air Washer Unit 9000 CFM with 50 mm WG static pressure having double skin PUF insulated housing made out of powder coated GI sheet (22/24 SWG), horizontal type, floor mounted with C channel and MS sheet not less than 5mm thick base frame of suitable size duly painted with two coat of anti corrosive black bituminous paint, SS 304 water tank with provision of Inlet and outlet water connection for 25 mm dia pipe and bottom drain connection with control valve, centrifugal DIDW backward curved blower with fan 500mm size, duly static and dynamically ballaced low noise, TEFC squirel cage induction motor, 5.5 KW, 4 pole, IP 55 protected, VFD compatible (make: Siemens / CG /ABB/Havells), Monoblock pumpset 1 Hp for water circulation with GI medium grade water piping, Aluminium metallic filters 10 micron in G.I frame, 200 mm thick evaporative cooling pad made out of Cellulose sheet in 7mm flute size, Fire proof double layered flexible connections for each outlet complete with flanges made out of 20G G.S.S sheet on both sides for connection to air washer and duct complete with GI nuts, bolts & washer etc, Vibration isolation pads below air washer in and including connecting all electrical/water and air duct connections in existing system and testing complete all as specified and as directed by Engr-in-Charge.
Supply, laying and testing cable XLPE insulated, screened PVC bedded, FRLS, armoured electric power cables (heavy duty), 1100 volts grade with stranded copper conductor conforming to IS - 7098 Pt - I of 10 Sqmm, 4 core in existng trench complete all as specified and as directed by Engr-in-Charge.
Supply, installation, balancing, testing and commissioning of site fabricated GI sheet metal rectangular/ round ducting complete with neuperene rubber gaskets, elbows, bends, slip on flanges, GI thread rod, vanes, and including MS channels, girder supports and cutting of existing duct as directed by Engineer in charge including making of hole in any type of wall and making good with plastering work, masonry work using 22 gauge (0.80mm ) thickness GI Sheet complete all as specified and as directed.
M&L for fabrication air grill with fins made out of 18 SWG GI sheet as per size and shape or as directed by the Engr-in-Charge, fixing on wall/ ceiling with fixing arrangements as per site requirement including two coats of synthetic enemal white paint over one coat of metal primer all as directed.
Supplying, laying and jointing/connecting GI water tubing, 15 mm dia, medium grade with all necessary accessories specials viz socket, bend, tee, unions, cross, elbows, nipple short piece etc. jointing materials, cutting pipes, making threads with screwed and socketed joints and fixed complete in trenches, wall, ceiling or laid in floor complete all as specified and directed by Engr-in-Charge.
Supply, Installation, Testing & Commissioning of duct mounted cabinet type inline axial fan complete with belt/direct driven centrifugal blower/impeller, motor, rubber Isolation mount & other accessories including internal wiring with PVC insulated multi stranded copper conductor cable of suitable size drawn through PVC conduit complete in all respects in existing duct and cutting of existing duct, frame work on which fan mounted, nut bolt, studs as required at site included in rate. The casing shall be internally acoustically lined and constructed of galvanized steel of 22 SWG thick. The inline fans motor shall be single phase, 230/240 Volt, 50 Hz and lower noise level. Inline fans motor shall have inbuilt speed controller NC level 3M away from source should be less than 50 db, of capacity 2000 CFM @ static pressure 35 mm wg as directed by Engr-in-Charge.
Supply, Installation, testing and balancing of Supply Zero Leakage Air Duct dampers duly fabricated with G.I Sheet of 22 gauge and duly painted with two coat of synthetic enamel paint.
Supply and fixing PVC insulating, multi stranded copper conductor cable, 1100 V grade, 3 core, 2.5 mm size drawn through in and including PVC conduit medium grade with all accessories and fixing material in and including 8 SWG Copper wire for earth continuity conductor.
Supply and fixing wheather proof sheet metal enclosure, SPN, 2 way with MCB, SPN, 16 Amp, 10 KA for each inline fan motor.
Dismantling and shifting of existing 42U rack including services with all accessories from 1st floor Server room to 2nd floor Server room.
Dismantling and shifting of existing 24 port LAN switches with mounting rack from existing rooms at 1st floor to 2nd floor
Dismantling and shifting of existing power DBs and power sockets from existing rooms at 1st floor to 2nd floor
Dismantling of existing wiring (Elect, Cat6, Fiber, Telephone)
Dismantling of existing GI Tray
Dismantling and shifting of existing UPS plants from existing room at 1st floor to 2nd floor.
Dismantling and shifting of existing battery bank from existing room at 1st floor to 2nd floor
Dismantling and shifting of existing MUX units with accessories from existing room at 1st floor to 2nd floor
Dismantling and shifting of existing MDF from existing room at 1st floor to 2nd floor
Installation, commissioning and testing of 42U rack including servers with all accessories at 2nd floor
Installation, commissioning and testing of Layer 2 POE based switches having 24 ports at 2nd floor
Installation, commissioning and testing of UPS plants with battery banks at 2nd floor
Installation, commissioning and testing of MUX units with accessories at 2nd floor
Installation, commissioning and testing of Power DBs and power sockets units at 2nd floor
Installation, commissioning and testing of D-link car 6 cable
Installation, commissioning and testing of D-Link Cat 6, IO face plate with SMB
Installation, commissioning and testing of D-Link 24 port patch panel Cat 6 UTP key stone 24 port loaded of installation
Installation, commissioning and testing of 2 core fiber cable
Installation, commissioning and testing of SC-LC Duplex fiber patch cord SM-9/125UM-3m
Installation, commissioning and testing of PVC conduit pipe 25 mm
Installation, commissioning and testing of 150 mm cable tray fixing of installation
Installation, commissioning and testing of PVC Dalton 2 pair 0.5 mm cable of laying of termination
Installation, commissioning and testing of 02 x Chemical earthing pit
Supply of D-link Cat 6 cable (01 Roll =343 RM)
Supply of D-link Cat 6 IO face plate network key stone jack gang box with SMB
Supply of D-link 24 port patch panel Cat 6 UTP key stone - 24 port loded
Supply of 2 core fiber cable
Supply of PVC conduit pipe 25 mm
Supply of PVC Dalton 2 pair 0.5mm cable
Supply of SC-LC Duplex fiber patch cord SM-9/125UM - 3M
Supply of 150mm cable tray
Supply of copper plate for earthing electrode (50mm x8mm) 3 meter each
Supply of 25mm x 3mm copper strip with accessories
Taking out Split type AC of 1.0/1.5/2.0 TR capacity, of any type/make, at site/ wall, comprising of taking down carefully, removing power connections/ out door unit and refixing including gas charging/testing complete all as specified and as directed.
M&L point wiring for Modular Switches concealed conduit complete with 1.5 Sqmm, single core, multistranded copper conductor PVC insulated FRLS cable 1100 Volts grade, drawn through concealed conduit and including rigid non-metalic of suitable size of PVC conduit, including replacement of top modular cover plate, Sunken Box & Face plate etc as per site requirement and including 1.5 sqmm size multistranded FRLS PVC insulated copper earth continuity conductor to common earth dolly for one light/fan point controlled by one switch 6 Amps one way single pole complete all as specified and directed.
All as per item No. 60 above but three pin 6 Amps socket out let on independent board.
All as per item No. 60 above but three pin 6 Amps socket out let on same board .
All as per item No. 60 here-in-before but point wiring with 2.5 Sqmm single core FRLS PVC insulated cables and earth continuity wire with 2.5 Sqmm single core cable for one 3 pin 16 Amps sockets outlet point on independent board.
S&F in replacement of Socket Modular type 6/16 A, 2/3 pin 2 Module, 230 Volts.
S&F in replacement of Socket Modular type 6 A, 2/3 pin 2 Module, 230 Volts.
S&F Switch Modular type 6 A, 230 Volts one way single Module.
S&F Switch Modular type 16 A, 230 Volts one way single Module.
S&F in replacement of Modular fan step regulator, 1 Module, 100 W, 230 Volts, flush type complete all as specified and directed.
M&L in replacement of Sub Main wiring with 2 x 2.5 Sqmm, single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in walls and clamped on surface at RCC portions etc including 2.5 Sqmm size FRLS PVC insulated Copper earth continuity conductor to common earth and connecting to earth dolly for AC/Power point including drilling holes and making good to disturbed surfaces.
M & L in replacement of Sub Main wiring with 2 x 4 Sqmm, single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in walls and clamped on surface at RCC portions etc including 4 Sqmm size FRLS PVC insulated Copper earth continuity conductor to common earth and connecting to earth dolly for AC/Power point including drilling holes and making good to disturbed surfaces.
M & L in replacement of Sub Main wiring with 2 x 6 Sqmm single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in any type of wall or clamped on surface at RCC portions etc including 6 Sqmm size FRLS PVC insulated copper earth continuity conductor to common earth and connecting to earth dolly for AC/Power point including drilling holes and making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
M & L in replacement of Sub Main wiring with 2 x 10 Sqmm, single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in walls and clamped on surface at RCC portions etc including 10 Sqmm size FRLS PVC insulated copper earth continuity conductor to common earth and connecting to earth dolly for AC/Power point including drilling holes and making good to disturbed surfaces.
S & F in replacement LED Recess Mounted 2 x 2 Feet Luminaries fittings LED, 36 Watt, White/Worm White Colour, cast Aluminium housing, toughened glass, Silicon gasket, pre-wired and electric connection with suitable size stranded copper flexible PVC insulated wire including clamps etc complete all as specified and directed.
M & L for Sub Main wiring with 4 x 6 Sqmm single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in any type of wall or clamped on surface at RCC portions etc including 6 Sqmm size FRLS PVC insulated copper earth continuity conductor to common earth and connecting to earth dolly for 3-phase machine connection including drilling holes and making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
M & L for Sub Main wiring with 4 x 10 Sqmm single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in any type of wall or clamped on surface at RCC portions etc including 10 Sqmm size FRLS PVC insulated copper earth continuity conductor to common earth and connecting to earth dolly for 3-phase connection including drilling holes and making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
M & L for Sub Main wiring with 4 x 25 Sqmm single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in any type of wall or clamped on surface at RCC portions etc including 25 Sqmm size FRLS PVC insulated copper earth continuity conductor to common earth and connecting to earth dolly for 3-phase connection including drilling holes and making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
S & F in replacement of Ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 volts, 1200 mm sweep, 5 star rated complete all as specified and directed. Note: Old U/s fan will be deposited to E/M Store Yard.
S & F of Exhaust Fan made up of Sturdy Engineering Plastic complete with louvers, shutter, AC, single phase, 230 Volts, 50 Hz, RPM 1200, Copper winding of sweep 250 mm including fixing on any type of window with suitable size of Ply board, nut-bolts and washers etc according to site requirement complete all as specified and directed. Note: Old U/s fan will be deposited to E/M Store Yard.
S & F in replacement of Exhaust Fan, Steel Body, AC single phase 230 Volts, Copper Winding of size 380 mm sweep, heavy duty with blades, frame and louvers etc including fixing on any type of window with suitable size of Ply board, nut-bolts & washers etc according to site requirement complete all as specified and directed. Note: Old U/s fan will be deposited to E/M Store Yard.
S&F in replacement Sheet Metal Enclosure with Industrial with two pin and earth plug and socket suitable for AC connection complete with one Single Pole MCB of 20 Amp Capacity complete all as specified and directed.
S&F of Sheet Metal Enclosure Sub Main Distribution Box 12 Way , double door complete all as specified and directed.
S & F of MCB 4P 415 Volts, 63 Amps Complete all as specified and directed.
S & F of MCB 3P 415 Volts, 63 Amps Complete all as specified and directed.
S & F of MCB DP 240 Volts, 40 Amps Complete all as specified and directed.
S & F of MCB DP 240 Volts, 63 Amps Complete all as specified and directed.
S & F of MCB SP 240 Volts, 16 to 32 Amps Complete all as specified and directed.
S & F of MCB SP 240 Volts, 40-63 Amps Complete all as specified and directed.
Labour for Laying of Cat-6 LAN Cable/Tele Cable and passing through with new 20 mm PVC conduit with all standard accessories complete all as specified and directed.
S & F in replacement of Exhaust Fan, Steel Body, AC single phase 230 Volts, Copper Winding of size 300 mm sweep, heavy duty with blades, frame and louvers etc including fixing on any type of window with suitable size of Ply board, nut-bolts & washers etc according to site requirement complete all as specified and directed. Note: Old U/s fan will be deposited to E/M Store Yard.
S&F in replacement of Wall Mounted fans complete with all standard accessories, 230 V, 400 mm sweep complete all as specified and directed. Note: Old U/s fan will be deposited to E/M Store Yard.
S & F in replacement of Flexi Strip LED 12V, Worm White Colour as per sample given complete all as specified and directed.
S & F of Flexible PVC Copper Cable of 2.5 Sqmm 3 core multistranded copper conductor suitable for 1100 Volts grade including fixing on any type of wall with suitable size of GI saddle, nut-bolts and washers etc complete all as specified and directed.
Taking down Re-fixing/ Re-laying of XLPE insulated PVC inner sheathed armoured copper conductor multistranded 1100 V grade, 1.5 Sqmm 2 Core Cable including fixing on any type of wall with suitable size of GI saddle, nut-bolts and washers etc complete all as specified and directed.
Taking down carefully and re-fixing /re-installation of smoke Detectors Complying with and type certified to EN-45 Addressible type smoke detector Photoelectric/ Optical wirh base with self built intelligence and PVC base box type complete all as specified and directed.
Supply & Installation of Electric Water Heater, Geyser 25 Litre capacity, storage type, Steel body with copper inner tank and heating element upto 2 KW capacity, Single phase, 230 Volts, energy saving, BEE 5 Star rated complete with all standard accessories such as safety valve, thermostate, NRV, suitable size of Hot & Cold water connecting pipe of adequate length complete all as specified and as directed.
S&F in replacement of 12V, 24W, LED Strip driver suitable/ compatible for 12V LED Flexi Strip Worm White Colour including shouldering with AL wire with strip complete all as specified and as directed.
R R Associates (BID ID -3097254)
Vishal Traders (BID ID -3103988)
Rahul Enterprises (BID ID -3108194)
SANJEEV ENTERPRISES (BID ID -3107885)
GLIBS CONSTRUCTION (BID ID -3107449)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .