Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC MANEGAON DIWAN BADA KHAMARIA JABALPUR M P PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹34.8 L+₹6,045 (0.17%)Rejected-Finance 403 NARSINGH NAGAR RANJHI JABALPUR MP PIN 482005 | JABALPUR | JABALPUR | MP | 482005 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹38.2 L+₹3.5 L (9.97%)Rejected-Finance R O 24 GOKALPUR MAIN ROAD JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Third lowest amount quoted | |
| 4 | L4₹40.4 L+₹5.7 L (16.3%)Rejected-Finance | L4 | Rejected-Finance Fourth lowest amount quoted | |
| 5 | L5₹42.0 L+₹7.2 L (20.8%)Rejected-Finance 1432 2 UDAI NAGAR NO 2 POST OFFICE JABALPUR MP 482009 | JABALPUR | MADHYA PRADESH | 482009 | L5 | Rejected-Finance Fifth lowest amount quoted |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
27 Aug 2022, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2022_MES_539381_1
8468/E8
Open Tender
Civil Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D a (i)
9 documents required · 9 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹84,000
Yes
12 Sept 2022
25 Jul 2022
29 Aug 2022
25 Jul 2022
27 Aug 2022
10 Aug 2022
25 Jul 2022 - 1 Aug 2022
Amount
UNRESTRICTED AREA SCHEDULE
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work using old bricks with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. (only for soak well).
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering on other than fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed.
Taking out removing rubbish and including CM 1:3 broken glass coping on top of walls.
M&L for PCC 1:2:4 B-2 Type using 20 mm graded stone aggregate cement concrete in surface channels and drains.
M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed.
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in columns, pillars, piers, posts and struts.
M&L for RCC 1:2: 4 B-1 type using 20 mm aggregate as foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc, basement slabs, under-reamed piles and mass complete all as specified and dircted.
M&L for rough finished formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or batter.
Formwork to sides of pillars, posts, struts, piers, columns, and stanchions Rough finished surfaces of concrete Square, rectangular or polygonal complete all as specified and directed.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM internal dia of pipe 150 mm complete all as specified and directed.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM internal dia of pipe 300 mm complete all as specified and directed.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM internal dia of pipe 450 mm complete all as specified and directed.
M & L Cement concrete 1:4:8 type D2 150 mm bore for concrete bed to drain pipes including packing under, and haunching against the side of pipes complete all as specified and directed.
M & L Cement concrete 1:4:8 type D2 300 mm bore for concrete bed to drain pipes including packing under, and haunching against the side of pipes complete all as specified and directed.
M & L Cement concrete 1:4:8 type D2 450 mm bore for concrete bed to drain pipes including packing under, and haunching against the side of pipes complete all as specified and directed.
S & F reinfored concrete pipes, 150 mm bore class NP2 laid Jointed complete with collars.
S & F reinfored concrete pipes, 300 mm bore class NP2 laid Jointed complete with collars.
S & F reinfored concrete pipes, 450 mm bore class NP2 laid Jointed complete with collars.
M&L 100mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate.
M&L for Mild Steel TMT bar 8 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
M&L Fromwork rough finished to Soffiting of suspended slab such as roof slab, floor slabs landing and similar work not exceeding 200 mm thickness as directed by Engr-in-Charge.
M&L for RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall, beam and column in floors, roofs, landings, balconies, canopies and in shelves and similar work complete all as specified and directed.
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
Demolition of cement concrete reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation & mass concrete.
S&F Rolled mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, Doors etc to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails & guides) & hanging; also fastening & fixing complete GDE Fe410-0 or Fe 310-O.
M&L for precast cement concrete louvres and jallies, 35mm thick (mea sured solid), including all mouldings including necessary foam work complete all as specified and directed.
M&L Mild steel round bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to GD-I. IS-432 (Part I).
Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface.
M&L PCC in foundations, filling and mass concrete type C2 (1:3:6) using 40 mm graded stone aggregate.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion & making good disturbed ground embedded in Concrete, brick work, masonry, etc complete all as specified and directed.
S&F Mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc, conforming to Fe 410-0 or Fe 310-0.
M&L Mild steel round bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to GD-I. IS-432 (Part I).
S&F Mild steel screw bolts 12mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt n exc 10cm.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire.
Supply only Chain link MS galvanised fencing, any size or type.
S&F, Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured).
Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165.
M&L for Steel Concentrina coil of super profile of 600 mm dia stress in position hot dipped Galvanised steel wire coated with CLR ante corrosive paint making dimond shape with the help of dove tail clip (18 SWG) the coil fixed with razor wire at points were coil touch the bottom layer wire with help of hog rings(14 SWG) with and including all fittings like fastener, clips, luggs rings etc as approved by Engr-in Charge complete and all as specified and directed .
Material & Labour preparation of old plastered or un-plastered surface including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots remove complete existing surface up to mother surface approved by GE than applying one coat of cement base paint on walls complete all as specified and directed.
Material & Labour preparation of old plastered or un-plastered surface including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on walls complete all as specified and directed.
Preparation of new plastered or un-plastered surface and applying three coat white wash walls complete all as specified and directed.
M&L two coat of syntetic enamel paint over new steel surface of any description over 10cm in width or grith not otherwise described over one coat red oxide primer incl preparation of surfaces complete.
M&L two coat of syntetic enamel paint over new steel surface of any description n exc 10 cm in width or girth not otherwise described over one coat red oxide primer incl preparation of surfaces complete.
M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and directed.
M&L for colour rubber moulded Chequered cement concrete tiles 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with white cement and pigments complete.
M&L for sand filling under floors or in foundation, pavement including watering and consolidation complete all as specified and directed.
M&L for Machine pressed precast cement concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade.
Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering & well ramming in layers n exc 25 cm in soft/loose soil.
Removing excavated soil n exc 50m & depositing where directed at a level n exc. 1.5 m above the starting point.
Hardcore of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface.
M&L PCC in roof kerbs of mud stops, rounded or chamfered on edges type B1 (1:2:4) using 20 mm graded aggregate
RESTRICTED AREA SCHEDULE
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work using old bricks with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. (only for soak well).
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering on other than fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed.
Taking out removing rubbish and including CM 1:3 broken glass coping on top of walls.
M&L for PCC 1:2:4 B-2 Type using 20 mm graded stone aggregate cement concrete in surface channels and drains.
M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed.
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in columns, pillars, piers, posts and struts.
M&L for RCC 1:2: 4 B-1 type using 20 mm aggregate as foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc, basement slabs, under-reamed piles and mass complete all as specified and dircted.
M&L for rough finished formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or batter.
Formwork to sides of pillars, posts, struts, piers, columns, and stanchions Rough finished surfaces of concrete Square, rectangular or polygonal complete all as specified and directed.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM internal dia of pipe 150 mm complete all as specified and directed.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM internal dia of pipe 300 mm complete all as specified and directed.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM internal dia of pipe 450 mm complete all as specified and directed.
M & L Cement concrete 1:4:8 type D2 150 mm bore for concrete bed to drain pipes including packing under, and haunching against the side of pipes complete all as specified and directed.
M & L Cement concrete 1:4:8 type D2 300 mm bore for concrete bed to drain pipes including packing under, and haunching against the side of pipes complete all as specified and directed.
M & L Cement concrete 1:4:8 type D2 450 mm bore for concrete bed to drain pipes including packing under, and haunching against the side of pipes complete all as specified and directed.
S & F reinfored concrete pipes, 150 mm bore class NP2 laid Jointed complete with collars.
S & F reinfored concrete pipes, 300 mm bore class NP2 laid Jointed complete with collars.
S & F reinfored concrete pipes, 450 mm bore class NP2 laid Jointed complete with collars.
M&L 100mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate.
M&L for Mild Steel TMT bar 8 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
M&L Fromwork rough finished to Soffiting of suspended slab such as roof slab, floor slabs landing and similar work not exceeding 200 mm thickness as directed by Engr-in-Charge.
M&L for RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall, beam and column in floors, roofs, landings, balconies, canopies and in shelves and similar work complete all as specified and directed.
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
Demolition of cement concrete reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation & mass concrete.
S&F Rolled mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, Doors etc to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails & guides) & hanging; also fastening & fixing complete GDE Fe410-0 or Fe 310-O.
M&L for precast cement concrete louvres and jallies, 35mm thick (mea sured solid), including all mouldings including necessary foam work complete all as specified and directed.
M&L Mild steel round bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to GD-I. IS-432 (Part I).
Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface.
M&L PCC in foundations, filling and mass concrete type C2 (1:3:6) using 40 mm graded stone aggregate.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion & making good disturbed ground embedded in Concrete, brick work, masonry, etc complete all as specified and directed.
S&F Mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc, conforming to Fe 410-0 or Fe 310-0.
M&L Mild steel round bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to GD-I. IS-432 (Part I).
S&F Mild steel screw bolts 12mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt n exc 10cm.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire.
Supply only Chain link MS galvanised fencing, any size or type.
S&F, Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured).
Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165.
M&L for Steel Concentrina coil of super profile of 600 mm dia stress in position hot dipped Galvanised steel wire coated with CLR ante corrosive paint making dimond shape with the help of dove tail clip (18 SWG) the coil fixed with razor wire at points were coil touch the bottom layer wire with help of hog rings(14 SWG) with and including all fittings like fastener, clips, luggs rings etc as approved by Engr-in Charge complete and all as specified and directed.
Material & Labour preparation of old plastered or un-plastered surface including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots remove complete existing surface up to mother surface approved by GE than applying one coat of cement base paint on walls complete all as specified and directed.
Material & Labour preparation of old plastered or un-plastered surface including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on walls complete all as specified and directed.
Preparation of new plastered or un-plastered surface and applying three coat white wash walls complete all as specified and directed.
M&L two coat of syntetic enamel paint over new steel surface of any description over 10cm in width or grith not otherwise described over one coat red oxide primer incl preparation of surfaces complete.
M&L two coat of syntetic enamel paint over new steel surface of any description n exc 10 cm in width or girth not otherwise described over one coat red oxide primer incl preparation of surfaces complete.
M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and directed.
M&L for colour rubber moulded Chequered cement concrete tiles 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with white cement and pigments complete.
M&L for sand filling under floors or in foundation, pavement including watering and consolidation complete all as specified and directed.
M&L for Machine pressed precast cement concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade.
Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in soft/loose soil.
Returning, filling in, including spreading, levelling, watering & well ramming in layers n exc 25 cm in soft/loose soil.
Removing excavated soil n exc 50m & depositing where directed at a level n exc. 1.5 m above the starting point.
Hardcore of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface.
M&L PCC in roof kerbs of mud stops, rounded or chamfered on edges type B1 (1:2:4) using 20 mm graded aggregate
Schedule of credit amount of Rs. 83,930. to be deducted during AOC
LAL SINGH & SONS
m/s R K SETHI
RASTOGI BUILDERS
M/S RAJ BUILDERS
R R VISHWAKARMA CONSTRUCTION CO
sunil traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .