Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹25.0 L+₹28,844.60 (1.17%)Rejected-Finance 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹25.8 L+₹1.1 L (4.39%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L5₹26.4 L+₹1.7 L (7.02%)Rejected-Finance 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | L5 | Rejected-Finance Other than lowest | |
| 5 | L5₹27.9 L+₹3.2 L (12.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/S OM Enterprises L4 | Jain Traders L9 | m/s rudraksh enterprises L6 | Balaji Associates L5 | M/S R.S. CONTRACTOR & SUPPLIER L7 | SIYA ASSOCIATES L2 | TRIVENI ASSOCIATES L8 | M/s Tomar Builders L11 | S S TRADERS L10 | M/S falcon Builder L3 | Mani Control System L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/colour/plaster to match with the existing location spot complete all as specified & directed. | 1,250 | Per Point | 10 ₹12,500 | 39 ₹48,750 | 5 ₹6,250 Lowest | 5 ₹6,250 Lowest | 35 ₹43,750 | 11 ₹13,750 | 50 ₹62,500 | 10 ₹12,500 | 5 ₹6,250 Lowest | 20 ₹25,000 | 10 ₹12,500 |
| 2.00 | M&L for point wiring concealed type with 1.50sqmm PVC FRLSH insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5sqmm FRLSH PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed. | 300 | Per Point | 400 ₹1,20,000 | 449 ₹1,34,700 | 490 ₹1,47,000 | 350 ₹1,05,000 | 255 ₹76,500 | 641 ₹1,92,300 | 450 ₹1,35,000 | 450 ₹1,35,000 | 400 ₹1,20,000 | 415 ₹1,24,500 | 250 ₹75,000 Lowest |
| 3.00 | - do- all as per item No-2 here in before but with 2.5 sqmm PVC FRLSH wire for one socket out let 3/5 pin, 5/6 Amps controlled by 1 one way on the same board with other switches complete all as specified & directed. | 130 | Per Point | 220 ₹28,600 | 249 ₹32,370 | 120 ₹15,600 | 350 ₹45,500 | 299 ₹38,870 | 211 ₹27,430 | 400 ₹52,000 | 100 ₹13,000 | 80 ₹10,400 Lowest | 200 ₹26,000 | 300 ₹39,000 |
| 4.00 | - do- all as above item No-2 but one socket out let with 2.5 sqmm PVC FRLSH wire for 3/5 pin, 5/6 Amps controlled by one 1way switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed. | 150 | Per Point | 450 ₹67,500 | 549 ₹82,350 | 680 ₹1,02,000 | 400 ₹60,000 | 355 ₹53,250 | 641 ₹96,150 | 400 ₹60,000 | 600 ₹90,000 | 400 ₹60,000 | 400 ₹60,000 | 300 ₹45,000 Lowest |
| 5.00 | - do- all as per item No-2 here in before but using 2.5 sqmm PVC FRLSH insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed.
NOTE-For item No. 2 to 5-: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers.
(ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A.
(iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B) However minimum size of conduit shall be 20 mm dia (medium grade) | 120 | Per Point | 500 ₹60,000 | 549 ₹65,880 | 680 ₹81,600 | 425 ₹51,000 | 450 ₹54,000 | 691 ₹82,920 | 550 ₹66,000 | 600 ₹72,000 | 550 ₹66,000 | 500 ₹60,000 | 300 ₹36,000 Lowest |
| 6.00 | Supply & fix commissioning and testing of Modular AC Box unit compressing of ON/OFF switches socket 3 pin socket outlet with plug top modular type made out of white polycarbonate, fire retardant, UV stabilized power unit internally pre-wired with suitable size copper conductor cable with overload protective device (MCB) complete unit fixed in single polycarbonate housing with inlet & outlet cable port suitable for AC & geyser operated at single phase, 240 volts, 50 Hz AC supply of capacity 25 Amps load bearing capacity complete all as specified and directed. | 40 | Each | 600 ₹24,000 | 749 ₹29,960 | 650 ₹26,000 | 500 ₹20,000 | 555 ₹22,200 | 911 ₹36,440 | 1,000 ₹40,000 | 600 ₹24,000 | 700 ₹28,000 | 300 ₹12,000 Lowest | 360 ₹14,400 |
| 7.00 | Supply & fix in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one No. MCB SP of capacity 25 Amps 240 volts complete all as specified & directed. | 20 | Each | 1,000 ₹20,000 | 849 ₹16,980 | 650 ₹13,000 | 500 ₹10,000 | 655 ₹13,100 | 611 ₹12,220 | 700 ₹14,000 | 700 ₹14,000 | 1,100 ₹22,000 | 1,300 ₹26,000 | 180 ₹3,600 Lowest |
| 8.00 | Supply and fix in replacement switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed. | 580 | Each | 30 ₹17,400 | 24.49 ₹14,204.2 | 23 ₹13,340 | 25 ₹14,500 | 55 ₹31,900 | 21 ₹12,180 Lowest | 30 ₹17,400 | 30 ₹17,400 | 25 ₹14,500 | 50 ₹29,000 | 25 ₹14,500 |
| 9.00 | Supply and fix in replacement socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed. | 280 | Each | 40 ₹11,200 | 39 ₹10,920 | 65 ₹18,200 | 35 ₹9,800 | 110 ₹30,800 | 21 ₹5,880 Lowest | 35 ₹9,800 | 80 ₹22,400 | 40 ₹11,200 | 70 ₹19,600 | 180 ₹50,400 |
| 10.00 | Supply and fix in replacement switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed. | 120 | Each | 120 ₹14,400 | 149 ₹17,880 | 85 ₹10,200 | 90 ₹10,800 | 89 ₹10,680 | 81 ₹9,720 | 150 ₹18,000 | 45 ₹5,400 Lowest | 110 ₹13,200 | 85 ₹10,200 | 45 ₹5,400 Lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
27 May 2026, 6:00 pmClosed
Maj Dinoop Kumar
GE (W) Agra
REPAIR REPLACEMENT OF INTERNAL ELECTRIC WIRING AND CONNECTED WORKS OF OTM ACCN UNDER AGE E/M (WEST) OF GE (WEST) AGRA
2026_MES_761167_2
8012/1169/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Agra
Please refer tender document
9 documents required · 9 mandatory
₹500
GE (W) Agra
₹70,000
25 Jul 2026
7 May 2026
3 Jun 2026
7 May 2026
27 May 2026
21 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/colour/plaster to match with the existing location spot complete all as specified & directed. | - | Per Point | - | - |
| 2 | M&L for point wiring concealed type with 1.50sqmm PVC FRLSH insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5sqmm FRLSH PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed. | 300 | Per Point | - | - |
| 3 | - do- all as per item No-2 here in before but with 2.5 sqmm PVC FRLSH wire for one socket out let 3/5 pin, 5/6 Amps controlled by 1 one way on the same board with other switches complete all as specified & directed. | 130 | Per Point | - | - |
| 4 | - do- all as above item No-2 but one socket out let with 2.5 sqmm PVC FRLSH wire for 3/5 pin, 5/6 Amps controlled by one 1way switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed. | 150 | Per Point | - | - |
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender.pdf
Tender Documents • 0.47 MB
BOQ_855671.xls
BOQ • 3.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .