| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹3.1 Cr | L1 | Accepted-AOC being lowest and reasonable |
| 2 | L2₹3.9 Cr+₹84.5 L (27.6%)Rejected-Finance | ₹3.9 Cr+₹84.5 L (27.6%) | L2 | Rejected-Finance being not lowest |
| 3 | L3₹4.3 Cr+₹1.2 Cr (39.7%)Rejected-Finance | ₹4.3 Cr+₹1.2 Cr (39.7%) | L3 | Rejected-Finance being not lowest |
| 4 | L4₹4.3 Cr+₹1.2 Cr (40.1%)Rejected-Finance | ₹4.3 Cr+₹1.2 Cr (40.1%) | L4 | Rejected-Finance being not lowest |
| 5 | L5₹4.5 Cr+₹1.4 Cr (46.3%)Rejected-Finance FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹4.5 Cr+₹1.4 Cr (46.3%) | L5 | Rejected-Finance being not lowest |
| Sl No | Description | Qty | Unit | M/S BHATIA BUILDERS AND CONTRACTORS L6 | Onkar Nath Bhalla And Sons Contractor Pvt. Ltd. L2 | M/S KIRAN CONSTRUCTIONS L7 | vijay builders L1 | M/S SINGH AND ASSOCIATES L5 | Standard engineers L4 | RSP Contractors India Private Limited L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Design of Power Driven sliding door including door pocket frame with claddings, other cladding top rail steel structure frame for support of steel trussed girder and steel column and its foundation in RCC, bottom rail and its foundation in RCC, captive drive unit, drive control panel equiped with and electrically operated brake, complete for 04 locations of entry and exit all as per design criteria, specification and as shown including undertaking soil investigation. Deliverable include (i) Detailed ARchitecture Dwg as per proposal of Scheme (i) Detailed structural GA Drawing (iii) Electrical GA and Schematic Dwd for Drivers (iv) Abstract of quantities and cost estimate, Yard stick. Tender purpose soil bearing capacity of nearby site enclosed.
Building Dimensions Double entry Blast Pens as per Tabled below Location Minimum Clear Minimum Clear Maximum number Minimum Maximum number
opening Width opening Height of Leaves allowed Track Length of Tracks allowed
BP#15 Front 18.30M 07.00M 03 Three 24M 03
BP#15 Rear 18.30M 07.00M 03 Three 24M 03
BP#18 Front 18.30M 07.00M 03 Three 24M 03
BP#18 Rear 18.30M 07.00M 03 Three 24M 03 | 1 | Each Job | 2,50,000 ₹2,50,000 | 5,00,000 ₹5,00,000 | 7,50,000 ₹7,50,000 | 1,50,000 ₹1,50,000 Lowest | 8,50,000 ₹8,50,000 | 15,00,000 ₹15,00,000 | 5,00,000 ₹5,00,000 |
| 2.00 | Fabrication, Erection and testing of factory made pre-assembled power driven blast pen door including top and bottom track and wheels locking arrangement , door bolts, top sealing plate, frame profiles, frame structural members internal/external covering base sheet cladding in all ,Captive Drive Unit , control pannel, connecting cables, electrical items in all respect incluidng installation with all fixing arrangement incluing M&L for construction of RCC foundations for all frames, excavations for foundationa and commissioning all as described in particular specifiction and as per dwgs approved in item 1 above for locations . | 4 | Each Job | 90,00,000 ₹3,60,00,000 | 70,00,000 ₹2,80,00,000 | 81,00,000 ₹3,24,00,000 | 62,00,000 ₹2,48,00,000 Lowest | 99,00,000 ₹3,96,00,000 | 88,95,756 ₹3,55,83,024 | 90,00,000 ₹3,60,00,000 |
| 3.00 | Demolition of Concrete of any description and in any position not otherwise specifically provided for ground floors and pavings of any thickness (below or above ground level) and including cutting of PQC slab till its complete depth with concrete cutting machine and removal and disposal of demolished concrete's debries to distance exc 250m but n.exc 500 m complete all as specified and directed by Engr-in-Charge . | 117 | Cum | 2,275 ₹2,66,175 | 2,500 ₹2,92,500 | 2,000 ₹2,34,000 | 200 ₹23,400 | 150 ₹17,550 | 90 ₹10,530 Lowest | 169 ₹19,773 |
| 4.00 | M&L for filling construction joint 25mm deep and 10mm wide (using diamond bit cutter of appropriate size ) providing polythene backup rod 12mm dia and sealed with polyurethane sealant (min depth of sealant 12 mm) complying with BS 5212, BS 4254 and En 41875-2003, priming the sides min MAF + 30% with ten years performance guarantee and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanical means all as shown drawing specified and as directed. | 18 | X RM | 9,950 ₹1,79,100 | 10,000 ₹1,80,000 | 6,000 ₹1,08,000 | 500 ₹9,000 Lowest | 1,200 ₹21,600 | 2,000 ₹36,000 | 1,150 ₹20,700 |
| 5.00 | M & L for brick work with sub class 'B' modular brick straight or curved on plan exc 6M mean radius built in cement mortar 1:6 complete all as specified and directed. | 14 | Cum | 6,475 ₹90,650 | 6,500 ₹91,000 | 5,500 ₹77,000 | 6,500 ₹91,000 | 4,200 ₹58,800 | 6,000 ₹84,000 | 4,000 ₹56,000 Lowest |
| 6.00 | M&L for 15mm thick cement plaster in CM 1:4 over concrete surfaces finished even and smooth without using extra cement complete all as specified and directed . | 135 | Sqm | 495 ₹66,825 | 450 ₹60,750 | 250 ₹33,750 | 250 ₹33,750 | 150 ₹20,250 Lowest | 420 ₹56,700 | 250 ₹33,750 |
| 7.00 | M&L for preparing of newly plastered surfaces of walls and applying two coats of white wash complete all as specified and directed . | 135 | Sqm | 199 ₹26,865 | 200 ₹27,000 | 350 ₹47,250 | 50 ₹6,750 | 40 ₹5,400 Lowest | 90 ₹12,150 | 45 ₹6,075 |
| 8.00 | M&L for Uprooting and grass cutting on traverse wall all as specified and as directed by Engr-in-Charge. | 1,000 | Sqm | 90 ₹90,000 | 100 ₹1,00,000 | 150 ₹1,50,000 | 50 ₹50,000 Lowest | 130 ₹1,30,000 | 110 ₹1,10,000 | 150 ₹1,50,000 |
| 9.00 | M&L for filling and raising earth ( For traverses ), upto 6 m height spreading in layer, watering, compacting and finishing to required gradient/ shape including bringing extra earth from outside ministry of defence (MOD) land deposited where directed all as specified and as directed. | 200 | Cum | 950 ₹1,90,000 | 1,000 ₹2,00,000 | 1,800 ₹3,60,000 | 400 ₹80,000 | 150 ₹30,000 Lowest | 510 ₹1,02,000 | 207 ₹41,400 |
| 10.00 | Supply & Fixing of nets of polyolefin all weather proof co-polymer, machine knotting using CNC machine with DSLS technology for anti slip knotting, mesh size 20mmx20mm and diameter of twine 01mm with 2mm dia border rope including 2mm dia tie ropes braided/ standard rope of polyolefin coplymers at an interval of 10ft having length of 6ft including fixing at any height / any location all as per manufacturers instructions complete all as specified and directed by Engr-in-charge. | 1,000 | Sqm | 475 ₹4,75,000 | 500 ₹5,00,000 | 400 ₹4,00,000 | 100 ₹1,00,000 Lowest | 250 ₹2,50,000 | 107 ₹1,07,000 | 600 ₹6,00,000 |
Tender Value
₹3.8 Cr
EMD Value
₹4.6 L
Closing Date
14 Aug 2025, 6:00 pmClosed
CE AF ZONE UDHAMPUR
HQ CE AF ZONE UDHAMPUR
ADDN/ALT TO BLAST PENS AT AF STATION PATHANKOT
2025_MES_720630_1
CEAFU/TOKEN-08/2025-26
Open Tender
Civil Works
Item Rate
456 days
PATHANKOT
AS PER TENDER DOCUMENTS AND POLICY IN VOGUE
10 documents required · 10 mandatory
₹2,000
GE AF PATHANKOT
₹4.6 L
UDHAMPUR
19 Sept 2025
15 Jul 2025
16 Aug 2025
15 Jul 2025
14 Aug 2025
7 Aug 2025
16 Jul 2025 - 21 Jul 2025
22 Jul 2025
Amount
Design of Power Driven sliding door including door pocket frame with claddings, other cladding top rail steel structure frame for support of steel trussed girder and steel column and its foundation in RCC, bottom rail and its foundation in RCC, captive drive unit, drive control panel equiped with and electrically operated brake, complete for 04 locations of entry and exit all as per design criteria, specification and as shown including undertaking soil investigation. Deliverable include (i) Detailed ARchitecture Dwg as per proposal of Scheme (i) Detailed structural GA Drawing (iii) Electrical GA and Schematic Dwd for Drivers (iv) Abstract of quantities and cost estimate, Yard stick. Tender purpose soil bearing capacity of nearby site enclosed. Building Dimensions Double entry Blast Pens as per Tabled below Location Minimum Clear Minimum Clear Maximum number Minimum Maximum number opening Width opening Height of Leaves allowed Track Length of Tracks allowed BP#15 Front 18.30M 07.00M 03 Three 24M 03 BP#15 Rear 18.30M 07.00M 03 Three 24M 03 BP#18 Front 18.30M 07.00M 03 Three 24M 03 BP#18 Rear 18.30M 07.00M 03 Three 24M 03
Fabrication, Erection and testing of factory made pre-assembled power driven blast pen door including top and bottom track and wheels locking arrangement , door bolts, top sealing plate, frame profiles, frame structural members internal/external covering base sheet cladding in all ,Captive Drive Unit , control pannel, connecting cables, electrical items in all respect incluidng installation with all fixing arrangement incluing M&L for construction of RCC foundations for all frames, excavations for foundationa and commissioning all as described in particular specifiction and as per dwgs approved in item 1 above for locations .
Demolition of Concrete of any description and in any position not otherwise specifically provided for ground floors and pavings of any thickness (below or above ground level) and including cutting of PQC slab till its complete depth with concrete cutting machine and removal and disposal of demolished concrete's debries to distance exc 250m but n.exc 500 m complete all as specified and directed by Engr-in-Charge .
M&L for filling construction joint 25mm deep and 10mm wide (using diamond bit cutter of appropriate size ) providing polythene backup rod 12mm dia and sealed with polyurethane sealant (min depth of sealant 12 mm) complying with BS 5212, BS 4254 and En 41875-2003, priming the sides min MAF + 30% with ten years performance guarantee and applying masking tape on edge of joint to prevent accidental spillage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanical means all as shown drawing specified and as directed.
M & L for brick work with sub class 'B' modular brick straight or curved on plan exc 6M mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for 15mm thick cement plaster in CM 1:4 over concrete surfaces finished even and smooth without using extra cement complete all as specified and directed .
M&L for preparing of newly plastered surfaces of walls and applying two coats of white wash complete all as specified and directed .
M&L for Uprooting and grass cutting on traverse wall all as specified and as directed by Engr-in-Charge.
M&L for filling and raising earth ( For traverses ), upto 6 m height spreading in layer, watering, compacting and finishing to required gradient/ shape including bringing extra earth from outside ministry of defence (MOD) land deposited where directed all as specified and as directed.
Supply & Fixing of nets of polyolefin all weather proof co-polymer, machine knotting using CNC machine with DSLS technology for anti slip knotting, mesh size 20mmx20mm and diameter of twine 01mm with 2mm dia border rope including 2mm dia tie ropes braided/ standard rope of polyolefin coplymers at an interval of 10ft having length of 6ft including fixing at any height / any location all as per manufacturers instructions complete all as specified and directed by Engr-in-charge.
M&L Providing and injecting low viscosity epoxy grout APCOREP INJECTION GROUT LV having viscosity 200-300 cps into concrete at 150mm to 300 mm centre to centre through Rohibb Injector & nylon nipples of 12 mm dia fixed into 14 mm dia drilled holes at 4-7 kg /cm2 pressure and heavy flexural strength of 110-130 kg / cm2 & bond strength of 80-100 kg / cm2. Grouting to be done in cracks till the nozzle refuses to accept the grout or it flows from the adjacent nozzle and removing the nipples & sealing it with non-shrink epoxy putty EPOXY SEAL. as per manufacturer instruction complete all as specified and directed by Engr-in-charge.
Taking down old unserviceable copper/aluminium point wiring( light,fan, socket or poer) complete including fitting and fixture such as switches, ceiling roses, pendentsregulators sockets, light fittingsetc removing materials to store for taking credit and making good disturbed surfaces of walls floors etc all sspecified and directed by Engr in charge.
M&L for point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLSH grade in and including In stove enamelled steel open conduit and conduit fittings and all accessories alongwith contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLSH grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Engr-in-charge (a) One light controlled by one , one way switch 5 amps complete all as specified and directed.
All as per ser item No 13 here-in-before but for 16 Amp socket outlets point controlled by one switch on Independent socket outlet using 2.5 sqmm PVC insulated and unsheathed FRLS copper conductor single core multi stranded flexible copper cable 1100V of approved colour code as per IS code for phase and neutral along with PVC insulated and unsheathed FRLS 2.5 sqmm multi stranded copper unsheathed cable 1100V (green color) as continuous earth lead wire connected to common earth and earth dolly complete all as specified and directed.
Supply and fixing Flame proof - weather proof switch/Isolator 10 Amp single pole ON/OFF complete all as specrified and directed Make Sudhir/shayam/Bajaj.
Supply and fix Flame proof - weather proof switch socket & plug combined 16 A,250 V(2P+Earth) complete all as specrified and directed Make Sudhir/shayam/Bajaj.
Supply and fix flame proof Flood light of capacity 120 Watt designed to operate in hazrdous environment where flammable gases or Vapours may present. It should ensure reliable illumination while preventing ignition. The fitting made of aluminum alloy (LM-6) expoy powder coated with in built box of FLP-WP, heat resistant clear glass cover includes fixing on wall and connection as per manufactures recommendations and suitable as per IS/IEC 60079-1. Temperature classification T6 and protection group IP-65 complete all as specified and directed..Make Sudhir/Crompton/Bajaj.
Supply and fixing factory made epoxy powder coated flame proof /weather proof distribution board TPN 8 ways with enclosure size 480x480x250 mm duly flushed on wall and suitable for universal mounting having bus bar not less tha 200 Amps copper neutral bus bar, stranded on DIN rail and cable ties for cable management complete including taking down old DB complete all as specified & directed.
Supplying & fixing in repl MCCB, 4 pole, 100 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified.
Supply and fixing MCB single pole 240 volt C curve 10 KA 5 to 32 Amps capacity all as specified and directed incl taking down old one.
M&L for preparing of old plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed by Engr-in Charge.
Supply and fixing MCB TPN 415 Volt C curve 10 KA 40 to 100 Amps capacity complete all as specified and directed incl taking down old one.
Supply and fix Flame proof - weather proof switch,socket and Industrial plug (PP06P) 32 Amps,415 volt,three phase,5 pin metal enclosure and socket all CIMR,BIS certified as specified and directed.Make Sudhir/shyam/Bajaj.
M&L for concealed sub main wiring using three single core PVC insulated, unseathed stranded copper conductor cable of size 6.0 Sqmm of voltage rarting upto and including 1100 volts drawn in and including steel conduit of dia not less than 25mm with all fittings and accessories, along with one run of steeel conduit insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Three runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
M&L for earthing complete with galvanised steel plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with 6mm dia M.S. round bar placed 75mm c/c and handle of 10mm dia, MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 1.75 meter long placed on top edge of earth plate, common salt & charcoal filling, funnel, wire mesh and earth work not exceeding 50 meters all as per electrical plate No 3 of SSR Part I (2009) and connected to earth test points all as specified and directed including testing on completion.
Material & Labour for earthing complete with copper earth plate elect rode 600x600x3mm thick buried directly in ground to a depth not less than 3 mtr deep below normal ground level with top edge of the earth plate not less than 2.25 mtr deep below normal ground level connected to copper strip 20x3mm size as earthing lead by means of soldering/brazing and bolts, nuts, check nuts and washers of brass, GI protection pipe light grade 40mm bore up to test point 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:2:4 type BI, RCC cover with suitable handle, earth pit filled with ground enhancing material i.e. mixture of copper sulphate, magnesia sulphate, graphite power etc mixed in equal quantity all around earth plate up to 150 cm and filled with vegetable soil above GEM up to ground level earth work in any type of soil all as required and directed including testing on completion. Make of chemical True power/JMV/Powertrac.
Supply and fix in replacement for copper strip 20x3.15 mm complete with saddles/ insulators made out of porcelain or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints /taking down all as required at site or directed by Engr In Charge.
Supply and fixing single pointed air termination aluminum rod 12mm dia 300mm long including necessary fixing arrangement with nuts bolts and washers etc complete all as specified and as directed by Engr-in - charge.
Supply and fixing Aluminum strip 25 x 3 mm with saddles and fixing screws etc. for roof conductors and down conductors with the help of porcelain insulator, saddles and screws on roof/wall above ground complete all as specified and as directed by Engineer-in-charge. Note :- 1. The distancebetween porcelain insulatorsshall not be more than 60 cm. 2. The quoted rates shall be deemedto includecost of porcelain insulators, T&P and Labour required to work on rooftop at lateral faces of Bldg.
S&F GI strip 32 mm x 6mm buried in ground through suitable size fixed on wall complete with Porcelain insulators, fixing screws, fastners nuts bolts washers complete all as directed by Engineer-In-Charge. .
Supply and erection of mounting structure of 1.5 mtrs height verticaly of GI Tubing medium grade 40 mm bore with MS plate for base suitable for roof mounting duly embedded in PCC 1:2:4 type B-1 block of size 30cmX30 cmX30 cm base on Building complete all as directed by Engr-in Charge
Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of welding,bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-I , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed by Engr in Charge.
M/L test point terminal block made of gun metal or phorphous bronze of size 75x75x25mm drilled and screwed incl 3 Nos x 8mm dia 25 mm long hexagonal head screws complete all as specified and directed by Engr in Charge.
S&F GI pipe light grade of size 40mm dia with all fitting laid in trenches/floors, road crossing or fixed to walls by suitable M S clamps for protection of copper/GI /aluminium strip complete all as specified and directed by Engr in charge.
S&F GI pipe light grade of size 50mm dia with al lfitting laid in trenches/floors or fixed to walls by suitable M S clamps for protection of copper/GI /aluminium strip complete all as specified and directed by Engr in charge.
S&F GI pipe light grade of size 80mm dia with al lfitting laid in trenches/floors or fixed to walls by suitable M S clamps for protection of copper/GI /aluminium strip complete all as specified and directed by Engr in charge.
Taking down old unserviceable LT cable any size retrieved complete all as specified and directed by Engr in charge.
Taking down old unserviceable LT Panel/ Bus Bar chamber any size or description complete all as specified and directed by Engr in charge.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 95 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete including cable lugs, jointing materials etc all as specified and as directed by Engr-in-Charge.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 50 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete including cable lugs, jointing materials etc all as specified and as directed by Engr-in-Charge.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 2 core 10 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete including cable lugs, jointing materials etc all as specified and as directed by Engr-in-Charge.
Supply, testing and commissioning of outdoor weather & dust vermin proof L.T. Panel board factory fabricated outdoor cubicle type totally enclosed .The Panels must be design and verified as per the IS/IEC 61439-01 & 2 with complete type test certificates for conformance to IS / IEC 61439 -1 and 2, with 65 KA 1 sec along with MCCB mounted in switch boards with aluminium bus bars as mandatory as conformed to IEC 61641 with internal arc containment fault level of 65 KA/03 Sec and shall be suiatbale for Seismeic Zone III/IV Zone including the type test conducted at ERDA/CPRI for seismic test.All MCCB panel should be single Tier for easy cable termination.Cable termination space should be adequate to safely gland and terminate al/cu cables for the given current ratings with Form B seperation for Incoming MCCB / ACB feeders and For Outgoing MCCB feeders. The Switch board cubicles shall have steel frame work enclosed on all sides and top by CRCA sheet steel of Minimum 2.00 mm thickness.The panel shall have integral base frame of 100 MM ISMC base channel.removeable undrilled gland plates shall be fitted for bottom cable entry.Incoming:- (a) MCCB 125 Amps 25 KA Four pole 415 volts fixed type with thermal magnetic release. - 01 No .It should be with adjustable load setting Ir = (0.8 to 1.0) x In,Tcs = 100 % Icu and with adjustable thermal setting. Incomer MCCB 400 Amp, 4 P should be thermal based release with adjustable O/L, Adjustable S/C setting Class II front face, 36 KA rupturing cap, Ics=100% Icu, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc Metering Section - Digital Ammeter (0-400) Amps, digital volt meter (0-500) Volts, RYB indicateing Lamps , 1Set Control fuses, CTs 3.Bus Bar Insulated Busbar of Aluminium of 200 A capacity for 4 phases, fixed on insulators, Busbars should be PVC sleeved with red. Yellow, Blue Colour, Busbar support should be of SMC/DMC - 1 set. Outgoing:- (a) MCCB 100 Amps 25 KA Four pole 415 volts fixed type with thermal magnetic release - 01 No (O/G) incl Spare - (1W +01 S). It should be with adjustable load setting Ir = (0.8 to 1.0) x In,Tcs = 100 % Icu and with adjustable thermal setting. Outgoing MCCB 400 Amp, four pole , should thermal based release with adjustable O/L, Adjustable S/C setting Class II front face, 36 KA rupturing cap, Ics=100% Icu, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc(b) MCCB 63 Amps 10 KA Four pole 415 volts fixed type with thermal magnetic release - 01 No (O/G) It should be with adjustable load setting Ir = (0.8 to 1.0) x In,Tcs = 100 % Icu and with adjustable thermal setting.Outgoing MCCB 63 Amp, Four pole , should be thermal based release with adjustable O/L, Adjustable S/C setting Class II front face, 36 KA rupturing cap, Ics=100% Icu, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc (c) MCB SPN 32 Amps ,220 Volt of breaking capacity not less than 10 KA - 01 Nos.
M&L boring of holes under road by trenchless technology using ultra sound technology and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressurefor laying of cables all as specified and directed by Engr in Charge.
Supplying, installing and commissioning of LT feeder box, outdoor type of size 0.90m x 0.60m x 0.50m, made out of MS sheet 3.15mm thick, legs made out of angle iron 40mmX40mmX6mm, 1.50m long (1.00m above ground level and 0.50m embedded in PCC (1:2:4), with openable shutter on both side (front and rear) having locking arrangement with 300 Amp rated aluminium bus bar suitable for 3 phase, 4 wire supply, drilled holes for cable connection, mounted on epoxy based post insulators and MCCB 4 pole, 160 Amp, 415 volt,with adjustable thermal and megnatic release with rupturing capacity 25 KA, incl necy PCC for foundation and coping all as specified and directed by Engr in Charge.
Supply and fixing LED flood light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with act and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr in Charge.
S & F cable route indicator at the distance of 50 mtrs each made out of 45 x 45 x 5 mm angle iron, 80 mm long embedded in PCC block of suitable size with moulded lettter LT CABLE suitably incribed on CI circular plate 8 mm thick 100 dia including painting with two coats of synthetic enamelled paint over a coat of red oxide primer including neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggrregate) block of suitable size and neccessary earth work and excavation all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in any type of soil for laying of cable complete all as specified and directed by Engineer-in-charge.
M&L Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25cm thick all as specified and directed by Engineer -in-charge.
M&L Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level not exc 1.5 mtr above the ground level/starting point compalete all as specified and directed.
M&L for Sand cushioning to the under ground electric cable as per SSR Part I 19.75 complete all as specified and directed by Engr in Charge.
Supply and laying un-reinforced pre cast concrete cable cover conforming to IS:5820 with minimum average breaking load capacity 200 kgs for unreinforced covers , class LV Type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for foundation of poles/stays or repair to hard standing floorsetc all as directed by Engr in charge.
M&L for PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate in coping including necessary form work finishingthe cement concrete surfaces even & smooth using extra cement etc all as directed by Engr in charge.
Providing and applying 5mm thick cementitious polyurethane sefl-smoothing anti static flooring on vacuum dewatered/ Heavy duty or other flooring min M25 grade as under:- (i) Carry out surface preparation including grinding / scarification / light shot blasting of concrete surface, proper cleaning, removing of loose mortar, paint residuals, curing compound residues, repairing of floor cracks and dents. (ii) Apply a 1mm scratch coat of PU concrete coating followed by 2mm thick PU concrete flooring and then laying of copper tape in grid format as per manufacturers specification, followed by laying of conductive middle coat ESD primer 100 microns DFT and finished with 2mm thick, dissipative grade polyurethane concrete coating system having compressive strength of => 40 Mpa, tensile strength of => 8 Mpa as per ASTM D 638, providing a resistance of 10-4 to 10-6 Ohm to be applied in desired colour and finish.(This shall be done using slow speed drill and poured on as per manufacturer’s specification. Than level the material using serrated trowel and the same with spiked nylon roller to remove slight trowel marks and entrapped air from the material.) (iii) Anchorage grooves should be cut to a minimum depth and width of 2mmX2mm the flooring thickness to be laid, at the edges, day jointes, up stands, drains, doorway including all tools and tackles as per manufacturer’s specifications and at regular points across the floor etc.
“Supply and fix Turbo forced exhaust Fan axial type having corrosion resistant body, minimal noise operation and maint free designed, totally enclosed heavy duty motor with pressure die cast aluminum rotor mounted on to ball bearing, aerodynamic concurred blades to handle maximum air with minimum power consumption having rigid frame with rubber mounting for silent operation conforming to IS : 2312-1967, single phase, IP -55 rated of min specification sweep 600mm ,240V , 50 Hz with air flow 3000 M3/h and noise level of 60 dB-65 dB. The same shall be provided as per approved design on the basis of the following:- The Blast pen is enclosed by power-driven sliding doors on both sides. When in the fully closed position, all three door panels on each side remain within designated wall pockets, creating enclosed volumes at either end of the pen. To ensure proper ventilation of the blast pen during closure and to maintain zero light ingress, the following provisions shall be made:- (i) Provision for Exhaust Fans : The contractor shall provide exhaust ventilation units of adequate capacity in each gate will pocket to extract air from the blast pen when the doors are in closed position. (ii) Mounting and configuration: (a) Exhaust fans shall be mounted within the sliding door pockets in such a way that they do not obstruct gate movement. (b) The installation shall ensure zero light transmission into the pen through use of light-proof louvers or baffles. (c) Fan mounting shall include weather proof, vermin-proof, and sound-dampened enclosures. (iii) Approval : (a) The detailed design, including location, mounting arrangement, noise control, and electrical connections , shall be carried out by the contractor and submitted alongwith the design of the gate for approval of GE. (b) The design shall be comply with relevant IS/IEC standards for industrial ventilation and motor protection. (iv) Power Supply: Power supply for exhaust fans shall be tapped from the existing motorized gate systems with appropriate protections, isolators, and wiring to be provided by the contractor. (v) Testing and Commissioning : The contractor shall test the system for airflow, automation, and sealing integrity. A minimum of 90% of the specified air follow capacity shall be demonstrated during testing. Make:- Havells/ Crompton/ Standard.
NOTE: Amount against schedule of credit of Rs. 43,670.00 for retrieved materials mentioned under relevant part of Sch of Credit of tender document in PDF form will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during acceptance of tender.
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd. (BID ID -3393497)
RSP Contractors India Private Limited (BID ID -3394141)
Standard engineers (BID ID -3394037)
M/S SINGH AND ASSOCIATES (BID ID -3393624)
M/S BHATIA BUILDERS AND CONTRACTORS (BID ID -3393455)
M/S KIRAN CONSTRUCTIONS (BID ID -3393506)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .