SE, EDC, BDN
BUDAUN
96/EDCB/2023-24
2024_MVVNL_921716_5
96/EDCB/2023-24
Open Tender
Electrical Works
Item Rate
90 days
BUDAUN
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹3,540
A/c No. 1243002100806171, IFSC Code - PUNB0124300
₹27,000
9 Jan 2025
3 Oct 2024
15 Oct 2024
3 Oct 2024
14 Oct 2024
3 Oct 2024
3 Oct 2024 - 14 Oct 2024
Amount
The work of safe carriage of the following material from store center Nawada to work site under the jurisdiction of EDD-I, Budaun Approx. distance upto 0-20 Km. Including safe loading and unloading.
11 KV 3X185 Sqmm XLPE Cable
11 KV 3X185 Sqmm XLPE Cable Box Indoor Jointing Kit
11 KV 3X185 Sqmm XLPE Cable Box Outdoor
11 KV 3X70 Sqmm XLPE Cable
11 KV 3X70 Sqmm XLPE Cable Jointing Kit Outdoor
11 KV 3X70 Sqmm XLPE Cable Jointing Kit ST. TH. Outdoor
11 KV VCB O/G
11 KV VCB I/C
11 KV Fuse Set
33 KV Lightening Arrestor
33 KV VCB O/D
33 KV Control Pannel for Double Transformer
33 KV C.T., 400/200/1-1-1 Amp.
33 KV Line Isolator
PCC Pole Support 9 Mtr. Long
ST Pole Support 11 Mtr. Long
11 KV Disc Insulator Composite 45 KN (T&C Type)
11 KV Pin Insulator Composite
11 KV X-Arm V Type
ACSR Rabbit Conductor
L.T. XLPE Armoured Cable Al 3.5x240 Sqmm
L.T. XLPE Armoured Cable Al 3.5x400 Sqmm
Stay Complete
Earthing Complete
G.I. Wire 6 SWG
G.I. Wire 10 SWG
BATTARY CHARGER 24VOLT
BATTARY Set 24VOLT
Dismantling of following old & damaged equipment’s as per norms complete in all respect
11 KV VCB O/G
11 KV VCB I/C
33 KV Lightening Arrestor
33 KV VCB O/D
33 KV Control Pannel for Double Transformer
33 KV C.T., 400/200/1-1-1 Amp.
33 KV Line Isolator
Erection/Installation of following 11 KV Panel (VCB) in control room and cable joint of the panel to pole including earthing, grouting of Anchor bolt of Panel and making/repairing of pocket for cable to insert in panel from trench and fixing, taping of bus bar with wiring for PT. AC, DC connection including providing of AC & DC Supply.
11 KV VCB I/C
11 KV VCB O/G
Mounting and installation including mechanical/electrical fixing and adjusting of the following equipment on their respective structures including proper adjustment as per RESSPO Norms.
11 KV Fuse Set
33 KV Lightening Arrestor
33 KV VCB O/D
33 KV Control Pannel for Double Transformer
33 KV C.T., 400/200/1-1-1 Amp.
33 KV Line Isolator
BATTARY CHARGER 24VOLT
BATTARY Set 24VOLT
Laying of control cable from 33 KV Panel to VCB 2x2.5 Sqmm Aramourd cable under ground in trench making proper complete in all respect as per RESSPO Norms.
Laying of control cable from 33 KV Panel to VCB 4x2.5 Sqmm Aramourd cable under ground in trench making proper complete in all respect as per RESSPO Norms.
Erection of Single PCC pole 9 Mtr. Long in H.T/L.T lines including fitting of all accessories as per RESSPO Norms (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms).
Erection of Single ST pole 11 Mtr. Long in H.T/L.T lines including fitting of all accessories as per RESSPO Norms (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms).
Grouting of PCC Pole 9 Mtr. Long & ST pole 11 Mtr. Long with 1:4:8 mixture in size (450x450x1500mm.) including cost of cement/C.C. & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor).
Erection/Fixing of stay set with stay wire and clamp as per RESSPO norms including binding. climbing, clamping, tightening and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and C.C. and sand etc. as per RESSPO norms. All the grouting material shall be provided by the contractor .
The work of driving the earthing electrode and making connections with GI wire.
Dismantling of following old & damaged Line as per norms complete in all respect
ACSR Weasel Conductor
11 KV 3X70 Sqmm XLPE Cable Old & Used
Laying, Stringing, Sagging & Jumpring of Following Conductor complete in all respect as per RESSPO Norms.
ACSR Rabbit Conductor
11 KV 3X70 Sqmm XLPE Cable
Fixing of 11 KV 3x70 Sq.mm XLPE Cable outdoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
Fixing of 11 KV 3x70 Sq.mm XLPE Cable jointing kits ST. TH. Outdoor after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
Underground Laying of 11 KV 3x185 sq.mm XLPE cable in double circuit complete in all respect along with road restoration.
Fixing of 11 KV 3x185 Sq.mm XLPE Cable Indoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
Fixing of 11 KV 3x185 Sq.mm XLPE Cable outdoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
Underground Laying of L.T. XLPE Armoured Cable Al 3.5x240 Sqmm complete in all respect along with road restoration.
Underground Laying of L.T. XLPE Armoured Cable Al 3.5x400 Sqmm complete in all respect along with road restoration.
Fixing of danger board on each location and G.I. barbed wire including proper clamping as per RESSPO Norms. (Danger Board shall be provided by the contractor as per RESSPO Norms) complete in all respect.
Erraction/Fixing of Tailess Unit (600 A) (Tailess Unit shall be provided by the contractor as per RESSPO Norms). complete in all respect as per
Guarding of HT/LT/Telephone Line/Road/River crossing etc. and making net with difference of 1.00 Mtr. Completely including fixing of all channel/angle etc. with proper locking at each support. All type nut & bolt shall be provided by the contractor.
Fixing & Fabrication of Fuse Set Structure with grouting including cost of cement/CC. & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor).
Pipe Earthing of VCB (By boring of 4 inch diameter 20 m deep, 40 mm diameter A Class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5m length is inserted at the bottom, Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work contractor will provide all material, manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE).
The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom).
Holding Clamp for Guarding Angle
11 KV F Clamp with Nut & Bolt
X-Arm Holding Clamp with Nut & Bolt
Danger Board
Al. Lugs for 240 KV Sqmm Cable
Al. Lugs for 400 KV Sqmm Cable
11 KV Guarding Angle
LT Tailess Unit (600A)
Control Cable from 33 KV Panel to VCB 2x2.5 Sqmm Aramourd
Control Cable from 33 KV Panel to VCB 4x2.5 Sqmm Aramourd
Fuse Set Structure with Concrete
Safe back carriage of Following item (if any) from work site to Store Center, Nawada, Budaun approx distance upto 0-20 Km including loading & unloading.
33 KV VCB O/D Damage
11 KV VCB O/D Damage
33 KV Line Isolator Scrap
M/S HINA ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .