| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹31.6 L+₹74,173 (2.40%)Rejected-AOC | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹36.0 L+₹5.1 L (16.4%)Rejected-AOC NO 45 5TH CROSS MALLAPPA LAYOUT BABUSAPALYA KALYAN NAGAR BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L3 | Rejected-AOC Not lowest |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
8 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
PROVISION OF SETTING UP OF TEST BED FACILITY AT CAIR, DRDO TOWNSHIP, BANGALORE
2021_MES_451404_1
GE(I) R ND D (WEST)/BAN/35 OF 2021-22 8905E8
Open Tender
Civil Works
Item Rate
180 days
Bengaluru
Class and Category as per NIT
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹69,000
Yes
9 Oct 2021
27 Jul 2021
14 Sept 2021
28 Jul 2021
8 Sept 2021
26 Aug 2021
28 Jul 2021 - 25 Aug 2021
60 days
Amount
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and disposing of debris outside MD land, complete all as specified and as directed.
Demolition of floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles to store and rubbish off the premises and disposing of debris outside MD land complete all as specified and as directed.
Demolition of reinforced cement concrete as in shelves, in any position not otherwise specifically provided for, including cutting of reinforcement as required to facilitate demolition and disposing of debris outside MD land complete all as specified and as directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water, etc., and disposing of debris outside MD land complete all as specified and as directed.
Material and labour for Pre-cast cement concrete block masonry with grade ‘C’ solid blocks exceeding 10 cm in width, having minimum compressive strength of 50 Kg / Sq cm as per IS 2185 (Part- I) 2005 and set in CM 1:6 complete all as specified and as directed.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) area of opening exceeding 1.5 Sq m but not exceeding 4 sq m each, complete all as specified and as directed.
Excavation in trenches, in hard / dense soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and getting out complete all as specified and as directed.
Returning, filling in (using soils), including spreading, leveling, watering and well ramming, soil in layers not exceeding 25 cm complete all as specified and as directed
Removing excavated surplus soil to a distance exceeding 50 M but not exceeding 100 M and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed
Supply and fix, double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty, fixed complete all as specified and as directed.
Supply and fix, Pressed steel door frame of size 105 x 60 mm using 1.25 mm thick sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified and as directed.
Material and labour for Plain Cement Concrete (1:3:6) type C0, using 12.5 mm graded stone aggregate as in filling the Chowkats/frames complete all as specified and as directed.
Supply and fix Factory made flush door shutters, 35 mm thick, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
Supply and fix 100 mm long Mild steel butt hinges medium weight cold rolled mild steel by welding to existing frame including taking down old hinges all as specified and as directed.
Supply and fix Aluminium anodized barrel tower bolts of extruded section, 150 mm long all as specified and as directed.
Supply and fix 150 mm long, Aluminium extruded alloy anodized handles, cast type complete all as specified and as directed.
Supply and fix Aluminium alloy, anodized, sliding door bolt with hasp, staple bolt type and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections 300 mm long all as specified and as directed.
Supply and fix floor door stoppers of rubber and aluminium alloy, powder coated, of 100 mm size complete all as specified and as directed.
Preparation of old plastered wall surfaces and applying one coat of oil bound distemper and matching the surfaces with adjacent surfaces, complete all as specified and as directed.
Material and labour, for Rendering 10 mm thick on brick or concrete surfaces in cement mortar (1:6) and finishing the surfaces even and smooth without using extra cement, preparing new plastered wall surfaces of any description not otherwise described and applying two coats of oil bound distemper over a coat of water based wall primer over and including 1 mm thick wall care putty, complete all as specified and as directed. Note : Quoted rate shall deemed to include for cost of wall care putty.
Material and labour, for Venetian blinds, vertical type, 100 mm wide with polyester fabric of approved colour and pattern with aluminium fittings, and top rail and nylon buttons / loops etc., fixed cuttings and alteration if necessary wherever AC/Coolers exists including dismantling the old unserviceable venetian blinds complete all as specified and as directed. (Price shall not be less than ` 125/- per square feet)
Material and labour, joint free non-skid Ceramic coloured tiles 7 to 8 mm thick (Grade B-II a), area of each tile exceeding 0.11 sq m but not exceeding 0.18 sq m, as in flooring, set and pointed in white or coloured cement to match colour of tiles over and including 15 mm thick screed bed in CM (1:4) complete all as specified and as directed.
Material and labour, joint free non-skid Ceramic coloured tiles 7 to 8 mm thick (Grade B-II a), area of each tile exceeding 0.11 sq m but not exceeding 0.18 sq m, as in vertical surfaces viz, skirting / dado etc., set and pointed in white or coloured cement to match colour of tiles over and including 10 mm thick screed bed in CM (1:3) complete all as specified and as directed.
Preparation of new or previously untreated wooden surfaces of any description not other wise described over 10 cm width or girth, applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Supply and fix powder Coated aluminium frames and shutters (minimum thickness of powder coating 50 microns) and fabricating of doors, windows, ventilators and fixed partitions with one or more rebates including necessary joining cleat, glazing clips, rubber packing, snap bending crews etc. complete all as specified and as directed. Note :- i) For payment purpose weight of aluminium section shall be measured and paid, ii) Cost of aluminium mongery. lock, rubber packing, rollers for sliding shall be deemed to include in the quoted rate, iii) Sheet glass and wire gauge shall be measured and paid for separately under respective items.
Supply and fix, stainless steel wire cloth 0.36 mm nominal dia of wire, and of average width of aperture 1.4 mm, fixed with stainless steel wire staples / wooden beading complete all as specified and as directed.
Supply and fix Plain Sheet glass 4 mm thick, ordinary quality and glazing with oil putty in square, exceeding 0.5 sq. m in each pane all as specified and as directed.
Supply and fix Plain Sheet glass 12 mm thick, ordinary quality and glazing with oil putty in square, exceeding 0.5 sq. m in each pane all as specified and as directed.
Supply and fix powder Coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified complete all as specified and as directed. Note :- Sheet glass and wire gauge shall be measured and paid for separately under respective items.
Supply, laying and connecting, XLPE insulated cable, 1100 V grade, heavy duty, PVC screened, bedded galvanized steel strip/wire armoured, aluminium conductor of cross sectional area 50 Sq mm 3.5 core with cable protection works (as applicable) laid in trenches/ ducts/ fixed on pole/ wall, including necessary lugs, jointing and testing complete all as specified and as directed. Note : Cable protection works shall be measured and paid for separately under respective items.
Supply and spreading river sand including watering and consolidation complete all as specified and as directed by Engineer-in-charge. Note : Punned thickness shall be considered for payment.
Material and labour for laying of burnt bricks sub class `B’ bricks of size 230 x 115 x 75 mm, laid in trenches for cable protection all as directed and specified
Supply and lay, galvanized iron tubing, light grade, 50 mm dia as in trenches / on wall using GI bend, other fittings etc for protection of cables, complete all as specified and directed by Engineer-in-charge.
Material and labour for concealed Point wiring with PVC insulated unsheathed, multi stranded copper conductor FRLS cable of size 1.5 sq.mm, 1100 grade, with PVC insulated unsheathed multi stranded copper conductor cable of size 1.5 sq.mm for earth continuity wire, drawn into and including non metallic rigid PVC conduit of suitable size, medium grade ISI marked including metal flush boxes of suitable size, modular white cover plate with support frame for mounting switches/ sockets etc fixed on walls/ roof surface concealed in walls including all necessary wall cutting and making good disturbed surface, for One light / fan / bell point controlled by one, one way switch 5/6 Amps complete all as specified and as directed. Note : The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement and making the disturbed surfaces to match with the existing surfaces.
All per Serial Item No 34 here-in-above, but suitable for 3-pin, socket outlet 5 Amps, fixed on independent board.
All per Serial Item No 34 here-in-above, but suitable for 3-pin, socket outlet 5 Amps, fixed on same board.
Material and labour for concealed Point wiring with PVC insulated unsheathed, multi stranded copper conductor FRLS cable of size 2.5 sq.mm, 1100 grade, with PVC insulated unsheathed multi stranded copper conductor cable of size 2.5 sq.mm for earth continuity wire, drawn into and including non metallic rigid PVC conduit of suitable size, medium grade ISI marked including metal flush boxes of suitable size, modular white cover plate with support frame for mounting switches/ sockets etc fixed on walls/ roof surface concealed in walls including all necessary wall cutting and making good disturbed surface, for switch socket outlet of 3 pin 15/16 Amps on independent board with required modules, complete all as specified and as directed. Note : The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement and making the disturbed surfaces to match with the existing surfaces.
Supply and fix Modular Switch, One module, One way, 5/6 Amps, 240 Volts all as specified and as directed.
Supply and fix Modular Switch, One module, One way, 16 Amps, 240 Volts all as specified and as directed.
Supply and fix, Modular bell push switch, one module, single pole, 230 volts 5/6 Amps capacity all as specified
Supply and fix, Modular socket outlet, 5/6 Amps 5 pin, 240 V, 2 Module, complete all as specified and directed.
Supply and fix, Modular socket outlet, 6/16 Amps, 240 V, 2 Module, complete all as specified and directed.
Supply and fix, modular call bell, multi music type, working on 230 volts, single phase complete all as specified and as directed.
Supply and fix, PVC Ceiling rose, surface type, Bakelite, 65 x 50 mm ISI marked with three terminals all as specified and as directed.
Supply and fix, Modular fan Regulator,120 W, electronic stepped type, 230 Volts 2 module, complete all as specified and as directed.
Supply and fix, Ceiling fan BEE 5 star rated complete 1200mm sweep, energy efficient suitable to function on 230V, single phase, AC supply, white colour, with down rod 300mm long, capacitor 2.5 mfd, canopies, nuts, bolts and washers and connecting with and including provision of 3 core 1.5 sq.mm PVC sheathed flexible copper conductor from ceiling, writing MES number on ceiling fan motor complete all as specified and directed. MAKE:- Auro Plus of Crompton Greaves or techno-commercially equivalent model in BAJAJ / HAVELLS / USHA
Supply and fix, exhaust fan, 230/240 Volt, 50 Hz, single phase, AC supply, 300 mm sweep, 900 rpm, with louvers complete with metal body powder coated with protective steel bird guard on wall of building with and including provision of 3 core 1.5 Sq.mm flexible cable from ceiling rose to exhaust fan, including making hole in wall for fixing exhaust fan and making good the disturbed surfaces of wall matching with adjacent surfaces, including writing MES number on exhaust fan motor using synthetic enamel paint of approved tint, complete all as specified and directed. MAKE:- Model : Turbo Force SP of Havells or techno-commercially equivalent model in Almonaro / Bajaj.
Supply and fix, Air Circulators wall mounted fan, 230/240 Volt, 50 Hz, single phase, AC supply, 450 mm sweep, including provision of 3 core 1.5 Sq.mm flexible cable from ceiling rose, complete all as specified and directed. MAKE:- Model : Turbo Force of Havells or techno-commercially equivalent model in Almonaro / Bajaj.
Supply and fix, DB TPN 4 way (Vertical type), double door, with Sheet metal enclosure, for using MCCBs as incomer and outgoing circuits, flush mounted, prewired, 415 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, Din bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCCB/MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
Supply and fix, MCB DB SPN 12 way (Horizontal), double door, with Sheet metal enclosure, flush mounted, prewired, 415 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
Supply and fix, MCCB, TPN, 415 volts, 63 amps, 16 kA breaking capacity, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix, MCB SP, 240 volts, 3 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix, MCB SP, 240 volts, 6 to 32 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix, MCB SP, 240 volts, 40 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix, MCB SPN, 240 volts, 40 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix, concealed conduit in walls/ ceilings / floors, with rigid non-metallic PVC conduit 20 mm dia, including necessary accessories i.e., T's, bends, elbows, reducers, adapter, reducers, saddles, couplers, lock nuts, pipe hooks, etc., complete all as specified and as directed. NOTE: - i) Cost of Cutting and chases in wall for concealed wiring and making good disturbed surfaces to match with adjoining surfaces shall deemed to be included in quoted rate. ii) Junction boxes will be measured and paid for separately under respective item.
Supply and fix, PVC junction boxes concealed (1 to 4 ways), with modular frame cover suitable for connecting to 20 mm dia PVC conduit, complete all as specified and as directed. NOTE: - Cost of Cutting / making in holes for concealing and making good disturbed surfaces to match with adjoining surfaces shall deemed to be included in quoted rate.
Supply and lay, LAN multi core cable, category-6 (4-pair unshielded twisted pair cable) with high density polyethylene insulation, paired, fire retardant as IS / IEC 11801, drawn through concealed non metallic rigid PVC conduit complete all as specified and directed.
Supply and lay, telephone cable, 5-pair, with high density polyethelene insulated, solid annealed high conductivity bare copper with dia 0.5 mm, paired, polyester taped and sheathed conforming to ITD Specifications, drawn through concealed non metallic rigid PVC conduit complete all as specified and directed.
Supply and fixing, telephone jack with shutter, RJ 11, including modular cover plate with frame, complete all as specified and directed. Anchor Pental make Cat Part No 65610 or techno commercial equivalent specified here-in-after.
Taking down existing sub main wiring, and Supply and fixing, Concealed, Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, stranded copper conductor cable, 2 runs of single core 4 Sq mm and one run of earth continuity conductor 1 run of 4 Sq mm to be drawn through and including 25 mm dia PVC conduit medium Grade fixed in walls / roof / floors complete all as specified and as directed. NOTE: - i) TWO runs of 04 sq.mm cable, ONE run of 4 sq mm earth wire and one run of PVC conduit shall be measured as one length. ii) Cost of Cutting and chases in wall for concealed wiring shall deemed to be included in quoted rate.
Supply and fixing, Concealed, Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, stranded copper conductor cable, 2 runs of single core 6 Sq mm and one run of earth continuity conductor 1 run of 6 Sq mm to be drawn through and including 25 mm dia PVC conduit medium Grade fixed in walls / roof / floors complete all as specified and as directed. NOTE: - i) TWO runs of 06 sq.mm cable, ONE run of 6 sq mm earth wire and one run of PVC conduit shall be measured as one length. ii) Cost of Cutting and chases in wall for concealed wiring shall deemed to be included in quoted rate.
Taking down existing recessed CFL light fitting, Supply and fixing 42 W, LED ceiling mounted recessed full lit luminaire with glare free uniform illumination, down lighter fitting, efficient luminaire, 2'x2', Ultra modern designed architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for ceiling, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 120 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH , 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable, including lamps complete all as specified and directed. MAKE:- Cat No.VENUSNEOHE2X2PLR18-42WLED865MOD of Havells or techno-commercially equivalent model specified here-in-after, complete with all accessories pre-wired, all as specified and as directed.,
Supply and fixing high wall Split type Air conditioner of 2 Ton capacity, BEE 5 star rating, inverter, with built in air ionizer and plasma filter for better air quality complete with indoor unit & outdoor unit, cordless remote control unit complete with condensing unit, room unit suitable for operation of refrigeration gas including, refrigeration copper piping of required length as per manufacturers instructions, standard length of 7.5 m with Nitro lite Rutile sleeve insulation along with PVC water drain pipe of 25 mm dia of 5 m long, R-22 gas filled, indoor noise level (low) 44 db, indoor noise level (medium) 48 db, indoor noise level (High) 50 db, power consumption of 1665 W an operating voltage 220 - 240 V AC, connecting with and including 4 core 2.5 Sq mm flexible wire etc., all as specified and as directed. Notes :- (i) The condensing unit shall be mounted on the roof slab / side wall / on the ground including making hole in the wall /slab / ground as necessary all as specified. (ii) Room unit shall be placed in the room against the outdoor unit. (iii) Proper drainage arrangement shall be made from room unit to facilitate easy flowing of water outside the room.
Material and labour for earthing complete with Galvanized Iron earth plate electrode 600 mm x 600 mm x 6.3 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earth strip of 25 x 4 mm by means of bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 50 mm bore (light grade) connected to earthing test point all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 40 mm bore light grade GI pipe for watering funnel wire mesh, PCC chamber in cement concrete (1:3:6), type C1 , manhole cover with RCC (1:2:4), type B-1, reinforced with 8 mm dia MS round bars @ 75 mm c/c both ways for cover and MS frame etc., and achieve resistance below 2 Ohm complete all as specified and as directed NOTES :- (i) The quoted rate deemed to include earth strip and protection pipe up to 7.5 metre from earth plate / earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Material and labour GI Earth Strip 25 mm X 4 mm buried in ground / fixed on wall / floor as per site requirement for purpose of Beyond 7.5 meter measurement earthing strip complete all as specified and directed by Engineer-in-charge.
Supply and fix, Voltage stabilizer, wall mounted, naturally cooled, indoor type, Automatic Boost / Buck for low and high voltage correction equipped with electronic circuit, relays of single phase 50Hz AC supply, complete designed for input voltage of 170 to 250 Volts and output voltage stabilized at 230Volts with an accuracy of ± 2.5%, TDR to 3min ± 20% seconds, of 5 KVA capacity, complete all as specified and directed. MAKE:- V-GUARD / K-LINE / VOLINA / APLAB / MICROTECH / AE
Supply and fix sheet metal enclosure, SP with metal plug and socket, 20 Amps, 250 Volts, including provision of one MCB SP 20 Amps, 'C' Curve type,230 Volts AC, 50 Hz, 10 kA, breaking capacity, complete all as specified and as directed.
Supply, install and commissioning of Mini RO water purifier, 7 litres capacity with RO, UV & UF, fixing to wall properly with suitable size of brackets / nuts & bolts with complete, including providing water connection from existing water tap complete all as directed.
RASHMI BUILDERS
M/S Suresh Raju
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .