Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | ₹4.0 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹4.2 Cr+₹19.6 L (4.91%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹4.2 Cr+₹19.6 L (4.91%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹4.2 Cr+₹23.7 L (5.93%)Rejected-Finance | ₹4.2 Cr+₹23.7 L (5.93%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹4.9 Cr+₹88.2 L (22.1%)Rejected-Finance | ₹4.9 Cr+₹88.2 L (22.1%) | L4 | Rejected-Finance Not lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical Adverse remarks found in ADG P Chennai WLR for QE Mar 2025 |
Tender Value
₹3.9 Cr
EMD Value
₹4.7 L
Closing Date
31 May 2025, 6:00 pmClosed
CHIEF ENGINEER SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
PROVISION OF DEFICIENT MARRIED ACCOMMODATION FOR SERVICE OFFICERS (MAJOR AND ABOVE) POSTED AT RCI HYDERABAD
2025_MES_701520_1
84028
Open Tender
Civil Works
Lump-sum
540 days
RCI Hyderabad
Class A
category a(i)
8 documents required · 8 mandatory
₹2,000
GARRISON ENGINEER I RND RCI HYDERABAD
₹4.7 L
Yes
9 Jul 2025
15 Mar 2025
2 Jun 2025
15 Mar 2025
31 May 2025
17 May 2025
Amount
Schedule 'A' Part-I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6.
Lumpsum price worked out by the contractor for Construction of block of 4 quarters of major and above accommodation alongwith servant quarter and garrages in double storey in RCC framed structure including all fittings and fixtures complete all as specified and shown on drawings.
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND DEVELOPMENT INCLUDING DEMOLITION" as listed in Schedule ‘A’ Part - II representing _________ % ___________________ percent Above / Below the lump sum price of `15,21,141.56 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - III representing __________ % __________________ percent Above / Below the lump sum price of `2,57,802.00 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IV representing ___________ % ______________________ percent Above / Below the lump sum price of ₹20,82,882.52 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for “ROADS / PATH” as listed in Schedule ‘A’ Part - V representing ________ % ____________ percent Above / Below the lump sum price of ₹15,14,226.57 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VI representing _____________ % ____________________ percent Above / Below the lump sum price of ₹2,21,006.32 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part - VII representing _____________ % _____________________ percent Above / Below the lump sum price of `3,17,492.82 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - VIII representing __________ % ___________________ percent Above / Below the lump sum price of `5,00,054.22 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part - IX representing ___________ % ___________________ percent Above / Below the lump sum price of ₹17,84,196.21 inserted by the MES in Schedule ‘A’ Part - IX
This Schedule Part - X is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 38.00.
Schedule 'A' Part-XI This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 12.00 to 37.00.
INTERNAL WATER SUPPLY M&L for angular stop cock with wall flange complete all as specified and directed.
M&L for 2 way bib cock with wall flange complete all as specified and directed.
M&L for wall mixer with provision for overhead shower with 115mm long bend pipe on upper side, connecting legs and wall flanges (wall mount installation type) for bathroom complete all as specified and directed.
M&L for pillar cock with lift type operating knob & base flange complete all as specified and directed.
M&L for single lever sink mixer with swinging spout on upper side (wall mounted model) with connecting legs & wall flanges complete all as specified and directed.
M&L for hand shower (health faucet) with 8mm dia, 1.2 meter long flexible tube & wall hook complete all as specified and directed.
M&L for SS toilet paper holder with flap recessed type (stainless steel) complete all as specified and directed.
M&L for towel rack with lower hanger (stainless steel) with hook complete all as specified and directed.
M&L for corner glass shelf (with bracket) complete all as specified and directed.
M&L for soap dish holder complete all as specified and directed.
S&F, overhead shower ø 100mm round shape single flow (ABS body chrome plated with gray face plate) with rubit cleaning system complete all as specified and directed.
S&F, bib cock (straight line model) with wall flange complete all as specified and directed.
S&F, bathroom cabinet mirror fixed in repairs complete all as specified and directed.
M&L for single lever high neck basin mixer with swivel spout & 600mm long braided hoses (table mounted) complete all as specified and directed.
M&L for single towel rail 600mm long, stainless steel complete all as specified and directed.
INTERNAL ELECTRIC SUPPLY S&F, wall mounted fan complete with accessories, 230 volts, 400mm sweep and necessary fixing complete all as specified and directed.
S&F, outdoor type feeder pillar box made out of 3.15 mm thick CRCA sheet including suitable size of angle iron frame including aluminium bus bar of capacity 400 Amps, 3 phase and neutral 4 wire system rear opening door with locking arrangment duly painted with 2 coats of synethic enamel paint over a coat of red oxide primer, internal wiring shall be of PVC insulated unshethed multi stranded copper conductor 1100 volts suitable to accommodate the follwoing switch gear as per IS including supply and fix the complete accesories mentioned below. The panel shall be fabricated from the reputed CPRI approved firm with suitable angle iron frame embeded in PCC foundation complete all as specified and directed.
(a) INCOMING: MCCB TPN 200 Amps 36 KA 4 pole - 01 No. (b) OUTGOING: MCB DP 40 Amps TP 'B' curve - 06 Nos (04 w + 02 Spare) and SP 16A-06 No's (04 w + 02 Spare). (c) LED lamp for indicator R-Y-B - 03 Nos. (d) Multifunction meter to show Voltage / Amps - set of three. (e) Cost shall include for nuts, bolts, washers etc; all as required for fixing in the existing PCC foundation. (f) Supplying and fixing smart single phase two wire dual source prepaid energy meters BIS 15884 marked floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amps, 240 Volts accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC alongwith provision of space for fixing of smart prepaid meters - 08 Nos.
(g) Panel wiring with PVC insulated unsheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size - 01 Job. (h) Interconnection of busbar with MCB and energy meter with suitable size copper cable - 01 Job. (j) Provision of cable glands and cable lugs for all incoming and outgoing cables - 01 Job. (k) Connecting the earthing to an earthing test point to main switch board as specified and testing on completion.
S&F, LED retrofit lamps 9 watt holder base with polycarbonate body and aluminium heat sink complete all as specified and directed.
S&F, decorative wall 7.5 to 10 Watts LED light (bed lamp with fitting) chrome finish fixture with opal glass diffuser suitable complete all as specified and directed.
S&F, street / security light with high quality integrated LED Luminaire with a system lumen of 11000 and system wattage not less than 90w with an efficiency 120 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be separate optical and control gear compartment and bottom opening for easy maintenance and of of high quality pressure die cast aluminum with PF > 0.95 and THD < 10% & Operating temperature: -10°C to + 50°C. Input voltage of 100-300V. Lifetime of 50K hours @ L70. Product should be suitable for continuous operation (16-18 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 07. The luminaire should have integrated peanut optics to provide a high quality glare free lighting system.
The driver should be potted and should be a BIS approved driver and not a printed circuit board without casing, mounted inside the luminaire with Phase to Phase protection Over Voltage protection, Surge Voltage protection upto 10 kV & other safety test as per IS 15885 Part-2/Sec 13. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs, should have an auto shutdown @ 325V and have an auto recovery feature. BIS approval for both driver and the luminaire needs to be submitted for records before claiming RAR complete all as specified and directed. Note: Rate quoted shall be deemed to include the cost of necessary hydraulic ladder or aerial access platform mounted on vehicle for fixing the light fittings.
S&F, GI pipe bracket for street light fitting made from 40 mm dia light grade 1500 mm long bend to shape welding etc and fixing on wall with 50 x 6 mm flat iron MS clamp and necessary nuts, bolts and washers complete all as specified and directed.
Supply and fixing of powder coated electric kitchen chimney wall mounted 220 volts, 50 Hz of 58 DB noise level, 3 number of speeds with oil collector, auto clean of dimension 48.6D x 94W x 94W x 51.5H of maximum suction 1500 metre cubic per hour having filter less, thermal autoclean technology, touch control with motion sensor complete all as specified and directed.
EXTERNAL WATER SUPPLY M&L for cutting GI pipe of any size and reducing to required length before laying and insertion of 'T's of 80 x 80 x 50mm and branches for 50 mm complete all as specified and directed.
M&L for cutting GI pipe of any size and reducing to required length before laying and insertion of 'T's of 25 x 25 x 25mm and branches for 25 mm complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY M&L for cutting of existing bituminous / PCC road or flooring / plinth protection laying of GI pipe in intersection for passing of LT XLPE cable including excavation in any type of soil returning filling in and making good top 30 cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as specified and directed.
Supply, commissioning & testing LT panel board made out of CRCA sheet 2.0 mm thick indoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements alongwith lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear and the nuts / bolts used are to be made of rust proof material including as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V including suitable capacity of busbar complete with powder coating, necessary internal electric connection as required and provision of the following: -
a) Suitable capacity of aluminium bus bar, TPN full for phase and neutral with colour code PVC sleeves - 01 Job. Incoming: a) 400 MCCB Amps, electric, 4 Pole, 415 Volts, 50 Hz, 25 kA - 01 No. Outgoing: a) 200 MCCB Amps, electric, 4 Pole, 415 Volts, 50 Hz, 25 kA - 03 Nos (2W+1S). b) LED RYB indicating lamps - 01 set. c) LED Ammeter and voltmeter with necessary CTs and display of required rating. d) Panel wiring with PVC insulated unsheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size - 01 Job.
e) Interconnection of busbar with MCCB, contactor with suitable size aluminium strip - 01 Job. f) Provisioning of cable glands and cable lugs for all incoming and outgoing cables & connecting the earthing to an earthing test point to main switch board as specified and testing on completion - 01 Job.
AREA LIGHTING S&F, 90W LED street light with high quality integrated LED luminaire with a system lumen of 11000 and system wattage 90W with an efficiency, not less than 100 lumen/watt. CCT of 5700K with SDCM of <5 and CRI >70. The housing should be separate optical and control gear compartment and bottom opening for easy maintenance and of high quality pressure die cast aluminium with PF > 0.95 and THD < 10% and Operating temperature: -10°C to + 50°C. Input voltage of 100-300V. Lifetime of 50K hours @ L70. Product should be suitable for continuous operation (16-18 Hrs. per day). The ingress protection should be minimum IP 66 with an IK rating of 07. The luminaire should have integrated peanut optics to provide a high quality glare free lighting system.
The driver should be potted and should be a BIS approved driver and not a printed circuit board without casing, mounted inside the luminaire with Phase to Phase protection Over Voltage protection, Surge Voltage protection upto 10 kV & other safety test as per IS 15885 Part-2/Sec 13. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs, should have an auto shutdown @ 325V and have an auto recovery feature complete all as specified and directed.
M/s. P S REDDY (BID ID -3304470)
P Govinda Reddy Infrastructure (BID ID -3303897)
R. Wadhumal and Sons (BID ID -3303594)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .