Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAccepted-AOC 371 21 RBL ROAD NEW HYEDERABAD COLONY LUCKNOW UTTAR PRADESH 226007 | LUCKNOW | UTTAR PRADESH | 226007 | L1 | Accepted-AOC Documents OK |
Tender Value
₹3.1 L
EMD Value
₹6,197
Closing Date
16 Jun 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E)
O/o Executive Engineer (Electrical) BSNL Electrical Division 1ST Floor, Bhopal House, Lalbagh Lucknow
Operation and Comprehensive Maintenance of electromechanical services at T.E. Mahanagar, Lucknow SH Rectification of handing over defects on the risk and cost of M/s Madhu Refrigeration Lucknow
2022_BSNL_118222_1
12/TEDL/BSNL/LKO/2021-22,Dated 02/09/2021
Open Tender
Electrical Works
Item Rate
30 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO (Cash) BSNL O/o The PGMTD, LUCKNOW
₹6,197
4 Jul 2022
6 Jun 2022
17 Jun 2022
6 Jun 2022
16 Jun 2022
6 Jun 2022
90 days
SH:I Sub Station:- Supplying & topping of transformer oil in 3 Nos.HT breakers having break down strength of 40 KV for a minute at a distance of 4 MM. (Make Savilta / Power oil)
Replacement of following faulty CT Operated 11 KV Amp. Meter of rating 0-60 Amp., round shape in the existing 11 KV HT OCB i/c connection, testing etc. complete as required.
Repairing of existing power pack unit (battery charger) for for HT Tripping & charger circuit i/c indication lamps, relays, doides etc. complete as required.
Supplying & fixing set of 4 nos. 12V 7AH maintenace free battery in existing battery charger box complete as required. (Exide make)
Replacement of silica gel breather(1Kg) with complete set i/c fixing etc complete as required.
Replacement of following faulty accessories in the existing Emergency panel/Main panel i/c connection, testing etc. complete as required (a) LED type indicating lamps
Replacement of following faulty accessories in the existing Emergency panel/Main panel i/c connection, testing etc. complete as required. (b) TPN SFU 63 Ampi/c ISI marked HRC fuses(Make L&T, FN type or SS make)
Replacement of following faulty accessories in the existing Emergency panel/Main panel i/c connection, testing etc. complete as required © 250 Amp. HRC fuse(Make L&T or SS make)
Replacement of following faulty accessories in the existing Emergency panel/Main panel i/c connection, testing etc. complete as required. (d) 200 AmpTPN SFU i/c ISI marked HRC fuses(Make L&T, FN type or SS make)
Replacement of following faulty accessories in the existing capacitor panel i/c connection, testing etc. complete as required. (a) 96mmx96mm size CT operated amp meter of rating (0-800/600/400) Amp.
Replacement of following faulty accessories in the existing capacitor panel i/c connection, testing etc. complete as required. (b) 96mmx96mm size Volt meter of rating (0-500) Volt
Replacement of following faulty accessories in the existing capacitor panel i/c connection, testing etc. complete as required. © CT 400/5
Replacement of following faulty accessories in the existing capacitor panel i/c connection, testing etc. complete as required. (d) LED type indicating lamps
Replacement of faulty 11 KV Volt Meter of rating 0-15 Volt, round shape in the existing 11 KV HT OCB i/c connection, testing etc. complete as required
Replacement of faulty,3phase,415 Volt,8 stage,LED display APFC relay with advanced microprocessor based power factor controller,Auto, manual,Lead,Lag and capacitors status indications and suitable for balanced/ unbalanced load etc in the existing capacitor panel i/c connection, testing etc. complete as required(Make- L&T or approved make)
SH:II EI:- Replacement of following accessories in the existing fitting/switch board, connections, testing etc.complete as required. (a) 36 Watt florescent tube rod
Replacement of following accessories in the existing fitting/switch board, connections, testing etc.complete as required. (b) 11 Watt CFL
Replacement of following accessories in the existing fitting/switch board, connections, testing etc.complete as required. © 5/6 Amp. Piano type,3 pin socket
Replacement of following accessories in the existing fitting/switch board, connections, testing etc.complete as required. (d) 5/6 Amp. Piano type switch
Replacement of following accessories in the existing fitting/switch board, connections, testing etc.complete as required. (e) 15/16 Amp. Piano type, 6 pin socket
Replacement of following accessories in the existing fitting/switch board, connections, testing etc.complete as required (f) 15/16 Amp. Piano type switch
Replacement of following accessories in the existing fitting/switch board, connections, testing etc.complete as required. (g) 40 W electronic choke
Replacement of faulty 125 Amp TP MCCB,16K breaking capacity with thermomagnetic release and terminal spreaders in Vertcal DB at ground floor power plant room i/c dismantalling of faulty MCCB,connection etc complete as reqd.(Make- Havell's,L&T,HPL or ss make)
SH:III PAC units :- Replacement of faulty 3.5 TR compresser of Kopeland make model CR 57) in conventional type Sidwal make, 7 TR package AC unit no.1 i/c dismantling of faulty compressor cutting ,welding brazing,transportation etc complete as reqd.
Leak testing of copper refrigerant piping (suction & discharge line)of package AC No. 1 with the help of nitrogen gas, holding the pressure for 24 hours i/c brazing,vacuming etc complete as reqd.
charging of refrigerant R-22 gas in Package AC No. 01 i/c transportation, labour charges, testing commissioning etc complete as reqd.
Replacement of burnt single phase Condensor Fan Motor in Pkg AC No.1 i/c dismantalling, refixing testing commissioning etc as reqd
Replacement of single phase Condensor Motor fan blade in Pkg AC No.1 i/c fixing testing commissioning etc as reqd.
Repairing & rewinding of burnt single phase fresh air Fan Motor in AC pant room i/c dismantalling, refixing testing commissioning etc as reqd
Replacement of following faulty accessories in the existing AC Plant Panel i/c connection, testing etc. complete as required. (a) TPN SFU 63 Amp.(Make L&T, FN type or SS make)
Replacement of following faulty accessories in the existing AC Plant Panel i/c connection, testing etc. complete as required. (b) Backelite kit-kat fuse with 63 Amp HRC fuses(Make L&T or SS make)
SH-IV : AFD System & Fire Extinguishers:- SITC of Optical smoke detector with base,blinking LED type as per attached specification.(Agni or BSNL approved make)
SITC of electronic hooter cum speaker with range of 25 to 30 Mtrs. with 4Watt speaker as per specification.(Agni or BSNL approved make)
Replacement of Mic for automatic fire alarm system i/c lead etc complete as reqd.
Re-filling of 4.5 Kg CO2 type fire extiguishers etc. complete as required. (Note: The refilling shall be done only at the authorized refilling centers)
SITC of CO2 type (4.5kg) wall mounting type fire extinguisher with hose of suitable length including first charge / refilling & providing hook, hose clamps and with ISI mark on the extinguisher etc. as required. (Note: The Extinguisher will be Manufactured Strictly as per BIS: 13849:1993 bearing ISI. mark.
SITC of Dry powder type (2.0kg) wall mounting type fire extinguisher with hose of suitable length including first charge / refilling & providing hook, hose clamps and with ISI mark on the extinguisher etc. as required. (Note: The Extinguisher will be Manufactured Strictly as per BIS: 13849:1993 bearing ISI. mark.
Re-filling of Dry powder type fire extiguishers etc. complete as required. (Note: The refilling shall be done only at the authorized refilling centers)
SH-V: SAC/WAC :- Replacement of broken blower drum of 1.5 TR split AC unit i/c fixing, testing etc as required.
Replacement of rotary compresser of 1.5 TR i/c cutting ,welding brazing, vacumising and leak testing etc as reqd. ( M/S Emerson Kopeland or ss make)
Replacement of out door fan motor of SAC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd.
S/charging of refrigerant gas for in the refrigerant circuit of existing SAC unit, vacumising and leak testing etc as reqd
Replacement of fan blade of condencer motor of Split AC i/c fixing etc complete as reqd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .