Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.6 L+₹1.4 L (9.89%)Rejected-AOC 88 GIRRAJ NAGAR KALWAD ROAD JOTHWARA JAIPUR 302012 JAIPUR CITY NORTH RAJASTHAN 302012 | JAIPUR | RAJASTHAN | 302012 | L2 | Rejected-AOC L2 | |
| 3 | L3₹17.6 L+₹3.4 L (24.2%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹17.6 L+₹3.5 L (24.5%)Rejected-AOC 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-AOC L4 | |
| 5 | L5₹18.4 L+₹4.2 L (29.9%)Rejected-AOC FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | L5 | Rejected-AOC L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
Kanjoli line Bharatpur
Repair/Maintenance of summer and winter cooling appliance and central air cooling system at RMS Dholpur
2022_MES_538341_1
8175/E8
Open Tender
Civil Works
Item Rate
270 days
GE Bharatpur
as per tender document
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹40,000
Yes
29 Aug 2022
15 Jul 2022
22 Aug 2022
15 Jul 2022
15 Aug 2022
30 Jul 2022
18 Jul 2022 - 28 Jul 2022
Amount
Taking out and servicing of window/split type air conditioner cap- 1.5/2.0 Ton incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air/water jet from grill, screen filter at indoor unit and condenser fin, evaporator fin at outdoor unit using detergent solution or chemical solution complete all as specified and as directed . Note: Spare parts shall be measrured & paid separately under respective items.
M&L for flushing, pressurising the system , leakage testing, vacuumization and charging with refrigerant R -410/R-22/R134 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for folowing capacity split type air conditioner complete all as specified and as directed.
1.5 Ton Capacity
2.0 Ton Capacity
S & F in replacement of following items for window/ Split AC of any capacity: (a) Compressor for AC Capacity- 1.5 Ton for window/split AC (as per site requirement) as per existing make/LG/Voltas/Carrier/Tecumesh
Compressor for AC Capacity- 2.0Ton for window/split AC (as per site requirement) as per existing make/LG/Voltas/Carrier/Tecumesh
Starting Capacitor 80-100 / 100-120 MFD, Make : TESLA/ Godrej or Equivalent make approved by GE. as mentioned in Appx
Running Capacitor 36 MFD/ 45 MFD, Make : TESLA/ or Equivalent make approved by GE. as mentioned in Appx
Screen filter of air conditioner of cap - 1.5 / 2.0 TR as per existing make.
Starting relay suitable for window and split type AC. Make: SRIRAM or Equivalent make approved by GE
Thermostatic switch suitable for window/split type AC 1.5/2.0 Ton capacity of existing make.
Fan motor with fan blade unit suitable for 1.5 Ton capacity window /split type air conditioner of existing make.
Condenser's fan motor with blade suitable for split type air conditioner
Electronic panel board / PCB with display of Airconditioner cap- 1.5TR/2TR .
Plastic water drain hose pipe, 15mm dia and 2mtr long for spit type AC .
Remote control operating device for Window/Split type AC of 1.5/2.0 Ton with 02 Nos of pencil battery of existing make.
Pencil batteries for remote of split/window AC.Make: duracell
Copper tubes of size 4/8, 1/2 inch with aerofoam NBR rubber insulation tube .
Copper tubes of size 3/8,5/8, 1/4 inch with aerofoam NBR rubber insulation tube . (Note for Srl item No 5 to 5.2 here in before: Fixing shall be measured and paid under respective item)
stand for outdoor unit of existing size complete all as specified and directed.
Taking out old unsv and S & F indoor unit complete of existing make and size for split AC 1.5 TR as directed by Engr-in-charge
Taking out old unsv and S & F outdoor unit complete of existing make and size for split AC 1.5 TR complete with condensing coil, Fan with motor & compressor unit etc for smooth function as directed by Engr-in-charge
Shifting of AC of any type of AC capacity 1.5/2.0 Ton complete in & out door unit including taking out brackets, pipe line and fixing insulating pipelines including brazing of copper tubes, testing/commissioning complete, the shifting of service connection and voltage stabilizer to the new location complete all as specified and as directed Note: The rates shall also include transportation, civil work and making good to the disturb surfaces.
Taking out and servicing of electric driven single phase water cooler of any cap /any type incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air/water jet using detergent solution or chemical solution ,leakage testing of refrigerant,storage tank leakage testing complete all as specified and as directed . Note: Spare parts shall be measrured & paid separately under respective items.
Painting of water coolers of Cap - 80/120 or 150/150 Ltrs by cleaning old deteriorated exterior surface and necessary prepartion of surface by scrapping rust, grease, dirt etc before applying two coats of synthetic enamel paint of Make : Asian Paints Ltd ( Ist quality) or equivalent of approved colour by using spray painting technique to match with existing colour at existing location complete all as specified and directed by Engr in charge.
Ditto all as per Srl Item No 8 here in before but of Water cooler capacity 40/80 Ltrs.
M & L for flushing, pressurising the system , leakage testing vacuumization and charging with refrigerant R-134A/R-407/R-22 at apprporiate pressure after rectifying leakage in the system vaccumising and dehydration including testing as per standard practice at site for water cooler of cap 80/120 or 150/150 ltrs of Make : Bluestar/Usha/Voltas complete all as specified and directed by Engr in charge.
All as per serial item No-10 above but of Water cooler capacity 80/40 Ltrs.
S & F in replacement of following items for water cooler of any capacity:
Compressor unit for water cooler 120/80 Ltrs of existing make or any other make apporved by GE mentioned in Appx.
Compressor unit for water cooler 40/80Ltrs of existing make or any other make apporved by GE mentioned in Appx.
Condenser fan motor with fan blade for water cooler of any Cap of existing make or any other make apporved by GE mentioned in Appx.
Capacitor 25/35 MFD, ISI marked.
Thermostat with knob as per existing size and make.
Relay with overload protection assembly
Magnetic rubber gasket of top cover as per existing size and make
Drain water tray of stainless steel by brazing/soldering the joints, vent pipes, outlet etc as per existing size and make
Pencil type strainer alongwith capillary tube suitable as per existing size and make.
Float valve PVC 15mm bore, heavy duty. (Make: Prayag, Surya)
chromium plated push cock size 15 mm suitable Make: Liberty/Onida/CSON
PVC flexible pipe size 40 mm dia with necessary clamping with jubli clips for drain water tray
PVC connection of size 15 mm dia 450mm long
M&L for storage tank leakage repair through brazzing/welding/silicon gel fiiling of any capacity water cooler complete all as specified
Taking out and servicing of electric driven single phaserefrigerators and deep freezer of any cap incluiding cleaning/removing all dust/mud, oil and other foreign particle with compressed air/water jet using detergent solution or chemical solution ,leakage testing of refrigerant,freezer storage leakage testing complete all as specified and as directed . Note: Spare parts shall be measrured & paid separately under respective items.
M&L for flushing, pressurising the system , leakage testing, vacuumization and charging with refrigerant R -22/R-134A/R-407 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for Refrigerator/deep freezer of Cap upto 190 Ltrs complete all as specified and as directed.
All as per serial item No. 38 here –in before but of capacity 200 Ltr to 280 Ltrs
All as per serial item No. 39 here –in before but of capacity above 280 Ltrs
S & F in replacement of following items for refrigerator/deep frezer of any capacity:
Compressor unit for Regrigerator of cap 165-195Ltrs of existing make or any other make apporved by GE mentioned in Appx.
Compressor unit for Regrigerator of cap 200-320Ltrs
Compressor unit for Regrigerator/Deep freezer of cap 200-400Ltrs
Starting relay suitable for existing refrigerator. Make: SRIRAM or equivalent make approved by GE
Thermostatic switch auto defrost type with knob suitable for existing refrigerator
Bulb inside the refrigerator suitable for existing refrigerator
Magnetic rubber door gasket suitable for existing refrigerator
Push type door switch suitable for existing refrigerator
Door lock with two keys suitable for existing refrigerator
Overload protector suitable for refrigerator . Make: INDFOSS/DANFOSS or equivalent make approved by GE
Strainer pencil type alongwith capillary tube suitable for refrigerator as per existing capacity
Electronic PCB for 260-400 Ltr refrigerator /Deep freezer
Taking out and servicing of desert cooler of any capacity i.e. checking of desert cooler fan motor, submersible pump, socket point, PVC connections,Fan blade, wooden chips etc including noting the complaints in compliant register complete all as directed by Engineer - in - Charge. Note: Spare parts shall be measrured & paid separately under respective items.
Cutting burnt winding of fan motor of size upto 450mm sweep and rewinding with super enamelled copper winding wire and replacing gun metal bush shaft.complete
M&L for painting of desert cooler inner and outer surface with spray gun using one coat of red oxide and two coat of anti corrosive synthetic enamaled paint of approved brand as directed by Engr-in-charge
S & F of Fan Motor copper wound 16/18" sweep, 3 Speed single phase 230V AC supply complete with Blade (Make: Khaitan/Crompton Greaves/Bajaj/Cool Home/Marathon)
M & L for MS Bracket with mounting ring of cooler fan motor and mounting clamps/legs of existing size/model
S & F of PVC submersible Pump complete single phase 230V AC supply for desert cooler, 1 meter head or suitable to existing desert cooler. Make: Khaitan/Crompton Greaves/ Bajaj/ Summercool
M & L for Side panel/shutter made out of 20 SWG GI sheet as per existing design and approved including handles (2 Nos.) duly welded / riveted
M & L for Bottam tank made out of 20 SWG GI sheet as per existing unserviceable tank
M & L for Top of the Desert Cooler made of 20 gauge GI Sheet riveted /bolted to match with existing.
S & F of PVC water distribution cup with PVC elbow and pipe for any size of cooler
S & F of Capacitor cap- 4/6 MFD, suitable for desert cooler as per existing size. Make: L&T/Epco/Khaitan
S & F of Piano switch 5 amps one way
S & F of 3 pin plug top 5 Amp. Make
M & L for twin core 1.5 Sqmm copper conductor wire for internal wiring
S & F of Float valve PVC 15mm bore, heavy duty.
S & F of PVC connection 45 cm long.
S & F of PVC connection 60 cm long.
M & L for Wooden chips pad of suitale size for 03 side shutters of desert cooler min 600gm in weight.
M & L for PVC insulated and sheathed flexible 1100 volts grade 3 core multistranded copper conductor of size 2.5 sqmm.
S & F of 3 pin plug top 15 Amp. Make : ANCHOR complete
S & F of brass stop cock / Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 15 mm bore pipes complete
S & F of brass stop cock Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed suitable for 20 mm bore pipes complete
Taking out old unsv parts from Desert cooler and supply & fix new parts of desert cooler to make functioning of the same. (a) Desert ccoler body complete with front grill made out of GI sheet of overall dimension of desrt cooler 690X690X1020mm with mounting frame for fixing of cooler fan motor ,Air grill of suitable size made out of 0.5mm PGI sheet including GSS arrangement with a knob for easy and smooth movement, Front & Side panel made out of 1mm thick PGI sheet of suitable size and shape, Water tank height should not less than 11 inch made out of 1mm thk PGI sheet, wooden chips pad for three side shutters,Service cord of 3 Core copper wire 1.5 Sqmm with plug top 5 Amp length not less than 2 metres, Electronic fan dimmer 1000 watts AC 230 Volt for controlling the fan speed.
Supply & Fixing plywood 6mm thick with white mica sheet duly fixed in windows with screws for ventilation opening for desert cooler as per existing size complete all as specified and directed by Engr in Charge.
M&L for fixing and grouting of MS Stand (adjustment type) suitable for desert cooler of cap 3000/4000CFM made out of angle iron section complete with two coats of synthetic enammled black paint over a coat of red oxide primer all as specified and directed by Engr in Charge.
S&F in replacement GI pipe, 15 mm bore, medium grade, ISI marked with fittings laid in trenches or fixed to walls, ducts, floors etc incluiding necessary excavation and earth work complete for desert cooler/water cooler connections all as specified and directed by Engr in charge. (Make: Surya/Prakash/Tata/Jindal)
Ditto all as per Srl Item No 12 here in before but of 20mm bore
S&F modular enclosure of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 volts. Make- L&T, Havells, Legrand complete all as per specified by Engr-in-charge.
M&L concealed submain wiring complete with 6 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 6 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories.
M&L concealed submain wiring complete with 4 Sqmm single core multi standred PVC insulated and sheathed cable FRLS copper conductor two runs and one run of 4 Sqmm copper cable for earth continuity conductor in and including drawn through PVC conduit size not less than 20 mm dia with all PVC accessories.
Taking down u/s air washer, cleaning and removing dust particles inside the chamber of air washer container, disconnecting all electrical wires with proper termination and insulating the naked wires if any, removing unsv FASD starters etc and refitting the all removed and items after repairing/replacing at site as per the existing position all as specified and directed by Engr-in-Charge
M&L for dismantling the joints of each compartment of duct and cleaning of duct from air washer outlet to cadet's room opening of any length by using anti scaling spray, scrapping the foreign materials deposited on internal wall of the duct, opening the outlet grills, blowing air with high pressure through duct to get the deposited foreign materials by using external heavy duty compressor, applying oil spray inside the duct to prevent the sheet from corrosion with very thin layer, connecting all the compartments as per existing position, replacing gasket at all joints, all as specified ans as directed by Engineer-in-Charge.
M&L for replacing insulating layer over the duct to prevent from heat or any extreme weather by using synthetic foam or synthetic rubber and wrapping with garnison net or square threaded net around the insulation by using suitable solvent or compound to stick permanenty after dismantling the old UNSV insulation layer and scrapping the surface and cleaning properly before applying the new insulation layer all as specified and as directed by Engineer-in-Charge
M&L for checking all the water pipeline connections, repairing leakages from PVC storage tank to air washer system storage tank, welding the cracks or hole or fabricating with new sheet for 40mm GI drain out pipes, replacing end plug of drain system and over f;low system of bottom mount tank, checking the condition of float valves, cleaning the valve and refitting, leakage testing and rectifying in all respect in pipeline and existing tank and making fucntional at all cost all as specified and as directed by Engineer-in-Charge
S&F in repairing the following accessories of Air Washer:
DOL Starter of capacity 5HP suitable for three phase 3HP motors complete with on off push buttons and over current relay. Make-Legrand/L&T.
Rewinding 5HP motor of blower fan motor by using super enamelled copper conductor wire solid in nature, grade 1 quality, incl dismantling/assembling and transporting etc. and refixing after repairing and replacing of UNSV parts such as housing/nuts bolts etc
S&F bearing of motor suitable for 5HP Make CG, in repairing incl taking out old UNSV , applying suitable grease and test run etc all as specified and directed.
supply and fix in repair cassete filter of size 2x2 feet complete all as specified
Supply and fix motor fan belt of suitable size genuine part from the Air systems all as specified and directed.
Supply and fix in repairing compartment door of Mild Steel of size 27.5 inch x 55.5 inchx 1 inch, with AHU door locking arrangements, hand lock and key, painting of metal primer and two coat super enamel paint with existing colour and finish includng removing of UNSV door etc all as specified and directed.
Supply and fix submersibble pump set of 32 watt of output 3200 L/H , 220V, 50 Hz suitable for a height of 2.95 mtr all as specified and directed by engineer-in-charge
S&F PVC float valve of size 20mm as required on site including rod and ball in replacement of old UNSV one and testing all as specified and as directed by Engineer-in-Charge
S&F PVC pipe in replace ment of UNSV and broken of size 25mm with suitable compound for jointing over the pump outlet including all kind of accessorie all as specified and as directed by Engineer-in-Charge
S&F of PVC valve 25mm size along with PVC union in replacement of old UNSV one all as specified and as directed by Engineer-in-Charge
S&F in replacement of air filtration pad( compact honey pad), 1.22m x 1.22m corrugated, thin sponge layer consisting, of paper membrane as one layer, net cloth as second layer and foam as third layer suitable to filter the inlet air entering into the air washer system while running the plant of dimension 1.22m x 1.22m of thichness 8 inch or as per existing size suitable for air washer system including fixing pad, nuts bolts and accessories etc all as specified and as directed by Engineer-in-Charge.
S&F PVC float valve of size 15mm as required on site including rod and ball in replacement of old UNSV one and testing all as specified and as directed by Engineer-in-Charge
Material and labour for Rotational moulded polyethylene water storage tanks 1000Ltr (cylindrical vertical with closed top) hoisted and fixed in position with float valve all as specified in SSR Part I
M&L pipe galvanized iron medium grade of 25mm bore complete with all fittings and fixed complete to walls ,and ceiling or laid in floors, jointed tested and commissioned complete for connection from under ground sump to tanki of air cooling system all as specified and directed ISI marked.
S&F 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
M&L for PCC (1:2:4) type B2 with using 40mm graded aggregate as in foundation and mass filling concrete for poles/Stay wires/ LT panel boards/foundation of PVC tank and in addition where ever directed including demolition of existing complete all as specified and directed by Engr-in-Charge .
S&F Voltage stabilizer for automatic operation, single phase, naturally air cooled indoor type, designed for input variation between 170V to 250V with output voltage stabilized at 230V, with accuracy +/- 2.5% of capcity 5KVA fixed on wall or any location as directed including connected accessories all as specified and as directed by Engineer-in-Charge.
S&F Voltage stabilizer for automatic operation, single phase, naturally air cooled indoor type, designed for input variation between 170V to 250V with output voltage stabilized at 230V, with accuracy +/- 2.5% of capcity 4KVA fixed on wall or any location as directed including connected accessories all as specified and as directed by Engineer-in-Charge.
labour only for day to day complaints of all cooling appliance AC,water cooler ,refrigerator,desert cooler,deepfreezer etc including servicing any type and size making them functional with minor repair & replacement as required at site complete all as specified and directed by engineer-in-charge
Taking out old Existing U/S MCCB from LT panels/ Feeder piller of following capacity and replace with new MCCBs without damaging the LT panel board or any assets associated with the installation. Make Havells/L&T/ABB/Schneider. Supply and fix MCCB 4 Pole, 415 V, with adjustable type 160 Amps with breaking capacity 36 KA all as specifed and all as directed by engineer-in-charge
Supply and fix MCCB 4 Pole, 415 V, with adjustable type 250 Amps with breaking capacity 36 KA all as specifed and all as directed by engineer-in-charge
Supply and fix MCCB 4 Pole, 415 V, with 63 Amps with breaking capacity 25 KA all as specifed and all as directed by engineer-in-charge
Supply and fix MCCB 4 Pole, 415 V, with adjustable type 100 Amps with breaking capacity 25 KA all as specifed and all as directed by engineer-in-charge
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 50 Sqmm 3.5core for air cooling system including taking out old U/s all as specified and directed by Engineer in Charge.
-ditto- as per Ser No-41 here-in-before but of size 25 sqmmx 4 core
-ditto- as per Ser No-42 here-in-before but of size 16 sqmmx 4 core
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying LT UG cable, and getting out in hard disintegrated layer complete all specified/directed
Removing excavation soil at a distance not exc 50 m and deposited where directed complete all as directed
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as directed
Supply and laying of unburnt Sub class B Bricks in trenches over the LT/HT cables for the protection of cables, laid across the length all as specified and as directed by Engineer-in-Charge.
M &L local river sand for bedding and sand cushioning of all HT/LT UG cable all as specified and directed by Engr-in-Charge
Shree Karni Electrovision
M/S MAKHIJA TRADERS
S S TRADERS
Ganga Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .