Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹30.8 L+₹3.2 L (11.5%)Rejected-AOC A 23 TRIBUNE COLONY AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-AOC Quoted L2 |
Tender Value
₹39.2 L
EMD Value
₹78,400
Closing Date
16 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF CHANDIGARH
GE AF CHANDIGARH,AIR FORCE STATION,CHANDIGARH-160003
PROVN OF CERTAIN TECH INFRASTRUCTURE FOR NVG LAB AT 126 HF, HUMIDIFIER FOR PMS AND CERTAIN WORKS AT TECH SECTION AT AF STN CHANDIGARH
2022_MES_569179_2
GE(AF)/CHD/T-54/2022-23
Open Tender
Miscellaneous Works
Works
183 days
CHANDIGARH
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE AF CHANDIGARH
₹78,400
Yes
31 Mar 2023
26 Jan 2023
23 Feb 2023
26 Jan 2023
16 Feb 2023
2 Feb 2023
26 Jan 2023 - 30 Jan 2023
Amount
BOQ UPLOADED ON 26 JAN 2023
M&L for cutting holes exc. half brick but n. exc. one brick in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required and removal of rubbish outside MoD land complete all as specified and directed.
S&F 2nd class hard wood plain framed, panelled shutter 35mm thick (two panel) with lock rail and panel inserts of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces; the size of rails and stiles as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete as specified and directed.
S&F door closer hydraulically regulated, aluminium die cast body designation No. 3 universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg complete as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete as specified and directed.
S&F aluminium mortice lock 4 levers, vertical type, size 100mm all as specified and directed.
S&F aluminium anodised barrel tower bolt 150mm long of extruded section complete all as specified and directed.
S&F 125mm long extruded aluminium alloy handle fabricated type, anodised complete all as specified and directed.
S&F 100mm long alumimum butt hinges, fabricated type complete all as specified and directed.
S&F 300mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolt of extruded section or cast aluminium alloy complete all as specified and directed.
S&F 300mm size mild steel ordinary rat tail rod pattern door spring including roller and roller plate fixed by means of welding complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring,fixed in floor, over length of cove plate 140mm complete all as specified and directed
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe.290.Gde-E-165 complete as specified and directed.
S&F MS framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete as specified and directed.
S&F factory made pressed steel frames for doors with one or more rebates of size 125mm x 60mm made out of 1.25mm thick sheet including necessary fixing lugs, hinges, lock strike plate, etc. including back filling of PCC (1:3:6) type C-0 and treated with one shop coat of red oxide primer complete all as specified and directed.
S&F factory made box type steel window without glazing bars with pintal hinges & 2 Nos 150mm mild steel tower bolt to each shutter, steel handle including flat iron 12mm x 3mm for securing wire mesh, dovetailed or welded, hold fast work and treated with one shop coat of red oxide primer complete all as specified .
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size including filling up the gaps at junctions i.e. at top, bottom and sides with EPDM rubber/ neoprene gasket etc.; aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, CP brass/ stainless steel screws complete all as specified and directed.
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size including filling up the gaps at junctions i.e. at top, bottom and sides with EPDM rubber/ neoprene gasket etc.; aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, CP brass/ stainless steel screws complete as specified and directed.
S&F anodised aluminium window and ventilator shutters; side hung type without sash bars using aluminium sections weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.), suitable handle (1 No.) complete as specified and directed.
S&F steel rolling shutter push pull or manual type fabricated out of 1.25mm thick sheet without ball bearing including top cover, anchoring rod, hasp and staple and one coat of primer and erected in position as indicated complete as specified and directed.
S&F 12mm thick veneered particle board, interior grade, solid core, medium density general purposes type with commercial face veneers type 'BB' complete all as specified and directed.
Taking down cement plaster on brick walls and concrete surfaces and the like including racking out joints, hacking for key, scrubbing down with water etc. including removal of rubbish outside MoD land complete as specified and directed.
M&L 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub-base complete all as specified and directed.
S&F first quality glazed coloured ceramic tiles of size 450mm x 300mm x 7mm thick fixed in pattern to wall (combination of dark & light colour with border) as in skirting, dado, set and jointed in neat cement slurry over and including 10mm thick rendering of cement mortar (1:3) and pointing in white cement with pigment to match the shade of tiles complete as specified and directed.
M&L non-skid coloured ceramic tiles 7mm to 8mm thick (square/ rectangular); area of each tile exc. 0.11sqm but n. exc. 0.18sqm as in floors etc. set & jointed in neat grey cement slurry @ 3Kg/ Sqm and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L non-skid coloured ceramic tiles 8mm thick (square/ rectangular); area of each tile exc. 0.18sqm but n. exc. 0.38sqm as in floors etc. set & jointed in neat grey cement slurry @ 3Kg/Sqm and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
S&F 5.5mm thick sheet glass ordinary quality in squares not exceeding 0.5Sqm in each pane complete all as specified and directed.
M&L for complete removal of old treatment from walls and applying two coats of oil bond distemper over and inclding 1mm thick wall care putty complete all as specified and directed.
M&L for preparation of old treated surface of ceiling and applying two coats of oil bond distemper complete all as specified and directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete as specified and directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm in width or girth and applying two coat of synthetic enamel paint complete as specified and directed.
S&F GI tubing 80mm dia medium grade with all fittings fixed to walls and ceiling or laid in floor complete as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removal of rubbish outside MoD land complete as specified and directed.
Excavation in trenches in soft/ loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation of pole, laying of cable etc. and getting out complete all as specified and directed.
Returning and filling in excavated soil including spreading, levelling, watering and well ramming in layers; each layer not exceeding 25mm thick in soft/ loose soil complete all as specified and directed
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5mtrs above the starting point complete all as specified and directed.
M&L for sand cushioning to cables with a layer of sand 8cm deep before laying the cable and 15cm depth after laying & stretching of cable) complete all as specified. Note: Punned thickness overall 18cm shall be measured & paid.
Supply and laying old size sub class ‘B’ bricks as in protection of cable laid dry flat perpendicular to direction of cable abutting each other complete all specified and directed.
Supply, laying, jointing and testing LT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 2 core complete as specified and directed.
Supply and fixing 2 TR hi wall split units indoor/ outdoor complete including making hole for passing copper pipes and drain pipe with and including provision of copper pipe from indoor unit to outdoor unit copper wounded compressor of suitable size including stand for outdoor unit and extra copper pipe as per site requirement with insulation on pipe with cordless remote control unit and with inbult air ionizer and plasma filter for better indoor air quality, BEE 5 star rated including commissioning and testing complete all as specified and directed. Make: Blue star/ Hitachi/ Daikin
S&F voltage stabilizer 5KVA automatic operation, single phase, naturally air cooled indoor type & designed for input variation between 150V to 280V with output voltage stabilized at 230V with accuracy of ± 2.5% complete all as specified and directed. Make: V-Guard Model No AULTEN 5 KVA 4000 W 150 V-280 V Heavy duty or equivalent from AE/ APLAB/ ANDREW YULE.
M&L for submain wiring complete with two runs of 4.0 Sqmm single core, multi-stranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 2.5 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit any type complete all as specified. Note: Two runs of 4.0sqmm multi-stranded cable and one run of 2.5sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
S&F sheet metal enclosure single pole and neutral with a two pin & earth plug and socket etc. complete with on single pole MCB 32 Amps, 'B' curve, 240 volts 10 KA complete all as specified and directed.
S&F sheet metal enclosure for MCBs factory made single door, SPN 240 volts 8 ways with 200 Amp bus bar with IP43 protection complete all as specified and directed.
S&F MCB SP 240 volts 6 to 32 Amps curve 'B' complete all as specified and directed.
S&F MCB SPN 240 volts 40 Amps curve 'B' complete all as specified and directed.
Supply and install inverter UPS for 30 minute back up single phase AC input 160 to 260V and output 230 ± 1% of capacity 3 KVA capacity 230 V AC supply complete including 2 Nos tubular battery of 180 AH, 24 volts including testing and commissioning with two years of warranty in inverter and tubular battery complete all as specified and directed.
S&F air termination, single pointed copper rod 12mm dia and 300mm long complete all as specified and directed.
S&F aluminium strip 25mm x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
S&F test point terminal block made of gun metal or phosphorous bronze size 75mm x 75mm x 25mm drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head nuts complete all as specified and directed.
M&L for earthing complete with galvanize steel earth plate electrode 60cms x 60cms x 6.00mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of the earth plate not less than 1.5 metre below normal ground level, earth plate surrounded by 15cm thick and packed with alternate layers of charcoal dust and common salt using galvanised iron strip 25mm x 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board including water pipe 20mm bore GI light grade with funnel and wire mesh including necessary excavation and earth work PCC chamber in cement concrete (1:3:6) type C-2 and RCC pit cover all as shown in electrical plate No. 5 of MES Sch Part-1 (2009) complete all as specified.
Supply, install, testing and commissioning cubical type of LT panel outdoor type made out of 18 gauge CRCA sheet with 4 No. 100 Amp rated aluminium bus bar of suitable size with colour code tape the overall size of panel shall be as per manufacturer’s instruction with and including provision of the following fitting, fixture and accessories:- (a) MCCB 63Amp, 25KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting- 01 No. (b) MCB ‘C’ curve type 32 Amp TPN- 02 No. (c) Main panel on/ off indicator- 01 No. (d) Fault indicating lamp -01 No. (e) Indicating lamp ‘R’, ‘Y’, ‘B’ one set of three- 01 Set.
Supply, installation, testing and commissioning humidifier floor mounted type of capacity 12 KW made from 2mm thick stainless steel sheet with seam welding construction including inlet/ outlet/ drain and overflow nozzle with open-able type top cover with SS bolts duly insulated with 25 gauge thick aluminum sheet, tank with two separate chambers for water storage and housing of healing element, low level switch to cut the power supply when water level drops at the tank below certain level, extra heater of 0.5 KW with thermostat to maintain temp at 750 C inside the tank, control panel with low level cut out, float valve with SS ball, thermostat for additional heater range 500C to 750C, master thermostat for load range 50⁰C to 120⁰C, sight glass provided to check water, overflow valve, digital display, humidity control and flame proof terminal box for 3 phase complete all as specified and directed. Make: Rapid Cool or equivalent as approved by GE
M/s AVINASH CHANDER GUPTA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .