| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 CrAccepted-AOC | ₹24.7 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹28.9 CrRejected-AOC UNIT B2 AUTONAGAR VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹28.9 Cr | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹29.4 CrRejected-AOC | ₹29.4 Cr | L3 | Rejected-AOC NOT BEING LOWEST |
| 4 | L4₹29.9 CrRejected-AOC PLOT NO 178 A MLA COLONY ROAD NO 12 BANJARAHILLS HYDERABAD HYDERABAD TELANGANA 500034 | HYDERABAD | TELANGANA | 500034 | ₹29.9 Cr | L4 | Rejected-AOC NOT BEING LOWEST |
| 5 | L5₹30.4 CrRejected-AOC | ₹30.4 Cr | L5 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹25.2 Cr
EMD Value
₹15 L
Closing Date
20 Jan 2022, 6:00 pmClosed
CHIEF ENGINEER CHENNAI ZONE
CHIEF ENGINEER CHENNAI ZONE ISLAND GROUNDS CHENNAI 600 009
PROVISION OF TRAINING BAY FOR TANK T 90 FOR FEME AT MCEME SECUNDERABAD
2021_MES_481159_1
89050/E8
Open Tender
Civil Works
760 days
Secunderabad
As per tender documents and Appendix A to NIT
8 documents required · 8 mandatory
₹3,000
GARRISON ENGINER (MCEME) SECUNDERABAD
₹15 L
Yes
17 Feb 2022
29 Oct 2021
22 Jan 2022
29 Oct 2021
20 Jan 2022
7 Jan 2022
29 Oct 2021 - 17 Nov 2021
Amount
Lumpsum price worked out by the tenderer for BUILDINGS / STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for SITE CLEARANCE AND DEVELOPMENTS as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for RETAINING WALL as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for ROAD / PATH / CULVERT as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for STONE SETT APRON as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for FORDING PIT as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-XII
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XIII
Lumpsum price worked out by the tenderer for FIRE ALARM SYSTEM as listed in Schedule ‘A’ Part-XIV
Lumpsum price worked out by the tenderer for FIRE FIGHTING SYSTEM as listed in Schedule ‘A’ Part-XV
Lumpsum price worked out by the tenderer for COOLING APPLIANCES as listed in Schedule ‘A’ Part-XVI
Lumpsum price worked out by the tenderer for LIGHTNING PROTECTION SYSTEM as listed in Schedule ‘A’ Part-XVII
Lumpsum price worked out by the tenderer for DEMOLITION OF BUILDINGS as listed in Schedule ‘A’ Part-XVIII
SCHEDULE 'A' PART XIX (D G SET AND UPS SYSTEM) Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only.
Supply, transportation and safe delivery to site, unloading, safe storage, installation, testing and commissioning of 1 No. 380 KVA Diesel Generating Set, Phase & Neutral, 415 Volts, 50Hz as per Model No.QSN-14 G2 of Cummins or techno-commercially equivalent of other specified makes complete with CPCB-II Acoustic enclosure and Diesel Engine capable of delivering required BHP at 1500 RPM and coupled with 380 KVA, 415 Volts, 50 Hz Alternator 1500 RPM mounted on a common base from along with Engine mounted instrument panel complete all as per Srl Item No.1 of Sch 'A' Part- XIX (D G SET AND UPS SYSTEM)
Supply, Install, Testing and Commissioning of 15 KVA UPS with 3 Phase Input and 3 Phase Output with inbuilt isolation Transformer with Sealed Maintenance free Batteries 12 Volt 42 Amps 30 Nos to provide 30 Minutes backup including battery rack and complete interconnecting copper cables with and including lugs, incoming and outgoing overload protection by using MCCB along with enclosure of suitable size complete all as required for proper functioning of UPS as per the technical details of UPS specified in Srl Item No.2 of Sch 'A' Part- XV (D G SETS)
SCHEDULE 'A' PART XX (EOT CRANE) Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only.
Design, Manufacturing, assembly and inspection at manufacturer's works, packing, dispatch, transportation, safe delivery at site, required fabrication at site, installing, testing and commissioning of indoor type, Electric Overhead Travelling (EOT) Double Girder EOT Crane of 15 Ton capacity, 36 Meters Span, class II, M5 as per IS:3177 of 1999 and IS : 807 of 2006 and other relevant Indian standards of latest versions having straight travel path, operating on 415 volts, 3 phase, 50Hz, AC and with control voltage not exceeding 110 volts, AC through low voltage transformer with independent movable pendent supported by chain having lift of hook 6.6 metre above floor level, floor operated movable pendent control by means of push buttons independent of crab trolley position with protective panel with down shop lead, trailing cable complete with all accessories/ equipments duly epoxy painted complete as per OEM specification including performance testing etc, complete all as per Srl Item No.1 of Sch 'A' Part- XX (EOT CRANE)
SCHEDULE 'A' PART XXI (SOLAR POWER PLANT) Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only.
Design, procure, erect, install, testing and commission of Grid connected Solar Photovoltaic plant of 25 KW capacity including solar photovoltaic Module, DC cabling, AC cabling, Module Mounting Structures, Combining Boxes, Lightning Protection of SPV modules and other accessories, string inverter, 20KA DC SPD DC surge protector including connecting to local utility grid complete all as per Srl Item No.1 of Sch 'A' Part- XXI (SOLAR POWER PLANT)
SCHEDULE 'A' PART XXII (MISCELLANEOUS ITEMS) Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only.
INTERNAL WATER SUPPLY
Supply and Fix Wall mount Double Robe Hook, Chromium Plated all as per Cat No. CAN-1161N of Jaquar or techno-commercially equivalent of other specified makes etc., fixed to wooden cleats with C.P. brass screws including cutting wall/floor and making good the disturbed surfaces etc., complete all as specified and as directed.
Supply and Fix straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector etc., complete all as specified and as directed.
Supply and Fix Polypropylene (PP) pipes 110mm dia in sound proof piping system as per ON EN 1451-Part 1-6 & EN 12056 Part 1-5 with 3 layer pipe made of PP-C + PP-MV + PP-C in Blue Ral 5014 (halogen and calcium free) colour, push-fit type, food safe, having high impact and stiffness, offering sound levels of not more than 22 dBA at a flow rate of 4 l/s and having pipe ring stiffness as per 1S0/DIS 9969 and tightness as per EN 1277/B and C and DIN 19560, with all necessary fittings in blue colour, fitted with factory fitted lip ring . etc., complete all as specified and as directed.
Supply and Fix Polypropylene (PP) pipes 40/50mm Outer dia in sound proof piping system as per ON EN 1451-Part 1-6 & EN 12056 Part 1-5 with 3 layer pipe made of PP-C + PP-MV + PP-C in Blue Ral 5014 (halogen and calcium free) colour, push-fit type, food safe, having high impact and stiffness, offering sound levels of not more than 22 dBA at a flow rate of 4 l/s and having pipe ring stiffness as per 1S0/DIS 9969 and tightness as per EN 1277/B and C and DIN 19560, with all necessary fittings in blue colour, fitted with factory fitted lip ring . etc., complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY
Note for Sl. Item No.24.01 to 24.07: The new fittings shall bear the CA No. and Year written by Black synthetic enamel paint using stencils or by permanent marker pen and the unit quoted shall be deemed to include the cost of writing these details.
Supply, fix, test and commissioning of 25Watts Environment friendly, new generation, aesthetically, ultra modern designed Recess Mounted luminaire 2'x2' complete all as per Cat No.VENUSNEO HE2X2R18-42WLED840MODUGR<19 of Havells with Electronic driver as per Cat No. LEDDRIVER36V24WS of Havells or techno-commercially equivalent of other specified makes with all accessories pre-wired and including connecting up with flexible copper conductor of suitable size from ceiling rose to fitting complete all as specified and as directed..
Supply, fix, test and commissioning of 35/36Watts Environment friendly, new generation, aesthetically, ultra modern designed Recess Mounted luminaire 2'x2' complete all as per Cat No.VENUSNEOHE2X2R18-42WLED840MODU GR<19 of Havells with Electronic driver as per Cat No. LEDDRIVER36V24WS of Havells or techno-commercially equivalent of other specified makes with all accessories pre-wired and including connecting up with flexible copper conductor of suitable size from ceiling rose to fitting complete all as specified and as directed..
Supply, fix, test and commissioning of 15Watts LED aesthetically designed surface mounted Round panel light fixture all as per Cat No.LHEBFCP5IZ1W015 of Havells with surface accessories module as per Cat No. LSSLNW0131 of Havells or techno-commercially equivalent of other specified makes with all accessories pre-wired and including connecting up with flexible copper conductor of suitable size from ceiling rose to fitting complete all as specified and as directed..
Supply, fix, test and commissioning of surface and wall mounted LED batten 36 Watts, 4 Feet, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete with all fixing arrangement suitable for operating voltage 100 to 270 Volts, prewired with all accessories, complete all as per Cat No.DURABS40WLED865SPCSS of Havells or techno-commercially equivalent of other specified makes fixed on surfaces of wall or ceiling and connecting of flexible copper conductor cable twin core of suitable size from ceiling rose to fitting drawn through and including flexible conduit, fixed with suitable mounting clamps etc., complete all as specified and as directed.
Supply, fix, test and commissioning of 36 Watts, weatherproof, surface and wall mounted LED batten 4 Feet, energy saving, environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP66 luminaire with PC housing and opal finish cover suitable for wet location prewired with all accessories, complete all as per Cat No.MAGNUMGRANDGOLD 36WLED857SPCLILO of Havells or techno-commercially equivalent of other specified makes fixed on surfaces of wall or ceiling and connecting of flexible copper conductor cable twin core of suitable size from ceiling rose to fitting drawn through and including flexible conduit, fixed with suitable mounting clamps etc., complete all as specified and as directed.
Supply, fix, test and commissioning of Highbay luminaire - 180W LED energy saving, environment friendly & robust highbay led luminaire with high efficacy suitable for ceiling (surface/suspended) prewired with all accessories, complete all as per Cat No.RADIOSOHB180WLED75760 DBOPC of Havells or techno-commercially equivalent of other specified makes fixed on surfaces of wall or ceiling and connecting of flexible copper conductor cable of suitable size from ceiling rose to fitting drawn through and including flexible conduit, fixed with suitable mounting clamps etc., complete all as specified and as directed.
Supply, fix, test and commissioning of Highbay luminaire - 80W LED energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium Canopy fixture with high power leds as light source prewired with all accessories, complete all as per Cat No.FLARENEOCA80W LED757PSYMLTG of Havells or techno-commercially equivalent of other specified makes including junction box, connecting pipe, hanging arrangement, fixed and connecting of flexible copper conductor cable of suitable size from ceiling rose to fitting drawn through and including flexible conduit etc., complete all as specified and as directed.
Supply, fix, test and commissioning of Fire Exit Sign (RED illuminated) with Double sided LED signage with built-in battery Backup for 2 Hours all as per Cat No.220211 of Bajaj or techno-commercially equivalent of other specified makes fixed and connecting of flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed.
Supply, fix, test and commissioning of Wall mounting fan 300mm sweep 230 V, 50Hz, with 3 blades, adjustable upward and downward tilt mechanism, 60° oscillation, 1360 RPM, Min air delivery 55 Cum/minute, Thermal overload protection device etc., complete all as per Cat No. SWING 300 of Havells or techno-commercially equivalent of other specified makes with mounting accessories kit, prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply, fix, test and commissioning of Air circulator fans 600mm sweep 230 V, 50Hz, with 3 blades, metallic finish, Double ball bearings, adjustable upward and downward tilt mechanism, 60° oscillation, 1440RPM, Min air delivery 280 Cum/hour, Thermal overload protection device etc., complete all as per Cat No. TURBOFORCE WALL 600 of Havells or techno-commercially equivalent of other specified makes with mounting accessories kit, prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply, fix, test and commissioning of Heavy duty Exhaust fan, steel body, AC single Phase. 230V of size 600mm sweep with 4 blades, frame and louvers, 900 RPM, Min air delivery 10000 Cum/hour, double ball bearings, Thermal overload protection device etc., complete all as per Cat No.FHEHDTPDB249 (TURBOFORCE) of Havells or techno-commercially equivalent of other specified makes including provision of flexible copper cord of suitable size of required length from ceiling rose or connector to exhaust fan in flexible hose etc., complete all as specified and as directed.
Supply, fix, connecting and testing factory made, prewired Vertical type distribution board, (MCCB DB) TPN, 8 way, having degree of protection IP 43 with metal double door, 415 Volts, flush type made out of 1.2mm thick CRCA sheet metal, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar all as per Cat No.DHDMTVOSRW08 of Havells or techno-commercially equivalent of other specified makes with common neutral link earth bar, din bar for mounting MCBs, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCCBs, MCB TPN and MCB SP will be measured and paid separately.
Supply, fix, connecting and testing factory made, prewired Vertical type distribution board, (MCCB DB) TPN, 12 way, having degree of protection IP 43 with metal double door, 415 Volts, flush type made out of 1.2mm thick CRCA sheet metal, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar all as per Cat No.DHDMTVOSRW12 of Havells or techno-commercially equivalent of other specified makes with common neutral link earth bar, din bar for mounting MCBs, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCCBs, MCB TPN and MCB SP will be measured and paid separately.
Supply and Fix Telephone socket modular type RJ11 (01 module) all as per Cat No. 6772 62 of Legrand or techno-commercially equivalent of other specified makes etc., complete all as specified and as directed.
Supply and Fix RJ 45 cat 6 jack point modular type, 01 Module all as per Cat No.6792 65 of Legrand or techno-commercially equivalent of other specified makes etc., complete all as specified and as directed.
Material and labour for UTP 4 pair CAT 6 LAN Cable drawn through in the existing surface/ recessed Steel/ PVC conduit complete all as specified and as directed.
Material and labour for Two runs of 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable drawn through in the existing surface/ recessed Steel/ PVC conduit complete all as specified and as directed. Note : Two runs of 0.5mm dia telephone cable shall be considered as one unit length.
Supply, install, testing and commissioning of KRONE connector type main telephone tag block of 20 PAIRS in sheet metal enclosure of suitable dimensions fabricated out of 16 SWG sheet steel with castle key lock, hinged type cover including termination of telephone cables, making connections, painting of box etc. complete all as specified and as directed.
Supply, laying, testing and terminating with soldered terminals on both ends for 0.5 mm dia PVC insulated, PVC sheathed unarmoured annealed tinned copper conductor, telephone Cables SUITABLE FOR telephone tag block of 20 PAIRS conforming to ITD specification S/WS-113C & S/WS-114 on surface / recessed / false ceiling / cable Tray / GI pipe / Hume pipe etc. complete all as and as directed.
AREA DRAINAGE
Supply and FIx Medium duty Precast concrete, SFRC (Steel fiber reinforced cover) manhole cover with frame & gratings MHCF-17 suitable for Test load – 10 tonnes, weight not less than 340 Kg per Set conforming to IS 12592 Part –I & II complete all as specified and as directed.
Supply and Fix Medium duty Precast concrete, SFRC (Steel fiber reinforced cover) manhole cover with frame & gratings MHCF-18 suitable for Test load – 10 tonnes, weight not less than 340 Kg per Set conforming to IS 12592 Part –I & II complete all as specified and as directed.
RAIN WATER HARVESTING
Material and labour for Providing orange color safety foot rest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar conforming to IS:1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protrude legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specifications and having manufacturer's permanent identification make to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6, type C1 using 20mm graded stone aggregate complete as per design.
Supplying, assembling, lowering and fixing in vertical position in bore well, Unplasticized PVC (Slotted / Plain pipe) medium well casing (CM) pipe of 200 mm nominal dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories for all depths complete all as specified and as directed.
Material and labour for Providing and fixing Bail plug/ Bottom plug of 200 mm dia to the bottom of pipe assembly of tube well as per IS:2800 (part I), complete all as specified and as directed.
Supplying, filling, spreading and leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness including all leads and lifts complete all as specified and as directed.
Supplying, filling, spreading and leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer including all leads and lifts complete all as specified and as directed.
Supply and Fix Heavy duty Precast concrete, SFRC (Steel fiber reinforced cover) manhole cover with frame & gratings MHCF-02, 560mm internal dia suitable for Test load – 20 tonnes, weight not less than 230 Kg per Set conforming to IS 12592 Part –I & II complete all as specified and as directed.
Supply and Fix CI Gully Grating of size 650mm x 650mm complete all as shown in drawing and as directed.
EXTERNAL WATER SUPPLY
Construction of valve chamber of internal size 900 x 900 x 1000mm including necessary earth work excavation, 100mm thick PCC 1:4:8, type D2 using 40mm graded stone aggregate in foundation with 100mm offset, 200mm thick PCC solid block masonry walls built in CM 1:6, PCC 1:2:4 type B1 for coping, 15mm thick rendering in CM 1:4 for internal surfaces and external plaster up to a depth of 15cm below GL, including provision of 3.0mm thick MS sheet cover, double door, welded to 40 mm x 40 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brass and keys(Godrej/Shell), MS handles and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any kind of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 metre complete all as specified and as directed.
Supply, Install, testing and commissioning of horizontal mounted monoblock centrifugal transfer self priming pump set, electric operated with energy efficient motor conforming to IS:12615, having discharge capacity 100 LPM at 30m head, shaft made of stainless steel, SS-316 body and SS-316 impeller, mechanical seal, connected to a TEFC induction motor suitable for 415 volts ± 3% phase 50 cycles AC supply with a common suction header with valves on main connecting & pumps inlet and a common delivery header with valves, including control panel, water shock absorber, non return valves with MS galvanized supports and painting with one coat of primer and two coats of synthetic enamel paint including a 100mm dia pressure gauge, Vibration eliminating pads, Gland packing, fan cooled with suitable capacity, designed for automatic air release during priming, dynamically balanced rotating parts ensuring
minimum vibration during running, including provision of PCC foundation of suitable size with necessary base plate for pump set using angle iron of suitable size for base and frame supported by anti vibration pads as required at site including foundation bolts of suitable dia and length including electrical connections from starter to motor, necessary civil works & PCC works complete to with stand the vibrations all as per manufacturer's instructions and motor covering hood of hard plastic for protection from rain, making inlet/outlet pipes line connection using nuts, bolts, gaskets, pressure gauge etc., and other required material for smooth function of pump sets complete all as specified and directed.
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and /or flats wherever necessary including Cable gland plates provided on top as well as at the bottom of the panels and shall be treated with all anticorrosive process before painting as per specifications with two coats of red oxide primer and finally treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour, built in industrial type locking arrangement, 2 Nos. earthing terminals for 3 phase, 4 wire, 50 Hz supply system, Lifting hooks, Cadmium Plated hardwares, cables, cable trays, earthing (in accordance to specification) with earthing from panel to each motor / equipment complete and comprising of the following:-
Incoming:- (a) MCCB, 4 pole, 100 Amps with ultimate breaking capacity Icu-35kA at 415 Volts and thermal magnetic release conforming to IEC 60947 Part-I/IS-13947-Part-I with breaking capacity Ics=100%Icu at 415 Volts of 35 KA, overload setting 70% to 100%, short circuit setting 5 to 10 times & E/F protection- 02 Nos.
(b) Digital MFM meter and 3 nos. CTs of ratio 100/5A , Class I accuracy and 10 VA burden, digital multifunction meter suitable to measure voltage, Ampere, Frequency, Power Factor with RS-485 Port - 1 No. (c) ON/ OFF/TRIP Indicating LED Lamps with 2 Amp MCB - 1 Set (d) Phase indicating LED lamps set of three for RYB with 2 amp back up MCB.- 01 set (d) Bus Coupler MCCB, 4 pole, 100 Amps with ultimate breaking capacity Icu-35kA at 415 Volts and thermal magnetic release conforming to IEC 60947 Part-I/IS-13947-Part-I with breaking capacity Ics=100%Icu at 415 Volts of 35 KA, overload setting 70% to 100%, short circuit setting 5 to 10 times & E/F protection with 1 Set of ON/ OFF Indicating LED Lamps with 2 Amp MCB.- 01 No.
(h) Type-2 SPD 65kA 4P with 1No. (j) Red Indicator Light for SPD with 1Set. (k) SPD Back up fuse 1P 50A 20kA including all necessary accessories. - 1 No. Note: (i) Necessary Approval shall be taken from GE for each panel before fabrication. (ii) The unit rate quoted shall be deemed to include the cost of providing necessary cable alleys, internal wiring, and interlocking, earthing for all equipment. (iii) Provision shall be made to ensure system protection from dry running of the pump (iv) All incomers and Bus coupler breakers shall be electrical and mechanical interlocked with suitable accessories.
Supply and lay Galvanised steel water tubing medium grade 65mm bore conforming to IS specifications and ISI marked with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc., laid in trenches or on floors and testing for leakages etc., complete all as specified and as directed.
Supply and fix 65mm bore Gun metal, globe or gate valve, high pressure full way with brass spindle confirming to IS 778-1984 with iron wheel head at the top, screwed both ends for iron pipe and fixed complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY
Supply, Installation, testing and commissioning of Vacuum Circuit Breaker (VCB), HT 11 KV, 3 Phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker having rupturing capacity 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 630Amp complete all as specified and as directed, including the following:-
(a) 11KV 630 Amps. 350MVA, 18.6kA for 1sec. Electrically/ manually operated draw out type vacuum circuit breaker complete with trip free spring charged closing mechanism, necessary auxiliary relays, control switches, emergency hand trip devices and mechanical ON / OFF indicator etc. - (One) 1 No. (b) Multifunction Meter showing all Electrical Parameter ie Volt, Ampere, kw, kVA, P.F., kWH etc. - (One) 1 No. (c) Digital type ammeter with 11kV Cast resin CTs for metering (50/25 /5-5A, CL- 1, 15VA) with ASS and 2 Amp SP MCB - (One) 1 No. (d) voltmeter (0-15KV) with VSS-(One) 1No.
(e) Set of phase indication lamps with 2Amp SP MCB for protection (Red, Yellow and Blue) - (One) 1 Set. (f) Set of Red/ Green indicating lamp for close and open position - (One) 1 Set. (g) Amber indicating lamp for auto trip - (One) 1 No. (h) Clear indicating lamp for trip circuit healthy - (One) 1 No. (j) Blue indicating lamp for spring charged. - (One) 1 No. (k) Strip heater to prevent absorption of moisture. - (One) 1 No. (l) Set of 3 O/C + 1E/F (with High Set) Numerical Relay Micomp-127with 3 Nos. 11kV Resin Cast CTs 50/25/5-5A, CL 10P10, 15VA- (One) 1 Set
(m) Master Trip Relay and Trip circuit supervision relay (n) Potential Transformer 11KV/√3/110/√3 100VA burden - (one) 1 No. (o) Set of 3Element 24V DC Aux. Relay with H/R flag for tripping of Transformer Fault ie. OTI, WTI & Buchholz Tripping - 1 Set (p) Set of 3Element 24V DC Aux. Relay with H/R flag for Alarm of Transformer Fault ie. OTI, WTI & Buchholz Alarm - 1 Set (q) set of 8 Stage 24V DC Annunciator with built-in test/Accept/ Reset Push Button along with 24V DC Hooter - 1 Set (r) Master Trip Relay.
Supply, Installation, testing and commissioning of transformer, Plinth mounted type of capacity 750 KVA step down, Energy Efficiency Level 2, outdoor type, copper wound, vector group DYN, HT 11000 Volts, 3 phase, 50 Hz on primary side and 433 Volts, Oil immersed, 4 wire on secondary side, 50 Hz with off load tap changer having tappings on HT side to vary secondary voltage by +5% to - 7.5 % instep of 2.5%. complete with standard fittings, cable end box both on HT and LT side, LT terminals extended with 20 mm x 3 mm "L" type copper strip connected with bracing for connecting cable lugs on LT side including initial filling of oil conforming to IS 335-1981 and concrete plinth as specified in P.S. Clause 32.15.19.1 complete all as specified and as directed including the following and as per the following Technical Data Sheet:-
TECHNICAL DATA SHEET OF TRANSFORMER
Rating : 750 KVA
System : 11 KV/ 415Volts, 3Phase 4 wire, 50 Hz, AC supply
Type : Oil immersed
Cooling : ONAN
Service : OUTDOOR
Temperature Rise
In oil by thermometer : 45°C above 50° ambient
In winding by resistance : 50°C above 50° ambient
No. of windings/ Phase : TWO
Material of windings : COPPER
Rated Voltage (Line to Line)
High Voltage : 11000 Volts
Low Voltage : 415 Volts
Basic impulse level : As per IS-1180
Nominal Voltage : 11000Volts
Impulse : 75000 Volts (peak).
Power Frequency : 28000 Volts (RPM)
Inter-Phase Connections
High Voltage : DELTA
Low Voltage : Star (Neutral brought out for earthing).
Vector Group : DYn-11
Impendence : As per IS
Reactance : As per IS
Efficiency at 75º C (UPF)
at full Load : As per IS 1180 Standard
at 3/4 of full Load : As per IS 1180 Standard
at 1/2 of full Load : As per IS 1180 Standard
Regulation at : As per IS Standard
UPF : As per IS Standard
at 0.8 PF : As per IS 1180 Standard
No Load : As per IS 1180 Standard
Full Load Loss : As per IS 1180 Standard
Short circuit Rating of system : 250MVA
Tap changing Gear :
Type of Taps : OFF Load Tap Changing mechanism
Taps provided on : HV windings.
No. of taps : Seven
Range of Taps : +7.5% to -7.5% taps in steps of 2.25 %
Terminal Arrangement:
HV : Cable Box for 11KV 3 core x 95 Sq.mm Aluminium XLPE Cable.
LV : Cable BOX for 1.1KV 1250A Aluminium XLPE cable
Percentage Impedance : As per IS 2026 / IS 1180
RTCC Panel Indoor type with control cable
Buchholz Relay OTI and WTI
ALARM & TRIP CONTACTS.
Thermometer pocket with plug.
Sample or Drain valve with plug
Filter valve with plug and adopter
Man hole of sufficient size for access to interior.
Two Nos. Grounding/ Earthing terminals for body
Tank cover lifting eyes.
Bi-directional rollers
Jacking pads, hauling and lifting lugs.
Neutral bushing for LV windings
Rating plate and terminal marking plate.
Gas, Pressure & temperature protection relay wired & synchronized with HT panel by using alarm & trip contacts.
Oil level gauge
4 Nos plain solid cast steel detachable rollers.
Oil filling port on top cover with plate.
Extra bushing for neutral out side the cable box and providing independent earthing for neutral.
First fill transformer oil confirming to relevant IS.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for Main LT Panel (Outdoor duty), IP65 Protection Grade, made out of 3.15mm thick CRCA sheet with protected globe roof for rain water protection, dust proof, vermin proof, floor mounted with MS stand of 500mm height, free standing, outdoor type double door front and back opening type, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 3.15mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of shade as approved by GE and pre wired with
PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Mild Steel Angle iron frame of size 75mm x 75mm, 6mm thick duly painted and embedded in PCC 1:3:6, type C1, 30 CM above ground level and consisting the following:-
INCOMER 1 Incomer breaker 1250A 4P EDO ACB (Ics =50kA) with microprocessor based releases for over current, short ckt , earth fault with time delay from transformer etc. complete in all respects as mentioned in specifications below - 1 No.
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KVAR, KWH, Frequency / Harmonics etc. with 3 Nos. current transformers of 1250/5 ratio, 15 VA Class 1.0 metering.
Phase to phase, Phase to neutral & neutral to earth 7 mode spark gap surge suppressor for 200KA with appropriate fuses - 1No.
3 phase voltage monitoring relay cum phase sequence meter - 1No.
Red / Green / Amber ON/OFF & TRIP indicating lamps with 2A SP MCB backup protection - 1 Set
Three phase indicating lamps along with 2A SP MCB backup protection - 1 Set
Separate set of Class 5P10, 15VA CT of suitable capacity for protection/Capacitor Panel
Control MCB, control terminals& wiring as required.
INCOMER-2
Incomer breaker 800A 4P EDO ACB (Ics =50kA) with microprocessor based releases for over current, short ckt , earth fault. This incomer shall have 1 No. reverse power relay and manual start/ stop push button complete in all respect - 1 No.
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KVAR, KWH, Frequency / Harmonics etc. with 3 Nos. current transformers of 1250/5 ratio, 15 VA Class 1.0 metering.
Red / Green / Amber ON/OFF & TRIP indicating lamps with 2A SP MCB backup protection - 1 Set
Three phase indicating lamps along with 2A SP MCB backup protection - 1 Set
Control MCB, control terminals& wiring as required.
DG AMF LOGIC
Complete AMF logic along with cranking relays to start the DG incase of power failure and DG stopping incase of power restoration and AMF shall be microprocessor based with indication for DG ON/OFF and load ON.
In the case of failure of normal power supply
DG to start after a prefixed time of three second on any of the following conditions :
Total absence of voltage.
Failure of one or two phases.
Voltage below 380 volts.
After a lapse of 10-12 seconds normal power supply breaker to open and DG supply breaker to close.
All auxiliaries of DG sets to run automatically.
In the case of Resumption of Normal Power supply :
DG breaker to open and normal power supply breaker to close after 30 sec. on resumption of normal power on the following conditions.
All the three phases available at the normal supply breaker.
380-415 volts available at the normal supply breaker.
DG to over run for three minutes and stop automatically.
All auxiliaries to stop automatically.
DG to be ready for the next operation automatically.
Bus Coupler:
This will have electrically operated having 800A 4P EDO ACB (Ics =50kA) with ON/OFF/TRIP indicating lights. Bus coupler shall be interlocked electrically & mechanically with two incomers. Interlocking shall be done to avoid parallel operation of mains & DG supply shall be on either side of coupler can operate simultaneously with bus coupler open.
Bus Bar-1 :
High conductivity Aluminium three phase and neutral bus bars rated at 415V, 50 Hz., 1400 Amps, 50kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
Bus Bar-2 :
High conductivity Aluminium three phase and neutral bus bars rated at 415V,50 Hz., 1000 Amps, 50kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
Outgoings :
All outgoing feeders shall be provided with two set of 2A SP MCB backup protection and 1 Set of ON/OFF indicating lamps. All Outgoing MCCB's should have Ics=36kA
BUS BAR -1 :
400Amp 415 volt 4P MCCB with rotary handle. 1 no. digital MFM (showing all V/A/F/KW/ KWHr parameters) and matching cast resin Class-1 CT's - 2 Nos.
SPARE:
400Amp 415 volt 25 KA 4P MCCB with rotary handle - 1 No.
SPACE:
SPACE suitable for TPN feeder having 250A 4P MCCB - 1 No.
BUS BAR -2 :
250Amp 415 volt 4P MCCB with rotary handle. 1 no. digital MFM (showing all V/A/F/KW/ KWHr parameters) and matching cast resin Class-1 CT's - 1 No.
125Amp 415 volt 4P MCCB with rotary handle. 1 no. digital MFM (showing all V/A/F/KW/ KWHr parameters) and matching cast resin Class-1 CT's - 4 Nos.
63Amp 415 volt 4P MCCB with rotary handle. 1 no. digital KWH (showing KW/ KWHr parameters) and matching cast resin Class-1 CT's - 3 Nos.
SPARE:
125Amp 415 volt 25 KA 4P MCCB with rotary handle - 1 No.
63Amp 415 volt 25 KA 4P MCCB with rotary handle - 1 No.
SPACE:
SPACE suitable for TPN feeder having 125A 4P MCCB - 1 No.
Control wiring, MCB, ferruling, danger plate, name plates etc complete all as specified and as directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for 300 KVAR Capacitor Panel (Outdoor duty), IP-65 Protection grade made out of 3.15mm thick CRCA Sheet with protected globe roof for rain water protection, dust proof, vermin proof, floor mounted with MS stand of 500mm height, free standing, outdoor type double door front and back opening type, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 3.15mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted
with epoxy powder coated mat finish of shade as approved by GE and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Mild Steel Angle iron frame of size 75mm x 75mm, 6mm thick duly painted and embedded in PCC 1:3:6, type C1, 30 CM above ground level and consisting the following:-
Capacitor panel shall be 300 KVAR (1 x 100 KVAR + 2 x 50 KVAR + 2 x 25 KVAR + 2 x 15 KVAR + 2 x 10 KVAR). These capacitor values should be net at 415V and accordingly capacitors shall be derated at 525V. Minimum 500 CFM fan will be used for air cooling. Capacitor panel shall be expendable type.
INCOMER:
300 KVAR at 480V capacitor panel having 1 No. 630Amps TP Isolator Ics=36kA as incomer. Incomer shall have 3 Nos. indicating lights with control MCB for incoming power, 1 No., Multifunction meter showing V/A/PF parameters with matching cast resin CT's, 3 phase 10 set automatic power factor correction relay.
BUS BAR:
A set of TPN Aluminium bus bar rated for 700A (after derating factor of 0.75) 3 phase 4wire, 50Hz System. The bus bar size after derating shall be equal to the ampere given in the BOQ The conductivity of bus bar shall not be less than 58% and earth bus size shall be 10% of phase bus bar. Neutral Bus Bar is 50% capacity of phases.
OUTGOINGS:
1 No. x 10 KVAR capacitor banks each having 10 KVAR (should offer net capacitance of 10 KVAR at 525V) section will have 40A TP MCCB , 1 No. 10KVAR Heavy duty capacitor rated at 525V and 1 set lights ON/OFF.
Each capacitor bank shall be able to operate in either manual or auto mode individually through APCR relay and separately in auto mode. Actual capacitance value will be high at 415V and each capacitors should be derated to offer value given above at 480V.
1 set of complete wiring
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for UPS Panel - 1 in Ground Floor (Indoor duty), IP-55, dust proof, vermin proof, front operated, dead back access, floor mounted, indoor type separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 2.00mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of shade as approved by GE and pre wired with
PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel of size not less than 1.0m x 1.0m x 0.35m shall be mounted on floor level and embedded with 40 x 40 x 4mm MS Angle Iron frame complete all as directed and consisting the following:-
125 Ampere DP MCCB, 25KA with ON/OFF indications complete in all respects as mentioned in specifications - 1No.
Control MCB, control terminals & wiring as required.
Bus Bars:
High conductivity Aluminium Single phase and neutral bus bars rated at 230V, 50 Hz., 150 Amps insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
Outgoings :
63 amps 16 kA 230 volt grade DP MCCB - 1 No.
40 amps 16 kA 230 volt grade DP MCCB - 3 Nos.
SPARE:
40 amps 16 kA 230 volt grade DP MCCB - 3 Nos.
Control wiring, MCB, ferruling, danger plate, name plates etc complete all as specified and as directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for UPS Panel - 2 in Ground Floor (Indoor duty), IP-55, dust proof, vermin proof, front operated, dead back access, floor mounted, indoor type separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 2.00mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of shade as approved by GE and pre wired with
PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs. Panel of size not less than 1.0m x 1.0m x 0.35m shall be mounted on floor level and embedded with 40 x 40 x 4mm MS Angle Iron frame complete all as directed and consisting the following:-
63 Ampere DP MCB 25 kA with ON/OFF indications complete in all respects as mentioned in specifications - 1No.
Control MCB, control terminals & wiring as required.
Bus Bars:
High conductivity Aluminium Single phase and neutral bus bars rated at 230V,50 Hz., 100 Amps insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
Outgoings :
40 amps 16 kA 230 volt grade DP MCCB - 1 No.
32 amps 16 kA 230 volt grade DP MCCB - 1 No.
SPARE:
40 amps 16 kA 230 volt grade DP MCCB - 1 No.
32 amps 16 kA 230 volt grade DP MCCB - 1 No.
Control wiring, MCB, ferruling, danger plate, name plates etc complete all as specified and as directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for Lighting Panel - 1 in Ground Floor (Indoor duty), IP-55, dust proof, vermin proof, front operated, dead back access, floor mounted, indoor type separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 2.00mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of shade as approved by GE and pre wired with
PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel of size not less than 2.20m x 1.6m x 0.35m shall be mounted on floor level and embedded with 40 x 40 x 4mm MS Angle Iron frame complete all as directed and consisting the following:-
Incomer MCCB Ics=36kA
160 Ampere TPN MCCB with isolable neutral having over current, Earth fault and short circuit protections with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required - 1No.
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KVAR, KWH, Frequency etc. with 3 Nos. Current Transformers of 125/5 ratio, 15 VA Class 1.0 metering.
Red/Green/Amber ON/OFF indicating lamps with 2A SP MCB backup protection.
1 set of three phase indicating lamps along with 2A SP MCB backup protection.
Control MCB, control terminals& wiring as required.
Bus Bars:
High conductivity Aluminium three phase and neutral bus bars rated at 415V,50 Hz., 200 Amps, 25kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
Outgoings :
63 amps 16 kA 415 volt grade 4P MCCB. - 1 No.
40 amps 16 kA 415 volt grade 4P MCCB - 1 No.
40 amps 16 kA 230 volt grade DP MCCB - 1 No.
SPARE:
63 amps 16 kA 415 volt grade 4P MCCB. - 2 Nos.
40 amps 16 kA 415 volt grade 4P MCCB - 1 No.
40 amps 16 kA 230 volt grade DP MCCB - 1 No.
Control wiring, MCB, ferruling, danger plate, name plates etc complete all as specified and as directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for Lighting Panel - 2 in Ground Floor (Indoor duty), IP-55, dust proof, vermin proof, front operated, dead back access, floor mounted, indoor type separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 2.00mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of shade as approved by GE and pre wired with
PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel of size not less than 1.80m x 1.70m x 0.35m shall be mounted on floor level and embedded with 40 x 40 x 4mm MS Angle Iron frame complete all as directed and consisting the following:-
Incomer MCCB Ics=36kA
125 Ampere TPN MCCB with isolable neutral having over current, Earth fault and short circuit protections with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required - 1No.
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KVAR, KWH, Frequency etc. with 3 Nos. current transformers of 125/5 ratio, 15 VA Class 1.0 metering.
Red/Green/Amber ON/OFF indicating lamps with 2A SP MCB backup protection.
1 set of three phase indicating lamps along with 2A SP MCB backup protection.
Control MCB, control terminals& wiring as required.
Bus Bars:
High conductivity Aluminium three phase and neutral bus bars rated at 415V,50 Hz., 200 Amps, 25kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
Outgoings :
63 amps 16 kA 415 volt grade 4P MCCB. - 1 No.
40 amps 16 kA 415 volt grade 4P MCCB - 4 Nos.
40 amps 16 kA 230 volt grade DP MCCB - 2 Nos.
SPARE:
63 amps 16 kA 415 volt grade 4P MCCB. - 2 Nos.
63 amps 16 kA 230 volt grade DP MCCB - 1 No.
40 amps 16 kA 230 volt grade DP MCCB - 2 Nos.
Control wiring, MCB, ferruling, danger plate, name plates etc complete all as specified and as directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for Lighting Panel - 3 in First Floor (Indoor duty), IP-55, dust proof, vermin proof, front operated, dead back access, floor mounted, indoor type separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 2.00mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of shade as approved by GE and pre wired with
PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel of size not less than 2.20m x 1.50m x 0.35m shall be mounted on floor level and embedded with 40 x 40 x 4mm MS Angle Iron frame complete all as directed and consisting the following:-
Incomer MCCB Ics=36kA
160 Ampere TPN MCCB with isolable neutral having over current, Earth fault and short circuit protections with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required - 1No.
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KVAR, KWH, Frequency etc. with 3 Nos. current transformers of 125/5 ratio, 15 VA Class 1.0 metering.
Red/Green/Amber ON/OFF indicating lamps with 2A SP MCB backup protection.
1 set of three phase indicating lamps along with 2A SP MCB backup protection.
Control MCB, control terminals& wiring as required.
Bus Bars:
High conductivity Aluminium three phase and neutral bus bars rated at 415V,50 Hz., 200 Amps, 25kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
Outgoings :
63 amps 16 kA 415 volt grade 4P MCCB. - 3 Nos.
40 amps 16 kA 415 volt grade 4P MCCB - 5 Nos.
32 amps 16 kA 415 volt grade 4P MCCB - 2 Nos.
SPARE:
63 amps 16 kA 415 volt grade 4P MCCB. - 1 No.
40 amps 16 kA 415 volt grade 4P MCCB - 2 Nos.
32 amps 16 kA 415 volt grade 4P MCCB - 1 No.
Control wiring, MCB, ferruling, danger plate, name plates etc complete all as specified and as directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for Lighting Panel - 4 in First Floor (Indoor duty), IP-55, dust proof, vermin proof, front operated, dead back access, floor mounted, indoor type separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 2.00mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of shade as approved by GE and pre wired with
PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel of size not less than 2.0m x 1.50m x 0.35m shall be mounted on floor level and embedded with 40 x 40 x 4mm MS Angle Iron frame complete all as directed and consisting the following:-
Incomer MCCB Ics=36kA
125 Ampere TPN MCCB with isolable neutral having over current, Earth fault and short circuit protections with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required - 1No.
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KVAR, KWH, Frequency etc. with 3 Nos. current transformers of 125/5 ratio, 15 VA Class 1.0 metering.
Red/Green/Amber ON/OFF indicating lamps with 2A SP MCB backup protection.
1 set of three phase indicating lamps along with 2A SP MCB backup protection.
Control MCB, control terminals& wiring as required.
Bus Bars:
High conductivity Aluminium three phase and neutral bus bars rated at 415V,50 Hz., 200 Amps, 25kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
Outgoings :
40 amps 16 kA 415 volt grade 4P MCCB. - 7 Nos.
32 amps 16 kA 415 volt grade 4P MCCB - 2 Nos.
SPARE:
63 amps 16 kA 415 volt grade 4P MCCB. - 1 No.
40 amps 16 kA 230 volt grade DP MCCB - 2 Nos.
Control wiring, MCB, ferruling, danger plate, name plates etc complete all as specified and as directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for Training Equipment Panel - 1 in Gound Floor (Indoor duty), IP-55, dust proof, vermin proof, front operated, dead back access, floor mounted, indoor type separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 2.00mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of shade as approved by GE and pre wired with
PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel of size not less than 1.50m x 1.20m x 0.35m shall be mounted on floor level and embedded with 40 x 40 x 4mm MS Angle Iron frame complete all as directed and consisting the following:-
Incomer MCCB Ics=36kA
400 Ampere TPN MCCB with isolable neutral having over current, Earth fault and short circuit protections with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required - 1No.
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KVAR, KWH, Frequency etc. with 3 Nos. current transformers of 125/5 ratio, 15 VA Class 1.0 metering.
Phase to phase 4 mode spark gap surge suppressor with appropriate fuses - 1 No.
Red/Green/Amber ON/OFF indicating lamps with 2A SP MCB backup protection.
1 set of three phase indicating lamps along with 2A SP MCB backup protection.
Control MCB, control terminals& wiring as required.
Bus Bars:
High conductivity Aluminium three phase and neutral bus bars rated at 415V,50 Hz., 500 Amps, 25kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
Outgoings :
160Amp 415 volt 25 KA 4P MCCB with rotary handle. ON Indication. - 4 Nos.
SPARE:
160Amp 415 volt 25 KA 4P MCCB with rotary handle. ON Indication - 1 No.
Control wiring, MCB, ferruling, danger plate, name plates etc complete all as specified and as directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for Training Equipment Panel - 2 in Gound Floor (Indoor duty), IP-45, dust proof, vermin proof, front operated, dead back access, floor mounted, indoor type separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 2.00mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of shade as approved by GE and pre wired with
PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel of size not less than 1.0m x 1.20m x 0.35m shall be mounted on floor level and embedded with 40 x 40 x 4mm MS Angle Iron frame complete all as directed and consisting the following:-
Incomer MCCB Ics=36kA
400 Ampere TPN MCCB with isolable neutral having over current, Earth fault and short circuit protections with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required - 1No.
Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KVAR, KWH, Frequency etc. with 3 Nos. current transformers of 125/5 ratio, 15 VA Class 1.0 metering.
Phase to phase 4 mode spark gap surge suppressor with appropriate fuses - 1 No.
Red/Green/Amber ON/OFF indicating lamps with 2A SP MCB backup protection.
1 set of three phase indicating lamps along with 2A SP MCB backup protection.
Control MCB, control terminals& wiring as required.
Bus Bars:
High conductivity Aluminium three phase and neutral bus bars rated at 415V,50 Hz., 500 Amps, 25kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
Outgoings :
160Amp 415 volt 25 KA 4P MCCB with rotary handle. ON Indication. - 3 Nos.
SPARE:
160Amp 415 volt 25 KA 4P MCCB with rotary handle. ON Indication - 2 Nos.
Control wiring, MCB, ferruling, danger plate, name plates etc complete all as specified and as directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for External Light Feeder pillar (Indoor duty), IP-45, dust proof, vermin proof, front operated, dead back access, wall mounted, indoor type separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 2.00mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of shade as approved by GE and pre wired with
PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel of size not less than 0.70m x 0.60m x 0.35m shall be mounted on floor level and embedded with 40 x 40 x 4mm MS Angle Iron frame complete all as directed and consisting the following:-
Incomer
40 Amp DP MCCB (10 KA) with On / Off indications in the front. - 1No.
Outgoings :
DP MCB-10Amps-C Series 10 KA - 3 Nos.
2 Pole Contactor with a thermal rating of 10A - 3 nos.
Time Switch with Daily dial, suitable for operation on 230 Volt, Single phase, 50 Hz, AC Supply - 3 Nos.
16 amps 10 kA 230 volt grade DP MCB - 2 Nos.
Control wiring, MCB, ferruling, danger plate, name plates etc complete all as specified and as directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board for Crane Panel (Indoor duty), IP-55, dust proof, vermin proof, front operated, dead back access, wall mounted, indoor type separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders with the extendable main and auxiliary bus bars, interconnection, earth bus CPRI approved factory made fabricated out of CRCA sheet not less than 2.00mm thick for all load baring members, doors, side partitions as per IS: 8623-93 standards and duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of shade as approved by GE and pre wired with
PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel of size not less than 1.0m x 0.80m x 0.30m shall be mounted on floor level and embedded with 40 x 40 x 4mm MS Angle Iron frame complete all as directed and consisting the following:-
Incomer
63 Amp FP MCCB (16 KA) with On / Off indications in the front. - 1No.
Outgoings :
40 amps 10 kA 415 volt grade 4P MCCB. - 1 No.
32 amps 10 kA 415 volt grade 4P MCCB - 1 No.
SPARE:
40 amps 10 kA 415 volt grade 4P MCCB. - 1 No.
Control wiring, MCB, ferruling, danger plate, name plates etc complete all as specified and as directed.
Supply and lay in trenches/drawn through pipes or in road crossings/ paths/drains/ ducts/ floors/ along poles/ cable racks or trays or pipes, equipments etc., of LT cable PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor 1100 volts grade confirming to IS-7098 (Part-I) 1988 of size 12 core x 2.50 Sqmm including termination at both end for cable connection etc., complete all as specified and as directed.
Supply and lay in trenches/drawn through pipes or in road crossings/ paths/drains/ ducts/ floors/ along poles/ cable racks or trays or pipes, equipments etc., of LT cable PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor 1100 volts grade confirming to IS-7098 (Part-I) 1988 of size 10 core x 2.50 Sqmm including termination at both end for cable connection etc., complete all as specified and as directed.
Supply and lay in trenches/drawn through pipes or in road crossings/ paths/drains/ ducts/ floors/ along poles/ cable racks or trays or pipes, equipments etc., of LT cable PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor 1100 volts grade confirming to IS-7098 (Part-I) 1988 of size 4 core x 2.50 Sqmm including termination at both end for cable connection etc., complete all as specified and as directed.
Supply and lay DWC HDPE pipe, 110mm dia (OD 110mm and ID 95mm nominal dia) PN 10, ISI marked with all fittings like socket, bend, couplers etc. as required conforming to IS 14930, Part II including cutting, jointing, fixed to walls, pole ceiling or laid in trenches/ floor for cable protection at road crossing / on poles etc., complete all as specified and as directed.
Supply and lay DWC HDPE pipe, 160mm dia (OD 160mm and ID 135mm nominal dia) PN 10, ISI marked with all fittings like socket, bend, couplers etc. as required conforming to IS 14930, Part II including cutting, jointing, fixed to walls, pole ceiling or laid in trenches/ floor for cable protection at road crossing / on poles etc., complete all as specified and as directed.
Supply and lay DWC HDPE pipe, 200mm dia (OD 200mm and ID 175mm nominal dia) PN 10, ISI marked with all fittings like socket, bend, couplers etc. as required conforming to IS 14930, Part II including cutting, jointing, fixed to walls, pole ceiling or laid in trenches/ floor for cable protection at road crossing / on poles etc., complete all as specified and as directed.
Supply and Fix perforated cable tray with cover of size 100 mm width X 50 mm depth with perforation not more than 17.5% made out of 16 gauge (1.60mm thick) CRCA sheet and painted with powder coating of tint as approved by GE including horizontal and vertical bends, reducers, tees, cross-members and other accessories as required and joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts etc., complete all as specified and as directed.
Supply and Fix perforated cable tray with cover of size 150 mm width X 50 mm depth with perforation not more than 17.5% made out of 16 gauge (1.60mm thick) CRCA sheet and painted with powder coating of tint as approved by GE including horizontal and vertical bends, reducers, tees, cross-members and other accessories as required and joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts etc., complete all as specified and as directed.
Supply and Fix perforated cable tray with cover of size 300 mm width X 50 mm depth with perforation not more than 17.5% made out of 16 gauge (1.60mm thick) CRCA sheet and painted with powder coating of tint as approved by GE including horizontal and vertical bends, reducers, tees, cross-members and other accessories as required and joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts etc., complete all as specified and as directed.
Supply and Fix perforated cable tray with cover of size 450 mm width X 50 mm depth with perforation not more than 17.5% made out of 2.00mm thick CRCA sheet and painted with powder coating of tint as approved by GE including horizontal and vertical bends, reducers, tees, cross-members and other accessories as required and joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts etc., complete all as specified and as directed.
Supply only Electric rubber hand gloves suitable for working with 11 KV electrical work
Supply, fix, test and commissioning of compact all in one Solar LED Street light 40 watt (with built-in Lithium Ferro Phosphate Batteries, Monocrystalline Solar Panel and MPPT charge controller) and including 6.0metre Octagonal pole all as per Philips Model No BRP110 LED 85/757 (or) Surya Model No SSLE SIS 40w LFP W2 NP SOLAR (or) Crompton Model No. CSADSMP40 CDL NC or techno-commercially equivalent of other specified make complete in all respect including foundation in PCC 1:3:6, type C1, Earthwork excavation, Returning filling in and removal of soil, etc., complete all as specified and as directed.
Supply and fix cable route indicator made out of round CI disc embossed HT Cable, of size 15cm dia, 10mm thick duly revited with angle of size 50 x 50 x 4mm and 60cm long including embedded in PCC 1:2:4 type B1 (using 20mm graded aggregate) grouting 15cmx15cmx15cm etc., complete all as specified and as directed.
FIRE ALARM SYSTEM
Supply, install, testing and commissioning of Networkable & Microprocessor based 640 ‐ characters LCD / Touch Screen LCD Display Network Repeator panel equipped with Mounting options etc. (UL Approved) and shall Display all events / detectors, devices status of complete systems in the network complete all as specified and as directed.
Supply and lay of cabling for fire detection and alarm system with 2 Core x 1.5 Sq.mm Copper Unarmoured cable complete all as specified and as directed.
Supply and lay of cabling for fire detection and alarm system with 8 Core x 1.5 Sq.mm Copper Unarmoured cable from Main Fire Alarm Panel to Repeater Panel (1 Pair for Power Supply, 2 Pairs for 2 zones & 1 Pair extra ) complete all as specified and as directed.
FIRE FIGHTING SYSTEM
Material and labour for Providing Steel door with glazed shutter of size 0.90m x 2.10m made out of using 40mm x 40mm x 6mm angle iron for door frame and fixed with 2mm thick stainless sheet and glazed shutter made out of 6mm thick plain sheet glass fixed over 25mmx25mmx3mm angle frame all around and stiffened in between including provision of hinges, handle, locking arrangement etc., and painting the Mild steel surfaces with two coats of synthetic enamel paint of tint as approved by GE over a coat of red oxide primer and writing Sign on glass at internal hydrant complete all as specified and as directed.
Supply, installation, testing and commissioning of ISI Marked CO2 type Fire Extinguisher 22.5 Kg. capacity conforming to IS:16018 made from seamless cylinder conforming to IS: 7285 duly approved by Chief Controller of Explosive, Nagpur, fitted with ISI Marked Controlled Valve conforming to IS:3224, high pressure 5 mtr. long discharge hose and horn complete with initial gas charged mounted on Trolley Wheels, suitable for operating between -30 degree C to +55 degree C, Fire Rating Class -13B complete all as specified and as directed.
Supply, installation, testing and commissioning of 25 KG Dry chemical trolley mounted Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with dry chemical complete in all respects including trolley and conforming to IS:15683 etc., complete all as specified and as directed.
Material and labour for providing, testing and commissioning of MS air cushion tank on top of each riser fabricated from 6mm thick MS plate, 200 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MS plate with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS 4736-1968 complete all as specified and as directed.
Supply, install, testing and commissioning of Fire Extinguisher, Carbon-di-oxide type capacity 6.5 Kg, ISI marked conforming to IS:15683, Flat base including valve, discharge hose of not less than 10 mm dia, 1M long including initial fill with CO2 gas conforming to IS:307-1966 and wall suspension bracket as required etc., complete all as specified and as directed.
Supply, install, testing and commissioning of Dry chemical powder, wall mounted Fire Extinguisher, ABC (Powder Type) of capacity 6kg with Mild Steel Cylinders ISI marked, conforming to IS:15683 fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen including wall suspension bracket as required etc., complete all as specified and as directed.
Supply and Fix 100 mm reinforced neoprene rubber vibration eliminators/ expansion joints (to provide relief from stresses at pipe flanges) suitable for upto 20 kg/cm2 pressure, complete all as specified and as directed.
Supply, installation, testing and commissioning of ISI Marked CO2 type Fire Extinguisher 3 Kg capacity conforming to IS:15683:2006 made from seamless cylinder conforming to IS:7285 duly approved by Chief Controller of Explosive, Nagpur, fitted with ISI Marked Controlled Valve conforming to IS:3224, discharge adaptor and horn complete with initial gas charged with carrying handle wall mounting bracket, suitable for operating between - 30 degree C to + 55 degree C, Fire Rating Class - 13B complete all as specified and as directed.
Supply, installation, testing and commissioning of 9 Litre water stored pressure type wall mounted Fire Extinguisher with Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve complete in all respects including wall suspension bracket complete all as specified and as directed.
Design, Supply and fix Steel sheet enclosure, weather proof, dust proof suitable for monoblock booster pump set made out of Mild steel sheet 3.0 mm thick dust proof, duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of tint as approved by GE etc., complete all as specified and as directed.
COOLING APPLIANCES
Supply and fix voltage stabilizers for automatic operation single phase naturally air cooled indoor type and design for input variation between 170 volts to 250 volts with out put voltage stabilizer at 230 volts with accuracy of ± 2.5% and of capacity 2.0 KVA complete all as specified and as directed.
GOPAL TEKNOCON PRIVATE LIMITED
R. Wadhumal and Sons
SRICO PROJECTS PVT LTD
Sukhdevraj Sharma Engineers & Contractors Pvt Ltd
VERMA BROTHERS
SOOD ASSOCIATES PVT LTD
Indus Projects Private Limited
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid