| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
14 Mar 2026, 6:00 pmClosed
CWE Khadki Pune
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
REPAIR MAINT AND REPLACEMENT OF LT AND HT ELECTRIC DISTRIBUTION SYSTEM ALL TYPE OF CABLES LT SWITCHGEARS STREET LIGHTS AND OTHER ALLIED WORKS AT CQA A AND SQAE OF AGE EM II UNDER GE CENTRAL KHADKI
2026_MES_753770_1
CWE/KKE/TOKEN-66 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE Khadki Pune
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE CENTRAL KHADKI
₹92,000
Yes
18 May 2026
21 Feb 2026
17 Mar 2026
21 Feb 2026
14 Mar 2026
7 Mar 2026
21 Feb 2026 - 28 Feb 2026
Taking down old unserviceable street light/flood light/post top/bollard light of any capacity complete all as specified and as directed by Engineer - in - Charge.
Taking down old unserviceable MCB/MCCB/change over of any capacity complete all as specified and as directed by Engineer - in - Charge.
Taking down old unserviceable driver of any capacity complete all as specified and as directed by Engineer - in - Charge.
Taking down old unserviceable service wire of any size complete all as specified and as directed by Engineer - in - Charge.
S&F for LED Street light 45W including making electrical connection to the fitting with Suitable size of service wire complete all as specified and as directed by Engineer - in - Charge .Make:- Crompton or techno commercial equivalent in Phillips/Wipro
S&F for LED Street light 60W including making electrical connection to the fitting with Suitable size of service wire complete all as specified and as directed by Engineer - in - Charge. Make:- Crompton or techno commercial equivalent in Phillips/Wipro
S&F for LED Street light 90W including making electrical connection to the fitting with Suitable size of service wire complete all as specified and as directed by Engineer - in - Charge. Make:- Crompton or techno commercial equivalent in Phillips/Wipro
S&F for LED Flood light 100W including making electrical connection to the fitting with Suitable size of service wire including dismantling of old one complete all as specified & directed by Eng-in-Charge. Make:- Crompton or techno commercial equivalent in Phillips/Wipro
S&F for LED Flood light 120W including making electrical connection to the fitting with Suitable size of service wire including dismantling of old one complete all as specified & directed by Eng-in-Charge.Make:- Crompton or techno commercial equivalent in Phillips/Wipro
S&F for LED Post top luminaries 40w decorative post top for 360 degree indirect light fixing on existing pole with all necessary fixing arrangement and all accessories prewired including connecting up with twin core copper conductor cable with suitable size complete all as specified and as directed by Engineer - in - Charge. make : Crompton or equivalent
S&F for LED bollard light fittings, LED 10Watt, all including fixing material and earth work complete and connected to neares electric pole complete all as specified and as directed by Engineer - in - Charge. Make: Crompton (Cat No: LBLSN-10-CDL ) or equivalent
S&F for street light mounting bracket, made out of Light grade GI Tubing 32 mm bore , bend into shape inner angle not less tan 120° and over all length not less tan 1.0 Mtr including suitable size clamps made from not less than 25x3 mm ms streep , Nut, bolts 12 mm dia with washers complete fixing arrangement complete all as specified and as directed by Engineer - in - Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 Metre deep and not exceeding 1.5 metre width and getting out including forming bottom surface & sides to required slope/size complete all as specified and as directed by Engineer - in - Charge.
M&L for sand/fine dust cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : punning thickness of 18 cm will be measured for payment)
S&F for un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and as directed by Engineer - in - Charge.
S&F for un-reinforced precast concret cable cover class HV type 1, flat size 300mm x 180mm x 40 mm complete all as specified and as directed by Engineer - in - Charge.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil complete all as specified and as directed by Engineer - in - Charge.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engr-in-charge.
Supply and Lay LT underground cable XLPE insulated armoured heavy duty 1100 Volts grade with aluminium conductor multistranded including centre glands/lugs/jointing materials etc..laid in trench or fixed it to wall including dismantling of old one, connecting testing and commissioning complete for the following sizes:
All as per items No.19 above for 10 Sqmm 2 core
All as per items No.19 above for 16 Sqmm 4 core
All as per items No.19 above for 25 Sqmm 3.5 core
All as per items No.19 above for35 Sqmm 3.5 core
All as per items No.19 above for 50 Sqmm 3.5 core
All as per items No.19 above for 70 Sqmm 3.5 core
All as per items No.19 above for 95 Sqmm 3.5 core
All as per items No.19 above for 120 Sqmm 3.5 core
M & L XLPE insulated , screened, PVC bedded , galvanised steel strip or wire armoured , electric power cable (Heavy duty) with alluminium conductor, cross sectional area 95 sqmm 3 core 11000 Volts HT grade complete all as specified and as directed by Engineer - in - Charge.
S&F for PVC sheathed 1100V grade flat three core stranded aluminium conductor of size 2.5 sqmm including conduit pipe connecting from SMC box to street light fitting Complete all as specifed and directed by Eng-in-Charge
M&L for earthing complete with copper bonded earthing, outer pipe 88mm dia medium grade and inner pipe 55 mm dia including testing, 3 mtr long and having 50x6 mm terminal on inner pipe to connect earthing strip with 14 mm holes for nut bolts, buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.3 mtr deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with copper earthing lead of 32x6 mm strip with minimum two Nos of copper nut bolits and connected to test point from earthing pit. The electrode pipes should be filled with 2x 25 kg bags of carbon based earthing compound. The resistance of the compound should be less than 0.1 Oms . The compound should be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities with ph value between7-9. Connected to the earthing test point, Fiber reinforced plastic pit not less than 300x300 mm with pit cover, including necessary returning filling & removal of extra soil , to achieved earth resistance value less than 5 Oms including testing complete all as specified and as directed by Engineer - in - Charge. NOTE: IF the desired result not obtained after testing the contractor should do re-eathing without any extra cost.
S&F for 40 mm bore GI tubing light grade in trenches or on pole for cable protection complete all as specified and as directed by Engineer - in - Charge.
M & L Aluminum lugs eye lid or barrel type complete with cripping/soldering etc including removing the wornout lugs suitable for aluminium cables/copper cables of sizes from 16 Sqmm to 95 Sqmm complete all as specified and as directed by Engineer - in - Charge.
S&F for MCCB 415V, 3 phase 50 HZ FP 63 to 100 Amps breaking capacity 16KA complete all as specified and as directed by Engineer - in - Charge. Make -Legrand or equivalent in Schneider/Havells/ CG/ L&T.
S&F for MCCB 415V, 3 phase 50 HZ FP 125 Amps breaking capacity 16 KA complete all as specified and as directed by Engineer - in - Charge. Make -Legrand or equivalent in Schneider/Havells/ CG/ L&T.
S&F for MCCB 415V, 3 phase 50 HZ FP 200 Amps breaking capacity 36 KA complete all as specified and as directed by Engineer - in - Charge. Make -Legrand or equivalent in Schneider/Havells/ CG/ L&T.
S&F for MCCB 415V, 3 phase 50 HZ FP 250 Amps breaking capacity 36 KA complete all as specified and as directed by Engineer - in - Charge.Make -Legrand or equivalent in Schneider/Havells/ CG/ L&T.
S&F for MCCB 415V, 3 phase 50 HZ FP 400 Amps breaking capacity 36 KA complete all as specified and as directed by Engineer - in - Charge. Make -Legrand or equivalent in Schneider/Havells/ CG/ L&T.
S&F for On load change over switch 250A, 4 pole complete all as specified and as directed by Engineer - in - Charge.Make -Legrand or equivalent in Schneider/Havells/ CG/ L&T.
S&F for MCB, single pole, 6-32 Amp, 240 Volts, 'C' Curve 10KA including dismantling old one complete all as specified and as directed by Engineer - in - Charge. Make: Legrand ( DX3)/C&S/Schneider/L&T
S&F for MCB, Triple pole and neutral , 40 Amp, 415 Volts, 'C' series 10 KA including dismantling old one complete all as specified and as directed by Engineer - in - Charge. Make: Legrand ( DX3)/C&S/Schneider/L&T
S&F for Triple pole and neutral , 63 Amp, 415 Volts, 'C' series 10 KA including dismantling old one complete all as specified and as directed by Engineer - in - Charge. Make: Legrand ( DX3)/C&S/Schneider/L&T
S&F for LED power output driver of LED street light with power output up to 45W including dismantling defective driver from existing light fitting complete all as specified and as directed by Engineer - in - Charge.
S&F for LED power output driver of LED street light with power output from 45W to 60W including dismantling defective driver from existing light fitting complete all as specified and as directed by Engineer - in - Charge.
Disconnecting and taking out existing SMC of any size and in any position on pole and Supply & fix in repair sheet moulding compound junction (SMC) suitable for terminating 2 Nos 4 x 6/10/16 Sqmm UG cable including S&F of one in Nos MCB SP 6-32A including cable glandes- 2 Nos, and two way connector 1 No, including dismantling old one complete all as specified and as directed by Engineer - in - Charge. Make ; Sintex/National
Supply, fixing and commissioning Digital type Time switch having sleek MCB shaped design with front display and DIN rail mounting, power reserve for atleast 1500 hrs, operating voltage - 240 V AC, 50 Hz, working temp. upto 55 degree celcius complete with all accessories complete all as specified and as directed by Engineer - in - Charge.
M&L for cable jointing kit for 1.1 KV grade cable for straight through ( Heat Shrinkable) joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 to 35 Sqmm including dismantling the old burnt cable joint termination complete all as specified and as directed by Engineer - in - Charge.
M&L for for straight through ( Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50sqmm to 95 Sqmm including dismantling the old burnt cable joint termination complete all as specified and as directed by Engineer - in - Charge.
M&L for preparation of old painted surface of LT Steel tubular pole of any length by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing support on poles and writing of identification Nos with proper stencil cut etc complete all as specified and as directed by Engineer - in - Charge.
M&L for preparation of old painted surface of HT Steel tubular pole of any length by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing support on poles and writing of identification Nos with proper stencil cut etc complete all as specified and as directed by Engineer - in - Charge.
M&L for preparation of old painted surface of F/P box/LT Panel by removing all dirt, dust, etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour over a coat of primer including writing of identification with proper stencil cut etc complete all as specified and as directed by Engineer - in - Charge.
Supply and errect in true vertical position LT electric pole, Octogonal Pole, hot deep galvanised, with base plate of 220x220x12 mm thick, 07 Mtrs Long, top dia 70mm, bottom dia- 135mm, thickness of sheet- 3 mm, including Single arm GI bracket, inbuilt cable junction box with door, connection plate, MCB 6A, duly connecting existing LT UG cable, cable lugs, work included necessary earth work and RCC foundation as per manifacturers recommendation complete all as specified and as directed . Make: Bajaj / Crompton or as approved by GE Note: Earth work, PCC foundation as per manufacturer recommendation included in the unit rate complete all as specified and as directed by Engineer - in - Charge.
Supply and errect in true vertical position steel tubular swaged poles in replacement complete with MS base plate of 6mm of size 300mm X300mm finial taper plug,pole cap,bolts,nuts and washers screws,pole made out of ERW MS tubing as per IS-1161 and pole shall be as per IS-2713 Part II type 410 SP-31 (9.00 Mtrs Long) complete including one coat of red oxide zinc chrome primer and two coats of Aluminium paint for exposed surfaces and two coats of black bitumenous paint for portion embedded in concrete complete all as specified and as directed by Engineer - in - Charge. Note: Excavation and earth work ,PCC in foundation /plinth block/coping shall be measured and paid separately
M&L for dismantling electric pole any type any size and removing from site complete all as specified and as directed by Engineer - in - Charge.
Excavation in trenches n.exc. 1.5 mtr in wide and exc. 1.5 mtr but n. exc 3.0 m in depth and getting out in hard / dense soil complete all as specified and as directed by Engineer - in - Charge.
M&L for Cement concrete in foundation filling and mass concrete 1 : 4 : 8 type D2 complete all as directed by Engineer-in-charge.
M & L for PCC 1:3:6 type C-1 with 20mm agregate in copping including necessery form work all as directed by Engr-in-Charge
M&L for filling and spreading stone aggregate using 40 mm grade trap stone aggregate around 4 pole , 2 pole structure and transformer etc.
Surface Excavation n. exc. 30 cm deep and avaraging 15cm deep and getting out soft/loose type of soil complete all as specified and as directed by Engineer - in - Charge.
M&L for PCC 1:2:4 type B2 with 40 mm graded stone aggregate cement concrete in filling and mass concrete all as directed by Engr In charge
M&L for coloured machine pressed precast concrete interlocking paver block glossy finish (Two colour combination ) any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 grade with grey cement and pigment laid over sand cuhsion complete all as specified and as directed by Engineer - in - Charge.
M&L for cutting through existing bituminous road /PCC/floor/ along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finishes complete all as specified and as directed by Engineer - in - Charge. Note: GI Pipe will be measured and paid seperately in respective item.
M&L for disconnecting LT XLPE cable of any size from LT Panel or any location as directed for finding fault and M&L for defect rectification underground cable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. complete all as specified and as directed by Engineer - in - Charge. Note: (i) The fault locating equipments will be brought to site within the 12 hours of instruction from Engr-in-Charge. (ii) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and has to be rectified within 12 hours after notification, failing which Rs 500/- per day per complaint will be recovered from the dues to the contractor. (iii) Rates included necessary earth work for opening cable for ready to jointing.
M&L for preparation of old painted surface of installation by removing all dirt, dust, grease, oil etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour by spray including writing of identification SM & MES Nos, capacity etc complete all as specified and as directed by Engineer - in - Charge for following transformer/Generator including outer body of silent DG Set :-
All as per items No.63 above for Transformer 500KVA
All as per items No.63 above for Transformer 150 KVA
M&L for cutting and removing grass, vegetation bushes etc from surrounding E/M installation and removing all rubbish to a distance not exceeding 50 m as directed Complete all as specified & directed by Eng-in-Charge.
Dismantling old cross arms MS clamp and angle from LT/HT pole Complete all as specified & directed by Eng-in-Charge.
M&L for cross arm bacing support to clamps and back plate fabricated from structural steel section like angles channels flat etc including nuts bolts and washers welding bending cold or hot drilling holes for bolts if any shape and size and incl applying two coats of aluminium paint over one coat of red oxide primer Complete all as specified & directed by Eng-in-Charge.
Supply and lay Elecsafe-AH-Insulated HT Electrical matting as per IS 15652:2006 Class B Working voltage up to 11 KV, 2.5mm thickness,1 mtr* 5mtr roll, Blue colour with one side fine chequered & other side anti skid small button.PCN No. ALA 6000 072 .
S&F for type 4 Electrical insulated hand gloves test potential 25000V , Working Voltage 17000V As per IS 4770 Size 355 mm PCN No. ASA LA 4000 009 .
S&F for 11 KV Polymeric Gang Operated Air Break Switch complete with operating mechanism for current rating upto 400 amps Complete all as specified & directed by Eng-in-Charge.
S&F for 11 KV Lightning arresters polymeric insulator type complete with all fittings, transmission class Complete all as specified & directed by Eng-in-Charge.
S&F for 11 KV Polymeric Drop Out Fuse with brass contact bolts and nuts having maximum current,11 KV up to 25 amp.Complete all as specified & directed by Eng-in-Charge.
S&F for in repair end cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for cable 3 core 120 to 185 sqmm XLPE insulated armored with aluminium conductor 11000 voltsComplete all as specified & directed by Eng-in-Charge.
M&L for repairs to unsv transformer at site, removing leakage of transformers, replacement of unsv spares like temp gauge, HT/LT bushing with connecting rod, top cover gasket, tap changer assy, reassembling, testing etc complete capacity of transformer from 100KVA to 500 KVA Complete all as specified & directed by Eng-in-Charge. NOTE :- (a) All the necessary tools, tackles, lifters and ladder shall be arranged by the contractor for the subject work. (b) Rate including all necessary minor spares and excluding major spares required to be replace during job will be measured and paid under relevant item.
Supply only following items to be incorporate in the item No 76.00 above for repair of transformer at site:-
Neoprine top cover gaskets suitable 100KVA to 400 KVA transformer Complete all as specified & directed by Eng-in-Charge.
HT bushing set of 3 with brass spindle nut bolt washers etc for100KVA to 500 KVA transformer as per existing size and shape complete all as specified & directed by Eng-in-Charge.
LT bushing set of 4 with brass spindle nut bolt washers etc capacity from 100KVA to 500 KVA transformer as per existing size and shape complete all as specified & directed by Eng-in-Charge
Silica jel breather assy for indoor/outdoor transformer of capacity from 100KVA to 500KVA all as specified & directed by Eng-in-Charge
Dial type temperature gauge with suitable spindle dia, dual calibration in degree celcius and degree Fahrenheit, range 0 to 100˚c and equivalent degree Fahrenheit complete capacity from 100KVA to 500KVA all as specified & directed by Eng-in-Charge
Buchholz Relay as per existing suitable for step down transformer capacity from 100KVA to 500KVA all as specified & directed by Eng-in-Charge
Tap changer assy complete as per exisiting, suitable for tansformer of capacity 100 to 500KVA all as specified & directed by Eng-in-Charge
S&F in repairs Brass metal studs nut & washers suitable for transformer 100 KVA to 500 KVA all as specified & directed by Eng-in-Charge
M&L for filtration of insulating oil of transformer in situation to bring the brake down value of oil not less than 40 KV at 2.5 mm gap all as specified and directed by Engineer-in-Charge.
Supply and fill transformer oil on topping up of transformer Complete all as specified & directed by Eng-in-Charge.
Supply and fill in repairs existing breather silca jel of superior quality for transformer breather Complete all as specified & directed by Eng-in-Charge.
M&L for disconnecting HT XLPE cable of any size from structure/pole/transformer for finding fault, defect rectification HT cable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal or any type of strata required for exposing the cable fault. removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of any size. The fault locating equipments will be brought to site within the 6 hours of instruction from Engr-in-Charge as specified and as directed. Note: 1. Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and will be rectified within 6 hours after notification, failing which Rs 500/- per day per complaint will be recovered. 2. Rates included necessary earth work in any type of strata or Road or Tank road for opening the cable and prepare the cable ready to jointing work and making good to match with existing finishes
Labour only for attending street light complaints and rectifying the faults viz non ops & flickering of street light, Cable or service wire damage, earth leakage & electric shock in street light poles & panel, hanging or bending of street light etc up to entire satisfaction of Eng-in-Charge including all necessary petty items like lugs, nut, bolts, screws and any type of tool required. Note:-Group of complaints for one feeder will be consider as one job. Complaint slip will printed and supplied by contractor in prescribed format as specified by Engr-in-Charge.
Repairs/overhauling of LT air circuit breakers of any make of any capacity and replacement of minor items like springs, washers, bolt/nuts & washers and other insulating materials etc and also including calibration and testing of control and protection devices of equipments in the following steps all as directed by Engr-in-Charge : (i) Disconnecting and taking out the breaker after taking shut down of the respective panel/tapping point and check the defects. (ii) Overhauling the ACB by opening all parts and lubricating the moving parts as per requirement. (iii) Re-assembling the air circuit breaker complete, install at it's original position, testing and commissioning the breakers for both mode as tripping mechanism and closing mechanism for proper functioning of the breaker all as specified and as directed.
M&L for Isolate/de-energize the supply of LT Panel Board of capacity upto 400 Amps and voltage 415 Volts/230 Volts, opening the doors/covers of the cubicle enclosure for carrying out the servicing / maintenance / repairs of the Panel Board, switch gear, metering fixures etc and re-fixing the same at it's place after following repairs/check for smooth functioning complete all as specified and directed by Engr-in-Charge :- a) Cleaning the inside switch gear chambers for removing dust and carbon including cleaning with the help of blower and apply insulating varnish. b) Check the condition of the support insulators including cleaning applying Dr beck red for better IR values and replacement of support insulators if required and as directed by Engr-in-Charge. c) Tightening up of all bus bar connections, cable connections, replace nut/bolts & washers wherever required.
M&L for disconnecting and taking down the existing bus bars of 4 wire system of cap 200 Amps to 1600 Amps from LT panel board any type and cleaning with CTC applying with becktol solution, removing old insulation and providing new heat shrink insulating sleeves, connecting and fixing at it's place with new/existing nuts, bolts and washers of suitable size complete all as specified and directed by Engr-in-Chage.
M&L disconnecting and taking out old existing burnt/worn out control wiring connections as per requirement incl cable lugs, glands of LT panel board of 4 wire system of any capacity and replace with new cable PVC insulated, stranded copper conductor size as per existing incl lugs, glands, nuts, bolts & washers complete all as specified and directed by Engr-in-Chage.
M&L for disconnecting and taking out old existing worn out cable lugs, nuts, bolts, washers etc from LT panel board of 4 wire system of any capacity (incomming and outgoing) and supply and connect with new aluminium lugs and nuts, bolts, washers etc complete all as specified and directed by Engr-in-Chage.
Taking out old existing worn out neoprene gasket from shutters of LT panel board single/double doors panels any type any capacity or openable on both sides and supply and fix new neoprene gasket complete all as specified and directed by Engr-in-Chage.
Note for Item No 90 to 95 : (i) Contractor should visit the site before quoting the rate. (ii) Rates including for any modifications/frame work and renewal/welding work during maint. (iii) Minor spares like cleaning/lubricating and cleaning materials, nut bolts, washers, lugs/glands etc included in the unit rate and major spares will be measured and paid under relevant items of schedule (iv) Contractor should take proper shutdown from MES rep and should take all safety precautions of equipments and manpower. Any damage of dept assets will be the responsibilites of contractor. (v ) All T&P, safety equipments required for completion the job included in the unit rate.
Supply only following spares for execution under overhauling item No 90 above as per existing LT Panel/ACBs make all as per specified and as directed by Engr-in-Charge at site:-
Lockable trip Push button as per existing
Lockable trip push button kit as per existing
Racking interlock as per existing
Racking Padlock assembly as per existing
Door interlock as per existing
Spring charge indication switch as per existing
Vertical terminal adaptor for draw out ACB upto 1000 Amps
Shunt Release 240V AC
Shunt release 415V AC
Under voltage release 240V AC
Under voltage release 415V AC
Earth fault release as per existing
Main Isolating (Jaw) Contacts
Main Fixed Contacts (Upper Terminals)
Lower Terminals with Fitting Plates
Main Moving Contact Assembly
CTs for L&T ACBs type upto 400 Amps C/H Fix & Drawout
M&L for fabrication and installation of glow Sign board (640 cm x 91cm x 25cm) made of Flex/Acrylic board, with computer imaging matter is directed by engr-in charge at one side of the board, GI plain sheet, cubicle housing having with intenal tube light fitting arrangement to open the flex/Acrylic board and suitable for mounting on wall/ gate complete all as directed by engr-in-charge. Note :- The cost of Fabrication and welding work is included in the quoated rate .
M&L for fabrication and installation of Sign board (240 cm x 91cm x 25 cm) made of Flex/Acrylic board, with computer imaging matter is directed by engr-in charge at one side of the board, GI plain sheet, cubicle housing having arrangement to open the flex/Acrylic board and suitable for mounting on wall complete all as directed by engr-in-charge. Note :- The cost of Fabrication and welding work is included in the quoated rate .
Note : a) Contractor has to arrange his own vehicles along with mounted hydraulic ladder/articulated & telescopic boom lift arrangement for attending the complaint of Street light throughout CQA, PTL, SQAE,NAI Area. (b) Contractor shall depute minimum 2 staff to attend and rectify the complaint of street light. if not, Contractor shall have to bear a penalty of Rs 50.00 per complaint or maximum of Rs 500 per day on this account (c) Complaints has to attend and rectify the complaint/defect irrespective of no of trips/Complaints as alloted by Eng-in-Charge
stage.html
html • 0.04 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.25 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
tenderdocuments.pdf
Tender Documents • 1.26 MB
BOQ_844267.xls
BOQ • 2.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .