| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.0 LAccepted-AOC U 57 OPP AGGARWAL NURSING HOME RAJU GAS AGENCY OFFICE VIJAY NAGAR NARELA DELHI DELHI 110040 | NORTH | DELHI | 110040 | 1 | Accepted-AOC 1 | |
| 2 | 2₹4.2 L+₹22,605 (5.66%)Rejected-Finance 0 KALAMBAGH CHOWK MUZAFFARPUR BIHAR 842002 UDYAM BR 23 0013096 | MUZAFFARPUR | BIHAR | 842002 | 2 | Rejected-Finance 2 | |
| 3 | 3₹4.3 L+₹26,780 (6.70%)Rejected-Finance R 40 VIKAS MARG SAKAR PUR DELHI 92 | 3 | Rejected-Finance 3 | |
| 4 | 4₹4.6 L+₹63,532 (15.9%)Rejected-Finance | 4 | Rejected-Finance 4 |
Tender Value
₹4.7 L
EMD Value
₹9,489
Closing Date
2 Nov 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE-III/RZ
EEE-III/RZ
Improvement of lighting arrangement in various Mpl parks and locations of ward no-45 under Rohini zone
2023_MCD_172394_1
EEE-III/RZ/TC/2023-24/11.3
Open Tender
Electrical Works
Item Rate
120 days
EEE-III/RZ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹9,489
16 May 2025
28 Oct 2023
3 Nov 2023
28 Oct 2023
2 Nov 2023
28 Oct 2023
Amount
OD11027/2023-2024:(1.17.11) S/D of following size of FRLS PVC insulated copper conductor ,Single core cable in the existing surface /recessed steel/PVC conduit as required . 2 x2.5 sq.mm
OD11028/2023-2024:(5.18) P/F of 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.
OD11029/2023-2024:(14.16.1) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
OD11031/2023-2024:(5.15) Providing and fixing 25mm x 5mm GI strip on surface or in recess for connections etc as reqd
OD11032/2023-2024:(5.1) Earthing with GI Earth pipe 4.5 m long, 40mm dia i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc (but without charcoal or coke and salt) complete as required.
OD11033/2023-2024:(2.12.2 )Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
OD11034/2023-2024:(2.10.1) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, & 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD11035/2023-2024:(7.5.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
OD11036/2023-2024:(7.6.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
122.1.42:Supply of 14/15 Watt LED retrofit lamp suitable for B22 holder
122.2.3:Supply and fixing of Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole window door suitable for 12M semi high mast pole etc as reqd.
122.2.28:SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.33:SITC of 60W LED Street Light luminaire fitted with lens, top opening driver cover made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.174:Supply and fixing of 50 watt IP65 decorative single piece LED fixtures with die cast aluminium housing frosted PMMA / PC diffuser, suitable for upward mounting with power LEDs white/warm white fitted with suitable extruded aluminium heat sinks, high voltage protection and suitable constant current LED driver extra as required. Technical Particulars i) Size of fiiting- 580mm x 340mm, base section inner dia- 64mm and outer dia- 71mm ii) Total power of light fixture- 50 Watt iii) Input voltage-AC 120 to 270volt 50Hz iv) Power factor >0.95 v) Minimum lumen output of LEDs - 100 Lumen per watt vi) Luminaire protection - IP65
122.2.17:Fabrication, supplying and fixing class B galvanised double overhang arm bracket made out of 250mm long galvanised top tube with cap and 250mm long 32 mm dia galvanised pipes with tightening bolts complete as required.
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.190:Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class) bracket for mounting of fluorescent/HPMV/HPSV Street Light fitting on pole including bending the pipe to the required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd.
OD13306/2023-2024:Shifting of one number of 12 Mtr Semi high mast light system with its acessories and reinstallation ,testing ,Commissioning the same on suitable RCC (1:2:4) shallow foundation of size 1M (L) X 1 M (wide) and 2 Mtr deep i/c excavation of earth ,providing cutting and bending , placing in position ,reinforcement of cold twisted bar of 12 mm dia -2100 mm long (aprox) -13 Nos (with 150mm spacing ) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit with foundation nut bolts and anchor plate as required for high mast Considering the safe soil bearing capacity at site as 10T/sqm at 2 Mtr depth
Naman Enterprises
VISHU ELECTRICALS
Kamal Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .