| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹68.0 L+₹4.5 L (7.06%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹69.5 L+₹6.0 L (9.52%)Rejected-AOC GROUND FLOOR THAKUR COMPLEX BASANTPUR | BASANTPUR | SHIMLA | HIMACHAL PRADESH | 171018 | L3 | Rejected-AOC L3 |
Tender Value
₹47.5 L
EMD Value
₹78,800
Closing Date
4 Jul 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical Division No-1 HPPWD
Executive Engineer Electrical Division No-1 HPPWD Shimla-9
Providing E.I in Girls Hostel Block A Block C Block D and Mess Block B
2020_PWD_38077_1
Electrical Division No.I 500.05 Dated 02.06.2020
Open Tender
Electrical Works
Item Rate
730 days
SHIMLA
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
E.E.Electrical Division No-I Shimla
₹78,800
2 Jun 2021
22 Jun 2020
6 Jul 2020
22 Jun 2020
4 Jul 2020
22 Jun 2020
120 days
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group-C
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Providing & fixing GI modular box 8 module complete with 3 nos 5/6 amp modular socket outlet & 2 nos 5/6 one way module switch complete with coection etc as required complete in all respects .
Providing & fixing IO switch with plate and cat-6 connector with pvc box as required complete in all respects.
Providing and installation of following type of surface mounting slim circular type/Square type LED downlight in white finish with anti glare polycarbonate diffuser and energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. as required. Make: Philips, Syska, GE, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.
LED 22 watt
LED 15 watt
LED 6 watt
Providing and installation of following type of recess/surface mounting slim square type LED panel in white finish with anti glare polycarbonate diffuser and seprated energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including making suitable cut-out in the existing ceiling, connections, testing and commissioning etc. as required. Make: Philips, Syska, GE, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.(30 watt 1x1)
Providing and installation of following type of recess/surface mounting slim square type LED panel in white finish with anti glare polycarbonate diffuser and seprated energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including making suitable cut-out in the existing ceiling, connections, testing and commissioning etc. as required. Make: Philips, Syska, GE, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.(36watt 2'x2')
Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. LED lamp holder (s), complete with all accessories but excluding LED lamp including making connections, testing etc. as required. Bulk head fitting, LED type (Category-A)
Providing and installation of following type of ultra slim decorative LED batten with extruded aluminium heat sink, with anti glare polycarbonate diffuser and energy efficient constant current, integral electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including mounting clips & loop in loop out wire, connections, testing and commissioning etc. as required. Make: Philips, Syska, GE, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.(20 watt)
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Exhaust Fan, Heavy duty, 300 mm sweep
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:-
Ceiling Fan 1200 mm sweep, Category-A
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:-
25 Liter capacity water heater (Cat-A)
50 Liter capacity water heater (Cat-A)
Supplying and fixing 20 Amps, 240 volts, SPN industrial socket outlet, 2-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp SPN-MCB/DP, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.
Supplying, Installation, Testing and Commissioning of Cubical panel floor mounted (on base frame) totally enclosed and extensible type. Degree of IP protection shall be IP-42 unless and otherwise specified. The panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables/bus ducting, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 1.6 MM.CRCA (14/16SWG) Sheet, treated thorough chemical treatment with 8 tank process method for degreasing, Derusting and Phosphating Powder coating shall be 60‐80 microns, in Siemens Gray (RAL‐7032) Shade; 75x40 mm Channel Base Frame. General construction shall employ the principle of compartmentalization and segregation of each circuit. Cable Entry will be at Bottom Suitable for Cable, Lock, Rubber Gasket, hardware etc. The bus bars will be insulated with PVC heat shrinkable sleeves and supported SMC/DMC at suitable intervals so as to withstand dynamic stresses developed in the event of short circuit of 36KA (RMS) and will withstand following standard tests:‐ a) Continuity tests b) No load operation test c) H.T Test (2kV) for one minute d) Insulation resistance test. Make of L&T, Schneider, Siemens, ABB or any equivalent approved by Er-in-Charge.
ACB 630A 4P 50KA MDO Type With O/L, S/C & E/F Protection One No Digital Multifunctional Meter EM6436H 1no Current Transformer 600/5A CL.-1.0, 5VA C.T 3 No. Shorting Link 6 no N.Link 1 no Phase Indication Lamps Led Type Red/ Yellow 2no Phase Indication Lamps Led Type Blue 1 no Indication Lamp LED Type ON/OFF2 no SP MCB 6A 4 no.
Incomer-2 (Power)
MCCB 400A 4P 50KA TMR With O/L & S/C Protection 1 no Spreader Link 400A 4P 1 no RHOM Ext.1 no Phase Indication Lamps Led Type Red/ Yellow 2 no Phase Indication Lamps Led Type Blue 1no SP MCB 6A 3 no
Outgoing
MCCB 100A 4P 36KA TMR With O/L & S/C Protection 6 no, Spreader Link 100A 4P 6 no, RHOM Ext. 6 no, Space for MCCB 100A 4P 36KA TMR With O/L & S/C 2 no, Space for Spreader Link 100A 4P 2 no,Space for RHOM Ext 2 no
Incomer (Light)
Changeover Switch 200A 4P Onload Type 1 no,MCCB 200A 4P 50KA TMR With O/L & S/C Protection 1 no,Spreader Link 200A 4P 1 no,RHOM Ext.1no,Phase Indication Lamps Led Type Red/ Yellow 2 no,Phase Indication Lamps Led Type Blue 1 no,SP MCB 6A 3no
Outgoing
MCCB 100A 4P 36KA TMR With O/L & S/C Protection 6no,Spreader Link 100A 4P 6no,RHOM Ext. 6 no,Space for MCCB 100A 4P 36KA TMR With O/L & S/C protection 2 no,Space for Spreader Link 100A 4P 2 no,Space for RHOM Ext.2 no.
Fabrication/ Painting & Assembly
Fabrication charges of cubical type, Indoor type, Single door, Floor mounted, fixed type, free standing single front,dust proof & compartmentalized Main L.T. Panel 1 nomadeout of M.S. CRC Sheet 14G/16G, Channel 75x40x3MM duly painted with Siemens Grey Powder Coated Paint as per specification & Drawings.
Assembly Charges of 600A 4strip Aluminium Busbar 1 no (Horizontal/ Vertical) & Earth strip throughout the length of Panel (current density of Aluminium Busbar shall be 1mmx1mm=1.0 Amp.) Aluminium shall be Electric Grade E- 91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & black.
Assembly Charges of 400A 4strip Aluminium Busbar 1 no (Horizontal/ Vertical) & Earth strip throughout the length of Panel (current density of Aluminium Busbar shall be 1mmx1mm=1.0 Amp.) Aluminium shall be Electric Grade E- 91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & black.
Assembly Charges of 200A 4strip Aluminium Busbar (Horizontal/ Vertical) & Earth strip throughout the length of Panel (current density of Aluminium Busbar shall be 1mmx1mm=1.0 Amp.) Aluminium shall be Electric Grade E- 91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black.
Assembly Charges of Aluminium solid/ Copper flexible wire interconnection Busbar to MCCB/ACB & MCCB/ACB to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables.will provide all interconnection till back side for incoming/ outgoing terminations as per rating of switchgear.
Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control Wiring) with thimbles printed sleeves, tie & belt etc.
Assembly Charges of Accessories like Gasket, Door locks, Copper Flexible door earth, legend plates etc.
Supplying, Installation, Testing and Commissioning of Cubical Sub-Main Distribution panel floor/wall mounted totally enclosed and extensible type. Degree of IP protection shall be IP-42 unless and otherwise specified. The panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 1.6 MM.CRCA (14/16SWG) Sheet, treated thorough chemical treatment with 8 tank process method for degreasing, Derusting and Phosphating Powder coating shall be 60‐80 microns, in Siemens Gray (RAL‐7032) Shade, 75x40 mm. Channel Base Frame. General construction shall employ the principle of compartmentalization and segregation of each circuit. Cable Entry will be at top & Bottom Suitable for Cable, Lock, Rubber Gasket, hardware etc. The bus bars will be insulated with PVC heat shrinkable sleeves and supported SMC/DMC at suitable intervals so as to withstand dynamic stresses developed in the event of short circuit of 36KA (RMS); shall be C.P.R.I. Tested & shall be suitable to house and include the following Switchgear & accessories: Make: L&T, Schneider, Siemens, ABB, C&S or any equivalent approved by Er-in-Charge.
MCCB 100A 4P 36KA TMR With O/L & S/C Protection 1no,Spreader Link 100A 4P 1no, RHOM Ext 1No, Phase Indication Lamps Led Type Red/ Yellow 2no, Phase Indication Lamps Led Type Blue 1No, Control MCB 6A SP 10KA 3 No.
Fabrication/ Painting & Assembly
1 Fabrication charges of cubical type, Indoor type, Single door, floor mounted/ wall mounted fixed standing single front, dust proof & compartmentalized Sub Distribution Board made out of M.S. CRC Sheet 16G, duly painted with Siemens Grey Powder Coated Paint as per specification & Drawings.
Assembly Charges of 100A 4Strip Copper Busbar (Horizontal/ Vertical) & Earth stud both sides of Panel (current density of Aluminium Busbar shall be 1mmx1mm=1.66 Amp.) copper shall be Electric Grade, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black.
Assembly Charges of Copper solid/ Copper flexible wire interconnection Busbar to MCCB & MCCB to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & inger type insulators of adequate size to support & sustain the weight of cables.
Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control Wiring) with thimbles printed sleeves, tie & belt etc.
Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-8 way
Double door-12 way
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Double pole. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. Cat-A.
63 Amps. Cat-A.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole. Cat-A.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 25 sq. mm (3.5 core)
Armoured cable 35 sq. mm (3.5 core)
Providing and laying of aluminium conductor, PVC insulated and PVC sheathed, unarmoured/XLPE power cable, working voltage 1100 volts grade direct in ground in the same trench, in one tier horizontal formation to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering etc. of required size:-
Unarmoured cable 630 sq. mm (3.5 core)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x10 Sq. mm.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required.
Haminder Pal
Rakesh Kumar
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_56106.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .