Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹27.7 L+₹80,480.09 (2.99%)Rejected-Finance 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹31.6 L+₹4.7 L (17.6%)Rejected-Finance 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance In order but L3 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
17 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(U) E/M Meerut Cantt
GE(U) E/M Meerut Cantt
REPAIR/REPLACEMENT OF OLD VINTAGE ELECTRIC FITTING AND CONNECTED ITEMS AT CERTAIN 2 ARMY HQ SIG REGT, 2 COY UB AREA SIG COY AND GE(U) E/M, 581 SUB GP AND CRTA DABATHWA UNDER AGE E/M (ES) AT GE(U) E/M MEERUT CANTT
2021_MES_496662_1
8398/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE(U) E/M Meerut Cantt
₹70,000
Yes
22 Feb 2022
22 Dec 2021
19 Jan 2022
22 Dec 2021
17 Jan 2022
5 Jan 2022
22 Dec 2021 - 30 Dec 2021
90 days
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit for unserviceable materials (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc to match with the existing complete all as specified.B23
Taking down carefully unserciceable switch piano, bell push, socket, fan regulator, lamp holder, ceiling rose, junction box, metal flush boxes of any type and description all as specified.
Taking down carefully unserciceableMCB SP/SPN, Isolator of any rating and description/size all as specified.
Taking down carefully unserciceable T/L fitting, panel light fitting, garden light, security light, post top lantern, bulk head fitting any wattage and description all as specified.
M&L (except Conduit and Conduit fittings) point wiring controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed cables in existing concealed/surface PVC /steel conduit and PVC fittings but including Zinc Coated pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed and connecting to earth dolly and brass screws, washers etc. complete all as specified for follwing :- (Note:- The rate quoted against this item shall be deemed included for making good disturbed surfaces to match with the existing.)
One light point controlled by one 5 Amp one way switch
One ceiling fan/ exhaust fan point controlled by one 5 Amp one way switch
One buzzer /bell point controlled by one 5 Amp one way switch
One 3 Pin , 6 Amp socket point on independent board.
One 3 Pin , 6 Amp socket point on same board with other switch
all as item no 5 above but with 4 sqmm cable for 15 Amp switch socket out let point on independent board including 4 sqmm PVC insulated un sheathed cable multi stranded with copper conductor earthing continuity conductor all as specified and directed.
M&L point wiring using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed cables drawn through and including PVC casing & caping fixed on surface of wall/ ceiling including Zinc Coated pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed and connecting to earth dolly and brass screws, washers etc. complete all as specified for follwing :- (Note:- The rate quoted against this item shall be deemed included for making good disturbed surfaces to match with the existing.)
One light point controlled by one 5 Amp one way switch
One ceiling fan/ exhaust fan point controlled by one 5 Amp one way switch
One buzzer /bell point controlled by one 5 Amp one way switch
One 3 Pin , 6 Amp socket point on independent board.
One 3 Pin , 6 Amp socket point on same board with other switch
All as item no 7 above but with 4 sqmm cable for 15 Amp switch socket out let point on independent board including 4 sqmm PVC insulated un sheathed cable multi stranded with copper conductor earthing continuity conductor all as specified and directed.
M&L point wiring using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed (FRLS) cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed (FRLS) earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified for the followings:- Note:- The rate quoted against this item shall be deemed included for cutting chases for concealed conduit and boxes etc including making good disturbed surfaces to match with the existing.)
One light point controlled by one 5 Amp one way switch
One ceiling fan/ exhaust fan point controlled by one 5 Amp one way switch
One buzzer /bell point controlled by one 5 Amp one way switch
One 3 Pin , 6 Amp socket point on independent board.
One 3 Pin , 6 Amp socket point on same board with other switch
All as item no 9 above but with 4 sqmm cable for 15 Amp switch socket out let point on independent board including 4 sqmm PVC insulated un sheathed cable multi stranded with copper conductor earthing continuity conductor all as specified and directed.
Supply & fixing only polycarbonate Switch piano flush type,SP, 6 Amps, one way complete all as specified.
S&F polycarbonate bell push flush type,SP, 6 Amps, one way complete all as specified.
S&F Polycarbonate Switch piano flush type, single pole , 16 Amps, one way complete all as specified.
S&F Polycarbonate socket out let 2 in 1, 3 pin , 6 Amps flush type controlled by one switch complete all as specified.
S&F Socket outlet 2 in 1 ,3 pin, 6 & 16 amp, flush type ( ISI) marked complete all as specified.
S& F ceiling fan regulator electronic modular socket type , rotary 0 to 4 steps , hum free, 100 watts , 230 Volts, ISI marked complete all as specified .
S&F Lamp holder, polycarbonate type with back plate complete all as specified and directed.
M&L polycarbonate insulated body ceiling rose 6A, 65x50mm with three terminals, ISI maked fixed complete all as specified.
Supply and fixing rigid non metallic PVC conduit 25 mm dia including fittings like bend, tee, elbow, reducer, socket, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles pipe hooksetc complete all as specified and directed.
Supply and fixing rigid non metallic PVC junction boxes (1 to 4 way) complete all as specified and directed.
Supply and fix Modular switch 1 way 6A, 1 moduleall as specified
Supply and fix Modular switch 1 way 16A, 1 module all as specified.
Supply and fix Modular fan regulator, 120 w-2 module all as specified.
Supply and fix Modular Socket , 6 A, 2/3 Pin combined 2 module all as specified.
Supply and fix Modular Socket , 6 A/16A-6 Pin combined 2 module all as specified.
Supply and fix Bell ding dong all as specified.
Supply and fix Buzzer all as specified.
Supply and fixbell push Modular all as specified.
Supply and fix Modular metal flush box 1/2 module for mounting modular type switchs/sockets all as specified
Supply and fix Modular metal flush box 3 module for mounting modular type switchs/sockets all as specified
Supply and fix Modular metal flush box 4 module for mounting modular type switchs/sockets all as specified
Supply and fix Modular metal flush box 6 module for mounting modular type switchs/sockets all as specified
Supply and fix Modular metal flush box 8 module for mounting modular type switchs/sockets all as specified
Supply and fix Modular white cover plate with frame, 1 Module all as specified
Supply and fix Modular white cover plate with frame, 2 Module all as specified
Supply and fix Modular white cover plate with frame, 3 Module all as specified
Supply and fix Modular white cover plate with frame, 4 Module all as specified
Supply and fix Modular white cover plate with frame, 6 Module all as specified
Supply and fix Modular white cover plate with frame, 8 Module all as specified
S&F 20watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorative alumiinium extruded T5 LED battens , Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 4' long, and making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
S&F 10watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorative alumiinium extruded T5 LED battens , Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 2' long, and making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
S&F Light emitting Diode (LED) recess mounting panel ( edgelit type) 2'x2' - 36 watts, 6000k,with separate electronic driver with extruded aluminium housing and milky anti glare diffuser complete including cutting holes of required size in false ceiling and making good disturbed surfaces complete all as specified.
S&F Light emitting Diode (LED) recess mounting panel ( edgelit type) 1'x1' - 18 watts, with extruded aluminium housing and milky anti glare diffuser complete including cutting holes of required size in false ceiling and making good disturbed surfaces complete all as specified.
S&F 12 W, down light fitting consisting PDC aluminium housing with poly carbonate milky diffuser, SMD light emitting diaode (LED) and heat sink integrated with housing complete including mking good disturbed surfaces complete all l as specified.
S&F Energy saving & environment friendly LED street light fitting made out of pressure die cast anodised aluminium housing 48 Watt to achieve B1 class road illumination as per IS: 1944 and as per national lighting code using each LED >1 watt and <3 watt , LED chip efficiency >= 135 Lumens/Watt, CRI>70, CCT 5000K to 6500K with LED life span at 70% of light output >50000 hours with suitable driver 140V to 270V universal type, with bult in surge protection >5KV, 50 Hz +/- 3% , pf 0.95, THD <10% with system efficiency >85 lumens/ Watt and power efficiency >=90% and overall IP 65 or better , driver and luminaire shall comply LM-79/IS:16106 and with and including street light bracket made out of 25mm dia or higher GI pipe light grade, 1.50metre long bend to shape 120 degree angle with suitable adaptor and fixed to pole / wall/ ceiling by two Nos MS clamp made out of flat iron size 40x6mm with nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by EIC.
S&F LED 40 Watt decorative post top lantern made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP65 prrotection , resistance to impact and corrosion , glare free and better uniformity including necessary PCC foundation and nuts/bolts for fixing of light fitting etc all as specified and directed by EIC.
S&F LED 10 Watt decorative garden light inverted pyramid tripod type LED bollard wiyh soft 360 degree distribution , IP65 prrotection , resistance to impact and corrosion , glare free and better uniformity including necessary PCC foundation and nuts/bolts for fixing of light fitting etc all as specified and directed by EIC.
S&F LED 50 Watt flood light pressure die cast housing with IP 65 protection, efficient high out put LED for better distribution applicable for monument lighting, area lighting and security lighting including necessary brackets and nuts/bolts for fixing lightt fitting on wall /Pole etc all as specified and directed by EIC.
S&F LED 80 Watt flood light pressure die cast housing with IP 65 protection, efficient high out put LED for better distribution applicable for monument lighting, area lighting and security lighting including necessary brackets and nuts/bolts for fixing lightt fitting on wall /Pole etc all as specified and directed by EIC.
Supply & fixing in repair Light Emitting Diode (LED) bulb 12 watts , retrofit type,240 volts complete all as specified and directed.
M&L in repairs for submain wiring comprising two single core ,4 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC concealed conduit and conduit fittings , medium grade not less 25mm dia with 4 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. ( Note :- (a) Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) (b) One metre of conduit alongwith 2x6 sqmm wire and 1x4 sqmm earth wite shall be measured as one unit length)
M&L in repairs for submain wiring comprising two single core ,6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC concealed conduit and conduit fittings , medium grade not less 25mm dia with 6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. ( Note :- (a) Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) (b) One metre of conduit alongwith 2x6 sqmm wire and 1x4 sqmm earth wite shall be measured as one unit length)
M&L in repairs for submain wiring comprising two single core ,10 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC concealed conduit and conduit fittings , medium grade not less 25mm dia with 10 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. ( Note :- (a) Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) (b) One metre of conduit alongwith 2x6 sqmm wire and 1x4 sqmm earth wite shall be measured as one unit length)
M&L in repairs for submain wiring comprising three single core ,6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC concealed conduit and conduit fittings , medium grade not less 25mm dia with 6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. ( Note :- (a) Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) (b) One metre of conduit alongwith 2x6 sqmm wire and 1x4 sqmm earth wite shall be measured as one unit length)
Taking down unserviceable cable and Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 10 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor (including excavation)or fixed naked with walls / on poles/ in ducts /in pipes etc
S&F Miniature circuit breakers AC, SP, 6 to 32 Amps, 240 Volts , 10 KA, 'C' curve rating and making connections with suitable copper lugs complete all as specified and directed
S&F Miniature circuit breakers AC, SP,40 Amps, 240 Volts , 10 KA, 'C' curve rating and making connections with suitable copper lugs complete all as specified and directed
S&F Miniature circuit breakers AC, SPN, 63 Amps, 240 Volts , 10 KA, 'C' curve ratingand making connections with suitable copper lugs complete all as specified and directed .
S&F Miniature circuit breakers AC, TPN, 100 Amps, 415 Volts , 10 KA, 'C' curve ratingand making connections with suitable copper lugs complete all as specified and directed .
Taking down unserviceable Sheet Metal Enclosure and S & F epoxy powder coated distribution box, Single pole & neutral 8 way with 200 amps capacity , 240 Volts,IP 43, double door for MCB , grouted flush to walls including making good disturbed surafces to match with the existing complete all as specified and directed.
Taking down unserviceable Sheet Metal Enclosure and S & F epoxy powder coated distribution box, Single pole & neutral 4 way with 200 amps capacity , 240 Volts,IP 43, double door for MCB , grouted flush to walls including making good disturbed surafces to match with the existing complete all as specified and directed.
Taking down unserviceable Sheet Metal Enclosure and S & F epoxy powder coated distribution box, Single pole & neutral 12 way with 200 amps capacity , 240 Volts,IP 43, double door for MCB , grouted flush to walls including making good disturbed surafces to match with the existing complete all as specified and directed.
Taking down unserviceable Sheet Metal Enclosure and S & F epoxy powder coated distribution box, TPN 4 way 415Volt,IP 43, double door for MCB/ isolator , grouted flush to walls including making good disturbed surafces to match with the existing complete all as specified and directed.
S&F in repairs SPN Sheet metal enlosures (factory made) with 10KA, 'B' curve Single pole MCB rated 20 amps with socket plug top 2 pin and earth plug complete all as specified including making connection complete all as specified.
Taking down carefully after disconnecting electrical/water supply connections and transporting to the work shop for carry out the servicing / over hauling of the storage type electric water heaters (Geysers) of storage capacity 25 / 50 litres of any make / type by cleaing the inner surface of the tank / heating element with chemical to remove the scaling / rust & reassembling the same after replacing burnt out parts and refixing on its original position including testing complete all as directed.
Supply & replace heating element of 1/1.5 KW ratings as required at site including rubber washer/packing completeall as specified.
Supply & replace heating element of 2 KW ratings as required at site including rubber washer/packing completeall as specified.
Supply & replace base assembly complete i.e., "SIPHON SET" inlet, outlet, thermostat pockets with drain plugs & screws for fixing the element inclusive of clamps for holding the element with nuts & boltscompleteall as specified.
Supply & replace thermostat stem type suitable for geysers 25 / 50 litres all as specified and directed
Supply & replace cut off for geyser as per sample suitable for geysers 25 / 50 litres complete all as specified.
Supply & replace 15 mm dia chromium plated copper tube with two brass adopters 18" long and fixing in position for hot water outlet connections all as specified and directed.
Supply & replace PVC connections with two brass adaptors 18" long & fixing in position for cold water inlet connections all as specified.
Supply & fix in replacement stop cock brass 15mm dia and connecting up in position all as directed.
Repairs to leaking copper inner water tank by soldering/brazing including replacement of nut, bolts etc complete all as specified.
Repairs to siphon set by soldering/brazing including replacement of bolts/nuts/washers/rubber gaskets etc complete all as directed.
Supply & fix in replacement Gun metal Non-Return valve 15mm dia complete all as specified.
Supply & replace indicator lamp rectangular / round type suitable for 25 / 50 litres geysers.
Supply and fix in repair pressure release valve 15mm dia complete all as specified.
Supply and replace unserviceable corroded bottom plate of geyser with PVC two portion plate complete as specified.
Supply & fix GI Pipe medium grade 15mm dia on wall ceiling for geyser inlet including GI specials clamps etc & wherever necessary making of holes in the walls incl making good disturbed surfaces complete all as directed.
Material & labour for painting of storage type water heater any capacity (25/50 litres) after preparation of surface and applying two coats of synthetic enamel paint, white externally complete all as specified.
Taking down the defective Ceiling fan of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete. Note:- Spare parts shall be paid under respective items of BOQ.
M&L for Re-winding of ceiling fan any sweep taken down vide item No 82 with same guage supper enameled copper wire including insulation, varnishing, greasing etc and testing for RPMand other all as specified and directed.
M&L for Painting of ceiling fan any sweep taking down vide item No 82 by applying one coat of synthetic enamel paint after preparation of surface including writing MES number complete all as specified
Supply only ball bearings for exhaust/ceiling fan of any sweep.
Supply only GUN METAL BUSH for exhaust / ceiling fan of any sweep.
Supply and fixing fan condenser of 2.5 Mfd rating
Supply and fixing fan condenser of 4 to 6 Mfd rating
S&F rubber reel, nut bolts, washer, split pin of ceiling fan of any size complete set by dismantling existing u/s ceiling fan all as specified and directed.
S & F Fan connector suitable for wire connection all as specified and directed.
Supply & Fix ceiling fan down rod of MS pipe 15mm bore of length as per site measurement including cutting/threading making tide for fixing providing check nuts wachers etc complete.
Taking down the u/s Exhaust fan of 300 MM / 380 MM sweep, any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:- (a) Servicing/overhauling the exhuast fan by thoroughly clelaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the resistance value. Note:- Spare parts replaced shall be measured and paid separately
M&L for Re-winding of exhaust fan 300 MM / 380 MM sweep, any make, taking down vide item No 92 with same guage supper enameled copper wire to maintain speed at load.
M&L for Painting of exhaust fan 300 MM / 380 MM sweep, any make, taking down vide item No 92 by applying one coats of synthetic enamel paint after preparation of surface complete.
Supply only ball bearings for exhaust fan of any sweep.
Supply only GUN METAL BUSH for exhaust fan of any sweep.
Taking down the u/s air circulator wall mounted 300 to 450 mm sweep any make single phase 230 Volts, 50 Hz AC after disconnecting electrical and mechanically and transporting to the work shop dismantling examine and carry out the repairs as required and broght back to site re-fixing testing in all respect for smooth running and comprising of the following. (a) Servicing/overhauling the Air circulator industrial type of thoroughtly cleaning the bearing, shaft, stator, rotor and applying the lubricant/grease to the bearing including applying one coat of super enameled varnish over the winding to improve the resistance value.
Re-winding of Air circulator 300 to 450 MM sweep, any make, taking down vide item No 97 with same guage supper enameled copper wire to maintain speed at load.
Taking down old u/s wall mounted fan and Supply and Fix new 400 mm sweep copper wound wall mounted fan including neessary accessories required to fix the fan on wall and making good surfaces after fixing all as directed by Engineer-in-Charge.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level connected to GI earth lead wire 4 mm dia by means of nuts and bolts, check nuts and washers of galvanised iron or steel, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, GI wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments, 20 dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 40mm thick precast RCC 1:2:4 type B-1, duly reinforced with 8mm dia TMT bars @ 150mm C/c and 6mm dia bars in lifting handles and MS angle frame of angle iron 40x40x5 mm thick, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Jain Traders
Gupta Automobiles
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .