Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 CrAdmitted-Finance N A | ₹9.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹9.3 Cr+₹15.2 L (1.66%)Admitted-Finance ALAKPURI NEAR DURGA MANDIR DIST GIRIDIH | GIRIDIH | JHARKHAND | 815301 | ₹9.3 Cr+₹15.2 L (1.66%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected Technical Bid |
| 4 | Not Admitted-Fee/PreQual/Technical DUMKA ROAD OPPOSITE IRRIGATION COLONY JAMTARA JHARKHAND 815351 | JAMTARA | JHARKHAND | 815351 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Maa Tara Infrastructure and Builders Pvt Ltd L1 | Mahadeva Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I. | 2,643.03 | Cum | 110 ₹2,90,732.97 Lowest | 115.92 ₹3,06,379.69 |
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over area (exceeding 30cm depth 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5M disposed earth to be levelled and neatly dressed - ordinary rock | 750 | Cum | 310 ₹2,32,500 Lowest | 324.33 ₹2,43,247.5 |
| 3.00 | Hard rock (blasting prohibited) | 500 | Cum | 900 ₹4,50,000 Lowest | 935.12 ₹4,67,560 |
| 4.00 | Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) | 317.27 | Cum | 225 ₹71,385.08 Lowest | 236.75 ₹75,112.96 |
| 5.00 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume). | 62.08 | Cum | 95 ₹5,897.6 Lowest | 98.41 ₹6,109.29 |
| 6.00 | Providing designation 75A one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I. | 2,650.24 | Sqm | 230 ₹6,09,554.74 Lowest | 245.14 ₹6,49,679.34 |
| 7.00 | Providing P.C.C.M - 100 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade III (50mm to 25mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l. | 6.04 | Cum | 3,900 ₹23,546.25 Lowest | 4,108.93 ₹24,807.66 |
| 8.00 | providing R.C.C.M - 150 with nominal mix of (1'2"4 ) in foundationland plintn with approvecl qLrality of stone chips 20 mm to 6 mm'lsize qraded and clean ccarse sand of F M 2 5' to 3 includingl=.roJnino shuttering' mixing cement concrete in mixer and
lptucing in position, vibrating, striking, curing (butexcluding theicost of renifr-,rcement, taxes and royalty all complete' as per,ritCino s',:ecification :rnd direction of E/l | 29.93 | Cum | 5,400 ₹1,61,595 Lowest | 5,680.36 ₹1,69,984.77 |
| 9.00 | Providing P.C.C. M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone metal grade-III( 50 mm to 25 mm size) graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l. | 117.29 | CUM | 5,400 ₹6,33,387.6 Lowest | 5,680.36 ₹6,66,272.15 |
| 10.00 | Providing RCC M-200 with nominal mix of (1:1.5:3) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I. | 435.51 | CUM | 5,900 ₹25,69,485.4 Lowest | 6,178.74 ₹26,90,878.34 |
Tender Value
₹8.7 Cr
EMD Value
₹8.7 L
Closing Date
3 Feb 2021, 11:00 amClosed
Nodal Officer
e-Procurement Cell, JSBCCL Building, 3rd Floor, Project Bhawan Campus, Dhurwa, Ranchi-834004, Jharkhand
Construction of 5000 MT Capacity Cold Storage in Dumka District
2021_JSBCC_47328_1
JSBCCL/18/2020-21
Open Tender
Civil Works - Buildings
Item Rate
450 days
JHARKHNAD
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
JSBCCL
₹8.7 L
Yes
10 Mar 2021
20 Jan 2021
5 Feb 2021
20 Jan 2021
3 Feb 2021
20 Jan 2021
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over area (exceeding 30cm depth 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5M disposed earth to be levelled and neatly dressed - ordinary rock
Hard rock (blasting prohibited)
Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume).
Providing designation 75A one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I.
Providing P.C.C.M - 100 with nominal mix of (1:3:6) in foundation with approved quality of stone metal grade III (50mm to 25mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l.
providing R.C.C.M - 150 with nominal mix of (1'2"4 ) in foundationland plintn with approvecl qLrality of stone chips 20 mm to 6 mm'lsize qraded and clean ccarse sand of F M 2 5' to 3 includingl=.roJnino shuttering' mixing cement concrete in mixer and lptucing in position, vibrating, striking, curing (butexcluding theicost of renifr-,rcement, taxes and royalty all complete' as per,ritCino s',:ecification :rnd direction of E/l
Providing P.C.C. M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone metal grade-III( 50 mm to 25 mm size) graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing RCC M-200 with nominal mix of (1:1.5:3) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing RCC M-200 with nominal mix of (1:1.5:3) in beam of all types with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing RCC M-200 with nominal mix of (1:1.5:3) in Column with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing RCC M-200 with nominal mix of (1:1.5:3) in roof slab with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing R.C.C. M - 200 with nominal mix of (1:1½:3) in lintel with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, centering, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/l.
Providing av. 63mm thick R.C.C.M-200 with nominal mix (1:1½:3) in chajja with approved quality of stone chips 20 mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including making drip course in concrete, screening, centering, shuttering and mixing cement concrete in mixer and placing in position, vibrating, striking, 6mm cement plaster (1:4) in ceiling and sides of chajja with sand of F.M. 1.5 curing (but excluding the cost of reinforcement) taxes, and royalty all complete as per building specification and direction of E/l.
Providing RCC M-200 with nominal mix of (1:1.5:3) in stair case with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer, placing in position vibrating striking curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I.
Providing R.C.C. M - 200 with nominal mix of (1:1.5:3) in band at plinth level with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, centering, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/l.
Providing TMT reinforcement of following dia rods as per approved design and drawing including carriage of M.S. rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.
8 mm dia (20 %of total reinforcement)
10mm dia (15%of total reinforcement)
12mm dia (15%of total reinforcement)
16 mm dia (30 % of total reinforcement)
20 dia(20 %of total reinforcement)
CABLE GRATING over the cable trench for cover
CABLE TRAY FOR SUPPORTING CABLE INCLUDING SUPPORTING FLENGE & CABLE TRAY SUPPORT BRACKET 600 mm width X 62.5 mm depth X 2.0 mm thickness
Providing and mixing Liquid lntergral water proofing compound in Conctrete or plaster as per rnanufacturer specificatioqand as per cjirection of Eng - in Charge Brand- Sika Plastocrate plus, MYK proof WP 1 0, Fosroc-Cc.rnplast X4211 C, Dr fixit Pidiproof LW+ or Equivalent
Extra for R.C.C .or P.C.C. work for each consecutive floor above first floor complete as per direction of E/I
Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.)
Earth filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Proviriing desIgnation '100 A brick work with fly ash lime brick (FLAG) confirming to lS 12894-199C (9"x4.5'x3") in C M (1 :6)in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 inciudinq providing 10 min thick mo(ar joints, cost of screening materials, rakinq out loirrts to 15mm depth, curing, taxes and royalty allcomplete
Providing designation 112 mm thick reinforced designation 100 A brick work vuith fly ash lirne brick (FLAG)confirming to lS 12894-1990 (9"x4'5"x3" ) in C.M. ( 1 . 4 ) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building speci
Extra for brick work for each consecutive floor above first floor including watering and scafolding, all complete as per direction of E/l.
Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Extra for plaster work exteriour surface for each consecutive floor above first floor including cost of scaffolding ect all complete as per directiopn of E/I
Providing two coats of snowcem of approved shade and make over New surface including washing cleaning, and preparing the walls, scaffolding, curing and taxes all complete as per building specification and direction of E/l.
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.(50x75x6MM)
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Extra for each coat of cement wash, distemper paint or snowcem over exterior surface for each consecutive floor above first floor including scaffolding etc all complete as per specification and direction of E/l.
Providing P.C.C. M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone chips 20 mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l.
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in roof members as pillars, plates, rafters, purlines, beams any type of batten with cost of nuts and bolts complete with cleats (with wooden checks) fitting with screws all complete as per building specification and direction of E/l.
Bamboo chali (75mm thick) work in each floor for item stocking from 75 mm dia 6-8 m long bamboo
storage space -1 =27.9x4.11=114.67. each floor 6 pannel and sorage at two level On each and every 5 floor , Nos of total space =(10x6x114.67 )
Providing 19 mm thick water proof cement plaster (1:3)with clean coarse sand of F M 1.5 with lntegral water proofrng compound Liquid @'125 ml per bag cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X4211C, Dr.fixit Pidiproof LW+ or equivalent.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion
110 mm bend
Shoe (Plain)110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)
Supplying, fitting and fixing callapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2 mm at 100mm. centres and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage , hoisting and taxes all complete as per building specification and direction of E/l.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
Supplying, fitting and fixing fully glazed steel door, windows or ventilations of standard rolled 'Z' and mullion steel sections and size as per IS-1038 joints met and welded with 100x16x3mm M.S. lugs fixed in cement concrete (1:2:4) blocks 15x10x10 cm size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/l.
Providing two coats of synthetic enamel paint over a coat of primer of approved shade and make over new wooden surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specfication and direction of E/l.
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust , dirt, , scales , smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification)
Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm square bars fitted on 25x25x6mm M.S Angle frame including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l. (where steel is not supplied by the deptt.)
Providing and fixing in position 25 mm thick bituminastic board (shalitex or Equivalent as per IS:1838-1983) in expansion of construction joints in barrage and its allied works as per specification and direction of E/I
Providing and fixing sheet covering over expansion joints with iron screws as per design. Aluminium fluted strips 3.15 mm thick. 200 mm wide
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
Providing 250mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l.
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
(c) From126.0 M to150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etc all complete job as per direction of E/I.
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing lowering 50 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
S/F sheet metal ON/OFF- Load changeover:-Providing and fixing following capacity 2pole/4pole On /OFF Load changeover switches with side handle operiation , in sheet encloser in existing metal board including drilling holes in metal board , making connection ,earthing yhe body etc as required 200 amps, 4pole
200 amps, 4pole
S/F 'C' series SP MCB: Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required.
6/32A TPN MCB
50/63A TPN MCB
S/F 'B' series,S.P MCB:- Supplying and fixing 6 amp to 32 amp rating ,240 volts 'B' series ,miniature circuit breaker suitable for lighting and other loads of following poles in the exisitng MCb DB complete with connection ,testing and commissioning etc,as required
6/32 amps single pole "B" series
150 sq mm 3.5 core
95 sq mm 3.5 core
35 sq.mm 3.5 core
Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.
2x6.0 Sq.mm + 1x6.0 Sq.mm earth wire (
2x10.0 Sq.mm + 1x10.0 Sq.mm earth wire
4x6.0 Sqmm + 2x6.0 sqmm earth wire
4x10 Sqmm +2x10 sqmm earth wire
G.I. Earth pipe Elecrode with salt/charcoal:- Earthing with G.I. earth pipe 3 m, 40 MM dia including accessories and providing massonary enclose with cover plate having locking arrangement and watering pipe etc with charcoal and salt
S/L 8 SWg copper wire inground:- Supplying laying 8 SWg wire at 0.50 meter below ground level for conductor earth electrod ,including soldering etc. as required
P/F Copper lightning conductor finial :- Providing and fixing of lighting conductor finial, made of 25mm dia 300mm long copper tube, having single prong at top, with 85mm dia 3mm thick copper base plate including holes etc. complete as required.
Reverting, sweating, and soldering lightning conductor tape:- Reverting, sweating and soldering of copper/G.I. tape (with another copper/ G.I. tape, base of the finial or any other mettallic object) etc. as required.
P/F Copper lightning conductor tape in horizontal run:- Providing and fixing tape 20MM x3MM thick on parapet or surface of wall for lighting conductor complete as required (for horizontal run)
P/ F G.I Lightning conductor tape in vertical run :- Providing and Fixing copper Tape In vertical run: Providing and fixing of copper tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete etc. as required (vertical run).
P/F MV Danger Notice Plate:- Providing and fixing M.V. danger notice plate of 200mmX150mm, made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in the single red colour on front side as required.
P/F MV Danger Notice Plate:- Providing and fixing H.T danger notice plate of 250mmX200mm, made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in the single red colour on front side as required.
S/F of fan 1200 MM (48" dia ) a.c celling fan
ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required.
S/F Modular type electronic fan regulator: Supplying and fixing stepped (two module) type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required.
S/F light plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 5 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.(Note:- Near all LAN points 3 Nos. 5/6 Sockets with Switch, all switch borads with sockets indifferent rooms, all 5/6A separate switch sockets, all corridor and stair case 5/6A socket switch for Fire alarm system, all racks for lLan must have one 5/6A socket with switch with UPS support etc.
S/F power plug point with modulartype accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
S/F TP MCB DB: Supplying and fixing following way,three pole and neutral sheet MCB distribution board, 415 volts on surface/recess complete with tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections,phosphatised and powder painted including earthing etc. as required ( But without MCB/RCCB/ ISOLATOR).
4 ways (4+12) Double Door. (horizontal type
6 ways (4+18) Double Door. (horizontal type
8 ways (4+24) Double Door. (horizontal type
S/F Modular type blanking plate :- Supplying and fixing modular blanking plate on existing modular plate and switch box excluding modular plates as required
Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.
Group- C
S/F Electonic Musical Call Bell: Supplying and fixing electronic musical call bell suitable for D.C./A.C. single phase, 230Volts, complete etc as required.
Supplying and erection of galvanised ‘D’ iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required.
Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required.
Bus Bar
1 sets of 630 amp, 415V ,3 Pase , 50 Hz Al. Busbar.
Installation, Testing and commissioning of LT Panel as describe above.
S/F AMF Pannel for 320 KVA DG Panel
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 Amp , 16 KA , FPMCCB
Supplying and fixing following rating, double pole, (single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliampapers in the existing MCB DB complete with connection, testing and comissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 Amps ,16 KA ,FPMCCB
Supplying and fixing following rating, double pole, (single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliampapers in the existing MCB DB complete with connection, testing and comissioning etc. as required.
S/F HRC fuse type TP&N switch Disconnector Providing and fixing following capacity double pole TP&N sheet metal switch disconnector fuse switch unit inexisting metal board with ISI marked HRC fuses including drilling holes in metal board , making connections, etc. as required.
200 Amps ,36 KA ,FPMCCB
Supplying and fixing following rating, double pole, (single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliampapers in the existing MCB DB complete with connection, testing and comissioning etc. as required.
S/F HRC fuse type TP&N switch Disconnector Providing and fixing following capacity double pole TP&N sheet metal switch disconnector fuse switch unit inexisting metal board with ISI marked HRC fuses including drilling holes in metal board , making connections, etc. as required.
200 Amps ,36 KA ,FPMCCB
Supplying and fixing following rating, double pole, (single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliampapers in the existing MCB DB complete with connection, testing and comissioning etc. as required.
3C x 400 sqmm 11/11 KV HT XLPE ALUMINUM CONDUCTOR ARMOURED CABLES (KEI)
Laying of one number PVC insulated ans PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required.
up to 35 sq mm
above 35 sq.mm and up to 95 sq mm
MV Cable Laying up to 400 sq. mm. in trench :- Laying of one number additional PVC Sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 120 sq.mm. but not existing 400 sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.( for 150 Sqmm cable)
MV Cable Laying up to 400 sq. mm. in trench :- Laying of one number additional PVC Sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 120 sq.mm. but not existing 400 sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying and fixing of one number PVC insulated ans PVC sheathed / XLPE Power cable of 1.1 kV grade of following size on wall surface as required.
Upto 35 Sq.mm ( clamp with 1mm thick saddle)
Above 35 Sq.mm and up to 95 sq. mm ( Clamp with 25x3mm MS Flat clamp)
Above 95 Sq.mm and up to 185 sq. mm ( Clamp with 25/40x3mm MS Flat clamp)
Above 185 Sq.mm and up to 400 sq. mm ( Clamp with 40x3mm MS Flat clamp)
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing material for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3.5 X 35 sq. mm
3.5 X 95 sq. mm
3.5x150sq.mm
3.5x400sq.mm
Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.
2x1.5 Sq.mm + 1x1.50 Sq.mm earth wire
2x2.5 Sq.mm + 1x2.5 Sq.mm earth wire
2X4 Sq mm +1X4 Sq. mm Earth wire
Hot dipped Galvanized Iron Cable Tray 450mm width X 50 mm deph X 2.0 mm thickness
Power Plug wiring in PVC conduit ( 2 x 4 Sqmm):- Wiring for light / Power plug with 2x 4 Sq. mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 nos. 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required :-
S/L 25mm x 5mm G.I earth strip in ground :- Supplying laying 25mm x 5mm G.I strip at 0.50 meter below ground as strip earth electrode, including soldering etc. as required.
supply of Exhaust Fan upto 450 mm sqeep
S/F Modular boxes, base & cover plate :- Supplying and fixing following size/ modules G.I box along with modular base & cover plate for modular switches in receess etc as required.
8/9 MODULE (78MM X 230MM X 60MM)
12 MODULE (135MM X 205MM X 60MM)
4/5 Module (78 mm X140mmx50mm)
6 Module (78 mm X205 mmx50 mm)
Supplying of surface /pendent mounting industrial T5 luminari
Supplying of surface /Pendent Mounting T5 luminaires 150 W
Supplying of Led Tube light
Suppying of CFL Bulk Head luminaires
Supplying of Led Street Light
Supplying of Co2 type fire existnguisher (4.5KG)
Supplying of 6KG ABC (POWER TYPE) FIRE EXTINGUISHER
S&F installation ,testing and commissioning of 11/0.415 KV (350KVA) 3 Phase oil immeresed step down distribution transfermer for out door installation
Supply and errection of 100 mm x 65 mm pin insulator complete with G.I spindle and nut etc. as required.
Supplying of C.C .pole up to 11 m in B.B:- Supply of RCC/PCC pole of length excluding 8 meter but not exceeding 11 meters.(CP-1.15%)
Erection of steel pole up to 12 m in C.C:- Erection of steel pole tubular pole of length excesding 10 meters but mot exceeding 12 m in cement concrete 1:3:6(1 cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation refilling etc. as required
Supply of HT PANEL 11 KV (Enclosure)
VCB ( Vacume Circuit Breaker)
Isolator
Multi Function Meter
Potential Transformer ( PT)
Current Transformer ( CT)
Over load relay
Earth Fault
R,Y,B Indication Lamp
Instaulation testing and commesning
Supplying of Cpacitor Panel : ( 36 KA ) Incoming ( 100 Kvar)
Bus Bar
One set of 300 Amp, 415 Volt, 3 Phase ,TPN Cu Bus bar.
Out going
For 10KVAr – 3 STEPS
MCCB, 3P, 36KA CVS TMD type - 3Nos -25A TVS E type, TP, Power Contactor – 18A - 3Nos 7% detuned reactor, 440V, Al wound type - 10kVAr - 3Nos
For 20KVAr – 1 STEP
MCCB, 3P, 36KA CVS TMD type -50A - 1 No. TVS E type, TP, Power Contactor – 50A - 1 No. 7% detuned reactor, 440V, Al wound type - 20kVA - 1 no.
For 50KVAr – 1 STEP
MCCB, 3P, 36KA CVS TMD type -100A- 1 No. TVS E type, TP, Power Contactor – 95A 1 No. 7% detuned reactor, 440V, Al wound type - 50kVAr - 1no.
Installation, Testing and commissioning of APFC Panel as describe above
400 SQMM HEAT SHRINKABLE 6.6 KV (E/UE) 11KV (E) XLPE OUT DOOR TERMINATIONS (3 CORE) (DENSONS)
20mm dia ISI marked , PVC pipe
20 mm dia Flexible pipe
20 mm bend
20 mm four way PVC moduled circular with led and screw
Supplying and I fixing following moduler switch/soket on existing moduler plate & switch box including connection but excluding modular plate . As required.
5/6 A Switch
15/16A switch
3pin 5/6 A soket outlet
6m/pin 15/16 A soket outlet
400 sq mm 3.5 core
Supply and installation of Silent type Diesel Generating set alongwith having prime power Rating Suitable to Drive of 320 KVA, 415 Volt at 1500 RPM, 0.8 lagging power factor at 415V suitable for 50 Hz, 3Phase system generator & for 0.85 Load Factor.
PUF PANEL Thermal Insulation (Ground Floor)
Wall Panel (Panel thickness 100 mm),(for complete job)
CeiIing Panel (Panel thickness 100 mm),(for complete job)
(for complete job)
Partition Panel in depth( 1 Nos.)(for complete job)
Partition Panel , (for complete job)
Door Accessories without heater( Swing Door),(for complete job)
Hatch window with/without heater,(for complete job)
Sealant for puff panel joints filling.,(for complete job)
Bulk Head,(for complete job)
Presser Relief Valve without heater,(for complete job)
SLIDING DOOR (1500 x 2100mm),(for complete job)
Hanging Accessories,(for complete job)
CHAMBER -2 MULTI COLD STORAGE.
Air Cooled Condensing Unit for Multi Cold Storage Chamber. F150 Condensing Unit with 4GE-30Y Single Stage Semi-Hermetic Reciprocating Compressor operating at -2°C Evaporating Temperature with 50.5 KW(14.4TR)& +50°C Condensing Temperature . This Condensing Unit consisting Condenser, Compressor, Condenser Fan with Motor, HP/LP Switch, Liquid Solenoid, Filter Drier, Sight Glass, Oil Pressure Switch, Discharge Vibrator, NRV for Discharge Line, Accumulator, Receiver & Oil Seperator. Connected Load is 26.65 kW ,(for complete job)
Ic.Regular Evaporator unit ,(for complete job)
Electrical Panel ,(for complete job)
Copper piping between IDU & ODU. ,(for complete job)
Stand Evaporator hanging ,(for complete job)
Referigerant R 404a Gas ,(for complete job)
Cable ,(for complete job)
Service ,(for complete job)
CHAMBER -3&4 FRUITS &VEGETABLES(GROUND FLOOR)
Air Cooled Condensing Unit for Fruits Chamber & Vegetable Chamber D047 Condensing Unit with ZB26 Hermetic Scroll Compressor operating at -2°C Evaporating Temperature & +50°C Condensing Temperature with 20.8 kW(5.95TR). This Condensing Unit consisting Condenser, Compressor, Condenser Fan with Motor, Split Valve, HP/LP Switch, Liquid Solenoid, Filter Drier, Sight Glass, Receiver & Oil Seperator Connected Load is 9.45kW ,(for complete job)
Ic.Regular Evaporator unit ,(for complete job)
Electrical Panel ,(for complete job)
Copper piping between IDU & ODU. ,(for complete job)
Stand Evaporator hanging ,(for complete job)
Referigerant R 404a Gas ,(for complete job)
Cable,(for complete job)
Service ,(for complete job)
PUF PANEL Thermal Insulation ( First Floor )
Wall Panel (Panel thickness 100 mm) ,(for complete job)
Ceiling Panel (Panel thickness 100 mm) ,(for complete job)
Floor panel (slab thickness 80mm),(for complete job)
Sealent,(for complete job)
Bulk Head,(for complete job)
Presser Relief Valve without ,(for complete job) heater
SLIDING DOOR(1500 x 2100),(for complete job)
Hanging Accessories,(for complete job)
CHAMBER -1 POTATO.(FIRST FLOOR. )
Air Cooled Condensing Unit for Potato Chamber. F150 Condensing Unit with 4GE-30Y Single Stage Semi-Hermetic Reciprocating Compressor operating at -2°C Evaporating Temperature with 50.5 KW(14.4TR) & +50°C Condensing Temperature . This Condensing Unit consisting Condenser, Compressor, Condenser Fan with Motor, HP/LP Switch, Liquid Solenoid, Filter Drier, Sight Glass, Oil Pressure Switch, Discharge Vibrator, NRV for Discharge Line, Accumulator, Receiver & Oil Seperator. Connected Load is 26.65 kW,(for complete job)
Evaporator Unit,(for complete job)
Electrical Panel,(for complete job)
Copper piping between IDU & ODU.(for complete job),(for complete job)
Stand Evaporator hanging (for complete job),(for complete job)
Referigerant R 404a Gas(for complete job)
Cable(M)(for complete job)
Service(for complete job)
Control Panel Including PLC(for complete job)
Lift with complete installation
Sand 10 KM
Aggregate 25 KM
Brick 8KM
Fly Ash Bricks 10KM
Add 12% GST
Add 1% Labour Cess
Mahadeva Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
Tendernotice_2.pdf
PDF • 0.31 MB
SBD-18.pdf
Tender Documents • 1.29 MB
BOQ_62393.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .