Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹11.2 L+₹1.9 L (20.0%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹13.1 L+₹3.8 L (40.8%)Rejected-Finance M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹14.8 L+₹5.5 L (59.2%)Rejected-Finance WZ 88A JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | Rejected-Technical 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | - | Rejected-Technical NOT HAVING DESIRED CATEGORY |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
13 Sept 2024, 6:00 pmClosed
GE (AF) PALAM
GE (AF) PALAM DELHI CANTT-10
REPAIR/MAINTENANCE OF AMC FOR FIRE ALARM SYSTEM INSTALLED AT DIFFERENT LOCATION AT AF STN PALAM UNDER GE (AF) PALAM, DELHI CANTT-10
2024_MES_666946_1
8024/A/T-35/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) PALAM
₹30,000
Yes
23 Nov 2024
20 Jul 2024
20 Sept 2024
20 Jul 2024
13 Sept 2024
3 Aug 2024
Amount
Comprehensive monthly maintenance of Auto Fire Alarm System installed in BBJ Hanger & RSS Hangar and ISH in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 Nos. (b) UL Listed intelligent addressable multi-criteria detector with base- 284 Nos. (c) UL Listed intelligent heat detector - 08 Nos. (d) Manual call point - 08 Nos. (e) Control module for hooter - 18 Nos. (f) zone Monitor module - 28 Nos. (g) Fault isolator - 12 Nos. (h) Wall mounted hooter - 18 Nos. (j) Response indicator - 25 Nos. (k) IR Flame detector - 28 Nos. (l) UPS 1 KVA - 02 No.
Comprehensive monthly maintenance of auto fire alarm system installed in AW 101 Hanger No I, II & III in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 192 Nos. (c) UL Listed intelligent heat detector - 02 Nos. (d) Manual call point - 18 Nos. (e) Control module hooter - 05 Nos. (f) Monitor module - 06 Nos. (g) Fault isolator - 12 Nos. (h) Wall mounted hooter - 06 Nos. (j) Response indicator - 70 Nos. (k) IR Flame detector - 44 Nos. (l) UPS 1 KVA - 02 Nos.
Comprehensive monthly maintenance of Auto Fire Alarm System installed in SES LAB OF 181 FLIGHT, TWIN DSS BLDGS & CARGO TERMINAL in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Material required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 59 Nos. (c) Manual call point - 05 Nos. (d) Control module for hooter - 05 Nos. (e) Fault isolator - 04 Nos. (f) Wall mounted hooter - 07 Nos. (g) Response indicator - 07 Nos.
Comprehensive monthly maintenance of Auto Fire alarm System installed in SIGNAL EXCHANGE BLDG in Camp area & EDN SECTION in Camp Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 99 Nos. (c) UL listed intelligent heat detector-02 Nos (d) Manual call point - 08 Nos. (e) Control module for hooter - 08 Nos. (f) Monitor module- 09 Nos (g) Fault isolator - 06 Nos. (h) Wall mounted hooter - 08 Nos. (j) Response indicator - 48 Nos.
Comprehensive monthly maintenance of auto fire alarm system installed in 737 Boeing Lab, 41 SQN Simulator Bldg in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 02 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 130 Nos. (c) UL Listed intelligent heat detector - 04 Nos. (d) Manual call point - 11 Nos. (e) Control module for hooter - 06 Nos. (f) Monitor module - 05 Nos. (g) Fault isolator - 12 Nos. (h) Wall mounted hooter - 20 Nos. (j) Response indicator - 48 Nos. (k) UPS 1 KVA -02 Nos.
Comprehensive monthly maintenance of auto fire alarm system installed in AFCNWP CAMP AREA at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 01 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 65 Nos. (c) UL Listed intelligent heat detector - 06 Nos. (d) Manual call point - 06 Nos. (e) Control module for hooter - 06 Nos. (f) Monitor module - 06 Nos. (g) Fault isolator - 06 Nos. (h) Wall mounted hooter - 06 Nos. (j) Response indicator - 13 Nos.
Comprehensive monthly maintenance of auto fire alarm system installed in SES SCTION OF CPRU, COLOUR LAB, CFNL LAB IN TECH AREA at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 03 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 162 Nos. (c ) UL listed intelligent heat detector - 02 Nos (d) Manual call point - 14 Nos. (e) Control module for Manual call point - 14 Nos. (f) monitor module - 06 Nos. (g) Fault isolator - 10 Nos. (h) Wall mounted hooter - 14 Nos (j) Response indicator - 72 Nos. (k) sounder relay - 08 Nos. (l) UPS 1 KVA - 03 Nos. (m) central control including 21" colour monitor 21"and its CPU , Key board ,mouse & UPS -01 Set (n) Repeater panel -01 No
Comprehensive monthly maintenance of auto fire alarm system installed in ISR LAB,(T),73 RMU(T),WEATHER BUILDING (C), BBJMCF(T) IN TECH AREA at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) UL Listed auto fire alarm control panel having micro processor based two loop cards (252 device/loop card) - 03 No. (b) UL Listed intelligent addressable multi-criteria detector with base- 102 Nos. (c) Manual call point - 14 Nos. (d) Control module for Manual call point - 20 Nos. (e) monitor module - 06 Nos. (f) Wall mounted hooter - 4 Nos (g) sounder relay - 4 Nos. (h) UPS 1 KVA - 04 Nos.
Supply, installation, testing and commissioning in replacement of Photo electronic type smoke cum heat detector IP67 rated , having removable high performance chamber with Twin fire LED's allow 360 degree veiwing, lock mechanism ( sensor to base), employ two heat sensing elements with different thermal characteristics to provide a rate of rise dependent response.Electronically addressed, approved by LPCB. Flat FAST addressing technique Flexible (programmed in any sequence), Automatic (stored in EEPROM).(EN-54 approved) conforming to IS-11360 -1985 having dual ionized chamber meant for easy detection of high carbonized fumes by means of light emitting principle complete with base, UL FM LPCB complete all as specified and directed by engineer in charge. Make: Ceasefire/siemens/honeybell
Supply only in replacement of addressable manual call point/pull station single action type with gold plated SPST contacts complete all as specified and as directed. Make: Ceasefire/siemens/honeybell
Supply & fixing in replacment of detector complying with and type certified to EN 45 addressable type flame detectors with UV/IR detection capacity complete all as specified and as directed by Engineer -in- Charge. Make:Ceasefire/siemens/honeybell/Apolo
Supply only in replacement of addressable control relay module for manual call point complete all as specified and as directed. Make:- Ceasefire/siemens /honeybell/ Apolo.
Supply only in replacement of intelligent addressable monitor module complete all as specified and as directed. Make:- Ceasefire/siemens /honeybell/ Apolo.
Supply only in replacement of hooter with control module complete all as specified and as directed. Make:Ceasefire/siemens /honeybell/ Agni protection.
M&L for taking out unserviceable Power supply unit Model PSC-12 of Siemens Make from the existing Fire detection control panel and repairing the unit including replacement of unserviceable parts complete and refixing the same in its original position including testing commissioning complete all as specified and directed.
Supply only in replacement of PCB loop cord suitable for self addressable fire finder system complete all as specified and as directed
Supply & fixing in replacement of PVC insulated armoured copper conductor cable size 1.5 sqmm 2 core FRLS 1100 volts fixed on wall/celling of the hanger with fixing accessories complete all as specified and as directed.
S & F in replacement of PVC insulated PVC sheathed copper conductor cable size 1.5 sqmm 2 core FRLS 1100 volts drawn in existing PVC conduit fixed on wall/celling of the bldg complete all as specified and as directed.
Supply and fixing in replacemnt of PVC conduit medium grade of size 20 mm dia including fixing accessories like saddles, couplers bends tees etc complete all as specified and as directed.
Supply only in replacement of UPS 1.0 KVA suitable for working on 230 Volts, 50 Hz AC supply complete all as specified and as directed.
Supply only in replacement of Battery 12 Volts 7 AH dry type complete all as specified and as directed.
Disconnecting and taking out old unserviceable CPU display unit including PMI of fire finder and S&F new CPU display unit including PMI suitable for self addressable fire finder XLS system complete all as specified and as directed. Make:- Siemens/ Honey well/Edward
Supply, installation, testing and commissioning in replacment of microprocessor based 4 Zone conventional fire alarm control panel robustly designed and easy to operate, fully compliant with and tested to BS EN 54-2 and BS EN 54-4, Compatible for use on BS5839, Part 1, 2002 installation, 2 wire repeaters and ancillary boards, fully programmable using simple menu options, simple, single board construciton, installer friendly, compatible with Hochiki, conventional range of devices, two monitored sounder outputs, 3 Amp power supply, auxiliary power output, The control must be EN 54 approved, complete all as specified and as directed by Engr-in-Charge. Make : Ceasefire/fire protection/siemens/honeybell.
Supply, installation, testing and commissioning in replacment of (multi criteria) type detector with base combination of both heat and smoke detection arrangement of the same make as of fire alarm control panel. Detector should have a third terminal to provide an integral remote indicator output, removable high performance chamber, remote indicator output, wide voltage range (9.5 to 30V d.c) low profile design with one piece outer cover, twin fire LED's allow 360 degree viewing, range of mounting bases, approved by LPCB complete all as specified and as directed by Engr-in-Charge Make : Ceasefire/LTS/Agni protection
S&F in replacement coventional Manual Call Point having status LED for Alarming & standby mode,inbuild short circuit isolator,Electronically addressed approved by LPCB as EN54-11: 2001 all as specified and directed by Engineer- in- charge. Make:- Ceasefire//LTS/Agni protection
S&F in replacment of fire alarm control panel complying with BSEN 54 single loop panel of capacity from 99 detectors 200 detectors and module 1 loops networkable surface mounting FACP certified to EN54-2/EN54-4 norms can be Networkable capability of up to 64 Panels with 500 software zones. Large with 8x40 character LCD . The FACP shall be certified as meeting the requirements of EN54-2 and EN54-4 by a suitable, notified body. In order to facilitate re-configuration and system extension, the allocation of addresses to devices shall be independent of their physical arrangement on the loops and Sensitivity adjustment and Drift Compensation. The FACP shall capable analogue addressable wired and wireless sensors & modules Up to 127, plus 127 analogue base sounder / Beacon for total 254 point shall be configured on each addressable loop. The FACP shall have an event log capable of storing the last 500 events that have occurred. Loop powered sounders incorporated as a sensor bases shall be available. The FACP shall have the capability to support sub-addressing of addressable modules. The FACP shall monitor all critical system components and interconnections, internal and external, such that a failure, which would prevent the correct operation of the alarm functions, causes the FAULT indicator to light and a message to be given on the alphanumeric display within 60 seconds of occurrence. The FACP shall support minimum Four access levels,flash EPROM, programmable sounder circuits. The FACP Shall be housed in Ms Powder coated Cabinet, complete with exclusive Notification Circuits, and with Fire, Fault & Auxiliary Relays.The Panel shall support to programmed as a node on a peer to peer network with other Panels. Make: Siemens /HoneywellCeasefire/agni protection/apollo
M & L for programming of addressible control panel with suitable equipment as per marking of the fire sensor/flame sensors complete in every respect all as specified and directed by Engineer -in-Charge.
Sumit Enterprises (BID ID -3078718)
Friends fire Engineers (BID ID -3093254)
SANWARIYA ENTERPRISES (BID ID -3089219)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .