SPECIAL REPAIR TO REPLACEMENT OF OH ACSR CONDUCTOR INTO LT AB CABLE AND ALLIED ITEMS AND PROVN OF SPECIALIST SHOP INSTRUMENT FOR TECHNICAL TRADESMEN AT MIRAN SAHIB UNDER GE JAMMU
2024_MES_646866_1
GEJC-84/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE Jammu
₹88,800
Yes
25 Apr 2024
19 Mar 2024
17 Apr 2024
19 Mar 2024
15 Apr 2024
2 Apr 2024
Amount
B/R Portion: - Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard / dense soil complete all as specified and directed.
Material and labour for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in mass concrete in foundation complete all as specified and as directed.
Material and labour for brick work with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Material and labour for brick work with sub class 'B' old size bricks, straight or curved on plan to any radius built in half brick thick wall cement mortar (1:4) complete all as specified and as directed.
Material and labour for RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in foundations / plinth beams complete all as specified and as directed.
Material and labour for RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in columns complete all as specified and as directed.
Material and labour for RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in chajjas complete all as specified and as directed.
Material and labour for reinforced cement concrete (1:2:4) type B-1 mix (using 20mm graded crushed stone aggregate) as in lintel beams, roof beams supported on walls as for roof slabs, lintel etc complete all as specified and as directed.
Material and labour for reinforced cement concrete (1:2:4) type B-1 mix (using 20mm graded crushed stone aggregate) as in slabs and shelves etc complete all as specified and as directed.
Material and labour for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation complete all as specified and as directed.
Material and labour for formwork to sides and soffits of roof beams, tie beams etc also splays between floors and beams etc complete all as specified and as directed.
Material and labour for formwork to sides of pillars, posts, struts, piers, columns and stanchions square / rectangular complete all as specified and as directed.
Material and labour for formwork to soffits of slabs including supports, overhangings etc for fair finished surfaces of concrete complete all as specified and as directed.
Material and labour for formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed.
Material and labour for formwork to edges of roof slab of thick not exceeding 20cm wide and as in similar work complete all as specified and as directed.
Material and labour for TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Material and labour for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Material and labour for TMT bars 5 to 8 mm dia as in stirrups, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed as in stirrups.
Material and labour for 15mm thick rendering in cement mortar (1:6) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour rendering 15mm thick on fair faces of brick / concrete surfaces built in cement mortar (1:4), finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 5mm thick rendering in cement mortar (1:3) on fair faces of brick work or concrete surfaces on ceiling finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for preparation of new surface and applying two coats of oil bound distemper new plaster surface over 1mm thick putty complete all as specified and as directed.
Material and labour for preparation of new surface and applying two coats of exterior emulsion / weather proof paint over a coat of primer over and including 1mm thick putty on plastered surfaces complete all as specified and as directed.
Material and labour for preparation of surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in each layers hard / dense soil complete all as specified and directed.
Removing excavated materials in soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Material and labour for Hard core of gauge of broken boulders exceeding 63mm but not exceeding 100mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rolled / rammed to a true surface complete all as specified and as directed.
Material and labour for PCC (1:4:8) type D-2, 75mm thick (using 40mm graded crushed stone aggregate) as sub base to floor complete all as specified and as directed.
Material and labour PCC (1:2:4) 75mm thick type B-1 (using 20mm graded crushed stone aggregate) as sub top layer complete all as specified and as directed.
Material and labour for vitrified tiles any colour 10mm thick (square / rectangular) polished as in floor, area of each tile not exceeding 0.36 Sqm etc set and jointed in neat cement slurry and pointed in colored cement to match pattern, laying etc of tiles and shade, colour shall be decided by Engineer-in-Charge complete all as specified and as directed.
Description all as per Ser item No 30.00 here-in-before but in vertical surfaces including 10mm thick cement rendering / backing coat of cement in cement mortar (1:4) complete all as specified and as directed.
Material and labour for 16 to 18 mm thick granite (of any type) work (tabled, rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite over and including 20mm thick screed bed of cement mortar (1:6) complete all as specified and as directed.
Material and labour for 75mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10mm wide grooves to full depth at 3m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of (1:3) by weight and top 10mm depth sealed with sealing compound grade 'A' complete all as specified and as directed.
Material and labour for 10mm thick cement plaster in cement mortar (1:3) over concrete surface finished even and smooth without using extra cement mixed with water proofing compound pidi proof LW @ 200ml per 50 Kg cement as per manufacturer's instructions complete all as specified and as directed by Engineer-in-Charge. Note: - Rates quoted are inclusive of water proofing compound.
Material and labour water proofing treatment provided with polymeric water proofing membrane 90 micron weighing not less than 3 Kg / Sqm on prepared surfaces vertical / horizontal laid over a coat of bitumen 85/25 @ 1.20 Kg / Sqm, over a coat of bitumen primer 0.50 Kg / Sqm one coat of bitumen 85/25 @ 1.20 Kg / Sqm shall be provided over water proofing membrane as per manufacturer's instructions complete all as specified and directed by Engineer-in-Charge.
Material and labour for applying two coats of alumnium paint on roof treatment complete all as specified and directed.
Supply only water proofing compound complete all as specified and as directed.
Material and labour for factory made single extruded WPC (Wood Polymer Composite) solid door / window / Ceosetory windows and other frames / chowkhats of size 45 X 70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 grams) fabricated with mitred joints after applying PVC solvent cement and screwed with full body threaded star headed stainless steel screws having minimum frame density of 750 Kg / cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm², modules of elasticity 900 N/mm² and resistance to spread of flame of Class 'A' category with property of being termite / borer proof, water / moisture proof and fire retardant and fixed in position with mild steel hold fast / lugs / stainless steel dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Notes: - For WPC solid door / window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Supply and fixing in repair 18mm thick factory made 100 % solid WPC flush shutter (for cupboard and vanity etc) made from co-extruded three layer rigid foam sheet (single extruded) with 0.8 to 1 mm thick outer layer having density not less than 1400 Kg / cum and density of central core not less than 600 Kg / cum manufacturer by an ISO 9001/2015 certified company complete all as specified and directed.
Material and labour for 30mm width of flaps (when open) continuous (Piano) hinges mild steel bright finish or electrogalvanised complete all as specified and as directed.
Supply and fixing 40mm dia cupboard knobs fixed with nut and washer brass polished bright finished complete all as specified and as directed.
Supply and fixing Aluminium powder coated aluminium door shutters with frame (frame sections not less than 3mm thick, shutter sections not less than 2mm thick). Bottom half panel filled with 8mm thick prelaminated particle board and top half portion covered with 5.5mm thick frosted glass including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 no's in each door, hinges, anodised aluminium snap beading, screws, two way floor door spring, mortise lock with keys etc complete all as specified and as directed.
Supply and fixing Aluminium powder coated four track sliding window shutters (two tracks for glazed shutters and two tracks for fly proof shutters) glazing with 5.5mm thick plain sheet glass and gauging with aluminium wire mesh of dia 0.45mm and aperture 1.40mm with sections of minimum 2mm thick including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and as directed.
Supply and fixing 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing with lamination, including teak wood liping 6mm thick on sides complete all as specified and as directed.
Material and labour for PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in back filling, bed block for hold fast, coping, benching on corner of joints etc complete all as specified and as directed.
Supply and fixing 150mm long aluminium anodised barrel tower bolts of extruded section ISI marked complete all as specified and as directed.
Supply and fixing pressed steel frames (factory made) made out of 1.25mm thick black mild steel sheet for doors with two rebates for fixing one shutter incluidng necessary fixing lugs, hinges, lock strike plate etc complete, size of frame 60 X 40mm including bottom of each chowkhat to be welded with 2 No's 25 X 25 X 3mm thick flat iron projecting 10cm on either side complete all as specified and as directed.
Supply and fixing 100 mm hasp and staple, safety type aluminium anoided including bolt to hinges plate and fixed with screws complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and directed
Material and labour for 100mm thick cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
Material and labour for 60mm thick machine pressed precast concrete interlocking paver block (M-35 grade) any shape. Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness and size / shape, made by table vibratory method using PU mould, laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand beddinglayer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
E/M Portion: - Material and labour for complete point wiring with 1.5 Sqmm single core multistranded copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 Sqmm copper conductor flexible FRLS insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall, plastering after concealing conduit, including modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and directed by Engineer-in-Charge.
Description all as per Ser Item No 52.00 here-in-before but for multi 5 pin 5 amp socket outlet on same board complete all as specified and directed.
Description all as per Ser Item No 52.00 here-in-before but for multi 3 pin socket outlet 5 amp socket on independent board complete all as specified and directed.
Description all as per Ser Item No 52.00 here-in-before but for multi 3 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistranded cable PVC insulated FRLS and unsheathed copper conductor multistranded cable 2.5 Sqmm as earth wire FRLS PVC insulated in green colour complete all as specified and directed by Engineer-in-Charge.
Supply and fixing modular switch 1 way 6 A, 1 module, 240 Volts ISI marked complete all as specified and directed.
Supply and fixing modular socket 6A - 5 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing modular switch 1 way 16A, 1 module, 240 Volts ISI marked complete all as specified and directed.
Supply and fixing modular socket 6A/16A - 6 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing ceiling rose, 3 phase / PVC / polycarbonate isolated body complete all as specified and directed.
Material and labour for fan regulator stepped electronic type suitable for AC, 240 V complete all as specified and directed.
Material and labour for lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Material and labour for self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and directed.
Supply and fixing LED lights fitting 1 X 20 W, 220 V AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor > 0.95, 100 Lumen / Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts 50 Hz complete all as specified and as directed.
Supply and fixing LED light fitting 1 X 9 W / 1 X 10 W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single phase 230V of size 300m sweep with blades and frame and louvers including taking down old one and deposited to MES store. Making holes for 300mm exhaust fan of suitable shape and size into or through brick walls including plastering for making good to the original surfaces of any description disturbed including painting / distemper matching with the existing colour including taking down old one and deposited to MES store complete all as specified and as directed. Note: - The rates includes for making good to the original surfaces of any description disturbed including painting / distemper matching with the existing colour.
Supply and fix Vertical distribution Board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing 12 No's MCB's and should be IP-43 protected with copper bus bars, neutral links, earthing bar complete all as specified and as directed including taking down old unserviceable distribution board / MCB any type. Notes: - (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 volts with adjustable thermal settings. (ii) Rate includes MCB SP 40 Amps 12 No's, 10 KA. (iii) TPB DB, MCB and MCCB should be of same make.
Material and labour for distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed
Supply and fixing 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated complete all as specified and as directed. Note: - Split A/C rate include in the cost of wiring and switches etc.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps SPN AC Box complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5 % and of capacity 5 KVA complete all as specified and as directed.
Supply and fix ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep minimu air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Material and labour for distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 2 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing LED street light fitting 35 Watt 230 V, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and fixing bracket for fixing of security light fittings bend to shape, made out of 40mm dia GI pipe medium grade upto 1.2 mtr long fixed with and including two sets of mild steel clamp made out of flat iron of size 50mm X 6mm, fabricated to shape and fixed with nuts, bolts and washers and two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed. Note: - Mild steel clamps including nuts, bolts and washers shall be measured and paid for separately under respective items.
Material and labour for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 1.5 Sqmm for phase and neutral and one run of 1.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concelaed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m deep in any type of soil, getting out and levelling of bottom surface to required level for poles / stay assembly / cable complete all as specified and as directed.
Description all as per Ser Item No 79.00 here-in-before but exceeding 1.5m deep but not exceeding 3.0 mtr deep complete all as specified and as directed.
Supply and laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 V grade cross sectional area 25 Sqmm, 4 core complete all as specified and as directed.
Material and labour sand filling in crushing bed of cable and consolidation complete all as specified and as directed.
Supply and laying common burnt clay building sub class 'B' bricks, laid over sand cushioning laid at right angle along with cable complete all as specified and as directed.
Supply and laying GI tubing light graded including all accessories for encasing cables for mechanical protection, laid under plinth / floors / path culverts with complete accessories such as bends / sockets / reducers / saddles including necessary threading / drilling works complete all as specified and as directed of sizes (Mild steel work will be measured under separate item in schedule) 40mm.
Material and labour for Earthing complete with galvanised mild steel earth plate electrode of size 600 X 600 X 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolts, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed.
Dismantling of ACSR conductors and taking down disturbed span including line spacer, cross arms, clamps, nut bolt from pole and removing old unserviceable cable etc, removal of accessories complete all as specified and as directed.
Supply and fixing in replacement of 1100 Volt Arial bunched conductor having phase conductor of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated, insulation screen of extruded semi conducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS 7098 Part-II of size 3 x 50 Sqmm + 1 x 50 Sqmm, 1 X 35 Sqmm and 1 X 16 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT disribution system complete all as specified and as directed.
Supply and fixing in replacement of 1100 Volt Arial bunched conductor having phase conductor of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated, insulation screen of extruded semi conducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS 7098 Part-II of size 3 x 70 Sqmm + 1 x 50 Sqmm, 1 X 35 Sqmm and 1 X 16 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT disribution system complete all as specified and as directed.
Supply and fixing in replacement of 1100 Volt Arial bunched conductor having phase conductor of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated, insulation screen of extruded semi conducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS 7098 Part-II of size 3 x 95 Sqmm + 1 x 70 Sqmm, 1 X 35 Sqmm and 1 X 16 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT disribution system complete all as specified and as directed.
Supply and fixing in replacement of 1100 Volt Arial bunched conductor having phase conductor of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated, insulation screen of extruded semi conducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS 7098 Part-II of size 3 x 150 Sqmm + 1 x 95 Sqmm, 1 X 35 Sqmm and 1 X 16 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT disribution system complete all as specified and as directed.
Supply and fixing in replacement of 1100 Volt Arial bunched conductor having phase conductor of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated, insulation screen of extruded semi conducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS 7098 Part-II of size 3 x 240 Sqmm + 1 x 185 Sqmm, 1 X 35 Sqmm and 1 X 16 Sqmm complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT disribution system complete all as specified and as directed.
Supply and fixing in replacement of cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 16 Sqmm to 35 Sqmm complete all as specified and as directed.
Supply and fixing in replacement of cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed.
Supply and fixing in replacement of cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and as directed.
Supply and fixing in replacement of cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 Sqmm to 300 Sqmm complete all as specified and as directed.
Supply and fixing in repair of insulation piercing connectors of suitable size for suitable size Aerial Bunched cable complete all as specified and directed.
Supply and fixing in repair of Anchoring Assembly of suitable size for suitable size Aerial Bunched cable complete all as specified and directed.
Supply and fixing in repair of Suspension assembly of suitable size for suitable size Aerial Bunched cable complete all as specified and directed.
Supply and fixing in repair of Service clamp of suitable size for suitable size Aerial Bunched cable complete all as specified and directed.
Supply and fixing in repair of transformer connections of suitable size for suitable size Aerial Bunched cable complete all as specified and directed.
Supply and fixing in repair of junction sleeve of suitable size for suitable size Aerial Bunched cable complete all as specified and directed.
Supply and fixing in repair of Aerial Bunched Cable service main distribution box 4 way 200 Amp of suitable size for suitable size Aerial Bunched cable complete all as specified and directed.
Supply and fixing in repair of stainless steel strap and buckles of suitable size for suitable size Aerial Bunched cable complete all as specified and directed.
Dismantling / taking up of LT unserviceable pre-stressed concrete / steel poles of any size and shape and including taking out dismantled portion of poles embeded in ground after necessary demolition of concrete foundation and making good disturbed ground surface properly and disposal thereof complete all as specified and as directed by Engineer-in-Charge. Note: - Earth work for taking out of poles shall be measured and paid separately under relevant item of this Schedule.
Material and labour for steel tubular swagged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screw as specified type 410 SP-31 (9.0 meters long) including two coats of silver paint over one coat of red oxide paint complete with strip of black and white strips having 30 cm of width upto 1.5 mtr height from top of coping including taking out old unserviceale PCC pole complete all as specified and as directed by Engineer-in-Charge. Note: - Excavation, foundation concrete, preservative treatment etc will be measured and paid separately.
Taking out old / unserviceable underground LT cables and connections including pipes, bricks or precast concrete cable cover etc from trenches / walls / poles of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site all as specified and directed.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 2 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm, 2 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Material and labour for road cutting, PCC hard standing as per site requirement including excavation for laying of GI pipe and making good the disturbed surfaces all as per existing surface complete all as specified and as directed.
Material and labour in replacement of GI pipe light grade 80 mm bore for cable protection as a guard pipe complete all as specified and as directed.
Material and labour in replacment of GI pipe light grade 50 mm bore for cable protection as a guard pipe complete all as specified and as directed.
Supply and laying well burnt old size sub class 'B' bricks laid flat with width equal to length of brick perpendicular to the direction of cable, adjacent / abutting each other in trenches over the cable for protection complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying in trenches clear sand for cushioning underground cable 8 cm below and 15 cm above complete in level all as specified and as directed.
Material and labour for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation of electric poles, struts, PCC blocks etc including necessary form work complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation of assembly, bed concrete including necessary form work and fair finish to exposed surfaces without using extra cement, struts, PCC blocks etc including necessary form work complete all as specified and as directed.
Material and labour for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles and similar work including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and as directed.
Supply, installation, testing and commissioning in replacement of feeder pillar board of size 60 cm X 45 cm X 30 cm Kiosk type, LT (415 Volts, 50 Hz, 3-phase, 4 wire supply) floor mounted, factory assembled, outdoor type weather and vermin proof (Protection Class IP-54) made out of angle iron base frame as required size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA, 40 x 40 x 6 mm thick angle iron duly painted - 3.15 mm thick mild steel sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement, powder coated externally and internally after seven tanks treatment and lifting channel, fully compartmentalized design complete Bus Bar chamber comprising 4 No's aluminium strip bus bars air insulated and PVC sheathed capacity 200 Amps 4 way with colour coding with incomer MCCB 4 pole current rating 100 Amp with adjustable thermal magnetic setting 70%-100% breaking capacity 25 KA at 415V, 50Hz - 01 No as outgoing complete all as specified and as directed.
Supply, installation, testing and commissioning in replacement of feeder pillar board of size 60 cm X 45 cm X 30 cm Kiosk type, LT (415 Volts, 50 Hz, 3-phase, 4 wire supply) floor mounted, factory assembled, outdoor type weather and vermin proof (Protection Class IP-54) made out of angle iron base frame as required size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 40 x 40 x 6 mm thick angle iron duly painted 3.15 mm thick mild steel sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement, powder coated externally and internally after seven tanks treatment and lifting channel, fully compartmentalized design complete Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 200 Amps 4 way with colour coding with incomer MCCB 4 pole current rating 125 Amp with adjustable thermal magnetic setting 70%-100% breaking capacity 25 KA at 415V, 50Hz - 01 No as outgoing complete all as specified and as directed.
Supply and fixing of ACSR conductor of any size and type from over head HT / LT poles including binding at site to insulator with suitable size of binding wire etc including taking down existing worn out old broken ACSR conductor of any size and type and length at any position from LT / HT poles complete all as specified and as directed.
Material and labour for galvanised steel wire 4.0 mm dia for continuous earth wire and cradles hexagonal / rectangular shall be provided and securely fastened to each pole and connected with earth ordinarily and cradle guarding where required complete including dismantling existing GI wire complete all as specified and directed.
Dismantling cross arms of mild steel channel or angle sections etc. and keeping serviceable materials in safe custody for reuse and / or unserviceable materials removing from the site (s) complete all as specified and directed.
Material and labour in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections i.e. mild steel channel or angle sections etc. including new nuts, bolts, washers as required dia / length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of red oxide, one under coat and one finishing coat of silver paint (1st quality ) as required complete as specified and as directed.
Fixing only serviceable cross arm, Mild steel channel, angle section obtained from Ser item No 130.00 here-in-before as ordered and inclusive of one coat of aluminium paint including preparation of old steel surfaces complete all as specified and directed.
Supply and fixing in replacement of unserviceable aluminium lugs / thimble of size 120 Sqmm complete all as specified and directed.
Supply and fixing in replacement of unserviceable aluminium lugs / thimble of size 70 / 95 Sqmm complete all as specified and directed.
Supply and fixing in replacement of unserviceable aluminium lugs / thimble of size 50 Sqmm complete all as specified and directed.
Supply and fixing in replacement of unserviceable aluminium lugs / thimble of size 35 Sqmm complete all as specified and directed.
Supply and fixing in replacement of unserviceable aluminium lugs / thimble of size 25 Sqmm complete all as specified and directed.
Dismantling LT stay assembly of any size and unserviceable materials removing from the site(s) complete all as specified and as directed. Notes: - (a) Unserviceable stay assembly shall be taken off / dismantled at ground level and making good disturbed ground surface. (b) Earthwork for demolition of cement concrete shall be included in quoted rate.
Material and labour for stay assembly with accessories and GI stay rod 16 mm dia 1900 mm long, stay wire 7/4 mm stranded galvanised including mild steel stay plate 300 mm x 300 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90 mm x 140 mm clearance of hole 25.5 mm complete all as specified and shown in electrical plate No 01 of SSR Part - I including taking down old unserviceable stay assembly all as directed. Note: - Excavation, stay clamps and concrete work etc will be measured and paid separately.
Dismantling insulators, any type, any size and keeping serviceable materials in safe custody for re-use and / or unserviceable materials removing from the site complete all as specified and as directed.
Material and labour in replacement of insulator pin type, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and as directed.
Material and labour in replacement of insulator pin type, polymer composit material including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and as directed.
Material and labour in replacement of insulator shackle type, porcelain, vitreous, white, brown or green, shall be in one piece and shall have a groove on the side and a hole for a cotter pin and two galvanised bolts 12 mm dia and nuts with or without a pair of straps in size 31 x 3 mm as indicated size height 75 mm and dia 90 mm, for working pressure 1100 volts complete as specified and as directed.
NOTE NO 1: - Samples of materials as approved will be kept in GE's sample room. NOTE NO 2: - All fittings and fixtures mentioned above will be fixed to the satisfaction of Engr-in-Charge and GE. NOTE NO 3: - Warranty certificate to the Engineer-in-Charge where ever applicable shall be submitted by the Contractor at the time of fittings.
Sarbat Construction Co
M/s Sahib Construction and engineers
BMMJ TRADERS AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .