Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.9 CrAccepted-AOC 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | ₹4.9 Cr | 1 | Accepted-AOC being L1 |
| 2 | 2₹4.9 Cr+₹6.2 L (1.27%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹4.9 Cr+₹6.2 L (1.27%) | 2 | Rejected-Finance being not L1 |
| 3 | 3₹5.0 Cr+₹9.1 L (1.86%)Rejected-Finance | ₹5.0 Cr+₹9.1 L (1.86%) | 3 | Rejected-Finance being not L1 |
| 4 | 4₹5.0 Cr+₹9.3 L (1.91%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹5.0 Cr+₹9.3 L (1.91%) | 4 | Rejected-Finance being not L1 |
| 5 | 5₹5.2 Cr+₹34.4 L (7.05%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹5.2 Cr+₹34.4 L (7.05%) | 5 | Rejected-Finance being not L1 |
Tender Value
₹6.8 Cr
EMD Value
₹6.7 L
Closing Date
15 Feb 2021, 6:00 pmClosed
CHIEF ENGINEER
HQ CEJZ JAIPUR
AUGMENTATION OF ELECTRIC SUPPLY NETWORK SYSTEM FOR DEPOT AREA AT BHARATPUR
2020_MES_372600_2
CEJZ/NIT/BPR-03 OF 2020-21
Open Tender
Civil Works
Lump-sum
365 days
BHARATPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE BHARATPUR
₹6.7 L
Yes
17 Mar 2021
30 Jan 2021
20 Feb 2021
30 Jan 2021
15 Feb 2021
10 Feb 2021
Amount
Lump sum price worked out by the Contractor for "Building work” as listed in Schedule ‘A’ Part I **Above / Below the lump sum price inserted by the MES in Schedule ‘A’ Part-I
Lump sum price worked out by contractor for "Internal water supply" as listed in Schedule `A' Part-II*Above/below the lump sum price inserted by the MES in Schedule `A' Part-II
Lump sum price worked out by the Contractor for "Internal Electrification" as listed in Schedule ‘A’ Part-III **Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-III
Lump sum price worked out by the Contractor for "External Electrification" as listed in Schedule ‘A’ Part-IV **Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-IV
Lump sum price worked out by the Contractor for " Security Fencing" as listed in Schedule ‘A’ Part-V **Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-V
Lump sum price worked out by the Contractor for " Excavation and Earth Work" as listed in Schedule ‘A’ Part-VI **Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-VI
Schedule `A' Part-VII (rate against Srl No.8 to 49 shall be quoted by the Contractor)
Supply & Fixing of ceiling fan 1200 mm sweep, suitable for SP 230/250 V 50 Hz AC supply with down rod and connecting up with 3 runs of 1.5sqmm, single core PVC insulated unsheathed, FRLS cable with mutistranded copper conductors IS 694 marked, from ceiling rose to fan. Make Havells, Cat No ES-5 Star (Energy saving fan) or equivalent make as given in Appendix 'B'.
Supply & fixing exhaust fan of 250mm sweep suitable for SP 230/250V 50 Hz AC supply, protective bird guard is provided, robost construction complete including fixing/grouting of frame in wal and cutting opening complete and connecting with and including 3 nos 1.5 sqmm single core, PVC insulated unsheathed FRLS cable with multistandrad copper conductors from ceiling rose to fan. .
Supply & fixing exhaust fan of 450mm sweep suitable for SP 230/250V 50 Hz AC supply, protective bird guard is provided, robost construction complete including fixing/grouting of frame in wal and cutting opening complete and connecting with and including 3 nos 1.5 sqmm single core, PVC insulated unsheathed FRLS cable with multistandrad copper conductors from ceiling rose to fan.
S & F MCB(C-curve) ISI Marked SP, 6 Amp,10 KA rupturing capacity, IS marked, fixing in DB complete all as specified and directed. Note (i) DB shall be measured and paid seperately. (ii) Make of the MCB should be the same as that of DB.
S & F MCB(C-curve) ISI Marked SP, 10 Amp,10 KA rupturing capacity, IS marked, fixing in DB complete all as specified and directed. Note (i) DB shall be measured and paid seperately. (ii) Make of the MCB should be the same as that of DB.
S & F MCB(C-curve) ISI Marked SP, 16 Amp,10 KA rupturing capacity, IS marked, fixing in DB complete all as specified and directed. Note (i) DB shall be measured and paid seperately. (ii) Make of the MCB should be the same as that of DB.
S & F MCB(C-curve) ISI Marked SPN, 25 Amp,10 KA rupturing capacity, IS marked, fixing in DB complete all as specified and directed. Note (i) DB shall be measured and paid seperately. (ii) Make of the MCB should be the same as that of DB.
Supply & Fixing wall mounted LED batten fitting, 18W LED 6000K, with LED rod 1x20watt, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete including copper cable 23/.0076 for electric connection for fitting from ceiling rose complete all as specified and directed.
Supply & Fixing LED bulb holder including LED bulb 1x05watt, complete all as specified and directed.
Supply & Fixing 45W LED security light fitting, 240 volts AC, 50 Hz of new generation energy saving & environmental friendly long life versatile pressure dia cast aluminium IP 66 roadway luminair with high power LEDs as light source and electronic driver, pre wired, complete with all necessary fittings including suitable dia bend shape GI pipe light grade of appx length 1.0 mtr length with clamp nut & bolts for fixing on wall etc complete all as specified and directed.
Supply, laying, testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes including aluminium lugs and suitable size brass glands complete of following sizes:- Note :- Earth work , sand cushioning and brick/ cable cover protection shall be measured and paid seperately under respective item of Schedules/BOQ.
(a) 25 sqmm 4 core
(b) 35 sqmm 3½ core
(c) 50 sqmm 3½ core
(d) 70 Sqmm 3½ core
(e) 95 sqmm 3½ core
(f) 120 sqmm 3½ core
(g) 150 sqmm 3½ core
(h) 400 Sqmm 3½ core
Supply, laying, testing and commissioning of cable XLPE insulated (Earthed), screened, PVC bedded, galvanized wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm laid in tranches/floor etc with suitable size glands and aluminium lugs complete all as specified and directed. 'Note :- Earth work , sand cushioning and brick/ cable cover protection shall be measured and paid seperately under respective item of Schedules/BOQ.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 sqmm to 185 sqmm complete all as specified and directed.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 sqmm to 185 sqmm complete all as specified and directed.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 sqmm to 185 sqmm complete all as specified and directed.
Supply, installation, testing & commissioning of transformer of capacity 100 KVA step down outdoor type copper wounded 11/0.433 KV (at no load) AC 3 phase 50HZ on secondary side double copper wound oil immersed naturally all air cooled (ONAN COOLED) with external cooling tubes /radiator , delta connected as on primary and star connected with natural brought on secondary) side and having tapping at (±) 2.5%,(±) 5% (±) 7.5% to be changed by hand operated OFF LOAD tap changing gear . The maximum temperature rise should not exceed 45 degree centigrade in oil and 50 degree centigrade in HV/ LV winding when measured by the resistance method after continuous full load run in ambient temperature the transformer shall confirming to IS 1180 Part-I:2014; Level-3 and including comprising of following accessories complete all as specified and as directed :-
(a) HV side Cable box with 03 Nos porcelain HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods and nuts, washers and cable glands suitable for reception of out 3 core 120 Sqmm cable, HT Cable 11000 Volts grade XLPE insulated heavy duty including gland complete. (b) 01 No cable end box on LV secondary side consisting of 05 Nos porcelain bushing (One No neutral earth, One No Neutral and Three No for phase connected bushing) with bushing rods and nuts washers and cable glands suitable for reception of out 3.5 core 120 Sqmm cable 2 runs, LT 1100 Volts grade XLPE insulated heavy duty including gland joint complete. (c) Oil conservator with filter type drain valve and oil level gauge. (d) Dehydrating breather with first filling of dehydrating agentV (e) Explosive vent. (f) Thermometer pocket including temperature gauge (g) Two earthing terminals on tank body to facilitate fixing of 32x6mm GI strips. (h) One No thermometer dial type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge: Max reading painted terminal. (i) Rating plate with terminal plate. (j) Oil level gauge. (k) Oil drain filter valve. (l) Oil filling hole on top cover with plug. (m) Air release valve/plug. (n) 4 Nos plain solid cast steel detachable rollers. (o) First fill of transformer oil conforming to relevant ISI and tested upto 60 KV dielectric strength. (p)Two Nos lifting hooks at side of transformer (q) 1No Breather duly filled with silicajel crystals capacity 500g Note : Providing platform for transformer of size 3.0x3.0x1.5m high from GL including excavation in trenches not less than 1 mtr, PCC 1:5:10 type E2 for foundation, brick work in CM 1:6, PCC 1:2:4 type B1 in coping, plaster 10mm thick in CM 1:6 on brick /concrete surfaces, PCC 1:4:8 type B1 sub base 75mm thick, PCC 1:2:4 type B1 100mm thick as in floor using extra cement returning filling in and removal on surplus soil, including 2 Nos ISMB 100mm channel painting with 2 coat aluminium paint over a coat of red oxide primer and 3 coats of white washing on plastered surfaces for fixing transformer including ramp of suitable size for mounting of transformer complete all as specified and directed. Unit rate quoted by the contractor for the above item shall be deemed to be included for this provision.
Supply, installation, testing & commissioning of transformer of capacity 315 KVA step down outdoor type copper wounded 11/0.433 KV (at no load) AC 3 phase 50HZ on secondary side double copper wound oil immersed naturally all air cooled (ONAN COOLED) with external cooling tubes /radiator , delta connected as on primary and star connected with natural brought on secondary) side and having tapping at (±) 2.5%,(±) 5% (±) 7.5% to be changed by hand operated OFF LOAD tap changing gear . The maximum temperature rise should not exceed 45 degree centigrade in oil and 50 degree centigrade in HV/ LV winding when measured by the resistance method after continuous full load run in ambient temperature the transformer shall confirming to IS 1180 Part-I:2014; Level-3 and including comprising of following accessories complete all as specified and as directed:-
(a) HV side Cable box with 03 Nos porcelain HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods and nuts washers and cable glands suitable for reception of out 3 core 120 Sqmm cable, HT Cable 11000 Volts grade XLPE insulated heavy duty including gland complete. (b) 01 No cable end box on LV secondary side consisting of 05 Nos porcelain bushing (One No neutral earth, One No Neutral and Three No for phase connected bushing) with bushing rods and nuts washers and cable glands suitable for reception of out 3.5 core 400 Sqmm cable 3 runs, LT 1100 Volts grade XLPE insulated heavy duty including gland joint complete. (c) Oil conservator with filter type drain valve and oil level gauge. (d) Dehydrating breather with first filling of dehydrating agent (e) Explosive vent. (f) Thermometer pocket including temperature gauge (g) Two earthing terminals on tank body to facilitate fixing of 32x6mm GI strips. (h) One No thermometer dial type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge: Max reading painted terminal. (i) Rating plate with terminal plate. (j) Oil level gauge. (k) Oil drain filter valve. (l) Oil filling hole on top cover with plug. (m) Air release valve/plug. (n) 4 Nos plain solid cast steel detachable rollers. (o) First fill of transformer oil conforming to relevant ISI and tested upto 60 KV dielectric strength. (p)Two Nos lifting hooks at side of transformer (q) 1No Breather duly filled with silicajel crystals capacity 500g Note : Providing platform for transformer of size 3.0x3.0x1.5m high from GL including excavation in trenches not less than 1 mtr, PCC 1:5:10 type E2 for foundation, brick work in CM 1:6, PCC 1:2:4 type B1 in coping, plaster 10mm thick in CM 1:6 on brick /concrete surfaces, PCC 1:4:8 type B1 sub base 75mm thick, PCC 1:2:4 type B1 100mm thick as in floor using extra cement returning filling in and removal on surplus soil, including 2 Nos ISMB 100mm channel painting with 2 coat aluminium paint over a coat of red oxide primer and 3 coats of white washing on plastered surfaces for fixing transformer including ramp of suitable size for mounting of transformer complete all as specified and directed. Unit rate quoted by the contractor for the above item shall be deemed to be included for this provision.
Supply, install, erection, commisioning and testing HT 11 KV.outdoor extensible type, cubical , 4-way (LRRL-2LBS+2VCB)), Gas (SF6) Insulated RMU including comprising with 2 Nos x LBS (Load break switches) and 2 Nos x VCB of rating of each 630 Amp 3 phase 50 cycles 12 KV, 20kA/ 3 Sec Ambient temperature - (-5 degree Celsius to +55 degree Celsius), Manual Operated SF6-Breaker having copper busbar 1000Amp rating, cast resin tank with , LV Current transformer compatible with self powered relay& 11KV regin cast PTs (one set of 3Nos) with saperate metering chamber complete including comprising of following Make SIEMENS Model 8DJH ST / Eqivelent Make in Appendix 'B', complete all as specified and directed.
Supply, install, erection, commisioning and testing HT 11 KV.outdoor extensible type , cubical , 3-way (RRL-2LBS+1VCB)), Gas (SF6) Insulated RMU including comprising with 2 Nos x LBS (Load break switches) and 1 No x VCB of rating of each 630 Amp 3 phase 50 cycles 12 KV, 20kA/ 3 Sec Ambient temperature - (-5 degree Celsius to +55 degree Celsius), Manual Operated SF6-Breaker having copper bus bar 1000Amp , cast resin tank with , LV Current transformer compatible with self powered relay& 11KV regin cast PTs (one set of 3Nos) with saperate metering chamber complete including comprising of following all as specified and directed. Make SIEMENS Model 8DJH ST / Eqivelent Make in Appendix 'B'.
Supply , install, erection, testing and commissioning of indoor type HT vacuum circuit breakers panel including having 1 No Incoming VCB and 2 Nos Out going VCBs Panel of each capacity 11 KV, Minimum 630 Amp, 3 Phase, 3 wire, 50 Hz, having 26.3 KA breaking capacity, all specified as per IEC 62271-100 & IEC 62271-200 totally enclosed single bus bar for each phase, floor mounting, metal clad, flush fronted, horizontal draw out type, horizontal. isolation type, Indoor extensible type, with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assembly of 3 vacuum interrupters, with epoxy support insulations and self - aligning finger type isolating contacts, track having integral racking with necessary interlocks ( for insertion and withdrawal of VCB), manual and automatic motor charged independent closing/ tripping spring , trip free operating mechanism with closing and tripping push buttons and mechanical breaker , all standard fitting and accessories including comprising of following :- Each VCB will include the following:- '(a) Bus bar chamber with 3 phase copper bus bar 1000 Amp rating duly insulated - 01 Set ( set of three). '(b) Electrical trip coil 30 V DC /110V DC - 1 No '(c) Electrical shunt coil 30 V DC/110VDC - 01 No '(d) CT Chamber incorporating 3 Nos single phase rasin cast current transformer ratio 100/50/5-5 class 1.0 for metering & class 5P10 for protection and burdon 15 VA , 11 KV, 25 KA for 1 sec - 1 No '(e) 3 Phase, 3 Limb draw out type bus connected Epoxy potential transformer, ratio 11KV/√3/110V/√3 AC accuracy 1.0, burdon 50 VA - 01 No.(only for Incommer) '(f) Digital ammeter 0 to 200 Amp,( 100% of CT ratio)for 3 phase -01 No. '(g) Digital voltmeter rating 0 to 12 KV, for 3 phase - 01 No '(h) DIGITAL Load manager for amps, volts, KW, KVA, KVAR, and PF - 01 No, Make :Conserve EM 6400 or Make: Secure Ellite 443. '(j)Three phase over current and earth fault digital numeric relay (over current (INST 50) & IDMT - 51 - 3 pole & earth fault (INST (50N) & INST (50N) & IDMT 51N - single pole) & negative sequence 46 auxiliary supply 20-110V AC/DC CT out put contacts 2 Nos + NC, rating-5, O/C Is= 20-200% in step of 5% E/F Os=5-80% in step of 5%. with common port ,the features and specification confirming to model No. MI COM P 122 of AREVA or equivalent Make of ABB -REJ601 or Seimen 7SR10.
(k) Auxiliary relay with 6 N/O & 6 N/C - 1No ,Make Alstom/ABB/L&T (l) Master trip circuit - 1No Make Alstom/ABB/L&T. (m) TNC switch and LR switch - 1No (n) Heat control switch - 1 No (o) RYB, ON/Off , spring charred and discharged & VCB trip indications- 1 set (p) Space heater with thermo state & toggle switch - 1 No (q) Operating counter - 1 No (r) Rear and side cable box suitable for 95/ 120 Sq.mm 3 core XLPE cable (s) Spring charging motor with starter 230V AC - 1 No (t) Pluggable anti-pumping relay type CRM 4 with base- 1No (u) Pluggable AC fail relay type CRM 4 with base -1 No (v) Pluggable DC fail relay type CRM 4 with base -1 No (w) CB contact multifunction relay type PSU14(52X) -1No (x) 12W Annunciator + hooter- 1 set (y) Power pack 230V AC-110V DC (z) Control MCB/ Fuse set - 1set (aa) Panel illumination lamp with door limit switch - 1set (ab) Push button for TCH - 1 No (ac) 9 KV , 10 KA , surge arrestor - 1 set of three (ad) Indicating lamp - 1 set (ae) Electrical shunt coil 30 V DC/110VDC – 01 No NOTES :- (i) VCB shall be extensible type. (ii). The contractor shall get the approval of GE for the make of the VCBs they plan to procure. (iii). Prior to manufacturing the general arrangement drawing design details of the VCB panel shall be got approved by contractor from GE. (iii) Civil work (PCC platform) with PCC /Brick work for installation of VCB is deemed to be included in the unit rate quoted by the contractor. The PCC platform details as per the manufacturer's instructions.
Supply & fix 90 watts LED street light fitings new generation energy saving ,environmental friendly ,long life,versatile pressure die cast aluminium IP66 with 10KV surge protection road way,luminaire with high power LED as light source with warranty option of 5 years and suitable drivers etc and connecting with service wire from fittings to the junction box and fixing to complete all as specified and directed , Make :- Crompton greaves Cat part No LSTP-90-CDL or equivalent in Philips/Wipro.
Supply, install, test and commissioning factory made THERMOPLASTIC CABLE JUNCTION BOXES IP 66/67 “weather proof”, with five terminal of 100A each (all terminal have 2 clamping units per pole) for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal including MCB SP 6 A - 1 No complete all as specified and directed. Make Hansel Cat part No:KF 2525 G or equivalent make in /Legrand/FIBOX(SOLID PC 2528 13G).
S&F GI bracket of 1.2 mtr long for street light made out of 40mm dia light grade GI pipe bend to shape of 120/150 degree end welded as required including 02 Nos MS clamp of flat iron 50 x 6mm including nuts bolts & washers with complete necessary fixing arrangements on pole complete all as specified and directed.
S & Fixing of LED flood light fitting suitable for 16Mtr highmast light pressure die cast housing with IP66 protection , surge protection 10KV, Efficient high output emitter LED for better distribution and applicable for area lighting.Mall complete all as specified and directed of following capacites :-
LED flood light 300 Watts Make crompton Cat No LSFO-300-CDL/60-M or equivalent Havells/Wipro/Philips
LED flood light 250 Watts Make crompton Cat No LSFO-250-CDL/60-M or equivelent in Havells/Wipro/Philips
Supply, install, commissioning and testing factory made (including CPRI type test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz, AC supply system all as specified and directed having busbar chamber with insulated aluminium bus bars 400 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm thick CRCA MS sheet outer & inner and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work.The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm, Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys complete including comprising of following :- INCOMING (a) MCCB 4 Pole 160 Amps 36 KA - 01 No. (b) Bus bar Al TPN 400 Amps - 01 Set. OUTGOING - (a) MCCB 4 Pole 100 Amps 16 KA - 01 No. (b) MCCB 4 Pole 63 Amp 16 KA - 4 Nos ''Note: Space of out going MCCB 1 No to be provided and panel shall be mounted on 2' height PCC platform as per manufacturer's instructions and as directed. The unit rate quoted by the Contractor for the item shall be deemed to be included these provisions.
Supply, install, commissioning and testing factory made and tested (includng CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz, AC supply system all as specified and directed having busbar chamber with insulated aluminium bus bars 300 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm thick CRCA MS sheet outer & inner 3.15 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for base frame work.The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm, Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys complete including comprising of following :- INCOMING (a) MCCB 4 Pole- 63 Amps - 01 No. (b) Bus bar Al TPN 300 Amps - 01 Set. OUTGOING (a) MCB TPN 40 Amps 415 Volt-2 Nos ''Note: Space of out going MCCB 1 No to be provided and panel shall be mounted on 2' height PCC platform as per manufacturer's instructions and as directed. The unit rate quoted by the Contractor for the item shall be deemed to be included these provisions.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe up 100mm dia complete all as specified and directed. Note :- GI pipe shall be measured and paid seperately under relevant item of BOQ/Schedule.
M&L for Shifting of existing transformer out door type, 63 KVA, 11 KV/433 volts copper/ Aluminium wound from 2/4 pole structure mounted including Air break switch DO unit LT panel and transporting the same to another location and installation on new 4 pole structure with neccessary fixing arrangment including connecting up electrically, commissioning and testing complete all as specified and directed. Note :- Cost of new 4 pole structure shall be measured and paid separately under relevant item of BOQ/Schedule.
M&L Disconnecting,dismentling and taking out existing VCB Panel having 1 No Incomming and 2 Nos out going VCBs including 11 KV RSEB metering Panel, safely from Old VCB room and shifted at New constructed VCB room at MRS bharatpur including providing HT electric connection after testing, commissioning and calibration of VCBs complete all as specified and directed.
Disconnecting and taking down old vintage transformers of any make & type and deposited to AGE E/M store yard safely complete all as specified and directed.
Disconnecting and taking down old U/S HT VL switch of any size, make & capacity, and deposited to E/M store yard safely complete all as specified and directed .
Taking down old sodium / LED fitting of any make & type and deposited to AGE E/M store yard safely complete all as specified and directed.
S & F cable route indicator HT/LT with colour code ( BROWN) HT/LT 10cm dia made of cast iron 8mm thick fixed on MS angle iron of size 25x 25x 5mm, 60cm long complete including fixing necessary excavation in soft/loose soil embedded in PCC 1 : 2 : 4 type B1 block of size 300 x 200 x 600mm( 30 cm of PCC elevated above ground level) and removal of surplus soil and marked as HT cable / joints on circular cast iron plate with colour code complete all as specified and as directed
Supply, Install, testing & commissioning of automatic, unbalanced type three phase Oil Cooled Line Servo Voltage Stabilizer of rating 500 KVA , efficiency 98-99% , As per IS 9815 Standards, 24 Hrs duty cycle, incl. High & Low Voltage Cut Off ( HLVC ) ,Control through Micro Processor Controller/1C based solid state plug in type glass epoxy control Card, all the three phases controlled individually for better voltage and load management,suitable for all power factor loads, 98-99% efficiency being achieved by optimum design and by use of high quality CRGO lamination and 99.9% pure copper, Single Phasing Protection ( SPP ) & first filling of transformer oil . The three phase Oil Cooled Line Servo Voltage Stabilizer must have include the following features :- (a) I/P Voltage Range : 270V - 470 V. (b) Out put range : 400V+ 1%, & Output Adjustment- 380 – 415 V AC (c) Type : Suitable for Unbalance/Balanced input and balanced and Unbalanced load Type (d) Response Time : less than 10 ms. (e) Output Voltage Regulation : 1% of the set value. (f) No Load Losses : Less than 1%. (g) Effect of PF on O/P Voltage : NIL. (h) Waveform distortion on O/P Voltage : NIL. (i) Winding Wires : Pure electrolyte grade copper wires. (j) Type of Cooling : Oil Cooled. (k) Mounting : On Wheels. (l) Additional Facilities : Alarm Annunciator & Manual Operation. (m) Metring : Digital display, monitoring input and output voltage (n) Protection :-Under / Over Voltage Cut off Protection,Overload / Short Circuit Protection, Manual Bypass – Changeover,Surge Protection using SPD, Class C,Single Phase Prevention (o) Switch gear : MCCB at input and Contactor at output, Manual Bypass changeover switch as per current rating and voltage (p) Earthing terminal to be provided (q) High voltage can be withstand upto 2.5KV for 5 second
Supply, installed, testing and comminsioning outdoor type, made out of MS Sheet 3.15mm thick duly powder coated ,CPRI certified manufacture,Self standing, double door, front and back openable, APFC panel compartmental type with APFC relay 8 stage with heavy duty MPP capacitor bank 120KVAR (5 KVAr-3Nos, 10 KVAr-03 No, 25KVAr-01 No, 50KVAr-01 Nos, with 7% detuned harmonics filter reactor. ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating currect of capacitor suitable for each control and MCCB TPN 250 Amp 36 KA as incomer including control CT & control wiring complete with HR FRLS copper wire including having following assessories complete all as specified and directed :- (i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry (ii) Capacitor installed in removable assemblies for ease of operation and maintenance (iii) Incoming of APFC panel of MCCB TPN 250 Amps, 36 KA breaking capacity with high electrolytic grade Aluminium bus bar iof suitable rating. (iv) 120KVAR (5 KVAr-3Nos, 10 KVAr-03 No, 25KVAr-01 Nos, 50KVAr-01 Nos ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating current of each capacitor suitable for each control . ( each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor. (v) High performance microprocessor based 3 phase APFC relay 8 stage with Auto/Manual Option. (vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No) (vii) Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors (viii) Induced air system provided with axial flow fan/ centrifugal fan. (ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front
Supply ,installed, testing and comminsioning outdoor type ,made out of MS Sheet 3.15mm thick duly powder coated ,CPRI certified manufacture,Self standing, double door, front and back openable, APFC panel compartmental type with APFC relay 4 stage with heavy duty MPP capacitor bank 40KVAR (5 KVAr-1Nos, 10 KVAr-01 No, 25KVAr-01 No, with 7% detuned harmonics filter reactor ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating currect of capacitor suitable for each control and MCCB TP 100 Amp 16 KA as incomer including control CT & control wiring complete with HR FRLS copper wire including having following assessories complete all as specified and directed :- (i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry (ii) Capacitor installed in removable assemblies for ease of operation and maintenance (iii) Incoming of APFC panel of MCCB TP 100 Amps, 16 KA breaking capacity with high electrolytic grade Aluminium bus bar iof suitable rating. (iv) 40 KVAR (5 KVAr-1Nos, 10 KVAr-01 No, 25KVAr-01 Nos) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating current of each capacitor suitable for each control . ( each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor. (v) High performance microprocessor based 3 phase APFC relay 4 stage with Auto/Manual Option. (vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No) (vii) Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors (viii) Induced air system provided with axial flow fan/ centrifugal fan. (ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front
Supply ,erect, testing and commissioning of 16M High Mast shaft in two sections with 3mm thickness suitable for 50m/Sec wind speed, with raising lowering system comprising, head frame, luminaries carriage suitable to install 9 Nos luminaries in symmetrical arrangement,SS wire rope of 06mm dia 97/19 gauge and double drum winch, trailing cable,connector, integral power tool motor, manual handle, junction box, lightening finial.Wiring material,power cables between panel and Mast, MCB in base compartment, Cg mounting clamps and bolts , including foundation bolts manufactured from special steel alongwith nuts and including Construction of shallow foundation with M25 grade concrete for the high Mast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour., washers, anchor plate and template, complete with including following accesories:- (a) Twin dome aviation obstruction lights with two Nos 100 W GLS lamps (b) Outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 30 A TP contactor for the automatic switching of luminaries,power tool control with 2 No 9A contactors and raise lower push button,Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals. Notes (i) Cost of Earth work, construction of shallow foundation as per manufacturer's instructions meeting with IS code requirement for Bharatpur area for such structure etc shall be deemed to be included in the unit rate of the above item quoted by the contractor. (ii) LED flood light shall be measured and paid separately under relevant item of BOQ/Schduled.
S & F PVC insulated stranted copper conductor cable of size 1.5 sqmm x 3 core from Juction box to street light complete all as specified and directed.
FRIZO INDIA PVT LTD
Bal Singh and Sons
Leo Air and Power Solution pvt Ltd.
Sant Construction Co.
M M Brothers
Chauhan Associates
Sood Enterprises
Sudhir Sharma Associates
B D Raizada Projects Pvt Ltd
Konstelec Engineers Pvt. Ltd.
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .