Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.7 LAccepted-AOC KRISHNAPUR RAJBARI PURBA BARDHAMAN PIN 713104 | PURBA BARDHAMAN | PURBA BARDHAMAN | WEST BENGAL | 713104 | L1 | Accepted-AOC Quoting Lowest Rate | |
| 2 | L2₹1.0 Cr+₹2.1 L (2.12%)Rejected-Finance GR 8 ADDA 1 FLOOR CITY CENTRE DURGAPUR 713216 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | 713216 | L2 | Rejected-Finance Quoting
Higher rate | |
| 3 | L3₹1.0 Cr+₹2.2 L (2.25%)Rejected-Finance 0 KALIKAPUR KALIKA PUR CHAMPAHATI SOUTH 24 PARGANAS WEST BENGAL 743330 | 24 PARAGANAS SOUTH | WEST BENGAL | 743330 | L3 | Rejected-Finance Quoting
Higher rate |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
3 Nov 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintendent Engineer
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Repair and Renovation of 3 nos. of Boys Students Hostel BH I BH II and BH III in the campus of Burdwan Medical College Purba Bardhaman
2023_WBPWD_591729_1
WBPWD/SEWEC /BED /NIQ-113 /2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Purba Bardhaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹2.0 L
Office of the Superintending Engineer, Western Ele
22 May 2025
12 Oct 2023
6 Nov 2023
12 Oct 2023
3 Nov 2023
18 Oct 2023
12 Oct 2023 - 17 Oct 2023
17 Oct 2023
Amount
DISTRIBUTION WIRING
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
b) Average run 8 Mtr
c) Average run 9 Mtr
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average run 8 mtr
Average run 9 mtr
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish
Average run 8 mtr
Average run 9 mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish
On Board
Average run 7.5 mtr
S&drawing 1.1 kv single core stranded FR PVC insulated &unsheated single core stranded cupper wire (approved make)of the following sizes prelaid poly pipe. & by the Gifish wire & making necy connection as required.Make : Gloster/KEI/Polycab
a) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC (From HTPN DB to SPN DB)
b) 2X 56/0.3( 4 sqmm) + 1 X 36/0.3( 2.5 sqmm) as ECC ( From HTPN DB to Power Plug/AC )
b) 2X36/0.3(2.5 SQMM)+1*22/0.3(1.5SQMM) as ECC (For Power Plug & Computer Point)
c) 3 X 22/0.3( 1.5 sqmm)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. Make : Gloster/KEI/Polycab
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 3 mm thick Polythene pipe (without earth continuity wire) by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles incl. S&F of following pipe
i. 19 mm dia pipe
ii. 25 mm dia pipe
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
i. 2.5 sq.mm.
ii. 4 sq.mm.
iii. 6 sq.mm.
PLUG & SOCKETS (Normal)
Supply & Fixing 240 V, 2 nos. 6A, plug socket with separate 2 nos 6 A Piano key type switch (Make : Goldmedal/Legrand/Panasonic) on sheet metal switch board embedded in wall incl. S & F 175x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover, incl. S & F 3 nos copper bar( Ph, N, E) and making necessary connections as required.
Supply & Fixing 240 V, 16/20A, plug socket with separate 16/20 A Piano key type switch (Make : Goldmedal/Legrand/Panasonic) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 1 nos. 6A and 1 No. 16 A plug socket with separate 1 nos. 6 A and 1 No 16 A Piano key type switch with indicator & 16A kit-kat flush type fuse (Make : Goldmedal/Legrand/Panasonic) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board including with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 200 x65mm MS (16SWG) switch board with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the 200 mm x 150 mm x 65 mm sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works along with Supply and fixing 2 no 16 A Piano Key type Switch and 2 no 16 A plug Socket.
Power Distribution board
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment upto Make:- Legrand/Schneider/Siemens
8 way Enclosure (607914) upto 160 A
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
a) 6 way Enclosure (607716)
b) 4 way Enclosure (607715)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
a) 2 + 14 way Enclosure (607712)
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
6-32 A SP MCB
40 A SP MCB
63 A TP MCB
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.
Cable for Distribution Board and other Auxiliaries
Supply & Delivery of following size 1.1 kV.gr.XLPE insulated 1100V Grade as per IS 7098 (part 1) 1988 armoured sheathed Aluminium conductor cable. [Make - Polycab/ KEI/ Gloster )
i) 4 Core 120 sqmm
ii. 4 core 95 sqmm
iii. 4 core 50 sqmm
v. 4 core 25 sqmm
Laying of cable above on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
i. 4 core 120 sqmm
ii. 4 core 95 sqmm
iii. 4 core 50 sqmm
v. 4 core 25 sqmm
Laying of cable as below, after cutting wall and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
ii. 4 core 95 sqmm
iii. 4 core 50 sqmm
v. 4 core 25 sqmm
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
ii. 4 core 95 sqmm
iii. 4 core 50 sqmm
v. 4 core 25 sqmm
Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for
b) 4 Core 120 Sqmm
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
4 core 95 sqmm
Laying of two cables in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
i) 4 core 120sqmm
S & F compression type brass cable gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entryof XLPE/PVC armoured cableas & Finishing the end of the following XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials:
ii. 4 core 120sqmm
iv. 4 core 95 sqmm
iii. 4 core 50 sq. mm.
v. 4 core 25 sq. mm.
i. Charges for cutting floor of RCC incl. mending the damage as per GS (Civil Work)
ii. Charges for Pitch road cutting incl. mending the damage as per GS ( Civil Work)
iii. Charges for Concreate mixture 1:1.5:3 ( Cement: Sand: Stone chips ) as per GS ( Civil Work)
iv. Charges for cutting morrum soil/ soft soil/ concrete incl. mending the damage as per GS ( Civil Work)
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With out iron support 200x50x1.25mm (18SWG)
Fittings and fixer
Supply and Delivery of 240V 50 Hz 48" sweep (1200 mm),High speed 380 rpm, Air delivery 230 m³/min , power input 55 W, ceiling fan complete with down rod,Canopy,fork etc. and Fixing the ceiling fan complete with blades, canopy, fork, rubber bush etc.With minimum 03 years warrenty from final billing period (Make- Orient Summer Breeze Pro / Usha/ Crompton)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
S& delivery 240V. 50 Hz. 300 mm. Sweep 920 r.p.m. Heavy Duty AC Exhaust Fan (As per EPC make) Warrenty atleast 02 years from final billing period
S& delivery 240V. 50 Hz. 920 r.p.m. Heavy Duty AC Exhaust Fan (As per EPC make) Warrenty atleast 02 years from final billing period
a) 9"(23 cm) Exhaust Fan
b) 12" (30 cm) Exhaust Fan
Fixing only 300 mm exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
a) 9"(23 cm) Exhaust Fan
b) 12" (30 cm) Exhaust Fan
Supply & Fixing GI louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for
a) 9"(23 cm) Exhaust Fan
b) 12" (30 cm) Exhaust Fan
Fixing of single LED tube light fitting attached with the wall with 2 No. “V” type MS clamp whose one side inserted within the wall and other side connected with the suitable size of bolts and nuts incl. S&F"V” type MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. with S & F 2x24/0.20 mm unsheathed stranded 1.5 sqmm copper wire of 0.5mt. length. incl. 2nos mounting kit.
Fixing of single/double LED tube light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side inserted within the ceiling reinforcement and other side connected with the suitable size of bolts and nuts incl. S&F EI conduit “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. with S & F 2x24/0.20 mm flexible copper wire of 1.10 mt. length. incl. 2nos mounting kit.
Supply and delivery of following LED Tube fittings
a) Single Fittings, Make- Philips, cat no.- TMC 502 P 1xT-LED 22W P3241 incl. 1x 18W LED tube (PC body)/ Crompton/ Surya. Having warranty atleast 03 years from final billing period
b) Double, Make- Philips, cat no.- TMC 502 P 2xT-LED 22W P3242 incl. 2x 18W LED tube (PC body)/ Crompton/Surya Having warranty at least 03 years from final billing period
S&D LED type tube lamp 18/20 Watt Polycarbonate Body with inbuilt driver and Metal Heat Sink having length 1200mm, T8, Iumen Output - Min. 2100 Lumen (Make: Philips / Crompton / Wipro / Surya). [03(Three) years on-site Warranty Certificate is to be provided].
S & F of 9 Watt Led lamp. (Make- Philips/ Surya/ Crompton)
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.
Supplying & Fixing 18 W LED bulk head light fitting with die cast aluminium housing & frosted glass on wall/ceiling incl. accessories. Warranty 03 years from final billing period. (Make- Philips/ Surya/ Crompton)
Panel work, Rising Main & Main switch/Change Over
Supplying and fixing 400A, 415V, TPN SFU with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc. incl. cable end box and Interconnection with Main bus bar of LT panel through Cu Bar of - 4 x 50 x 5mm with all accessories as per direction of EIC. (Make:- L & T/ABB/Seimens)
Supplying and fixing 415V, TPN on load front operated Changeover switch open execution type in SS enclosure/cubical with nuts bolts etc. (Make:- L & T/ABB/Seimens)
Feeder Pillar Supply & Errection of suitablesize out door type both side opening sheet steel piller box of 3.15 mm thick CRCA sheet with trapizium top cover (5 mm thick) with ventilation arrangement with both side door arrangement hinged type,with mechanical locking aarangement & in built handle pcc & brick foundation of 20" with plasterwith neat cement finish etc. with central hollow with filling of fine sand at a height of 1.5 ft from G.L & bellow 1.5 ft one pcc ( 4" thick) on sand filling (6" thickness) Pillerbox should have 2 (two) coatof synthetic enemel paint powedercoated over RO Primer with mechanical locking arrangement with pad lock & key (3 no key) with it incl. 2 no earth terminal on it. The Piller box should have two part type (front & back side opening) with comprising of the following.
Painting : Panel should be properly degreased, derusted before phospheting. Alkalyed melamine epoxy based powder coated paint to be done by using 7 tank process with minium thickness of 70 micron avg. Shade will be Pebble Grey No. RAL 7032 both inside and outside. Continious GI Earth bus of size 40 x 6 mm to be provided at a hight of 100 mm from the bottom and brought outside of the panel of 50 mm. Depth of the panel : As per direction of EIC. C P R I - Type Test Report for the Panel Board (similar type from Manufacturer)
Termination : Incoming cable termination Bus should be suitable for termination of requisite nos. Ar/Al XLPE/PVC cables. Outgoing feeder terminals should be as per rating.
System Voltage : 415V, 50Hz, RYBN. Control wiring cable size : 1.5 sqmm PVC FR Cu multistrand flexible wire with proper socketing with PVC sleeve & identification ferruling. CT Secondary wiring to be done with 2.5 sqmm PVC FR Cu multistrand flexible wire. (Make- RR Kabel /Gloster / Polycab/ KEI).
Incoming :- 415V, 400A, TPN open execution type, SDFU with 3 nos. HRC Din type fuse . Make: L&T/ ABB/ Siemens -- 1nos. (Interconnecting Cu bar between SFU and main Bus Bar -4 x 50x5mm
Bus Bar Arrangement :- S & F 415V, 600 A current carrying capacity electrolytic grade tinned copper BBC (4 x (2x 40x5) mm) in size for neutral & phases. The entire bars are insulated with PVC heat sinkable sleeve of suitable size & colour as per direction of E.I.C. -- 1 set.
Outgoing :- a) 415V, 200 A, TPN open execution type, SDFU with 3 nos. HRC Din type fuse . Make: L&T-- 4nos. (Interconnecting bus Cu between SFU and main Bus Bar - 4 x 25 x 5mm b) 415V, 63A, TPN open execution type, SDFU with 3 nos. HRC Din type fuse . Make: L&T-- 2 nos. (Interconnecting Cu wire between SFU and main Bus Bar - 4 x 25 sq.mm. cu wire) c) 415V, 32A, TPN open execution type, SDFU with 3 nos. HRC Din type fuse . Make: L&T-- 2 nos. (Interconnecting Cu wire between SFU and main Bus Bar - 4 x 16 sq.mm. cu wire)
Metering, Control or indication wires shall be nearly bunched separately and adequately supported so as to prevent stresses and strain on termination. Foundation for Panel :- Suitable placed and as per panel fabrication Brick Foundation with neat Cement Plastering with hollow for cable entry point. Design should be proper for adequate load capacity. (as directed by EIC)
Hostel Building Panel: SITC of indoor type L.T. Panel Board with SFU as Incomer and SFU as outgoing feeders in a suitable transportable unit, ready for operation on being installed in a fixed position. The Panel board shall be Self-supporting, fully Compartmentalized, Incomming / Outgoing SFU Compartment Should be Seperate, floor mounted, indoor type, dust and vermin proof (IP 42), Incoming and outgoing cable entry from bottom / top end at rear side / side cable alley. Gland plate (2 mm thick) should be two part detachable type. The switch board shall be fabricated from 1.6 mm thick (16 SWG) CRCA sheet and base channel will be 50mm x 25mm x 5mm (painted with Black Japan after derusting). The doors shall be removable type mounted on hinge with key locking arrangement for each compartment.
Painting : Panel should be properly degreased, derusted before phospheting. Alkalyed melamine epoxy based powder coated paint to be done by using 7 tank process with minium thickness of 70 micron avg. Shade will be Pebble Grey No. RAL 7032 both inside and outside. Continious GI Earth bus of size 40 x 6 mm to be provided at a hight of 100 mm from the bottom and brought outside of the panel of 50 mm. Depth of the panel : As per direction of EIC. C P R I - Type Test Report for the Panel Board (similar type from Manufacturer)
Termination : Incoming cable termination Bus should be suitable for termination of requisite nos. Ar/Al XLPE/PVC cables. Outgoing feeder terminals should be as per rating.
System Voltage : 415V, 50Hz, RYBN. Control wiring cable size : 1.5 sqmm PVC FR Cu multistrand flexible wire with proper socketing with PVC sleeve & identification ferruling. CT Secondary wiring to be done with 2.5 sqmm PVC FR Cu multistrand flexible wire. (Make- RR Kabel /Gloster / Polycab/KEI).
Incoming :- 415V, 200 A, TPN open execution type Change over, SDFU with 3 nos. HRC Din type fuse . Make: L&T/ ABB/ Siemens -- 1no. (Interconnecting Cu bar between SFU and main Bus Bar - 4 x 25 x 5 mm
Bus Bar Arrangement :- S & F 415V, 315A current carrying capacity electrolytic grade tinned copper BBC 4 x 40 x 5mm in size for neutral & phases. The entire bars are insulated with PVC heat sinkable sleeve of suitable size & colour as per direction of E.I.C. -- 1 set.
Outgoing :- a) 415V, 125A, TPN open execution type, SDFU with 3 nos. HRC Din type fuse . Make: L&T-- 6nos. (Interconnecting bus Cu between SFU and main Bus Bar - 4 x 20 x 5 mm) d) 415V, 32 A, TPN open execution type, SDFU with 3 nos. HRC Din type fuse . Make: L&T--3 nos. (Interconnecting Cu wire between SFU and main Bus Bar - 4 x 25 sq.mm. cu wire)
Metering, Control or indication wires shall be nearly bunched separately and adequately supported so as to prevent stresses and strain on termination. Foundation for Panel :- Suitable placed and as per panel fabrication Brick Foundation with neat Cement Plastering with hollow for cable entry point. Design should be proper for adequate load capacity. (as directed by EIC)
Compound Lighting
Supply and delivery of LED Street Light 230V, 70Watt, 6500/5700K, Luminous efficassy ≥120 with all necessary connection. [Make: PHILIPS/ CROMPTON/ Wipro/ Surya]. 05 years manufacturer warranty certificate is to be provided.
Fixing only outdoor / street light type LED light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
SITC of digital programmable time switch (L&T/ Legrand/ABB/ Siemens/ Schneider) on SS enclosure incl. S&F SS enclosure(250x 200x 105 mm) with IP 65 having hinged type SS top cover with 4 mm thick rubber gasteket lining railway type locking arrangement with DIN rail incl.earthing attachment as per direction of EIC.
Supply and delivery of 1.1 KV grade,XLPE Insulated & Sheathed Armoured Aluminium Conductor cables. [Make:POLYCAB/RR KABLE /Gloster/KEI]
2 Core 10 sqmm
Laying of cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
2 Core 10 sqmm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
2 Core 10 sqmm
S & F compression type brass cable gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entryof XLPE/PVC armoured cableas & Finishing the end of the following XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials:
2 Core 10 sqmm
Earthing & GI pipe
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as by ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages No. 4 SWG
Supplying & fixing medium gauge 100 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required with necessary socketing/welding.
DURGAPUR POWER
GHOSH ENTERPRISE
technical_1247514.pdf
PDF • 0.07 MB
techsummary_1247514.pdf
PDF • 0.09 MB
finance_1247514.pdf
PDF • 0.11 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_1247514.pdf
PDF • 0.09 MB
NIQ113.PDF
PDF • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .