Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.2 LAccepted-AOC 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹13.5 L+₹2,960 (0.22%)Rejected-Finance | 2 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
25 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Fatehgarh
AGE (I) Fatehgarh
REPAIR AND MAINT OF STREET LIGHT FITTINGS , GARDEN LIGHTS AND GATE LIGHT FITTINGS AND OTHER CONNECTED WORKS AT FATEHGARH CANTT
2021_MES_477808_1
AGE(I) /FAT/ET-40 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) Fatehgarh
Refer to Tender Docus
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹33,000
Yes
16 Nov 2021
25 Sept 2021
28 Oct 2021
25 Sept 2021
25 Oct 2021
11 Oct 2021
25 Sept 2021 - 10 Oct 2021
60 days
Amount
Taking Down street light fluorescent tube/HPSV/HPMV/T-5 fitting/ LED Fitting of any capacity from pole, walls and dismantling for checking of unserviceable tubes, chokes, starter, ignitor, capacitor, bulbs, bulb holder and re-fixing in existing position after repairs for proper functioning Note :- Replacement of unserviceable parts with new parts as required for repair street light shall be measured and paid for separately under appropriate item of Sch À' as supply only
Supply only HPSV Lamp 70 watts complete all as specified and directed.
Supply only HPSV Lamp 150 watts complete all as specified and directed.
Supply only T5 Lamp 24 Watt complete all as specified and directed.
Supply only Electronic Ignitor for 70/150 watts complete all as specified and directed.
Supply only Condencer for 70 watts 15 MFD complete all as specified and directed.
Supply only Condencer for 150 watts 20 MFD complete all as specified and directed.
Supply only Ballast for 70 watts HPSV fittings complete all as specified and directed.
Supply only Ballast for 150 watts HPSV fittings complete all as specified and directed.
Supply only Electronic Ballast for 2x 24 watt T5 fittinghs complete all as specified and directed.
Supply only Holder for 70 watts HPSV fittings complete all as specified and directed.
Supply only Holder for 150 watts HPSV fittings complete all as specified and directed.
Supply only LED street light driver suitable for 30W LED street light complete all as specified and directed.
Supply only LED street light driver suitable for 45W LED street light complete all as specified and directed.
Supply only LED street light driver suitable for 70W LED street light complete all as specified and directed.
Supply only LED street light driver suitable for 90W LED street light complete all as specified and directed.
Supply only LED street light driver suitable for 120W LED street light complete all as specified and directed.
Supply only LED street light driver suitable for 250W LED flood light complete all as specified and directed.
S & F in replacement cable PVC insulated and PVC sheathed three core 1.5 sqmm copper conductor multistranded complete all as specified and directed.
M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 3.5/4 core and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and bolts and incl provn for fixing 01 Nos of single pole MCB SP 0.5-3Amp 'C' series inside the box and all specified and directed.
S&F in replacement of LED 35/36 Watt powder coated pressure die cast aluminium SMD street light with heat resistant toughened glass with lens complete all as specified and directed.
S&F in replacement of LED 60 Watt powder coated pressure die cast aluminium SMD street light with heat resistant toughened glass with lens complete all as specified and directed.
S&F in replacement of LED 70 Watt powder coated pressure die cast aluminium SMD street light with heat resistant toughened glass with lens complete all as specified and directed.
S&F in replacement of LED 100/110 Watt powder coated pressure die cast aluminium SMD street light with heat resistant toughened glass with lens complete all as specified and directed.
S&F in replacement of LED 120 Watt Flood light with powder coated pressure die cast aluminium housing , complete with all accessories complete all as specified and directed.
S & F in replacement of gate light 20W LED post top lantern with transparent diffuser etc including cable connections complete all as specified and as directed.
S & F in replacement of gate light 30W LED post top lantern with transparent diffuser etc including cable connections complete all as specified and as directed.
S & F in replacement of 9W decorative LED extruded aluminium bollard light with integrated driver etc including cable connections complete all as specified and as directed.
S & F in replacement pole mounted enclouser made of UV stabilized, FR grade special moulding compound having facility duriation base switching ON / OFF of capacity 05 KW, Three phase, with suitable size of FI clamps 02 Nos with the following accessories and all as directed. Make:- KAKATIYA ENERGY SYSTEM LIMITED Model No. SWADEEP - 66-5WK1P-Crono, or equivalent model as specified make approved by AGE(I) (i) Contactor 40 amps. = 01 No. (ii) MCB 40 Amps(SP),10 KA ,240 volts. = 02 Nos (iii) NATURESWITCH= 01 Nos
M&L for making hole of 15mm dia on LT pole at top and bottom (above coping) for drawing of street light connecting wire inside the pole as directed Note :- Hole on LT pole at Top and Bottom shall be measured as one job.
Taking down solar light fittings incl complete dismantling, checking, replacement of unserviceable spares and components as required and make the light fittings functional to give rated illumination incl cleaning the collector and refixing the same after repair/replacement of spare components complete with necessary electrical connection with suitable size of wire required length complete all as specified and as directed and re-fixing, re-connecting the same in existing position after carrying out necessary repair all as directed. Note:- (replacement of accessories shall be measured and paid separately under appropriate items of sch 'A' as supply only)
Supply only 10 Amps 12 volt solar charger complete all as specified and directed.
Supply only converter card suitable for 20 watt solar light fittings complete all as specified and directed.
Supply only solar panel glass sheet for solar light fitting collector plate thickness 6mm/5mm and length 4 feet width 2 feet complete all as specified and directed.
Supply only 20 watt solar light fitting as per existing make complete all as specified and directed.
Supply only acrylic cover suitable for 20 watt for solar light fitting complete all as specified and directed.
S & F PVC insulated and sheathed standered copper conductor 4.0 Sqmm three core for connection of street light fittings as as directed .
Supply only battery Brass terminal complete all as specified and directed.
M & L for battery checking by cleaning the terminal post, adding the petroleum gelly / grease, connecting the wires etc, complete all as directed .
Supply only Distiled water good quality for solar light battery complete all as specified & directed.
Supply only Batery 12V - 75Ah with all acessories complete all as specified and directed.
M & L dismantling carefully solar light fitting and pole, for shifting of poles including excavation in post holes (or similar holes ) each not exceeding 0.5 CUM, getting out, returning, filling in and ramming earth or borken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M & L for painting of solar light pole including frame and battery box cover complete with two coats of synthetic enamel paint of approved colour including removing of old paints, rust etc and painting / marking of Serial No complete all as specified and directed.
M&L for earthing complete with galvanized steel pipe electrode 40 mm bore, medium grade 2.50 meters length, buried in ground vertically to a depth n.less than 3.75 mtr below normal ground level and connected with GI earthing wire 4 mm dia by means of bolts, nuts and washers made of galavanised iron and steel earth wire protected by 15 mm bore light grade GI pipe incl PCC work as per sketch No - 2 of SSR Part -I (2009) pit cover slab of size 300x300x50 mm with handle as shown in drawing funnel, wire mesh 20 mm dia GI pipe medium grade for watering, charcoal and slat in alternate layers incl necessary earth work and excavation in soft/loose soil and removal etc incl testing complete all as specified and directed including tesing on complete all as specified and directed.
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft loose soil complete all as specified and as directed for foundation of stay etc.omplete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm.complete all as specified and directed
Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting pointomplete all as specified and directed
Supply and lay sand with approved fine grade around cable in cushioning for protection of under ground cable complete all as specified and as directed
Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
Laying only serviceable bricks obtained from the items specified here-in-before (i.e during taking out of under ground cable),laid flat dry, in trenches with width of the bricks laid to the axis of cable for protection of cable complete all as specified and as directed
Taking out unserviceable LT UG cable from trenches 6 Sqmm to 16 Sqmm size 2/4 core complete all as specified and as directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 16 Sqmm 4 core complete all as specified and as directed.
…ditto as above but for size 10 Sqmm 4 core …..ditto…..
…ditto as above but for size 10 Sqmm 2 core …..ditto…..
…ditto as above but for size 6 Sqmm 2 core …..ditto…..
S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of gate lights and similar work con- forming to Fe.290.Gde-E-165 indluding dismantling complete all as specified and as directed.
S B ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .