Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 CrAccepted-AOC 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹3.8 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹3.9 Cr+₹10.6 L (2.82%)Rejected-Finance | ₹3.9 Cr+₹10.6 L (2.82%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹3.9 Cr+₹16.6 L (4.41%)Rejected-Finance JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | ₹3.9 Cr+₹16.6 L (4.41%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹4.2 Cr+₹45.8 L (12.2%)Rejected-Finance | ₹4.2 Cr+₹45.8 L (12.2%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹4.3 Cr+₹50.5 L (13.4%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹4.3 Cr+₹50.5 L (13.4%) | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | R D Bansal L6 | vijay builders L1 | V K Sales and Construction Co L3 | GEPS PROJECTS L5 | Shekhar Enterprises L7 | Electromechanics Engineers & Contractors L4 | PROACH ASSOCIATES BUILDERS & ENGINEERS L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Sch 'A' Part-I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only. | ||||||||||
| 1.01 | Construction of block of Panel room/ duty room complete all as shown on drawings and as specified. | 1 | Each Block | 49,00,000 ₹49,00,000 | 36,00,000 ₹36,00,000 | 27,60,000 ₹27,60,000 | 60,000 ₹60,000 Lowest | 45,80,000 ₹45,80,000 | 47,50,000 ₹47,50,000 | 44,11,587 ₹44,11,587 |
| 2.00 | Total Amount of Sch 'A' Part -II (Internal Water Supply Work) | 1 | Lump Sum | 15,700 ₹15,700 | 23,412.53 ₹23,412.53 | 20,910 ₹20,910 | 30,000 ₹30,000 | 20,904.03 ₹20,904.03 | 15,000 ₹15,000 Lowest | 27,000 ₹27,000 |
| 3.00 | Total Amount of Sch 'A' Part -III (Internal Electric Supply Work) | 1 | Lump Sum | 94,000 ₹94,000 Lowest | 1,05,071.25 ₹1,05,071.25 | 1,13,500 ₹1,13,500 | 1,50,000 ₹1,50,000 | 1,10,325 ₹1,10,325 | 98,000 ₹98,000 | 1,10,000 ₹1,10,000 |
| 4.00 | Total Amount of Sch 'A' Part -IV (Plumbing Work) | 1 | Lump Sum | 10,480 ₹10,480 | 14,065.95 ₹14,065.95 | 1,190 ₹1,190 Lowest | 18,000 ₹18,000 | 9,377.3 ₹9,377.3 | 9,200 ₹9,200 | 14,000 ₹14,000 |
| 5.00 | Total Amount of Sch 'A' Part - V (External Electric Supply Work) | 1 | Lump Sum | 10,48,000 ₹10,48,000 | 12,55,213.62 ₹12,55,213.62 | 1,25,025 ₹1,25,025 | 1,20,000 ₹1,20,000 | 12,22,468.91 ₹12,22,468.91 | 9,12,000 ₹9,12,000 | 98,000 ₹98,000 Lowest |
| 6.00 | PROVISIONAL SUM
A provisional sum of Rs. 18,38,000.00 for construction of overhead steel structure for passing of electric power cable complete; the height of the steel structure work for bridge is upto 10m, width upto 2m and span upto 30m including foundation, complete all as specified and directed by GE. | 1 | Lump Sum | 29,20,000 ₹29,20,000 | 22,05,600 ₹22,05,600 | 21,66,100 ₹21,66,100 | 24,00,000 ₹24,00,000 | 28,03,420 ₹28,03,420 | 16,00,000 ₹16,00,000 Lowest | 34,96,700 ₹34,96,700 |
| 7.00Sch 'A' Part - VI (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only. | ||||||||||
| 8.00 | Supply, installation, commissioning & testing outdoor type Power transformer having no load voltage ratio at rated voltage 33KV/11 KV, 3150 KVA, oil immersed, naturally cooled 3 phase 50Hz, vector group DYN-11 and ON Load tap Changer with AVR & RTCC +5% to -15% in step of 1.25% tap changing switch on HT side to very secondary voltage, connected internally and hand operated ON Load tap changing switch, star Delta connected internally with HV coil, copper double wound, LV side provided with 3 phase and neutral with the temperature rise not exceeding 50 degree Celsius by thermometer in oil and 55 degree Celsius by resistance with first filling of oil as per IS grade 335 and transformer conforming to IS 2026 "class A" all as directed and specified. Painting process should be done in environment friendly painting with heaters for curing of paint. The following fittings and accessories including first fill of transformer oil, necessary mounting on PCC floor mounted as per manufacturer's recommendations and specifications.
(Contd....../) | 1 | Each | 71,50,000 ₹71,50,000 | 53,00,000 ₹53,00,000 Lowest | 84,99,000 ₹84,99,000 | 70,50,000 ₹70,50,000 | 71,00,000 ₹71,00,000 | 75,11,302 ₹75,11,302 | 69,80,000 ₹69,80,000 |
| 8.01Transformer shall be provided with the following:- (a) Lifting lugs, Top cover lugs & jacking Pad. (b) Earthing Terminals. (c ) Conservator with oil gauge Glass, Oil filling hole with plug and drain plug. (d) Transformer Drain valve (e) 04 No Bi-directional plain/Flat rollers (f) Explosion Vent with Diaphragm (g) Thermometer Pocket (h) Air Vent Plug (j) First Fill Silica get Breather (k)Rating&Diagram Plate,Inspection cover,Terminal Making Plate (l) Cooling Radiators m) HT Termination - Bare Bushing. n) Provn of LT Termination box for connecting LT output through rated cables etc. as catered in CCE work provisions complete all as drawings approved by GE. (Contd....../) | ||||||||||
Tender Value
₹4.9 Cr
EMD Value
₹5.6 L
Closing Date
20 Dec 2025, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone, PIN-900386, C/O 56 APO
PROVN OF POWER TRANSFORMER AND CONNECTED INFRASTRUCTURE UNDER GE (U) UDHAMPUR
2025_MES_739640_1
87985-A/E8
Open Tender
Electrical and Maintenance Works
Lump-sum
456 days
Udhampur
As per NIT
8 documents required · 8 mandatory
₹2,000
GE (U) Udhampur
₹5.6 L
Yes
HQ Chief Engineer Udhampur Zone
13 Mar 2026
13 Nov 2025
23 Dec 2025
13 Nov 2025
20 Dec 2025
15 Dec 2025
14 Nov 2025 - 24 Nov 2025
25 Nov 2025
Point wiring complete with 2.5 sqmm PVC insulated, FRLSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc; modular metal flush box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick including modular top cover plate as per numbers of switch modules for fixing of modular switches, sockets, fan regulators, red colour indicator, blank plates etc. as approved colours and including 2.5 Sqmm PVC insulated multistranded FRLSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- Note:- All necessary accessories such as modular steel box, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used same make/brand only.
Lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings including 12 watt LED lamp, complete all as specified and directed.
Sch 'A' Part - VI (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Total Amount of Sch 'A' Part -III (Internal Electric Supply Work)
Total Amount of Sch 'A' Part -IV (Plumbing Work)
Construction of block of Panel room/ duty room complete all as shown on drawings and as specified.
Transformer shall be provided with the following:- (a) Lifting lugs, Top cover lugs & jacking Pad. (b) Earthing Terminals. (c ) Conservator with oil gauge Glass, Oil filling hole with plug and drain plug. (d) Transformer Drain valve (e) 04 No Bi-directional plain/Flat rollers (f) Explosion Vent with Diaphragm (g) Thermometer Pocket (h) Air Vent Plug (j) First Fill Silica get Breather (k)Rating&Diagram Plate,Inspection cover,Terminal Making Plate (l) Cooling Radiators m) HT Termination - Bare Bushing. n) Provn of LT Termination box for connecting LT output through rated cables etc. as catered in CCE work provisions complete all as drawings approved by GE. (Contd....../)
(m) LV Neutral Bushing brought out for external earthing. (n) First Fill of EHV grade Transformer Oil (o) Buchholz Relay with Contracts for Alarm & Trip Contacts (p) Magnetic Oil Level Gauge with Alarm Contacts (q) Oil Temp indicator with Alarm & Trip Contacts (r) Winding Temperature indicator with Alarm & Trip Contacts (s) Marshaling Box) (t) No Load Losses- 4.0kw (max.) (t) No Load Losses- 25.0kW (max.)
Supplay, laying & testing cable HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power (heavy duty) with stranded aluminium conductor, 33000 volts grade of size 150 sqmm, 3 core, laid in trench/ on surface of wall complete all as specified and directed.
Supplay, laying & testing cable HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 150 sqmm, 3 core, laid in trench/ on surface of wall complete all as specified and directed.
Supply, installation, commissioning & testing outdoor type Power transformer having no load voltage ratio at rated voltage 33KV/11 KV, 3150 KVA, oil immersed, naturally cooled 3 phase 50Hz, vector group DYN-11 and ON Load tap Changer with AVR & RTCC +5% to -15% in step of 1.25% tap changing switch on HT side to very secondary voltage, connected internally and hand operated ON Load tap changing switch, star Delta connected internally with HV coil, copper double wound, LV side provided with 3 phase and neutral with the temperature rise not exceeding 50 degree Celsius by thermometer in oil and 55 degree Celsius by resistance with first filling of oil as per IS grade 335 and transformer conforming to IS 2026 "class A" all as directed and specified. Painting process should be done in environment friendly painting with heaters for curing of paint. The following fittings and accessories including first fill of transformer oil, necessary mounting on PCC floor mounted as per manufacturer's recommendations and specifications. (Contd....../)
1100 Volts PVC insulated FRLSH copper conductor control armoured cable shall comply with standards as IS 1554 (partI and partII) PVC Insulated heavy duty electric cable, IS 5831, PVC insulation and sheath of electric cable, is 8130 conductor for insulated electric cable and cords, IS 3961 current rating of cable, IS 502 extended solid dielectric insulated power cable for rated voltage from 1KV to 30KV, IEC 540 and 540A test methods for insulation and sheath of electric cable and cords, IEEE 383 standard for type test for class II electric cable field splices and connections, swedish standard and SS 424 1475 Class F3 for flammable test, IEC 332-1 test on electric cable under fire condition, IEC 754 -1 test method for acid generation, ASTMD-2863 oxygen index test and temperature index test NEMA WC5 for accelerated water absorption test and dielectric strength retention test construction of cable shall be such that the PVC fillers will be used to provide uniform circular cross section before the inner sheath is applied. All material shall comply the applicable provisions of the test mentions in the specifications mentioned above, current rating and derating factors under normal conditions of installation shall be as per latest amendment IS-3961 (Part-II) of size 2.5sqmm, 12 core, armoured complete all as specified and directed.
Note-: 1) The pannel shall be front operatded with cable entry from the bottom with cable glands. The fault with standing Capacity shall be 50 KA & earth bus shall be part of the LT panel. (2) Earth work and construction of platform for panel, brick masonary in cement mortar 1:6 with foundation PCC 1:48 (type D-2) including plaster work, PCC coping 1:2.4 (20mm graded crushed stone aggregate).
Note-: 1) The pannel shall be front operatded with cable entry from the bottom with cable glands. The fault with standing Capacity shall be 50 KA & earth bus shall be part of the LT panel. (2) Earth work and construction of platform for panel, brick masonary in cement mortar 1:6 with foundation PCC 1:48 (type D-2) including plaster work, PCC coping 1:2.4 (20mm graded crushed stone aggregate).
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sqmm, single core complete all as specified and directed
easurement purpose punned thickness 18cm shall be considered.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Drg5_compressed.pdf
Additional Documents • 0.62 MB
Drg6_compressed.pdf
Additional Documents • 0.80 MB
TENDER_compressed.pdf
Tender Documents • 1.02 MB
Drg1_compressed.pdf
Additional Documents • 0.93 MB
Drg2_compressed.pdf
Additional Documents • 4.39 MB
Drg3_compressed.pdf
Additional Documents • 1.87 MB
Drg4_compressed.pdf
Additional Documents • 0.96 MB
BOQ_828186.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .