| 1 | L1₹39.6 LAccepted-AOC FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.8 L+₹3.2 L (7.96%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L2 | Rejected-Finance other than lowest one | |
| 3 | L3₹44.4 L+₹4.7 L (11.9%)Rejected-Finance B 13 ROOM NO 2 2 SHIVA PALM BEACH SOCIETY SECTOR4 NERUL WEST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance other than lowest one |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
29 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW NOFRA
GE NW NOFRA DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
ADDITION AND ALTERATION TO EXISTING STORM DRAIN AT NOFRA AND OTHER SANCTIONED WORKS FOR CERTAIN OTHER BUILDINGS UNDER GE NW NOFRA COLABA MUMBAI
2021_MES_440334_1
8878
Open Tender
Civil Works
Item Rate
240 days
MUMBAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹95,000
Yes
16 Jul 2021
4 May 2021
3 Jun 2021
4 May 2021
29 May 2021
17 May 2021
4 May 2021 - 15 May 2021
60 days
Amount
Note : The tenderer shall note before quoting his unit rate that mandatory safety measurement shall be adopted by the tenderer on site.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out hard/dense soil complete all as specified and directed by Engineer in charge.
Excavating in trenches,in hard soil (including top layer of bitumen/ road surface) n exc 1.5 m width n exc 1.5 m depth in hard/dense soil and getting out complete all as specified and directed by Engineer in charge.
Excavation in trenches n exc 1.5 m wide n exc 1.5 m deep in soft/ loose soil for foundation etc or for shaft, wells, manholes etc n exc 10 sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed by Engineer in charge.
Removing excavated soil not exceeding 50 m distance and depositing where directed at alevel n exc 1.5 metre above the starting point complete all as specified and directed by Engineer in charge.
Removing excavated material outside MD land exc. 1.50 km but n exc. 15 km and depositing where directed complete all as specified and directed by Engineer in charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.in any type of soil complete all as specified and directed by Engineer in charge. (Note : Quoted Rate shall include making good all bitimen , concrete road and footpath)
M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer in charge.
M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick wall, built in CM 1:4 complete all as specified and directed by Engineer in charge.
M&L for rendering, 10 mm thick in cement mortar 1:3 on brick work/concrete surface, finished even and smooth with out using extra cement on ceiling complete all as specified and directed by Engineer in charge.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work finished even and smooth (without using extra cement) ,complete all as specified and directed by Engineer in charge.
M&L for rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:6 finishing even and smooth without using extra cement and similar likes at any height including necessary scaffolding,complete all as specified and directed by Engineer in charge.
M & L PCC type B-2, 1:2:4 100 mm th using 40 mm graded aggregates as in sub bases, floors & pavings etc complete all as specified and directed by Engineer in charge.
M & L for 100 mm thick PCC 1:3:6 (40 mm graded aggregate) type C-2 in sub bases and sides of paver block complete all as specified and directed by Engineer in charge.
M&L for cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate as in coping of masonry wall including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork ,complete all as specified and directed by Engineer in charge.
M&L for providing precast cement concrete type B1 1:2:4 (20mm graded aggregate) in landings,cover slabs (for manholes etc) chullah hoods,chajjas,water troughs, mangers,shelves and similar articles with plain faces complete all as specified and directed by Engineer in charge.
M&L for Cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in surface channels, drains etc finished even and smooth without usig extra cement complete all as specified and directed by Engineer in charge.
M & L for PCC 1:4:8 type D2 ( 40 mm graded aggregates) as in foundation filling and mass concrete complete all as specified and directed by Engineer in charge.
M&L for Hardcore of gauge not exc 63mm broken stone or boulders but not exc 100mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rolled/rammed to a true surface for levelling the surfaces complete all as specified and directed by Engineer in charge.
M & L for Hardcore of gauge exc. 63 mm, of broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer in charge.
M&L for mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed by Engineer in charge.
M&L for Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles n exc 5 kg each complete all as specified and directed by Engineer in charge.
S & F for MS plate (CHEQUERRED) 5mm and over as in manhole cover fixed to angle iron frame with three Nos of hinges and 150mm handle complete all as specified and directed by Engineer in charge.
M&L for MS work (flat iron, round bar) for grill grating and framed brackets of angles, joist, channel, angle or tee sections fixed independently without connecting plates ect cut to shape (cut to ordinary length i.e within 20mm of the length indicated) drilled and cuntersunk for screws, including bending and welding as necessary, confirming to fe-410-0 or fe 310-0 including removing of old brackets and remove to store including necessary welding and nut & bolts including dismantlinng complete all as specified and directed by Engineer in charge.
S & F for Mild steel framed work (Fe-410-O) or (Fe-310-O) such as grill, gratings, sheet including welding to purpose made hinges etc with the ends of bars shoulders or riveted or forged into spikes framed guard bars railing and similar works fixing with bolt etc ,complete all as specified and directed by Engineer in charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar including cement mortar bedding and removing rubbish off the premises (outside MD land) complete all as specified and directed by Engineer in charge.
M & L for 10-12 mm thick Granite (of any type) work (table rubbed and polished edges of granite shoud be slightly moulded or rounded up) for wall lining (veneering to wall) in 20mm thick in cement mortar (1:3) and including of aerolite or adhesive as per requirement and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, including nosing of granite on top/asthetic view on top of granite complete all as specified and directed by Engineer in charge. (Note - Colour and shade of granite will be approved by GE)
M&L 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc complete all as specified and directed by Engineer in charge.
M & L for DGVT coloured vitrified tiles of area exc 0.36 Sqm, 10mm thick, laid in flooring, with & including 5mm thick adhesive of Ferrouscrete (FERRO-1122) / Fevimate XL- Pidilite / Gold star of Bal Endura or equivalant including necessary roughning of existing PCC flooring & levelling the floor if required, grouting the joints with white cement complete all as specified and directed by Engineer in charge.
M & L for DGVT coloured vitrified tiles of area exc 0.36 Sqm, 10mm thick, laid in skirting, over & including a backing coat of 10mm thick in CM 1:3, complete and making nosing at right angle corner, including levelling the wall, complete all as specified and directed by Engineer in charge.
M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick,set, jointed and pointed in neat cement slurry in floors laid over 15mm thick screed in CM 1:6, including dismantlig complete all as specified and directed by Engineer in charge.
M&L for plain cement concrete colour interlocking tiles 80 mm thick having glossy finish (colour and pattern approved by GE) strength not less than 350 Kg/Sq (tested as per IS 1237-1980) laid over and including 60 mm thick dry sand cushioning and voids filled with dry and surface compact, including compation by means of surface vibrator, complete all as manifacture instructions specified and directed by Engineer-in-Charge
M & L for Powder coated aluminium frame & shutter for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer in charge. (NOTE : Minimum thickness of powder coating shall be 50 micron)
S & F for 5.5mm thick ordinary quality glass, frosted on one side, in square exc 0.5 Sqm each pane, fixed to aluminium beading in aluminium window/ventilation etc complete all as specified and directed by Engineer in charge.
S & F for aluminium powder coated Grill (DECO grill, DG 103 of7.5 mm thick of M/s ELESAR, M/S Royal Grill, M/S National Grill Associated Profiles & Aluminium Ltd.) fixed with suitable 'F'/H' section(No. 8584)15.30 x 23.40 x 1.40mm(minimum), fabricated and riveted to aluminium windows/ventilator complete all as specified and directed by Engineer in charge.
S&F for aluminium wire cloth anodised 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples to aluminium window etc complete all as specified and directed by Engineer in charge.
S&F for 12mm thick customized and Modular Toughened glass as in openable door ifixed with patch fittings. Fixing of glass should be top to bottom including required corner patch/Bottom patch fittings and any suitable fittings including glass edges cutting with diamond blade and M/C polish, including stainless steel grade 304 or 316,rate including for drilling hole for patch fitting and spider fitting as required and locking arragement with 900mm SS handle etc complete all as specified and directed by Engineer in charge. Note :- Flooor spring will be measured saparately.
S&F for Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box ,main body with stainless steel cover,governing pivot made of brass,other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engineer in charge.
M&L for providing & fixing sun film / lamination 50 micron to glass panes,complete all as specified and directed by Engineer in charge. Make & shade all as approved by GE
S&F for 20mm dia aluminium decorative type powder coated curtain rod complete all as specified and directed by Engineer in charge.
S&F for aluminium decorative type powder coated brackets suitable for 20mm dia curtain rod complete all as specified and directed by Engineer in charge.
M&L for Metal frame suspended 12.5mm thick gypsum false ceiling including metal perimeter channel of size 0.50mm thick(having one flange of 20mm and another of 30mm and web of 27mm) along with the perimeter of ceiling, screw fix to block/brickwall/partition with the help of nylon sleeves then suspending with metal intermediate channel of size .80mm thick with two equal flanges each 15mm from the sofit at 900mm c/c with help of sofit cleats and Rawl plug etc complete all as specified and directed by Engineer in charge. (Design & pattern of ceiling as per approved by Engg-in-Charge or GE.)
Supply and fix in repair 5.5mm thick glass sheet ordinary quality one side frosted and glazing with oil putty fixed with beads exc 0.5sqm in each pane fixed to wooden frame or table in vertical position with required accessories etc complete all as specified and directed by Engineer in charge.
Dismantling boarding, any description, fixed in any position with screw. The rates are inclusive of dismantling of both soft and hard wood work and joinery and also allow for removal of dismantled material outside MD land etc complete all as specified and directed by Engineer in charge.
Taking down chowkhats or frame with shutters (without taking off shutters from frame) EACH not exceeding 1.50 SQM EACH complete all as specified and directed by Engineer in charge.
Taking down chowkhats or frame with shutters (without taking off shutters from frame) EACH exceeding 1.50 SQM but not exceeding 4 SQM EACH complete all as specified and directed by Engineer in charge.
M&L for 2nd class hard wood timber scantling clean wrought, timber framed & fixed complete all as specified and directed by Engineer in charge.
M&L for 2nd class hard wood timber scantling clean sawn, timber framed & fixed complete all as specified and directed by Engineer in charge.
M&L for 6mm thick ply wood, grade marine plywood,fixed with screws to timber frame work for cupboards complete all as specified and directed by Engineer in charge.
M&L for 12 mm thick ply wood, grade marine plywood,fixed with screws to timber frame work for cupboards complete all as specified and directed by Engineer in charge.
M&L for 18 mm thick ply wood, grade marine plywood,fixed with screws to timber frame work for cupboards complete all as specified and directed by Engineer in charge.
M&L for Continouous (piano) hinges, mild steel, bright finish or electrogalvanised width of flaps 30mm (when open) fixed in repairs complete all as specified and directed by Engineer in charge.
S & F for 150mm long extruded Brass handle fabricated type polished complete all as specified and directed by Engineer in charge.
S & F for 100mm Butt hinges, extruded brass, with mild steel hinge pin, bright polished type B-11 complete all as specified and directed by Engineer in charge.
S&F for 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, brass polished bright finished complete all as specified and directed by Engineer in charge.
M&L for veneer panelling of surface finish, colcur and pattern as approved, fixed with approved adhesive as per maker's instructions to plywood or wooden surfaces etc complete all as specified and directed by Engineer in charge.
M&L for two coats of french polishing on wooden surfaces of any description width or girth including cleaning and prepairing the surfaces including a coat of wood filler on old surfaces complete all as specified and directed by Engineer in charge.
M&L for 0.9mm thick decorative laminate type 1, of surface finish, colcur and pattern as approved, fixed with approved adhesive as per maker's instructions complete all as specified and directed by Engineer in charge.
S&F for Telescopy Channels, powder coated with ball bearings, suitable for Sliding SS plate racks 60 cm long standard width; fixed over 2nd class HW rectangulr fillet sectional area exc 3 & n exc 6 sqcm, clean swan secured with screws and the fillet fixed on cuddapah stone with screws, complete all as specified and directed by Engineer in charge.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer in charge.
M&L for preparation of new or previously untreated surfaces on steel based surfaces of any description exc 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of primer with smooth roller finish etc complete all as specified and directed by Engineer in charge.
M&L preparation of new plastered or unplastered surfaces and applying three coats of white wash on walls complete all as specified and directed by Engineer in charge.
Preparation of new plastered or unplastered surface by applying 3mm thick wall care putty on wall & and applying two coats of 'Lustre' paint of approved quality with Priming with alkali- resistant primer on wall etc complete all as specified and directed by Engineer in charge.
Preparation of new plastered or unplastered surface by applying 3mm thick wall care putty & and applying two coats of 'Lustre' paint of approved quality with Priming with alkali- resistant primer on ceiling etc complete all as specified and directed by Engineer in charge.
M & L for complete removal of existing treatment by scraping down wall surfaces and applying 3mm thick wall care putty on wall and applying two coats of 'Lustre' paint of approved quality with Priming with alkali- resistant primer on wall etc complete all as specified and directed by Engineer in charge.
M & L for complete removal of existing treatment by scraping down wall surfaces and applying 3mm thick wall care putty on ceiling and applying two coats of 'Lustre' paint of approved quality with Priming with alkali- resistant primer on ceiling etc complete all as specified and directed by Engineer in charge.
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc. ,complete all as specified and directed by Engineer in Charge.
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular boxes surfacing on wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :-
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
Material and Labour for point wiring complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly.
Supply and fix in repair Modular Switch, 6Amp, One way, 1 module ,complete all as specified and directed by Engineer in Charge.
Supply and fix in repair Modular Switch, 16Amp, One way, 1 module ,complete all as specified and directed by Engineer in Charge.
Supply and fix in repair Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module ,complete all as specified and directed by Engineer in Charge.
Supply and fix in repair ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals ,complete all as specified and directed by Engineer in Charge.
Supply and fix in repair Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module ,complete all as specified and directed by Engineer in Charge.
Supply and fix in repair Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module ,complete all as specified and directed by Engineer in Charge.
Supply and fix in repair Modular white cover plate with Frame 3 Module ,complete all as specified and directed by Engineer in Charge.
Supply and fix in repair Modular white cover plate with Frame 6 Module ,complete all as specified and directed by Engineer in Charge.
Supply and fix in repair Modular metal flush box 3 module,complete all as specified and directed by Engineer in Charge.
Supply and fix in repair Modular metal flush box 6 module ,complete all as specified and directed by Engineer in Charge.
Supply and fix in repair LED baton integral aluminium body with white acrylic cover of lumen output 1800-2400 LUX , 300 to 6500 Kelvin with accessories internally prewired and including connecting up with twin core twisted flexible copper conducter cable of suitable size complete all as specified and directed by Engineer in Charge
Supply and fix in repair MCB, DB, SPN 8 way double door with protection type IP-42 with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size ,complete all as specified and directed by Engineer in Charge, as approved comprising following :-
(a) MCB SPN 40 Amps 240 Volts-01 No (B Series)
(b) MCB SP 6- 32 Amps 240 Volts - 06 Nos (B Series)
Unitech Enterprises
Anil Industrial Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .