| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.7 LAccepted-AOC 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 1 | Accepted-AOC being lowest | |
| 2 | 2₹10.1 L+₹4.2 L (71.0%)Rejected-Finance | 2 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
29 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE FATEHGARH
GE MES FATEHGARH
REPAIR AND MAINT OF SUMMER APPLIANCE and VOLTAGE STABILIZER AT FATEHGARH CANTT UNDER GE FATEHGARH
2020_MES_344376_5
GE/FAT/ET-07 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
GE MES FATEHGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE FATEHGARH
₹12,000
Yes
23 Mar 2021
2 Dec 2020
31 Dec 2020
2 Dec 2020
29 Dec 2020
2 Dec 2020
60 days
Amount
Taking out/dismantling defected window/ split type air conditioner of any make and capacity from various locations (irrespective of height) and transporting to contractor workshop to carry out necessary repair as required by replacing the unserviceable parts with new one including cleaning the airconditioner with water and air fresher and refixing the same on various locations as directed after repairing including testings onload at site complete all as specified and directed. Note: All spares, fan motors, relay, capacitor, overload etc shall be measured and paid separately under S & F items here in after.
Taking out window/split type Air conditioner of any make and capacity from positon and carry out complete maintenance by cleaning the cooling coil, condenser coil with chemical base solution and water servicing, oiling, greasing complete including checking of electrical connections and re-fixing the same on its original position and testing on load up to satisfaction of Engineer-in-Charge complete all as specified and directed. Note: In case any spare/part caused damage during the carrying maintenance of air conditioner the same shall be got replaced by the contractor at his own cost. Nothing shall be admissible on this account of replacement of spare/part.
Dismantling / taking out unserviceable burnt sealed compressor unit from air conditioner and fixing only hermitically sealed rotary type compressor unit of any capacity including necessary welding the same with existing refrigerant pipe, supply and charging refrigerant gas including testing complete all as specified and directed. Note: (i) Sealed unit compressor shall be measured and paid separately under supply only. (ii) Replaced compressor unit shall be accompanied with a certificate from a manufacturer to the effect that the said compressor has been supplied by their authorized centre further a warranty of not less than 12 months of all such replacement. (iii) In case replaced compressor unit burnt. It shall be replaced including supply and recharging the refrigerant gas by the contractor without any extra cost. (iv) If any item required to made equipment functional like capillary, copper pipe etc is deemed to be included in quoted rate, (v) Necessary repair work shall be carried out at site/contractor's workshop/E/M yard the cost of handling/transporting the unit shall deemed be included in quoted rate.
Supply only hermitically sealed/Rotary type compressor unit of capacity 1.5 TR complete all as specified and directed. Make: Kirloskar Copeland Emerson/Techmesh/Carrier/Hitachi/Blue Star
Supply only hermitically sealed/Rotary type compressor unit of capacity 2.0 TR complete all as specified and directed. Make: Kirloskar Copeland Emerson/Techmesh/Carrier/Hitachi/Blue Star
S&F FHP (Frictional Horse Power) motor of capacity 1/5 to 1/18 single phase 920 RMP with starting and running capacitor suitable for window type AC complete all as specified and directed. Make: AUE or equivalent approved by the GE.
S&F starting capacitor 80-100 MFD including taking out unserviceable part and complete all as specified and directed. Make: Keltronor or as recommended by the manufacturer or equivalent approved by the GE.
S&F starting capacitor 100-120 MFD including taking out unserviceable part and complete all as specified and directed. Make: Keltronor or as recommended by the manufacturer or equivalent approved by the GE.
S&F running capacitor 36-50 MFD including taking out unserviceable part complete all as specified and directed. Make: EPCOS or as recommended by the manufacturer.
S&F starting relay suitable for 1.0/1.5/2.0 TR compressor including taking out old relay complete all as specified and directed. Make: HI-tech/Classic or as per recommended by manufacture or equivalent as approved by GE.
S&F thermostat suitable for window/Split type A/C including taking out unserviceable part complete all as specified and directed.
S&F condenser/cooling fan blade suitable for window type AC of any make & capacity including taking out unserviceable part complete all as specified and directed.
S&F blower fan motor suitable for split AC of any capacity & make including taking out unserviceable part complete all as specified and directed.
Supply only Remote PCB for a split type AC 1.5 TR capacity & make recommended by the manufacturer complete all as specified and directed.
Supply only Remote PCB for a split type AC 2.0 TR capacity & make recommended by the manufacturer complete all as specified and directed.
S&F in repair ML-1 contactor 240volt 25 Amps for split type AC 1.5/2.0 TR complete all as specified and directed.
S&F Blower both end coupling complete for split AC 1.5/2.0 TR of any amek including taking out unserviceable part complete all as specified and directed.
S&F cooling coil suitable for split type AC of capacity 1.5/2.0 TR including taking out unserviceable part complete all as specified and directed.
S&F condenser/cooling coil suitable for 1.5/2.0 TR Air conditioner for suitable welding complete all as specified and directed.
M&L copper tube 3/4" as per site requiremnt and all as directed .
M&L copper tube 1/4" as per site requiremnt and all as directed .
S & F remote control unit suitable for 1.5 TR/2.0 TR split AC of any make as directed by Engr-IN-Charge .
M & L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920 RPM with super quality of copper wire of existing size complete with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as specified and directed.
M&L for charging of refrigerant gas R-134-A in window/Split Type Air conditioners 1.5/2.0 TR at site/contractor's workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe etc and testing complete all as specified and directed.
Taking out old U/S voltage stabilizers of capacity 0.5 KVA to 5 KVA from MES store/site and repair the same in MES work shop (if the transformer found burnt, the in same shall be re-winded in the workshop of contractor complete all as specified and directed.
S&F main relay 24 volts 25 Amps etc complete including taking out unserviceable part complete all as specified and directed.
S&F maint control circuit (PCB) etc including taking out unserviceable part complete all as specified and directed.
S&F in replacement sheet metal enclosure with metal clad socket and earth plug with one number MCB 20/32 Amp including connecting complete all as specified and directed. (Make: Havells/HPL/Legrand (MDS).
Taking out old unserviceable burnt sealed compressor from deep refrigerator/refrigerator and fixing only new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. Note: (i) Sealed unit compressor shall be measured and paid separately under supply only item. (ii) If any item required to made equipment functional like capillary.
Supply only new sealed compressor suitable for refrigerator/Deep freeser of capacity 165 Ltr/286 Ltr/310 Ltr complete all as specified and directed. Make: Kirloskar Copeland Emerson/Tecumesh/Whirlpool/Kelvinator/LT/Blue star or equivalent as approved by GE.
S&F relay suitable for refrigerator/Deep freezer 165/286/310 Ltr capacity including taking out unserviceable relay complete all as specified and directed. Make: Indfos/Godrej/Whirlpool or equivalent.
S&F over load protector suitable for refrigerator/Deep freezer 286/310 ltr capacity including taking out unserviceable over load protector complete all as specified and directed. Make: Indfos/Godrej or equivalent.
S&F thermostat suitable for refrigerator/Deep freezer 165/286/310 Ltr capacity complete all as specified and directed. Make: Indfos/Godrej/Whirl Pool or equivalent as approved by GE.
S&F PVC freezer door suitable for refrigerator of any make & capacity including taking out unserviceable part complete all as specified and directed.
S & F Magnetic rubber door gasket suitable for refrigerator of any make & capacity including taking out unserviceable rubber gasket complete all as specified and directed.
S&F Freezer temp control fan motor suitable for refrigerator of any make and capacity including taking out unserviceable part complete all as specified and directed.
S&F Timer Box of suitable for refrigerator double door of capacity 200/310 ltr including taking out unserviceable part complete all as specified and directed.
S&F fan motor suitable for deep freezer of any make and capacity complete inlcuding taking down existing unserviceable motor complete all as specified and directed.
M&L for Gas charging of refrigerators/deep freezers any capacity at site or contractor's workshop with necessary gas 134 gas, filter, anti moist and soldering/Brazing etc complete all as specified and directed.
Dismantling / taking out unserviceable burnt sealed unit of compressor from water coolers any make and capacity and fixing only sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply and charging refrigerant gas including testing all as specified and directed by engineer in charge Note: (i) Sealed unit compressor shall be measured and paid separately under supply only. (ii) All new replaced compressor unit shall be accompanied with a certificate from the manufacturer to the effect that the said compressor has been supplied by their authorized centre further a warranty of not less than 12 months of all such replacement. (iii) In case replaced compressor unit burnt shall be replaced including supply and recharging the refrigerant gas by the contractor without any extra cost. (iv) If any item required to made equipment functional like capillary, copper pipe etc is deemed to be included in quoted rate, (v) Necessary repair work shall be carried out at site/contractor's workshop/E/M yard the cost of handling/transporting the unit shall deemed be included in quoted rate.
Supply only new sealed unit compressor suitable for water cooler 40/80 Ltr complete all as specified and directed. Make: Kirloskar Copeland emerson/Tecumesh/Whirl pool/Kelvinator/Hitachi/Electrolux or equivalent as approved by GE.
Supply only new sealed unit compressor of capacity 40/80 Ltr complete all as specified and directed. Make: Kirloskar Copeland emerson/Tecumesh/Whirl pool/Kelvinator/Hitachi/Electrolux or equivalent as approved by GE.
Dismantling / taking out un-serviceable burnt FHP motor from water cooler and supply & fixing new FHP motor with suitable fan blade single phase 1/8 to 1/35 HP suitable for up to 150 Ltr capacity water coolers including testing complete all as specified and directed.
Taking out water cooler of any make and capacity from position and cleaning the complete condenser coil & storage tank with chemical base solution and soda water including servicing, oiling, of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position and testing complete all as specified and directed.
S&F Relay & OLP suitable for water cooler of any make & capacity complete all as specified and directed. Make: HI-tech/Classic or as per recommended by manufacture or equivalent as approved by GE.
S&F thermostat switch suitable for water cooler Make: Indfos or as per recommended by manufacture or equivalent as approved by GE complete all as specified and directed.
S&F in repair Push taps chromium plated brass suitable for water cooler capacity up to 150 ltr etc complete all as specified and directed.
S&F PVC flexible pipe heavy duty transparent 15mm/20mm dia (as per sample) etc complete all as specified and directed.
S&F in repair ball valve 15mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe etc complete all as specified and directed. (Weight min 142gms) Make Prayag or Symet
S&F in repair ball valve 20mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe etc complete all as specified and directed. (Weight min 142gms) Make Prayag or Symet
S&F running capacitor 4 MFD 230 volts 50 Hzs AC suitable for water cooler and desert cooler including taking out old capacitor complete all as specified and directed. Make: EPCOS/GC/Amcap or as per recommended by manufacture or equivalent as approved by GE.
M&L for gas charging of water cooler of any capacity and including refrigerant gas R-134A as directed at site or contractor workshop as directed including necessary work such as pipe line etc and testing complete all as specified and directed.
S&F condenser coil complete with copper capillary tube and aluminium fins for water cooler of any make and capacity complete all as specified and directed.
M&L for minor denting and painting of water cooler complete by spray painting super enameled with one coat of enamel paint after proper scraping of old painted surface complete all as specified and directed.
M&L for painting of desert cooler's external body, fan with one coat of synthetic enameled gray paint & internal body with synthetic enameled black paint complete with brush painting after proper dusting, cleaning and scrapping old painted surfaces complete all as specified and directed.
M&L for replacement of wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified and directed.
M&L for rewinding of stator of exhaust fan/kit fan 18" sweep 900 RPM of any make with super quality of winding copper wire of existing size complete with varnishing, backing, testing including painting with synthetic enameled paint of gray colour complete all as specified and directed.
Supply and replacement of submersible water lifting pump of capacity 1.25m head, 230 Volts complete all as specified and directed Make: Bansal or equivalent as approved by GE.
S&F Kit fan motor 450 mm sweep 1350/1400 RPM. Complete all as specified and directed. Make: Everest/Summer Cool/Khaitan.
M&L for writing MES No of window /split Type AC with Black painted minimum in 2 inch height 3mm bold capital letter written with the synthetic enamel paint in patter and style as approved by Eng-in-charge complete all as specified and directed.
M&L for writing MES No of water cooler /refrigerator/deep freezer with Black painted minimum in 2 inch height 3mm bold capital letter written with the synthetic enamel paint in patter and style as approved by Eng-in-charge complete all as specified and directed.
M&L for writing MES No of desert cooler with Black painted minimum in 2 inch height 3mm bold capital letter written with the synthetic enamel paint in patter and style as approved by Eng-in-charge complete all as specified and directed.
Taking down old and unserviceable sub main wiring ay size / type / core including earth wire complete with batten / conduit etc and making good the disturbed surfae to match the existing disturbed surface complete all as specified and directed.
M&L for sub main wiring with using two single core 6 Sqmm (FRLS ) copper conductor PVC unsheathed cable with and including PVC conduit (appropriate size) ISI Marked medium grade not less than 19mm dia concealed in wall for sub main wiring & connections including 4.0 Sqmm (FRLS) insulated multistranded unsheathed copper conductor cable used as a earth wire to common earth and connection to earth dolly all as specified. Note :- (i) Two runs of 6 sqmm (FRLS) and one run of 4.0 sqmm (FRLS) copper conductor cable & PVC conduit shall be measured as one unit length. (ii) Cutting chases for concealed wiring shall be made good by the contractor at his own cost with using Cement Mortar ( 1:4) / PCC ( 1:2:4) type B-0 (using 12.5mm graded stone aggregate) and surface finished to match the existing surface
M/s Acme Engineers and Contractors
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .