Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC | ₹39.3 L Quoted ₹42.0 L | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹43.1 LRejected-Finance | ₹43.1 L | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹48.5 LRejected-Finance 580 INDRA COLONY JAISALMER RAJASTHAN 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | ₹48.5 L | L3 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | Bhawani Enterprises L2 | M/s Advance Stage Lights L1 | HINGLAZ ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site. | 562 | Cum | 175 ₹98,350 | 130 ₹73,060 | 110 ₹61,820 |
| 2.00 | M&L for tibba Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. | 202 | Cum | 175 ₹35,350 | 150 ₹30,300 | 200 ₹40,400 |
| 3.00 | M& L for 40 to 50 mm thick rough dressed Jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cableall as specified and directed. | 3,125 | Each | 30 ₹93,750 | 50 ₹1.6 L | 20 ₹62,500 |
| 4.00 | M/L for Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. | 283 | Cum | 110 ₹31,130 | 50 ₹14,150 | 30 ₹8,490 |
| 5.00 | M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. | 279 | Cum | 80 ₹22,320 | 50 ₹13,950 | 30 ₹8,370 |
| 6.00 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991)
(a) Excavation and earth work for drilling hole for electrode in any type of Soil.
(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.
(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed
(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.
(e) Requisite quantity of common salt and charcoal.
(f) Testing of earthing. | 15 | Each | 4,000 ₹60,000 | 3,250 ₹48,750 | 4,000 ₹60,000 |
| 7.00 | M&L for earthing complete with galvanised steel earth plate electrode 600X600X6mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below the ground level with top edge of earth plate not less than 1.5 mtr below normal ground level) connected to galvanised earth wire 4mm dia as earthing lead by means of bolts, nuts, chuck nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR-2009 (Part-I) including charcoal dust common salt, 20mm bore GI medium grade watering pipe funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth lead including PCC pit 1:2:4 type B-1 using 20mm graded stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm steel bars 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engr in charge and testing for required value complete. Note: Item Ser No 6 & 7 if earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost. | 5 | Each | 5,500 ₹27,500 | 3,500 ₹17,500 | 3,800 ₹19,000 |
| 8.00 | Supply, laying or fixing or passing through GI pipe, HDPE (DWC pipe) commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs including taking out /dismantling of existing cable.
Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
(a) 10 Sqmm 2 core | 500 | RM | 110 ₹55,000 | 130 ₹65,000 | 140 ₹70,000 |
| 8.01 | (b) -Ditto- all item as per 8.00 above but 10 Sqmm 4 core | 800 | RM | 130 ₹1.0 L | 150 ₹1.2 L | 170 ₹1.4 L |
| 8.02 | (c) -Ditto- all item as per 8.00 above but 16 Sqmm 4 core | 700 | RM | 150 ₹1.1 L | 170 ₹1.2 L | 210 ₹1.5 L |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Sept 2025, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR/ MAINT OF LT DISTRIBUTION SYSTEM, APFC, SERVICE CONNECTIONS AND OTHER ALLIED WORKS IN AREA-I AND II, DG SETS, AMF PANELS, CONTROL CABLES AND ALLIED WORKS AT VARIOUS LOCATIONS AND REPAIR/MAINT TO FIRE ALARM SYSTEM AND MISC WORK AT AFS JAISALMER
2025_MES_720858_2
8339/GE/E8
Open Tender
Miscellaneous Works
270 days
GE (AF) Jaisalmer
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹90,000
Yes
9 Feb 2026
1 Sept 2025
25 Sept 2025
1 Sept 2025
23 Sept 2025
9 Sept 2025
Amount
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site.
M&L for tibba Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
M& L for 40 to 50 mm thick rough dressed Jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cableall as specified and directed.
M/L for Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
M&L for earthing complete with galvanised steel earth plate electrode 600X600X6mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below the ground level with top edge of earth plate not less than 1.5 mtr below normal ground level) connected to galvanised earth wire 4mm dia as earthing lead by means of bolts, nuts, chuck nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR-2009 (Part-I) including charcoal dust common salt, 20mm bore GI medium grade watering pipe funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth lead including PCC pit 1:2:4 type B-1 using 20mm graded stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm steel bars 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engr in charge and testing for required value complete. Note: Item Ser No 6 & 7 if earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.
Supply, laying or fixing or passing through GI pipe, HDPE (DWC pipe) commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs including taking out /dismantling of existing cable. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:- (a) 10 Sqmm 2 core
(b) -Ditto- all item as per 8.00 above but 10 Sqmm 4 core
(c) -Ditto- all item as per 8.00 above but 16 Sqmm 4 core
(c) -Ditto- all item as per 8.00 above but 25 Sqmm 4 core
(d) -Ditto- all item as per 8.00 above but 35 Sqmm 3.5 core
M&L for GI Tubes, of following size, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed. (a) 40 mm bore
(b) -Ditto- all item as per 9.00 above but 50 mm bore
Taking out existing PCC/steel tubular LT electric poles of any length including breaking of cement concrete, necessary excavation and earth work, dismantling cross arms, M.S. clamps, insulators etc and carefully taking down existing over head conductors.
Dismantling of old unservicable bus bar chamber and Design, supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. (a) The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth).
Supply and erecting steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410SP 31 of 9 mtr long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emebeded portion shall be painted with two coat of black bituminous paint all as specified in IS with following specifications:- (i) Excavation in trenches in any types of soil ,returning filling in & well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (ii PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation bedding of size 600x600mm, 200mm base all as specified and directed . (iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level of size 600x600mm for casing of pole upto planting depth. (iv) PCC (1:2:4) type B-2 using 20mm graded stone aggregate as in coping including necessary form work above GL level. (v) Writing pole No with yellow shade on black base using synthetic enamel paint having height of words exc 5 cm as directed by Engr-in-charge.
Supply and fix junction box made out of Fiber reinforced plastic with IP 55/IP 65 protection of size not less 200 x 140 x 95 mm (in side dimensions) , having 5 way terminals mounted on din rail for termination of cable with necessary nuts and bolts , including -02 Nos cable gland , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps, in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type all as directed.
Supply and fix junction box made out of fiber reinforced plastic with IP 55/IP 65 protection of in side size not less 350 x 250 x 140 mm (In side dimensions) , having 5 way terminals suitable for 70 to 95 sqmm 3.5 core cable, mounted on din rail for termination of cable with necessary nuts and bolts , including -02 Nos cable gland , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps, in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type all as directed.
M&L for cutting of black top cover of existing road upto 0.6 mtr depth and upto 45cm wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 upto 3-cm from top of the road surface complete all as specified and directed by Engr - in-charge
S&F the straight through joint LT from 25 sqmm 3.5/4 core upto and including 95 sqmm 3.5 core with jointing all as required and directed at site
S&F the straight through joint LT cable 120 sqmm 3.5 core to 300 sqmm 3.5 core with jointing all as required and directed at site
Supply, fixing and connecting elastomer insulated, flat,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 complete all as specified and directed
Preperation of surface of RCC LT/HT poles and painting with one coat synthetic enamel paint upto 1.5m height in blue and white colour alternate strips each of 30cm wide all as specified and directed by EIC
Material and labour for painting to steel tubular pole/Rail Pole, swan neck pole of HT/ LT over head line and all MS clamps, cross arm work on poles with one coat of superior aluminium paint including necessary preparation of surfaces and painting of alternate strip with white and blue for LT and HT poles, synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above and including PCC benching/coping area complete all as specified and directed by Engr in charge
Dismantling/ taking down of existing street light switching system and Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw Three phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed by the Engr-in-charge. Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclouser - Sintax or equivalent
Scrubbing of existing paints of existing LT panel board where rusted, LT feeder Pillar boxes, LT bus bar chamber paints of any specification and removing old paints and preparation of surfaces for painting complete and M&L for painting of LT Panels, LT Feeder pillar boxes, LT bus bar chambers internaly and externaly with one coat of superior quality smoke grey paint to achieve fine finishing complete all as specified and directed by Engr - in charge at site.
Routine and periodical cleaning the inside area of 11 KV Sub Stations including cutting and removal/uprouting of unwanted grass/bushes, small trees near all around sub station and pump houses complex complete including surface dressing and leveling by surface excavation wherever as required or as directed.
Taking down of old unserviceable LT cables of size 25sqmm 4 core to 300 sqmm 3.5 core and kept in safe custody for schedule of credit/ relaying complete all as specified and directed
M&L for Relaying of LT cables after, jointing or necessary repair work and testing XLPE insulated PVC outer seathed and PVC inner sheath, galvanised steel strips armoured, and reconnecting the cable from over head line and panel suitable for rated voltage of 1100 Volts grade 25 sqmm to 300 sqmm 4/3.5 Core and laid in treches/ducts/pipe or under road/ on wall/pole all as required and directed at site. Note: excavation and earth work joints will be measured and paid seprately
Supply and fixing in repair energy efficient LED street light fittings of capacity not less than 70 Watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection , individuals LED's should have lenses for better throw across &along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector inbuilt in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections all as directed.
Supply and fixing in replacement , street/security light bracket made out of 40 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as direct ,02 nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete.(Rates quoted by the contractor shall deemed to include for nut and bolts).
M&L for maintenance and servicing of DG Set of capacity 7.5 KVA to 75 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing rubber hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed by Engineer-in-Charge.
M&L for maintenance and servicing of DG Set of capacity 80 KVA to 160 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as directed.
M&L for maintenance and servicing of DG Set of capacity 200 KVA to 250 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as directed.
M&L for maintenance and servicing of DG Set of capacity 320 KVA to 500 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as directed.
M&L for maintenance and servicing of DG Set of capacity 750 KVA to 1010 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as directed. Supply in repair the following items from 7.5 KVA to 1010 KVA
Supply in repair the following items from 7.5 KVA to 1010 KVA (a) Control Safety(Water),
(b) -Ditto- all item as per 35.00 above but Control Safety (Lub Oil) ,
(c) -Ditto- all item as per 35.00 above but Gauge Water Temp.(54'),
(d) -Ditto- all item as per 35.00 above but Gauge Low Temp.(96'),
(e) -Ditto- all item as per 35.00 above but Gauge Lub Oil Pressure,
(f) -Ditto- all item as per 35.00 above but Techohourmeter,
Supply and fix in repalacement of battery,12 V 180 AH, 25 plates including testing for its proper functioning as specified and directed by Engr-in-Charge. Make Exide/Amron. Note :- Battery shall be original make accepted No substitute of battery.
Supply and fix in repalacement of battery,12 V 150 AH, 25 plates including testing for its proper functioning as specified and directed by Engr-in-Charge. Make Exide/Amron. Note :- Battery shall be original make accepted No substitute of battery.
Supply and fix in repalacement of battery,12 V 80 AH, 25 plates including testing for its proper functioning as specified and directed by Engr-in-Charge. Make Exide/Amron. Note :- Battery shall be original make accepted No substitute of battery.
Supply and filling in sump / topping up engine oil, multi grade 20w / 40 in engine or relpacement of engine oil Make :- Indian oil / Hindusthan petrolium / Castrol / Pried /Servo complete all as specified and directed by Engineer-in-Charge.
S& F Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 0.3 mtr long
S& F Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 1.50mtr long
Supply and fix in repalcement of AVR card suitable for 7.5 KVA to 75 KVA DG Set as per existing.
Supply and fix in repacement of AVR card suitable for 83 KVA to 160 KVA DG Set as per existing.
Supply and fix in repalcement of AVR card suitable for 200 KVA to 320 DG Set as per existing.
S&F Premixed Coolent(35 Ltr),container
S&F distilled water best quality suitable for lead acid battery, complete all as specified and directed by Engineer-in-Charge.
S&F controller suitable for 60 KVA to 83 KVA DG set, CPCB -I, slilent type as per existing complete all as specified and directed
S&F controller suitable for 250 KVA to 500 KVA DG set, CPCB -I/CPCB-II, slilent type as per existing complete all as specified and directed
M&L for servicing, calibration and testing of injector assembly including replacement of worn out parts, barrel, plunger, nozzel, dilivery valve, cup injector and commissioning the same of cap 63 KVA to 250 KVA DG set complete all as specified and directed by Engr-in-Charge.
Dismantling of UNSV self starter of capacity 12/24 volts from engine and shifting to civil workshop for repair/overhauling of the self starter by rewinding of one field coil, repair and rewinding of armature and fixing it to the existing place after repairing, complete all as specified and directed by Engr-in-Charge.
Supply and fixing contactor 3 pole 32-55 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
Supply and fixing contactor 3 pole 80-85 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
Supply and fixing contactor 3 pole 160 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
Supply and fixing contactor 3 pole 250 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
Supply and fixing contactor 3 pole 400 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
Material and labour for taking down gear assembly of EOT cranes, connected induction motor, servicing, greasing of motors etc complete and dismantling gear box assembly taking out gear and other worn out parts, replacement of worn out parts refilling of gear oil, over hauling, oil seal replacement including lathe work as required at site re-assembly, re-fixing the same and testing including repair of EOT cranes installed above the height of 5.0m from working level, thoroughly cleaned of all dirt, grease, scale and rust by shot blasting or chemical cleaning methods, removing old paint from EOT cranes and attachments parts such as double girders, motors, crane rail, Gearbox cabinet, LT panel board and all moving parts. A single coat of primer shall be given to all parts exposed to the weathering effects and two coats of paint as approved by GE for indoor/outdoor cranes shall be given on all primer painted surface. The bright exposed parts of the crane shall be given one coat of rust inhibitor. Interior of all gear boxes shall be painted with one coat of oil resisting paint. Writing the Technical details of respective crane as per existing data available on each cranes with paint as approved by GE, complete all as directed by Engineer-in-Charge. The capacity of Crans with their locations are as under :- Note : (Spare parts shall be measured and paid seprately) (a) Capacity 1 to 3 TON
(b) -Ditto- all item as per 56.00 above but Capacity 5 ton to 10 TON
Supply only Spares/Components after approval and as directed by Engineer-in-Charge for Cranes/Hoists of Capacity 01 TON TO 3 TON :- (a) Magnetic Coil.
(b) -Ditto- all item as per 57.00 above but Over load relay 0.6 to 1 Amps Make- L&T/Siemens.
(c) -Ditto- all item as per 57.00 above but Over TP Contactor 25 Amps,ML 1.5, 110 Volts, Coil Voltage Make – L&T
(d) -Ditto- all item as per 57.00 above but Over Brake Pads.
(e) -Ditto- all item as per 57.00 above but Over Push Button with auxiliary contacts Make – L&T
(f) -Ditto- all item as per 57.00 above but Over Limit Switch with two contacts in oil tight die cast aluminium housing Make – Siemens.
(g) -Ditto- all item as per 57.00 above but Over Drive as per existing
Supply only Spares/Components after approval and as directed by Engineer-in-Charge for Cranes/Hoists of Capacity 5 to 10 TON :- (a) Oil Seal
(b) -Ditto- all item as per 58.00 above but Gasket
(c) -Ditto- all item as per 58.00 above but Brake for CT/LT Coil.
(d) -Ditto- all item as per 58.00 above but Pedant Push Button Make – Siemens/L&T.
(e) -Ditto- all item as per 58.00 above but Pedant Push Button with auxiliary contacts Make – Siemens/L&T.
(f) -Ditto- all item as per 58.00 above but No Volt Coil 1100 volts Make L&T suitable for contactor ML-4. Make- L&T or equivalent.
(g) -Ditto- all item as per 58.00 above but Carbon Brushes.
(h) -Ditto- all item as per 58.00 above but Over Load Relay 42 Amps Make – L&T.
(j) -Ditto- all item as per 58.00 above but Contactor 45 Amps, 110 volts, ML-4 Make – L&T
(k) -Ditto- all item as per 58.00 above but Drive as per existing
Load Testing of HOT cranes/EOT Cranes with full load and 25% over load all as specified in IS No 301 of 1977 and 3177 of 1977 and writing the date of load testing all as directed by the Engineer-in-Charge for the following capacity :- (Note :- Load will be provided by the Department (users of the crane) complete all as directed (a) Capacity 01 TON to 03 TON
(b) -Ditto- all item as per 59.00 above but Capacity 10 TON
M&L for annual maintenance of EOT cranes of capacity 1 to 10 TON installed at Hangers in tech area at a height of 4 to 8 mtrs by opening of brackets of ball bearing, cleaning/removing of old lubricants/ grease using thinner from the moving parts of the cranes, checking of moving parts for its serviceability, cleaning of rail using sand paper and applying of new castrol grease/AP3 grease on all the moving parts/ Ball bearing and refixing of brackets and making the crane fully functional and smooth complete all as specified and directed at site by Engr-in-charge.
M&L for annual maintenance of HOT cranes of capacity 1 to 3 TON installed at Bldgs in tech area at a height of 3 to 6 mtrs by opening of brackets of ball bearing, cleaning/removing of old lubricants/ grease using thinner from the moving parts of the cranes, checking of moving parts for its serviceability, cleaning of rail using sand paper and applying of new castrol grease/AP3 grease on all the moving parts/ Ball bearing and refixing of brackets and making the crane fully functional and smooth complete all as specified and directed at site by Engr-in-charge.
Supply, fixing and connecting conventional optical smoke Detectors Complying with and type certified complete with standard base for conventional detector complete all as specified and directed
Supply, installation, commisioning and testing 02 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved complete all as specified and directed.
Supply, installation, commisioning and testing 04 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved complete all as specified and directed.
Supply, installation, commisioning and testing 12 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved complete all as specified and directed.
Supply, fixing and connecting conventional type manual call point resettable complete all as specified and directed
Supply, fixing, connecting and testing conventional wall sounder complete all as specified and directed
Supply and fix Remote response indicators complete all as specified and directed
Supply, install & testing of analog addressable type self acclimatising multi sensing certified to EN-54 (photo+ heat/smoke) detector with standard mounting base LED Address switch complete as per existing make (SIEMENS) or other make compatible to existing arrangemnet with junction box for mounting on surface/ false ceiling complete with necessary fixing accessories complete all as specified and directed.
Supply, install & testing of analog addressable type Rate of rise cum fixed temperature with standard mounting base LED Address switch complete as per existing make (SIEMENS) or other make compatible to existing arrangemnet with junction box for mounting on surface/ false ceiling/ below false ceing complete with necessary fixing accessories complete all as specified and directed
Supply, install & testing in repairs of addressable multi crieteria detector combining 4 fire signatures (smoke + heat+co+ IR) with standard mounting base LED Address switch complete as per existing make (SIEMENS) or other make compatible to existing arrangemnet with junction box for mounting on surface/ false ceiling/ below false ceing including taking down existing complete with necessary fixing accessories all as specified and directed
Supply, install & testing of analog addressable type Self acclimatising multi sensing (photo+ heat) detector with standard mounting base LED Address switch complete as per existing make (SIEMENS) or other make compatible to existing arrangemnet with junction box for mounting on above false ceiling with response indicator on false ceiling with matching screws complete with junction box complete with necessary fixing accessories including taking down existing complete all as specified and directed
Supply, fixing and connecting intelligent (Addressible) manual call point resettable operating element, in built isloator, Bi colour LED status complete all as specified and directed
S&F in replacement 2x1.5 sq. mm +1x1.0 sq. mm earth wire for circuit/submain wiring alongwith earth wire, FRLS-H, PVC insulated copper conductor, single core cable drawn through existing conduit/casing caping of any type or size in surface/recessed complete as per site requirement and as directed by Engr-in-charge
S&F in replacement 2x2.5 sq. mm +1x1.5 sq. mm earth wire for circuit/submain wiring alongwith earth wire, FRLS-H, PVC insulated copper conductor, single core cable drawn through existing conduit/casing caping of any type or size in surface/recessed complete as per site requirement and as directed by Engr-in-charge
M&L for supply and fixing in repair air termination, single pointed copper rod 12 mm dia and 300 mm long all as specified and as directed
M&L in repair for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw all as specified and directed
M&L in repair copper strip 20x3.0 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
M&L for porceiline insulator suitable for fixing earthing strip to the wall / floor in and including taking down of existing earthing strip and refixing the same after replacement of insulator complete all as specified and as directed
Bhawani Enterprises (BID ID -3426788)
HINGLAZ ENTERPRISES (BID ID -3433667)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid