CWE (A) Jaisalmer
HQ CWE ARMY JAISALMER 345001 RAJASTHAN
PROVN OF OTM ACCN FOR WMP FOR PROVOST UNIT AT JAISALMER UNDER GE (A) JAISALMER.
2025_MES_712132_1
84320/C/E8
Open Tender
Civil Works
Item Rate
180 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (A) Jaisalmer
₹87,000
Yes
30 Jul 2025
3 Jun 2025
2 Jul 2025
3 Jun 2025
30 Jun 2025
18 Jun 2025
3 Jun 2025 - 9 Jun 2025
Amount
B&R WORK Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, laying of cable/pipe, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft / disintegrated rock complete all as specified and directed by Engineer-in-Charge.
Excavating in trenchs, n exc 1.5m wide and exc 1.5m but n exc 3.0m in depth; for foundation, laying of cable/pipe or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft / disintegrated rock complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated soft / disintegrated rockmaterial to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore broken to stone or boulders gauge exc 63 mm and n. Exc. 100mm deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled / rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 (Type D2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footing foundation beams, plinth beam, base for coulm, etc basement slab under ream piles and mass complete all as specified and directed by Engineer-in-Charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in Column, Pillars post and struts etc complete all as specified and directed by Engineer-in-Charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in beams, cantilever, bressummers, lintel over 1.5m span etc complete all as specified and directed by Engineer-in-Charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs andd in shelves and the like complete all as specified and directed by Engineer-in-Charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of concrete foundation, footing, base of column, raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter to rough finish surface of concrete flat complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs ,floor slabs ,landing and similar work not exc 200mm thick (Horizontal or sloping) to rough finish surface of concrete flat. complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of floor or roof beams, beam haunching, grider, bressumber, lintels, cantilever, sleves including supports ,over hang etc also splay between floor and beams to rough finish surface of concrete flat. complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of pillars, posts, struts piers, columns and stanchion to rough finish surface of concrete square, rectangular or polygonal. complete all as specified and directed by Engineer-in-Charge.
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. complete all as specified and directed by Engineer-in-Charge.
Formwork to edges of finished surface of concrete flats ,treads, break in floors window cills, concrete railing , opening in concrete wall, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide to rough finish surface of concrete flat. complete all as specified and directed by Engineer-in-Charge.
M&L for TMT mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and directed by Engineer-in-Charge.
M&L for TMT mild steel bars 6 to 8mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 21.00 here-in-before above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engineer-in-Charge.
M&L for squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with fly ash bricks modular brick size straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10 mm thick cement plaster in CM 1:6 on fair faces of brick/concrete work surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm tk on fair faces of concrete surface in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10 mm thick cement plaster in CM 1:4 on fair faces of brick/concrete work surfaces finished even and smooth without using extra cement including water proofing compound complete all as specified and directed. Note : water proofing compound will be measured and paid seperately under relevant item.
Supply only integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of newly plaster surface and applying three coat of white wash on newly plaster surface of ceiling complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of newly plaster surfaces of wall and applying two coats of cement based paint over one coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of newly plaster surfaces on wall and apppying of two coat of oil bound distemper over 1mm thick wall care putty complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C1 using 40 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of flooring complete all as specified and directed by Engineer-in-Charge.
M&L for non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes like tiles etc complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed coloured ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including rendering 10 mm thick cement plaster in CM 1:4 for fixing vertical tiles complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including screed bed or bedding layer of 15 mm thick in CM (1:6) complete all as specified and as directed by the Engineer-in-Charge.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar and laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick backing coat in CM (1:4) complete all as specified and as directed by the Engineer-in-Charge.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290.Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
S&F Pressed steel frames made of MS sheet of 1.20mm thickness of size 105 x 60 mm for doors with single or double rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts including PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in filling inside frame & hold fasts etc complete all as specified and as directed by the Engineer-in-Charge. Note :- Distrubed protion of existing floor/ wall/ tile/ plaster etc during fixing of chowkhats shall be repaired to match with exisitng finish. Cost of the same will be included in this items.
S&F Flush shutters, 35 mm thick solid core construction, with block board core and plywood face panels, ommercial type on both sides and both face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed by Engineer-in-Charge.
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S&F factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bbottom rail; Panelling of wood grain printed PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 150mm Aluminium handles, cast type anodised complete all as specified and directed by Engineer-in-Charge.
S&F 125mm Aluminium handles, cast type anodised complete all as specified and directed by Engineer-in-Charge.
S&F butt hinges, extruded alluminium, with mild steel hinge pin, bright polished and fixed, type 100mm size C-22 complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium alloy, anodised, sliding door bolt 200mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge.
M&L for Anodised aluminium frame powder coated for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium ventilators, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium powder ocated window double shutters for galss and wiremesh, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 No.) complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement complete all as specified and directed by Engineer-in-Charge.
S&F 4.8mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares exceeding 0.50 Sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples complete all as specified and directed by Engineer-in-Charge.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 150 mm complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of New or previously untreated wood and wood based surfaces of any description, .exc 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia GI tubing (ISI marked) medium grade with all fittings and fixed complete to wall, ceilings and laid in floor, roof top etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 58.00 here-in-before above but 20mm dia bore
S&F wash down water closet (EWC) white, (excluding flushing cistrern and flush pipe) including connection to drain (or outgoing pipe), with plastic seat cover and making good to the floor complete all as specified and directed by Engineer-in-Charge.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm bore bib taps, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S&F 10 ltrs capacity PVC low level flushing cistern with inlet, ball valve, float, handle including fitting and fixtures and providing connections to WC and flush pipe without any damage to the existing fittings, complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous china wash basin, white, flat back size 550 X 400 mm excluding taps, chain and plug and porcelain stopper but including CP waste coupling & brackets and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 450 mm long PVC connection pipe of 15mm bore with PTMT nut at both ends complete all as specified and directed by Engineer-in-Charge.
S&F chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed by Engineer-in-Charge.
S&F CP Brass toilet paper holder with wall hook bracket etc, complete set of superior quality os any size complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe with fittings and accessories, ISI marked and as per IS 14846 complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia stop valves, cast copper alloy screwed presure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed but fancy type chromium plated with long shank and cup (concealed type) complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F tubular towel rail, brass chromium plated 20 mm dia `D' type 60 cm long between flanges complete all as specified and directed by Engineer-in-Charge.
S&F sand cast iron soil, waste and vent pipes 100mm dia in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F sand cast iron soil, waste and vent pipes 75 mm dia in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F sand cast iron soil, waste and vent pipes 100mm dia in any length with or without ears, with cement joints, fixed to wall complete all as specified and directed by Engineer-in-Charge.
S&F sand cast iron soil, waste and vent pipes 75 mm dia in any length with or without ears, with cement joints, fixed to wall complete all as specified and directed by Engineer-in-Charge.
S&F CI Bends 100 mm dia (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F CI Bends 75 mm dia (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F CI 100mm Bends (any radius) with duck's foot or heel rest complete all as specified and directed by Engineer-in-Charge.
S&F CI 100 mm dia P or S trap complete all as specified and directed by Engineer-in-Charge.
S& F Cast iron 75 mm vent cowl complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm nahani trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) etc complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
M&L for DWCPE (SN 8) 180 mm outer dia and 163mm inner dia pipe laid on 150 mm thick bed including with excavation in any type of soil, including manholes/drop manhole of standard size made of brick masonry/RCC/precast RCC with SFRC ventilating cover and frame. Including all items and activities to execute and make sewer line functional depth upto 1.65 mtr complete all as specified and directed by Engineer-in-Charge.
S&F 30mm dia fancy stainless steel curtain rod with fancy fixing brackets, fancy stops/supports, rollers etc complete all as specified and directed by Engineer-in-Charge.
M&L for 25 mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) over roof, terrace using integral WPC as per manufacturer's instructions well compacted and fair finishcomplete all as specified and directed by Engineer-in-Charge.
M&L for Applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning of surfaces complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks 1000 litres capacity triple layered (White ) cylindrical vertical with closed top hoisted and 20mm ball valves high pressure with polythene float and flynut complete fixed in position complete all as specified and directed by Engineer-in-Charge.
E&M WORK M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit of dia not less than 20mm and conduit accessories, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) concealed in wall/roof/floor etc with mild steel/pressed steel sunken boxes (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with modular cover and plate for fixing of modular switches, sockets etc including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge for the following :- Note:- Modular switch and socket shall be measured and paid separately.
All as per Item No.89.00 here in before above but for One light point controlled by one way switch complete all as specified and directed by Engineer-in-Charge.
All as per Item No.89.00 here in before above but for One Ceiling Fan/Exhaust fan point controlled by one way switch complete all as specified and directed by Engineer-in-Charge.
All as per Item No.89.00 here in before above but for one socket outlet 3/2pin 5 amps point on the same board with other switches complete all as specified and directed by Engineer-in-Charge.
All as per Item No.89.00 here in before above but for point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed (FRLSH) cable 1100 volts grade and 2.5 Sqmm PVC insulated and unsheathed (FRLSH) cable 1100 volts grade with multi-stranded copper conductor as earth wire for 5/6 Amps multipurpose socket combination point on independent board complete all as specified and directed by Engineer-in-Charge.
All as per Item No.89.00 here in before above but for point wiring with 4.0 sqmm single core multi stranded copper conductor PVC insulated and unsheathed (FRLSH) cable 1100 volts grade and 4.0 Sqmm PVC insulated and unsheathed (FRLSH) cable 1100 volts grade with multi-stranded copper conductor as earth wire for 15/16 Amps multipurpose socket combination point on independent board complete all as specified and directed by Engineer-in-Charge.
S&F switch Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engineer-in-charge.
S&F modular Socket, 6A - 2/3 pin combined 2 module, ISI Marked with valid CML No complete all as specified and directed by Engineer-in-charge.
S&F Modular Switch socket Combination 16A, 5 pin, 3 module ISI Marked with valid CML No complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body complete all as specified and directed by Engineer-in-charge.
S&F Modular Fan step regulator, 120W - 2 module ISI Marked with valid CML No complete all as specified and directed by Engineer-in-charge.
S&F lamp holder insulated polycarbonate body with back plate suitable for battern fittings complete all as specified and directed by engineer-in-charge.
S&F Vertical triple pole & neutral, 4 way 415 Vdouble door powder coated CRCA stel sheet constructed as per IS : 8623 degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 Amps tinned copper bus bar, neutral busbar, earth bar, din bar bar detachable gland plat, interconnection, earthing connection, blanking plates in unused spaces as required suitable for TP/FP MCCB as incomer including MCCB 63 Amp 16 KA 415 Volt complete all as specified and directed by Engineer-in-charge.
S&F for sheet metal enclosure MCB SPN DB 12 way made out of 1.5 mm thick sheet metal enclosure IP 43 with 200 Amps rated bus bar 240 volts double door with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed by Engineer-in-charge.
S&F MCB SPN 240 volts, 63 Amps, 10 KA repturing capacity C curve complete all as specified and directed by Engineer-in-charge.
S&F MCB SP 240 volts, 10 to 32 Amps, 10 KA, repturing capacity C curve complete all as specified and directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two runs of single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-charge. Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable continuity earth and one run of PVC conduit with all necessary accessories shall be paid as one unit length
S&F of LED bulb 10 Watt complete all as specified and directed by Engineer-in-charge.
S&F of LED tube light fitting 10 Watt tube LED neutral white in colour 600 mm in length wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation & integrated electronic driver optic diffused type including all electric connections with white flexible cord 1.5 sqmm 3 core as required10 W surface / wall mounted decorative type LED batten capable of deliverin complete all as specified and directed by Engineer-in-charge.
S&F surface and wall mounted LED tube light along with fixture 4 feet 20 Watt extruded aluminium housing provided for efficient heat disspation with polycarbonate, operating voltage 240 volts, 50 Hz, AC supply and operating temperature 0 to 50 degree C, power factor > 0.90, lumen output > 2000 and provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe complete all as specified and directed by Engineer-in-charge.
S&F LED street light of capacity 36 Watt with inbuilt driver having pressure die cast aluminium housing IP-66 having efficiancy of > 100 Lumens/Watt, operating voltahe - 120 to 270 Volts, P.F > 0.95, T.H.D < 10%, both fixture/ luminarie & driver must have separate bis marked registration and it must be mentioned clearly on fixture & as well as on drive also. Suitable for 30 to 50 mm O.D mounting pipe and suitable for mounting on wall/pole including connection with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge.
S&F 1.2 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 Amps complete all as specified and directed by Engineer-in-charge.
S&F ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor including necessary connecting cable as recommended by manufacturer complete all as specified and directed by Engineer-in-charge.
S&F exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-charge.
Cutting of wall with mason for making window suitable for fixing of 300mm exhaust fan and making good as per existing surface of wall complete all as specified and directed by Engineer-in-charge.
S&F water heater, storage type (geyser) vertical type inner container of capacity 25 litres power 2.0 KW, BEE 5 Star rated pressure rating >8 bar electrically operated, AC 230 volts including as per site required Nos of fashner nuts required suitable size fixed in brick/stone wall complete all as specified and directed by Engineer-in-charge.
S&F PVC connector pipe heavy duty of length 450mm,15 mm dia suitable for hot and cold water complete all as specified and directed by Engineer-in-charge.
M&L for bore earthing not less than 250mm dia 16 feet deep filled with black soil upto 7 feet from bottom complete with galvanised iron pipe 40mm bore medium grade 3m long tapers at bottom & provided 12mm holes (staggered) at 75mm centre to centre upto 2.5m of length from bottom, burried directly in ground filled with 45cm alternate layer of magnisium sulphate, charcol & salt up to ground level & connected to galvanised iron wire 4.0 mm dia above ground level as earthing lead by means of bolt and nut, check nuts and washers of galvanised iron or steel including brazing work upto equipment and 40mm dia light grade GI pipe for earth lead protection including test point terminal cover the earthing hole by PCC chamber and GI cover and testing on completion complete all as specified and directed by Engineer-in-charge.
S&F 20mm bore galvanized steel, medium grade, with all fittings, laid in trenches fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 50mm bore galvanized steel, medium grade, with all fittings, laid in trenches fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 50mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe with fittings and accessories, ISI marked and as per IS 14846 complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 (Type C2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for road cutting for the existing bituminous road /Hard Standing to size not exceeding 0.5m wide and depth 0.6m for crossing pipe including refilling, ramming and making top 100mm thick surface good wih PCC 1:3:6 type C-1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-charge.
Cutting the existing 80mm pipe CI/GI & inserting Tee size of 80x80x50mm complete all as specified and directed by Engineer-in-charge.
Construction of valve chamber of size 90 x 90 x 90 cm (internal dimensions) with the following specifications and complete all as specified and directed by Engineer-in-Charge :- (i) 15cm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation concrete. (ii) PCC solid block masonry 200mm thick using grade C-5 block built in CM 1:6 (iii) Rendering 15mm thick in CM 1:4 finished even and fair. (iv) PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in coping. (v) 3mm thick MS sheet cover alongwith MS angle iron frame 40 x 40x6 mm duly embedded in coping concrete with necessary locking arrangement. (vi) Painting MS sheet cover and frame with two coats of synthetic enamel paint over a coat of red oxide primer. NOTE : Excavation and earthwork shall deemed to inclusive in the rate quoted by the contractor.
Supplying, laying, testing and commissioning of LT UG, XLPE insulated, heavy duty, 1100V grade of size 50 Sqmm 3.5 core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete all as specified and directed by Engineer-in-charge. Note : - Earthwork excavation sand cushioning, bricks protection, GI protection pipe shall be measured and paid separately in their respective items
M&L for sand cushioning to underground cable with sand and punning to provide required cover complete all as specified and directed by Engineer-in-charge. Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment.
Supply & laying 40 to 50 mm thick roughly hammer dressed Jodhpur stone patti cable cover 25 cm to 30 cm wide and n.exc 60 cm long each laid dry abutting with each other with maximum gap between adjacent slabs n.exc 10 mm complete all as specified and directed by Engineer-in-charge.
Supply and laying 50mm dia pipe galvanized iron steel tubing, light grade, with all fittings for protection of cables laid in trenches/ road / floor etc complete all as specified and directed by Engineer-in-charge.
M&L for road cutting for passing of HT/LT cable inside of GI pipe of suitable size (minimum 50 mm dia) light grade complete digging after laying of pipe line / cable making and good the disturb surface complete all as specifid and directed.
M&L for bore earthing not less than 250mm dia 16 feet deep filled with black soil upto 7 feet from bottom complete with galvanised iron pipe 40mm bore medium grade 3m long tapers at bottom & provided 12mm holes (staggered) at 75mm centre to centre upto 2.5m of length from bottom, burried directly in ground filled with 45cm alternate layer of magnisium sulphate, charcol & salt up to ground level & connected to galvanised iron strip 32 X 6 mm dia above ground level as earthing lead by means of bolt and nut, check nuts and washers of galvanised iron or steel including brazing work upto equipment and 40mm dia light grade GI pipe for earth lead protection and testing on completion and including taking out old earthing complete all as specified & directed.
AMBEY MAA CONSTRUCTION COMPANY (BID ID -3342033)
M/s Shri Inder Construction Company (BID ID -3331637)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .