| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹11.4 L+₹1.5 L (14.6%)Rejected-Finance NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L2 | Rejected-Finance Other than Lowest Bid | |
| 3 | L3₹11.6 L+₹1.7 L (17.4%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bid | |
| 4 | L4₹12.0 L+₹2.1 L (21.3%)Rejected-Finance 158 PADRI BAZAR TINKONIYA NO 1 PARVATIPURAM GORAKHPUR GORAKHPUR UTTAR PRADESH 273014 | GORAKHPUR | UTTAR PRADESH | 273014 | L4 | Rejected-Finance Other than Lowest Bid | |
| 5 | L5₹12.7 L+₹2.8 L (28.3%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L5 | Rejected-Finance Other than Lowest Bid |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
13 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jalandhar Cantt
HQ CWE kabir Road Jalandhar Cantt Pin-144005
Please refer tender documents
2020_MES_351748_1
CA NO CWE/JAL/E-20/2020-21 8320/20/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jalandhar Cantt
Class E Category a(i) or b(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
Garrison Engineer East JRC
₹42,000
Yes
31 Aug 2020
11 Jun 2020
15 Aug 2020
11 Jun 2020
13 Aug 2020
31 Jul 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr deep and not exceeding1.5 mtr in depth for laying of cables and getting out in soft/loose soil etc complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus spoil to a distance n.exc 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Note: Excavation and earth work shall be measured and paid for separately). Note : Punned down thickness shall be measured.
Supply and laying old size sub class ‘B’ bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed.
M & L for boring of hole under the road/pavement /hardstanding to insert GI Pipe of suitable dia not more than one metre below ground level complete all as specified.
Material and labour for Cement concrete 1:4:8 type D-2, using 40mm graded stone aggregate as in foundation of electric pole,platform etc including necessary form work and fair finish to exposed surface complete all as specified and directed.
Material and labour for Cement concrete 1:3:6 type C-2, using 40mm graded stone aggregate as in foundation of stay/coping etc including necessary form work and fair finish to exposed surface complete all as specified and directed.
Supply, laying, Jointing and testing XLPE insulated screened,PVC bedded,galvanised steel strip or wire armoured ,electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 10 sqmm 2 core and laid in trenches/pipe/ducts or on pole complete all as specified and directed.
All as per Srl item No 9 above but of size 25 sqmm 4 core complete all as specified.
All as per Srl item No 9 above but of size 70 sqmm 3.5 core complete all as specified.
All as per Srl item No 9 above but of size 95 sqmm 3.5 core complete all as specified.
All as per Srl item No 9 above but of size 185 sqmm 3.5 core complete all as specified.
S & F in replacement for Pre-stressed concrete pole LT 9 Mtr long 102mmx172mm at top and 102mmx179mm at bottom class 10 complying with the requirement of IS-1678-1978 erected in vertical position embedded in PCC foundation including painting with synthetic enameled paint in alternate white and black strips each 30cm wide up to 1.5 Mtr height from top of coping complete all as specified and directed Note :- Earth work, PCC for foundation and coping shall be measured and paid for separately.
Taking down LED street light luminaire 45 watt from old steel tubular/PCC pole and refixing on new pole complete all as specified and as directed
M & L for cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections Including Nuts,Bolts,Washers,Welding Bending Cold Or Hot, drilling holes for bolts , in any shape or size as indicated or and including painting with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed
Supply and fixing bracket made out of 32mm dia GI medium grade tubing 2 metre long and bent to shape at 120 degree angle at the middle from vertical fixed with clamps nuts and bolts washer complete all as specified. Note : Clamps, Nuts,Bolts and washers will be measured and paid separately.
M & L for 20mm dia PVC rigid conduit pipe exclusive of boxes(Junction/terminal) but inclusive of all tees, bends, elbows,reducers,bell mouth tube ends and fixing all accessories such as couplers,lock nuts,saddles pipe hooks etc complete all as specified and as directed by Engr-in-Charge.
Supply and fixing factory made junction box of size 250x 300x125mm suitable for street light fixed on pole,made out of CRCA sheet 2mm thick having front hinged shutter with lockable arrangements,outdoor type weather proof duly painted with two coats of synthetic enamel paint over a coat of red oxide primer having the provision to connect incoming and outgoing cable of size 25 sqmm 4 core with one No MCB SP, 10 KA,C-curve ,6 Amps,240 Volts and earthing plug complete all as specified and as directed by Engr-in- Charge. Note :- 1 MS clamps nuts,bolts required to fixing on pole shall be measured and paid for separately. 2.MCB shall be measured and paid for separately.
Supplying and fixing 1100 volts grade haevy duty single core cable PVC insualted PVC sheathed with stranded copper conductor wire FRLS,ISI marked drawing through 20mm dia PVC pipe/conduit of size 2x2.5 sqmm and 1x1.5 sqmm for connection purpose complete all as specified and as directed by Engr-in-Charge.
Supply and fix GI pipe 50mm bore light grade for protection of cable including provision of GI bends complete for fixing along GI pipe along wall/pole/laid under road/floor complete all as specified and as directed by Engr-in-charge.
Supply and fix GI pipe 40mm bore light grade for protection of cable including provision of GI bends complete for fixing along GI pipe along wall/pole/laid under road/floor complete all as specified and as directed by Engr-in-charge.
Taking down cross arms, channels, angle iron, clamps, nut, bolts, stay wire, stay assembly, GI wire, etc complete all as specified and directed
Taking down old LT cable of size 120 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
Taking down old LT cable of size 10 sqmm 2 core complete all as specified and as directed by Engr-in-charge.
Taking down old LT cable of size 25/35 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
Dismantling insualtors of any type any size from existing LT poles/street light feeders complete all as specified.
Dismantling old LT PCC/Steel tubular poles including street light brackets,channels,clamps etc complete all as specified.
Dismantling and taking down existing ACSR conductor of any size from electric pole HT/LT complete all as specified and directed.
Supply,install,testing and commissioning of Feeder pillar, outdoor cubical type weather and vermin proof totally enclosed made out of 3.15mm thick CRCA sheet machine pressed of suitable size,suitable to operate on 3 phase 4 wire system,415 volts 50 HZ double door with front and rear openable with locking arrangement incl frame of panel with angle iron of size 50 x 50 x 6mm , inner shutters for mounting switchgears etc, independent bottom gland plate for each incoming & outgoing cable of suitable size as per switchgear rating, having apron on 3 sides of panel from base toi ground level presired including cable alley complete duly powder coated with 7 tank process comprising with following complete all as specified:- (i) Bus bar strip, four pole and capacity 400 Amp copper strip size 25 x 6mm based on 1.5 Amps per sqmm, coloured with plastic coated insulated and sleaves in four colours (Red,Yellow,Blue and black) fixed on porcelain insulators with necessary nuts and bolts and washers etc (ii) INCOMING:- (a) MCCB 250 Amp, 415 V, 25 KA, ICS=ICU=100% 4 pole wih fixed thermal magnetic release-01 No (b) Panel meters with LCD display-01 No (c) Indicator with neon lamps for RYB, 3 Phase with MCBs set of threee-01 Set (III) OUTGOING"- (a) MCCB 125 amp, 415 V, 25KA, ICS=ICU=100% 4 pole wih fixed thermal magnetic release-02 Nos (b) MCCB 40 Amp, 415 V, 16 KA, 4 pole wih fixed thermal magnetic release-04 Nos (c) MCB 4P 32 Amp, 415V, 10 KA,C-Curve-01 No (d) MCB DP 16 Amp, 415V, 10 KA,C-Curve-02 Nos (e) MCB DP 10 Amp, 415V, 10 KA,C-Curve-02 Nos (f) Indicator with neon lamps for RYB, 3 Phase with MCBs set of three- 07 Sets
Supply,install,testing and commissioning of Feeder pillar, outdoor cubical type weather and vermin proof totally enclosed made out of 3.15mm thick CRCA sheet machine pressed of suitable size,suitable to operate on 3 phase 4 wire system,415 volts 50 HZ double door with front and rear openable with locking arrangement incl frame of panel with angle iron of size 50 x 50 x 6mm , inner shutters for mounting switchgears etc, independent bottom gland plate for each incoming & outgoing cable of suitable size as per switchgear rating, having apron on 3 sides of panel from base toi ground level presired including cable alley complete duly powder coated with 7 tank process comprising with following complete all as specified:- (i) Bus bar strip, four pole and capacity 200 Amp copper strip size 20 x 4mm based on 1.5 Amps per sqmm, coloured with plastic coated insulated and sleaves in four colours (Red,Yellow,Blue and black) fixed on porcelain insulators with necessary nuts and bolts and washers etc (ii) INCOMING:- (a) MCCB 125 Amp, 415 V, 25 KA, ICS=ICU=100% 4 pole wih fixed thermal magnetic release-01 No (b) Panel meters with LCD display-01 No (c) Indicator with neon lamps for RYB, 3 Phase with MCBs set of threee-01 Set (III) OUTGOING"- (a) MCCB 40 Amp, 415 V, 16 KA, 4 pole wih fixed thermal magnetic release-04 Nos (b) MCB 4P 32 Amp, 415V, 10 KA,C-Curve-01 No (c) MCB DP 16 Amp, 415V, 10 KA,C-Curve-02 Nos (d) MCB DP 10 Amp, 415V, 10 KA,C-Curve-02 Nos (e Indicator with neon lamps for RYB, 3 Phase with MCBs set of three- 06 Sets
Supply , install, testing of bus bar chamber, outdoor cubicle type weather and vermin proof totally enclosed made out of 2mm thick CRCA sheet machine pressed of suitable size, suitable to fix on wall and suitable to operate on 3 Phase 4 wire system, 415 Volts, 50 Hz single door with front openable with locking arragnement, inner shutters for mounting switchgears etc, independent bottom gland plate for each incoming & outgoing cable of suitable size as per switchgear rating, prewired complete duly powder coated with 7 tank process comprising with following complete all as specified:- (i) Bus bar strip, four pole and capacity 100 Amp copper strip size 30 x 5mm based on 1.5 Amps per sqmm, coloured with plastic coated insulated and sleaves in four colours (Red,Yellow,Blue and black) fixed on porcelain insulators with necessary nuts and bolts and washers etc (ii) INCOMING:- (a) MCCB 40 Amp, 415 V, 16 KA 4 pole wih fixed thermal magnetic release-01 No (b) Indicator with neon lamps for RYB, 3 Phase with MCBs set of threee-01 Set Note Note:-Srl No 31 to 33: (i) For MCCBs in all LT panels ultimate breaking capacity should be equal to service breaking capacity. (ii) Drawing of LT Panels shall be got approved from GE before placement of order.
GULSHAN SINGH GHAI AND SON
Shree Balaji Construction
CHOUDHARY AND SONS
UNITED ENGINEERING CORPORATION
R D Bansal
SATISH AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .