Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 CrAccepted-AOC | ₹13.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹15.0 CrRejected-AOC VILL DHOLIYA PO PANDEYPURA BLOCK HUNTERGANJ DIST CHATRA | CHATRA | JHARKHAND | 825103 | ₹15.0 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹16.2 CrRejected-AOC | ₹16.2 Cr | L3 | Rejected-AOC L3 |
| 4 | L4₹17.5 CrRejected-AOC GILANPARA DUMKA | ₹17.5 Cr | L4 | Rejected-AOC L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical 4.7 |
Tender Value
₹16.8 Cr
EMD Value
₹16.8 L
Closing Date
7 Feb 2022, 5:00 pmClosed
CHIEF ENGINEER, JSRRDA
JSRRDA, 3RD FLOOR, FFP BUILDING, DHURWA, RANCHI, JHARKHAND
Construction and Maintenance of Roads under PMGSY-III
2022_CEJHR_115597_55
NIT-06-JH-P3(Batch-I)
Open Tender
Civil Works - Roads
365 days
HAZARIBAGH
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹16.8 L
12 Sept 2022
20 Jan 2022
8 Feb 2022
20 Jan 2022
7 Feb 2022
20 Jan 2022
Amount
Setting out etc all complete job as per specification and directioni of E/I
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical specification Clause 201.
Scarifying existing granular surface to a depth of 50 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. SOR 3.2
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. ( Dismantling of cement concrete)
Dismantling of Rubble masonary/Brick masonary in cement mortar Vide SOR 2.6/2.7 (B)
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202.
Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification
Compacting original ground supporting subgrade: Loosening, of the ground upto level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of of Tables 300.1 and 300.2 for subgrade construction as per Technical Spe
Construction of embankment with approved material obtained from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 Qty (Free Lead)
Construction of embankment with approved material obtained from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 (Lead upto 250m))
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. GRADING-II
Wet Mix Macadam (WMM) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. SOR NO4.9
Providing and applying Primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification SOR NO. 5.1
Providing and applying Tack coat with Bitumen emulsion (RS-1) using emulsion pressure distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared non-bituminous surfaces (cement concrete pavement) cleaned with Hydraulic broom as per Technical Specification Clause 503. SOR NO. 5.2
Providing and laying bituminous macadam (BM) with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site upto a lead of 1000 m laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504.
Semi Dense Bituminous Concrete (SDBC)Providing and laying semi dense bituminous Concrete with 100-120 TPH batch type hot mixplant producing an average output of 75 tonnesper hour using crushed aggregate of specified grading, premixed with bituminous binder @ 4.5 to 5 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tendem rollers to achieve the desired compaction as per MORTH specification clause No. 508 complete as per Technical Specification. SOR NO. B. 3.1
Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days,clause1501 of MoRD SOR NO. 6.4
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing
Direction and Place Identification Signs upto 0.9 sqm Size Board. Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminum sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing SOR NO. 10.3
Providing and fixing of retro- reflectorised cautionary, mandatory and Traffic Sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminum sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing SOR NO 10.2
Reinforced cement concrete M-15 grade 5th Kilometer stone (Precast)/Local stone of stadard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703.
Reinforced cement concrete M-15 grade Ordinary Kilometer Stone (Precast) stone/Local stone of stadard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703.
Reinforced cement concrete M-15 grade 200m stone (Precast) stone/Local stone of stadard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703.
Boundary pillar: Reinforced cement concrete M-15 grade boundary pillars/Local stone of standard design as per IRC:25 fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 704. (Boundary pillar/ FI Post)
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.
Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/ road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surface as per drawing and Technical Specification Clause 1701 SOR NO. 10.5
Road Safety Devices and Signs in Road No of curves Left - & Right
Object marker in front of structure such as Culverts, bridges etc all complete job as per specification.
Painting of hazardous objects like electric pole etc all complete job as per specification.
Painting of hazardous objects trees etc all complete job as per specification.
Left Turn curve (90 cm equilateral triangle)
Right Turn curve (90 cm equilateral triangle)
Zebra Crossing
Stop Sign board Board (60 cm circular)
Sign board
Narrow Bridge( 80 mm x 60 mm rectangular) Sign board
Speed limit Board (Annexure attached)
Temple/Mosqe and other religious place
School Sign board
Speed Breaker
Village Sign Board
JUNCTION Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m
Construction of granular sub base by providing coarse graded material @ 1.28 m3 / m3 , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause401. As per MOSRT&H specification401 (4th revision) and direction of E/I
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
Providing and applying primer coat with bitumen emulsion on prepared surface of granular base including clearing of the road surface and spraying primer @0.60 kg/sqm using mechanical means . As per MOSRT&H specification 502 (4th revision ) & as per direction of E/I.
Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor @0.20 kg/sqm on the prepared bituminous surface cleaned with mechanical broom. As per MOSRT&H specification 502 (4th revision ) & as per direction of E/I.
Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site upto a lead of 1000 m laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504.
Providing and laying semi dense bituminous Concrete with 100-120 TPH batch type hot mixplant producing an average output of 75 tonnesper hour using crushed aggregate of specified grading, premixed with bituminous binder @ 4.5 to 5 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tendem rollers to achieve the desired compaction as per MORTH specification clause No. 508 complete as per Technical Specification.
Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
DRAIN Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (11.1)
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 (SOR 14.5)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (SOR 12.5) PCC 15 (1:2:4)
Stone masonry in cement mortar for foundation & Plinth complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 (SOR 11.6)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (SOR 12.5) PCC 15 (1:2:4)
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204.
Providing and laying reinforced cement concrete in superstructure as per drawing Deck Slab (M25) (50% of Drain covered by Slab).
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 (SOR 13.3) (50% of drain covered by Slab)
Protection Work Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 including setting out,construction of shorting and bracing, removal of stumps and other deleterious matte, dressing of sides and bottom and backfilling with approved material. SOR NO, 11.1
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 PCC Grade M-15 SOR NO. 12.5
Stone masonry in cement mortar (1:4) random rubble masonry for foundation complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 SOR NO.11.6
Stone masonry in cement mortar (1:4) random rubble masonry for superstructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 SOR NO. 13.17
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 PCC Grade M-15 SOR NO. 12.5
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 SOR 12.9
Pointing with cement mortar (1:3) :-- Pointing with cement mortar (1:3) on Stone Masonry work as per drawing and technical specification Clauses 613.3 and 1204
HUME PIPE CULVERT 1nx1m dia Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Providing M10 (PCC 1:3:6) as levelling course in foundation :-- Providing PCC M 10 (1:3:6) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone Masonary in C.M.(1:4) in Foundation :-- Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Providing and laying 1000 mm Dia RCC pipe NP-3 for culverts on first class bedding of PCC M10 (1:3:6) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works,backfilling concrete and masonary works in head
Pointing with cement mortar (1:4 ) on brick work in sub-structure as per Technical Specifications
Parapet Stone masonry in cement mortar (1:4) random rubble masonry for foundation complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 SOR NO.11.6
Providing concrete for plain/reinforced concrete in open foundation complete as per drawings and technical specification clause 802, 803, 1201 & 1203. (11.4 (ii) PCC Grade M-15
Plastering with cement mortar (1:4), 15 mm thick on stonework in substructure as per technical specification Clauses 613.4 & 1204 SOR NO. 12.3
R C C Culvert 1nx2mx1.4m Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108.
Providing PCC M 15 (1:2.5:5) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in substructure and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Providing Bitumen painting over top surface of Abutment cap & inner vertical surface of Dirt Wall including Heating the bitumen & cost of painting brush etc. all complete.
RCC M25 in Deck Slab :-- Providing and laying reinforced cement concrete in superstructure (Deck slab M25) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight
Stone masonry work in cement mortar 1:4 in parapet excluding pointing and plastering as per drawing and technical specifications Clauses 600, 900 and 1208.4
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (PCC-1:2:4)
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
Providing 1.5 mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I
Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and Specification.
Back Fillling in foundation trenches as per drawing and technical specification Clause
RCC Culvert 1nx2mx2m Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108.
Providing PCC M 15 (1:2.5:5) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in substructure and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Providing Bitumen painting over top surface of Abutment cap & inner vertical surface of Dirt Wall including Heating the bitumen & cost of painting brush etc. all complete.
RCC M25 in Deck Slab :-- Providing and laying reinforced cement concrete in superstructure (Deck slab M25) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight
Stone masonry work in cement mortar 1:4 in parapet excluding pointing and plastering as per drawing and technical specifications Clauses 600, 900 and 1208.4
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (PCC-1:2:4)
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
Providing 1.5 mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I
Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and Specification.
Back Fillling in foundation trenches as per drawing and technical specification Clause
RCC Culvert 1nx3mx3m Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108.
Providing PCC M 15 (1:2.5:5) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Stone masonry work in cement mortar (CM 1:4) in substructure and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203
Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Providing Bitumen painting over top surface of Abutment cap & inner vertical surface of Dirt Wall including Heating the bitumen & cost of painting brush etc. all complete.
RCC M25 in Deck Slab :-- Providing and laying reinforced cement concrete in superstructure (Deck slab M25) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight
Stone masonry work in cement mortar 1:4 in parapet excluding pointing and plastering as per drawing and technical specifications Clauses 600, 900 and 1208.4
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (PCC-1:2:4)
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
Providing 1.5 mm cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I
Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and Specification.
Back Fillling in foundation trenches as per drawing and technical specification Clause
MAINTENANCE For 1st Year
For 2nd Year
For 3rd Year
For 4th Year
For 5th Year
Labour Cess @ 1%
Jai Maa Ambe Infra Private Limited
Kamdhenu Awas
niraj kumar agarwal
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid