Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | ₹17.4 L Quoted ₹17.8 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹18.6 L+₹78,831.16 (4.43%)Rejected-Finance | ₹18.6 L+₹78,831.16 (4.43%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹18.8 L+₹98,722.93 (5.55%)Rejected-Finance 58 CHANDRALOK BUILDING MAYO HOSPITAL ROAD NAGPUR 440 018 | NAGPUR | MAHARASHTRA | 440018 | ₹18.8 L+₹98,722.93 (5.55%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹19.2 L+₹1.5 L (8.28%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | ₹19.2 L+₹1.5 L (8.28%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹19.4 L+₹1.6 L (9.18%)Rejected-Finance | ₹19.4 L+₹1.6 L (9.18%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
17 Jul 2023, 6:00 pmClosed
Garrison Engineer
Garrison Engineer, Cantt Area, Kamptee 441001
REPAIR / REPLACEMENT OF U/G CABLE, LED LIGHT FITTINGS AND OTHER MISC E/M WORKS AT CERTAIN UNIT 371 ARE UNDER GE KAMPTEE.
2023_MES_602948_1
8540/E8
Open Tender
Civil Works
Item Rate
180 days
Kamptee
Class D Cate b (i)
5 documents required · 5 mandatory
₹500
Yes
Kamptee
₹58,000
Yes
17 Aug 2023
19 Jun 2023
19 Jul 2023
19 Jun 2023
17 Jul 2023
3 Jul 2023
Amount
Taking down point wiring with aluminum conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator etc, and making good to the disturbed surfaces of walls/ floor etc to match with existing surfaces including white washing/colour washing/ distemper to match with existing wall/floor/ceiling finishes complete all as specified and directed.
Taking down sheet metal enclosure DB, MCB, main switch etc and making good disturbed surfaces to match with existing surfaces complete all as specified and directed.
Taking down sub main wiring of any size/ capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces complete all as specified and directed.
M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed on wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel modular boxes sunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch.(Cable Make : Finolex, L&T, Legrand, Havells, Polycab) (PVC Conduit Make : Polycab, Superplast, Finolex) Note :- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
As per item No 4 above but One ceiling /exhaust fan point controlled by one switch and regulator complete all as specified and directed.
As per item No 4 above but One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
As per item No 4 above but One 3 pin 5 amps socket out let point on independent board complete all as specified and directed.
As per item No 4 above but One bell/buzzer point controlled by one bell push complete all as specified and directed.
All as per item No 4 here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point complete all as specified and directed.
M&L for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of the following sizes :- 2x2.5 Sqmm with earth wire of 1x2.5 Sqmm. (Cable Make : Finolex, L&T, Legrand, Havells, Polycab) (PVC Conduit Make : Polycab, Superplast, Finolex) Note :- Accessories for point/sub main wiring like PVC junction box, bend, Tee, elbow shall be of same make.
As per item No 10 above but 2x4.0 Sqmm with earth wire of 1x4.0 Sqmm complete all as specified and directed.
As per item No 10 above but 2x 6.0 Sqmm with earth wire of 1x6.0 Sqmm complete all as specified and directed.
As per item No 10 above but 4x 6.0 Sqmm with earth wire of 2x6.0 Sqmm complete all as specified and directed.
As per item No 10 above but 4x 10.0 Sqmm with earth wire of 2x10.0 Sqmm complete all as specified and directed.
Supply and fix ceiling rose surface type 2/3 terminal 5 amps complete all as specified and directed. Make : Legrand, Crabtree, V Guard
S&F Bell ding dong, AC 230 volts, single phase complete all as specified and directed.
Supply and fix lamp holder insulated body with back plate for angle/ batten fitting complete all as specified and directed.
Supply and fix Modular switch one way 6A, 1 module complete all as specified and directed. Make : Legrand, Crabtree, V Guard
Supply and fix Modular switch one way 16A, 1 module complete all as specified and directed. Make : Legrand, Crabtree, V Guard
Supply and fix Modular bell push 6A, 1 module complete all as specified and directed. Make : Legrand, Crabtree, V Guard
Supply and fix Modular Socket 6A 2/3 pin combined 2 module complete all as specified and directed. Make : Legrand, Crabtree, V Guard
Supply & Fix Modular Socket 6A/ 16A 2/3 pin combined 2 module complete all as specified and directed. Make : Legrand, Crabtree, V Guard
Supply and fix Modular Fan step regulator,120 watt 2 module complete all as specified and directed. Make : Legrand, Crabtree, V Guard
Taking down carefully 18/20 watt tube light fittings for reuse at site or carrying to the store complete all as specified and directed.
Refixing LED light fitting 18/20 watt 220 V AC decorative type with driver, holder and LED tubelight including connecting up with three core flexible copper conductor cable of suitable size from ceiling roses complete all as specified and directed.
Taking down carefully 10 watt tube light fittings for reuse at site or carrying to the store complete all as specified and directed.
Refixing LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supplying and fixing 18-22 Watt LED Tube light fittings complete with aluminum body including tube rod, driver with not less than 2000 Lumen O/P and I/p rated voltage 240V connecting with 3 core 1 sqmm copper conductor cable complete all as specified and directed. Make : Philips/Havells/Jaquar/Shakti
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make : Philips/Havells/Jaquar/Shakti
M&L for cutting & taking out the existing surface / sunken box / switch plate with switches / sockets and replacing with Modular metal flush box with modular cover plate with frame 3 module. The following items complete all as specified and directed for: Note:- The disturbed surfaces of wall for concealing box wiring shall be made good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate shall be deemed to include the cost of making good. Switches, sockets, regulators etc to be measured and paid separately.
All as per item no 30 but Modular metal flush box with modular cover plate with frame 4 module complete all as specified and directed.
All All as per item no 30 but Modular metal flush box with modular cover plate with frame 6 module complete all as specified and directed.
All as per item no 30 but Modular metal flush box with modular cover plate with frame 8 module complete all as specified and directed.
All as per item no 30 but Modular metal flush box with modular cover plate with frame 12 module complete all as specified and directed.
Supply and fix sheet metal enclosure single pole & neutral for 240 volts 4/6 way with 200 Amp rated bus bar flush /surface mounting double door, complete all as specified and directed. Make-Legrand/ L&T/ Havells/C&S.
Supply and fix sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door. complete all as specified and directed. Make-Legrand/ L&T/ Havells/C&S.
Supply and fix sheet metal enclosure triple pole & neutral for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed. Make-Legrand/ L&T/ Havells/C&S.
Supply and fix sheet metal enclosure vertical triple pole & neutral(VTPN) with MCCB 63 amps for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed. Make-Legrand/ L&T/ Havells/C&S.
Supply and fix MCB single pole 240 volt 6 to 40 amps 10 KA breaking capacity, 'C' series complete all as specified and directed. Make-Legrand/ L&T/ Havells/C&S.
Supply and fix MCB single pole and neutral 240 volt 6 to40 amps 10 KA breaking capacity, 'C' series, complete all as specified and directed. Make-Legrand/ L&T/ Havells/C&S.
Supply and fix MCB triple pole and neutral 415 volt 40 to 60 amps 10 KA complete all as specified and directed. Make-Legrand/ L&T/ Havells/C&S.
Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 TYPE B-1 (c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion.
Disconnect and insulate electric supply wire and taking down carefully ceiling/exhaust/cabin/ wall fans of any make and sweep dismantling blades, check for repairs required complete all as specified and directed. Note : Repairs/ Replacement of spares shall be carried out under appropriate items.
Hanging only ceiling fans of any make and sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed from ceiling rose to fan connector , painting with spray paint and testing Making of MES No as directed and specified Note : The fan shall be fitted with new set of clamps rubber shackle split pins and top and bottom nut bolts etc.
M & L Painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
Fixing only exhaust/cabin/wall fans of make and sweep connecting lug complete with and including provision of copper conductor cord three core PVC insulated and sheathed from ceiling rose to fan connector & testing. Making of MES No as directed and specified. Note : The fan shall be fitted with new set of washers nuts rubber packing etc complete all as specified and directed.
Opening up of fan motor of ceiling/Exhaust/ wall/cabin fans cleaning starter rotor, cleaning of all parts greasing oiling of bush and bearing reassembling and testing for smooth functioning complete all as specified and directed.
M&L for taken down burnt/damaged winding, cleaning stator and rotor including slots etc, rewinding with suitable gauge of super enameled copper insulated wire for ceiling fan 1200 mm sweep complete all as specified and directed.
All as per item No 48 above but ceiling fan 1400 mm sweep complete all as specified and directed.
All as per item No 48 above but exhaust fan 300 mm sweep complete all as specified and directed.
All as per item No 48 above but exhaust fan 450 mm sweep complete all as specified and directed.
All as per item No 48 above but wall fan / cabin fan 400 mm sweep complete all as specified and directed.
Supply and Fix bearing of replacement for Ceiling fan 1200mm sweep complete all as specified and directed.
All as per item No 53 above but Ceiling fan 1400mm sweep complete all as specified and directed.
All as per item No 53 but exhaust fan 300mm sweep complete all as specified and directed.
All as per item No 53 but exhaust fan450mm sweep complete all as specified and directed.
S & F gun metal bush for ceiling fan 1200mm sweep complete all as specified and directed.
S & F gun metal bush for ceiling fan 1400mm sweep complete all as specified and directed.
S & F for replacement of condenser AC 230 Volt 2.5 MFD complete all as specified and directed.
S&F ceiling fan blades 1200mm sweep complete with nuts and bolts as per sample complete all as specified and directed.
M&L for shaft work of ceiling fan of any make and sweep complete including filling metal and lathe machining complete all as specified and directed.
M/L for down rod for ceiling fan of any make and sweep made out of medium grade GI tubing 15mm dia duly painted with two coat of enamel paint and provision of holes for electric wire at top and bottom also arrangement for fitment of ceiling fans complete all as specified and directed.
M/L MS work such as fan hook angle / FI clamp, MS pipe nuts, bolts, washers welding, bending cold or hot drilling holes for bolts in any shape and size etc including two coats of synthetic enamel paint cover a coat of red oxide primer complete all as specified and directed.
Materials and labour for earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases as required 25x4 mm galvanised strip complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables,poles, stay and getting out of excavated material complete all as specified and directed
Excavation in trenches in any type of hard/dense soil/hard standing not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables,poles, stay and getting out of excavated material complete all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed.
Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50mm outer diameter and 38 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified and directed Make:- Dura. Line/Tijaria/REX/Ketron
Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 63 mm outer diameter and 51 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified and directed Make:- Dura. Line/Tijaria/REX/Ketron
Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 120 mm outer diameter and 103 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified and directed Make:- Dura. Line/Tijaria/REX/Ketron
Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed . Note :- laying of cable route is same as old cable route .
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip, electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 95sq mm, 3.5 core including testing after laid and jointed all as specified and as directed Make :- Gloster/ Polycab/Havells
All as per item No. 73 but cable size 50 sq mm 3.5 core all as specified and as directed.
All as per item No.73 but cable size 35 sq mm 3.5 core all as specified and as directed.
All as per item No.73 but cable size 16 sq mm 4 core all as specified and as directed.
All as per item No.73 but cable size 10 sq mm 4 core all as specified and as directed.
Supply and fix Heat shrinkable straight through cable jointing kit for 1100 Volts grade cable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 to 185 Sq mm complete all as specified and directed. Note :- Any Excavation and earth work ,Returning and filling, Removing involved shall be measured and paid seperatelay
All as per item No. 78 but cable size 70 - 120 sq mm cable size complete all as specified and directed.
All as per item No. 78 but cable size25 - 50 sq mm cable size complete all as specified and directed.
Supply and fix in repairs thermoplastic cable entry junction boxes of size 250 x 220 x 135 mm and IP-65 protection level with metric knock out fixed on poles with MS clamps, nuts, bolts and washers including MCB SPN, 5-32 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc., separate (detachable) gland plate, bakelite connector 4 way 20 amp, dust and vermin proof, front door opening with hinges and locking arrangement, complete all as specified and as directed. Make:- Sintex/Hensel or equivalent
Supply and fix bracket for street light fittings made out of 40 mm dia GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 30 x 5 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fitting including taking down old unserviceable bracket of any shape and size complete all as specified and directed.
Supply and fix in repairs LED driver for 45 W LED street light fitting complete all as specified and directed.
M&L for preparing surfaces of electric poles of RCC type of any sizes including MS cross arms, MS clamps, street light brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of primer and two coat of weather proof paint completely and alternate layer of yellow and black synthetic enamelled paint of 150 mm strips at the bottom of pole 1.5 mtr above coping complete all as specified and directed.
M&L for writing pole No. with letters of size 25 mm height on pole/ plate with Black synthetic enamelled paint complete all as specified and directed.
M&L for preparing surfaces of electric poles of any type of height of HT rail/ tubular poles exceeding 7.5 Mtrs upto 9.5 mtrs above ground level including MS cross arms, MS clamps, street light brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint completely, alternate layer of yellow and black paint of 150 mm strip at the bottom of pole 1.5 mtr above coping with synthetic anamel paint complete all as specified and directed.
M&L for preparing surfaces of electric TWO pole Structures of any make and height of pole up to 10 Mtrs above ground level including MS cross arms, AB Switch pipe, DO Fuse assembly,MS clamps, brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint complete all as specified and directed.
M&L for preparing surfaces of electric Four pole Structures of any make and height of pole up to 10 Mtrs above ground level including MS cross arms, AB Switch pipe, DO Fuse assembly,MS clamps, brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint complete all as specified and directed.
S & F off load change over switch 63 A, 4 pole, 415 V,50 Hz with changing lever and all assesories complete with all incoming and outgoing connection of DG Set and main supply complete all as specified and directed.
S & F off load change over switch 100 A, 4 pole, 415 V,50 Hz with changing lever and all assesories complete with all incoming and outgoing connection of DG Set and main supply complete all as specified and directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including nut bolts ,washers etc complete all as specified and directed.
M&L for outdoor type cubical panel board made out of 3.15 mm thick CRCA sheet and made M&L for outdoor type cubical panel board made out of 3.15 mm thick CRCA sheet for outer shelland made ot of 2 mm thick CRCA sheet for inner shell and MS angle frame 50X50X6 mm CPRI approved fabricated double door including CT and PT of suitable rating with internal connection in aluminium strip of suitable rating both side openable suitable for 3 phase 415 V powder coated 90 microns comprising of following (a) TPN 04 nos aluminium busbar in equal size 3 phase and neutral 200 amp rating duly insulated fitted on heat shrinkable insulation and covered with colour sleeve. (b) Incoming MCCB 125 Amp 25 KA 415 V FP adjustable thermal & Fixed Magnetic 100 % - 01 Nos. (c) Outgoing MCCB 63 Amp 25 KA 415 V TP - 01 Nos (d) Outgoing MCCB 63 Amp 25 KA 415 V TP - 01 Nos (Spare) (e) Outgoing MCB FP 32 Amp C Curve 10 KA- 04 Nos. (f) Multifunction meter for measure,current of Amp, Voltage and Frequency. (g) LED Indicator lamp - 01 Set of Three.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 38,118.00]
Vaidehi E Link
M/S. ELECTROPOWER TECHNOLOGIES
Paragon Electrotechnics
Chinmaya Enteprises
H V ELECTRICALS
V R ASSOCIATES
Bidder Name
Paragon Electrotechnics
Chinmaya Enteprises
Vaidehi E Link
V R ASSOCIATES
SV ASSOCIATE
M/S. ELECTROPOWER TECHNOLOGIES
H V ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .