Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC DESHBANDHU PARA SILIGURI 734 004 | DARJEELING | WEST BENGAL | 734004 | L1 | Accepted-AOC Being L1 is accepted | |
| 2 | L2₹6.7 L+₹21,899 (3.38%)Rejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance Being L2 is rejected | |
| 3 | L3₹7.0 L+₹47,664 (7.36%)Rejected-Finance ATUL PRASAD SARANI SILIGURI 734006 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | L3 | Rejected-Finance Being L3 is rejected |
Tender Value
Refer Docs
EMD Value
₹12,960
Closing Date
13 Aug 2021, 12:00 pmClosed
Executive Engineer, Darjeeling Electrical Division
Opposite of PWD Inspection Bungalow Kachari Road, Siliguri 734001, District Darjeeling
Supply and Installation of LED Glow signboard for COVID BLOCK-1 and COVID BLOCK-2 to identify the covid Block within the campus of NBMCH ,Sushrutanagar, Dist- Darjeeling.
2021_WBPWD_339072_1
WBPWD/EE/DED/e-NIT- 36 of 2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
SILIGURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹12,960
29 Sept 2021
6 Aug 2021
16 Aug 2021
6 Aug 2021
13 Aug 2021
6 Aug 2021
Amount
Supply & fixing metallic sign board made of 3 mm thick ACP sheet ,finished with approved metallic colour as back ground (colour approved by department) & fixed on M.S. structure. The all side fabricated with 20mmx 3mm square bar with required fixing arrangement as frame (size=20’-2”x 4’2"),(20’-2”x 4’2"),(10'-2"x 3'-2"),3x[6'-2"x3'-2") & (8'-2"X3'2")
Supply & fixing outdoor LED sign board made of 3 mm thick back side fabricated aluminium sheet for protection of the board of inside wiring. size as per enclosed LED sign board details.thick aluminium sheet finished with required fixing arrangement as frame (size=20’-2”x 4’2"),(20’-2”x 4’2"),(10'-2"x 3'-2"),3x[6'-2"x3'-2") & (8'-2"X3'2")
Supply & Fixing special type of imported solid Acrylic letter (thickness 3mm raised .5 inch above ACP)fixed on ACP sheet.All side each letter glows or emits light uniformly .Calculation based on all dimensions.( The Matter for the signage is "COVID BLOCK-1"---letter size 12 inchX 62", with Arrow direction letter size 6inchx 48 inch, Letter thickness 2inch Each.
Supply & Fixing special type of imported solid Acrylic letter (thickness 3mm raised 1.5 inch above ACP)fixed on ACP sheet.All side each letter glows or emits light uniformly.Calculation based on all dimensions.( The Matter for the signage is "COVID BLOCK-2"---letter size 12 inchX 62", .,with Arrow direction letter size 6inchx 48 inch .Letter thickness 2inch Each
Supply & Fixing special type of imported solid Acrylic letter (thickness 3mm raised 1.5 inch above ACP)fixed on ACP sheet.All side each letter glows or emits light Uniformly.Calculation based on all dimensions.( The Matter for the signage is "COVID BLOCK-2 &COVID BLOCK-1 "---letter size 12 inchX 51", .,with Arrow direction letter size 6inchx 42 inch .Letter thickness 2inch Each
Supply & Fixing special type of imported solid Acrylic letter (thickness 3mm raised 1.5 inch above ACP)fixed on acp sheet.All side each letter glows or emits light uniformly.Calculation based on all dimensions.( The Matter for the signage is "COVID BLOCK-1 "---letter size 21 inchX 197", .,DEPARTMENT OF ANESTHESIOLOGY,NBMC&H--- letter size 9inchx 229 inch .Letter thickness 2inch Each
Supply & Fixing special type of imported solid Acrylic letter (thickness 3mm raised 1.5 inch above ACP)fixed on Acp sheet.All side each letter glows or emits light uniformly.Calculation based on all dimensions.( The Matter for the signage is "COVID BLOCK-2 "---letter size 21 inchX 197", .,DEPARTMENT OF ANESTHESIOLOGY,NBMC&H--- letter size 9inchx 229 inch .Letter thickness 2inch Each
Supply & Fixing special type of imported solid Acrylic letter (thickness 3mm raised 5 inch above ACP)fixed on 2mm thick acrylic sheet.All side each letter glows or emits light.Calculation based on all dimensions.( The Matter for the signage is "COVID CLINIC"---letter size 10 inchX 63", COVID BLOCK-2----- letter size 7 inchX 56"inch, with Arrow direction letter size 6inchx 48 inch, Letter thickness 2inch Each. (2 Nos)
Supply & Fixing special type of imported solid Acrylic letter (thickness 3mm raised 5 inch above ACP)fixed on ACP sheet.All side each letter glows or emits light Uniformly.Calculation based on all dimensions.( The Matter for the signage is "COVID CLINIC"---letter size 15 inchX 87", NBMC&H----- letter size 9 inchX 56"inch, Letter thickness 2inch Each.
Supply & fixing of LED inside the metallic letters on ACP board , The Specification of the is given below. A)LED backlit b)LED white -Samsung/GE(Tetra mini max ) c)life :70,000 burning hours d)power supply:20Amp e)power consumtion -1.5Watt per module f)input:230V, output: 12V DC g)1ft=3 Module.
Power Supply: Input: 100V, AC to 240V AC,4A /2A ; 50/60 HZ Output:DC 12V, 30A Constant Power Supply(Make:Philps/samsung Driver)
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required a) 25 mm Dia
Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary(Without LoopBox).
Metal Sign Board should be fixed on the top of the Roof Pillars on M.S channel and suitable size and number of stay rigidly by nuts, bolts etc. as per direction of E.I supply and fixing M.S fabrication box for holding rectanguler shape LED board of size (size=20’x 4’) with powder coted 30mm X 30 mm X4 mm MS angle and MS flat iron (30mm X 30mm) for holding the facia.
All material Transportfrom Siliguri Town to Medical callage during Lock down and Fixing the same to the site by 20mm X3 mm Flat bar and allied scrow, nuts And bolt also paint with Ro Primer as per consultation with EIC.
Supply and delivery of DIN -type HRC fuse (Make:ABB) of following sizes: a) 100A
Add 12% GST
Add 1% Labour Welfare Cess
Terms & condition: If any defect is arrise within one year, contractor should repair this without any cost within two working days.
ORIENT ENGINEERING WORKS
RAJESH ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .