Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC PEMASAR ROAD WARD NO 04 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L1 | Accepted-AOC Due to lowest bidder | |
| 2 | L2₹41.3 L+₹2.8 L (7.15%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Due to not lowest bidder | |
| 3 | L3₹43.6 L+₹5.0 L (13.1%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L3 | Rejected-Finance Due to not lowest bidder | |
| 4 | L4₹49.6 L+₹11.0 L (28.5%)Rejected-Finance 29 GANDHI NAGAR VETERINARY COLLEGE ROAD BIKANER 334001 RAJ | BIKANER | RAJASTHAN | 334001 | L4 | Rejected-Finance Due to not lowest bidder |
Tender Value
₹45.2 L
EMD Value
₹90,320
Closing Date
8 Sept 2023, 6:00 pmClosed
GE (N) BIKANER
GE (N) BIKANER RAJASTHAN-334001
SPL REPAIR TO BER GEYSER, CEILING FAN AND COOLING APPLIANCES AND PROVN OF 01 X SERVO VOLTAGE STABLISER 100 KVA , 2 HP MOTOR PUMP , 3 PHASE ELECTRICAL SUPPLY TO VEHICLE AND 01 X COOLING DEVICE FOR SERVER ROOM UNDER GE N BIKANER
2023_MES_609367_2
GE (N) BKN-TOKEN/43/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (N) BIKANER
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (N) BIKANER
₹90,320
Yes
16 Jan 2024
18 Aug 2023
15 Sept 2023
18 Aug 2023
8 Sept 2023
26 Aug 2023
Amount
S & F water heater storage type 25 Ltr capacity, BEE 5 star and 8 bar pressure rated stainless steel (minimum wall thickness 2 mm) tank with feroglass coated inner container energy saving high density PUF insulation vertical ABS shock proof plastic body grouting of studs in wall in cement motar (1:3) nuts, washers, provision of two Nos PVC braided connection 450mm long heavy duty with brass nuts and two Nos brass chromium plated angular valve,thermostate,NRV ,TOP PLUG 20AMP with valve flange suitable for 15mm bore pipe for water supply connection complete all as specified & directed by Engr-in-charge.
S & F water heater storage type 50 Ltr capacity, BEE 5 star and 8 bar pressure rated stainless steel (minimum wall thickness 2 mm) tank with feroglass coated inner container energy saving high density PUF insulation vertical ABS shock proof plastic body grouting of studs in wall in cement motar (1:3) nuts, washers, provision of two Nos PVC braided connection 450mm long heavy duty with brass nuts and two Nos brass chromium plated angular valve,thermostate,NRV ,TOP PLUG 20AMP with valve flange suitable for 15mm bore pipe for water supply connection complete all as specified & directed by Engr-in-charge.
Supply, only of 1200 mm sweep BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor , Class of insulation : B, 3 nos blades, 60 cm long down rod 1 Nos, Canopies 02 Nos shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air Delivery minimum 220 CMM, 370 RPM ( tolerance as per IS : 374-2019 ), THD less than 10% remote unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.) insulation resistance more than 2 mega ohm, suitable for 230 V , 50 Hz , single phase AC supply, 35W, earthing complete all as specified & directed by Engr-in-charge. Notes :- (i) Flexible copper conductor cable 3 core for making connection of fan from connector to ceiling rose shall be measured & paid for separately under respective item as “Supply only” (ii) The font style & place of wiring SM/MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer – in-charge and cost thereof shall deemed to be included in quoted rates.
Supply olny refrigarator double door electrial driven (single Phase) capacity 308 ltrs BEE 5star rated , compressor inverter type automatic silver colour , the following specification , Capacity : 308 , Rated : 3 Star , Colour : Silver , Type of Compressor : Invertor Type , Functional : Automatic , Finish : Touch Glass complete all as specified & directed by Engr-in-charge. Brand : LG Model GL-D322JNSZ and Equivalent
Deep freezer single door minimum 310 Ltr capacity with touchened and or hard top glass single phase 230 volt complete all as specified & directed by Engr-in-charge. Brand LG / Samsung / Voltas
Supply ,Installation,commissioning of Water Cooler fully stainless steel ,Electric driven single phase having approx storage and nominal cooling capacity of 60/80 Ltrs complete all as specified & directed by Engr-in-charge.
Supply ,Installation,commissioning of Water Cooler fully stainless steel ,Electric driven single phase having approx storage and nominal cooling capacity of 80/120 Ltrs complete all as specified & directed by Engr-in-charge.
Supply and installation of servo controlled Voltage stabilizer for automatic operation, three phase naturally oil cooled outdoor type & designed for input variation between 340 V to 480 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 50 Volts per second and of capacity 100 KVA, Technical specification of voltage stabliser is listed below :- (a) Input voltage range in 3 phase - 340 V to 480V (b) regulated voltage output range in 3 phase - 400 V + 2% (c) Input frequency - 47 to 52 Hz (d) Motor type - AC servo motor, high torque, low inertia, instant start stop revesible, brush less, Gearless, construction using ball bearing for long maintenance free life. (e) breakdown strength for overload - at 200 % load for 5 sec (f) Type of insulation - type B (g) control circuit - Micro controller based digital circuit and control (h) Metering - seven segment display (j) Ambient temperature - 0-55 degree C (k) Optional protection - Input MCCB
Supply & Laying, testing & commissioning of LT UG cable XLPE sheathed PVC insulated,screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in trenches, in GI pipe , including brass cable glands, clamps etc of size 3.5 Core x 120 sq mm complete all as specified.Make :- Polycab/Havells/KEI
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 meter and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with flat , size 250mm x 150mm x 40mm.complete all as specified & directed by Engr-in-charge.
Supply & Laying & commissining of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in tranches, in GI pipe, including brass cable glands, clamps etc of size 4 core x 25 Sqmm complete all as specifed and as directed. Note: Earthwork, sand cushioning, bricks, GI pipe, etc will be measured and pad under appropriate items.
Supply and laying bricks (old size) for cable protection by using common burnt clay building bricks, sub-class ‘B’ designation 75 laid dry flat across length of the cable with width of the trenches equal to length of bricks and all as directed.
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for.
Supply and fixing GI Pipe light grade og Size 80 mm bore with all fittings for passing of cables fixed to pole/wall/laid under floor or roads including all fixing accessories complete for protection of cable all as specified and directed. Make: Jindal/ Bansl/Tata
S&F sheet metal enclosure MCB DB, double door, vertical TPN 4 way with 200 Amps rated busbar all as specified and as directed.
S&F MCCB 100 amps, 4 pole, 415 volts, fixed type breaking capacity 16KA complete all as specified and as directed by Engr-in-charge.
S & F MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
Supply, installation, fixing and commissioning of split type air conditioner of capacity 1.5 TR, BEE & minimum 3 star rated ,with cordless remote control unit suitable for wall mounted single phase 230/250 volt AC including breaking necessary for fixing indoor and outdoor unit and making good to distrubed surfaces with cement morter to match with existing colour after commissioning, making connection between indoor and outdoor unit with copper tubing with proper insulation and making necessary connection unplasticised PVC pipe medium duty 20 mm dia for draining out condensed water all as required including necessary connection complete. Note:- (i) Rate to be included cost of bracket, drain pipe, hole in brick wall etc.(ii) Cost of copper tubing for indoor and out door unit deemed shall be including quated rate as per O.M.
Supply and installed Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type& designed for input variation between 170 V to 250 V with out put voltage stabilized at 230 Vwith accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and as directed by Engineer-in-Charge.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed by engineer-in-charge.
Sheet metal enclosure for distribution boards double door, suitable for fixing MCBs 240 volts with 200 Amps rated bus bar, SPN, 2 ways, supplied and fixed in repair, including making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge.
MCB suitable for 6 to 32 Amps, 240 Volt AC supply single pole and neutral with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.
M&L sub main wiring with 2 single core, multi-stranded PVC insulated cable unsheathed 1100 volts grade with copper conductor of size 4 sq mm drawn and including PVC casing capping including earth continuity conductor cable of size 4 sq mm PVC insulated unsheathed copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge.
Supply & laying in trenches GI pipe of size 25 mm bore ISI marked medium grade complete with fittings all as specified & directed by the Engineer-in-Charge.
Supply & fixing gun metal gate valve screwed both ends with iron wheel head ISI marked for 25 mm bore pipe line complete all as specified & directed by Engr-in-charge.
Suppy and installatios of single phase starter suitable 2 HP single phase motor complete all as specified & directed by Engr-in-charge.
Supply and installation of 02 HP monoblock pump set ,230 volts AC , 50 HZ complete all as specified & directed by Engr-in-charge.
Supply and laying in replacement of Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminium conductor, 1100 volts LT grade of cross-sectional area 10 Sqmm 02 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments complete all as specified & directed by Engr-in-charge.
Supply and installation of PVC tank of capacity 5000 Ltrs, including preparation of base and necessary PCC work, complete all as directed by engr-in-charge Note: (a) Size of foundation shall not be less than 4mtrx4mtrx1mtr(LxBxH) (b) Cost of necessary excavation, brick work & PCC for foundation shall be included in the quoted rate.
M/S BUDHRAM BISHNOI
M/s Rohit Construction Co.
MITTAL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .