Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC 197 4 KANTADANGA ROAD FINGAPARA N24PGS PIN 743129 | FINGAPARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹33.8 L+₹67,556.70 (2.04%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹37.2 L+₹4.1 L (12.2%)Rejected-Finance KASHIJORA P O BENAPUR DIST PASCHIM MEDINIPUR | BENAPUR | PASCHIM MEDINIPUR | WEST BENGAL | L3 | Rejected-Finance NOT BEING L1 |
Tender Value
₹25 L
EMD Value
₹25,000
Closing Date
8 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR M K YDADAV
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
REPAIR AND MAINTENANCE OF BOREWELL, PUMP SETS, PUMP HOUSES, PANEL BOARDS, FILTER PLANT AND CONNECTED WORKS AND DAY TO DAY MAINT OF EM WORKS IN DOMESTIC AREA AT AF STN SALUA UNDER GE (AF) KALAIKUNDA
2023_MES_631070_1
C/8921/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN SALUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹25,000
Yes
8 Mar 2024
5 Dec 2023
9 Jan 2024
5 Dec 2023
8 Jan 2024
19 Dec 2023
Amount
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) specification for a period of six months for 1 HP capacity 3- phase, 415 volts, 50 Hz Openwell submersible /Monoblock pump sets installed at various locations through approved Agencies as approved by GE,and including rewinding of burnt Openwell submersible /Monoblock motor 1 HP , 3 phase, 415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface complete all as specified and directed. [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]Note spare part required to replaced repair upto Rs 2000 deemed to be inluded in quoated rates Note :- (i)Commencement date of comprehensive period to be considered from the day on which the pump will be under take first time for maintenance. (ii) The unit quoted rate is for total comprehensive period of six months. However, incase completion certificate issued prior to completion of comprehensive period, payment will be made on prorata basis. Contractor may also claim running payment on pro-rata (monthly) basis.The quoted rate is deemed to be included all the factors.
All as per the item no 01.00 but 0.5/1 Hp dosing pump/motor complete all as specified and directed. [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]Note spare part required to replaced repair upto Rs 2000 deemed to be inluded in quoated rate
S& F in replacement dosing pump roller assembly suitable for existing dosing pump complete all as specified and directed by EIC . Make of roller assembly :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new roller assembly as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of Roller assembly for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
S& F in replacement dosing pump tube suitable for existing dosing pump complete all as specified and directed by EIC . Make of Pump Tube :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new pump tube as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of Pump tube for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
S& F in replacement dosing pump weighted suction line strainer suitable for existing dosing pump complete all as specified and directed by EIC . Make of Injection check valve :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new weighted suction line strainer as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of weighted suction line strainer for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
S& F in replacement dosing pump Injection check valve suitable for existing dosing pump complete all as specified and directed by EIC . Make of Injection check valve :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new Injection check valve as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of Injection check valve for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
(a) Lifting of defective submersible pump set of any make and capacity 20/25 HP from after providing lifting tools , chain pulley etc. as required carefully, by disconnecting/dismantling all electric connections, column pipes, steel ropes/chain and keeping them under safe custody for reuse and Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) specification, installed at various locations through approved Agencies as approved by GE with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc.and applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of pump external surface complete all as specified and directed. all complete and (b) Lowering of repaired /overhauled/rewinded submersible pumping set of any make and capacity after proper coupling of pump and motor , fixing old/new chain with clamp, connecting/refixing existing/new column pipe lines with new rubber gasket 3 mm thick, nuts, bolts & washers carefully with the help of chain pulley etc. & carefully re-connecting all electric/water lines and testing on load to the entire satisfaction of Engineer-in-charge complete.
NOTE : (i) The cost of transportation of the defective submersible pumping set (pump or motor) from site to OEM workshop & back is deemed to be included in the quoted rates. (ii) Column pipe/ submersible cable/supporting chain required new will be measured and paid separately as supply only. (iii) Repair of motor and pump measured separately (iv) refixing of column pipe to be done after proper descaling . (v) Each maintenance job shall be valid till expiry of defect liability period. (vi) All minor spares required for making the pump functional shall be provided by contractor without any extra cost. No payment shall be made on account of any breakdown service to the machinary/equipments during comprehensive maintenence period. (viii) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.500.00 (Rupees Five Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contract. (ix) Cost of minor items like insulating tape,gland packing materials, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoated rate.
All as per item No.08.00 here-in-before but capacity 7.5 HP open hole submersible pump.
M & L for rewinding of burnt submersible pump set of any make and capacity up to 10 HP, 3 phase ,415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface and water proof jointing for submersible cable 3 core, with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc. complete as specified and directed.
All as per item No.10.00 here-in-before but capacity 7.5 HP open hole submersible pump/ Non clogging sewage pump
Supply only Bowl CI submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix in replacement of sleeves (S/S) submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix of rubber bush submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix stud nut of submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix neck ring of submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Supply & fix thrust bearing of submersible motor of capacity of 5 to 25HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
M & L for disconnection of electrical connections de-couplings from centrifugal pump, unscrewing foundation nuts, bolts & washers of squirrel cage induction motor from foundation base plate and taking out carefully for comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) specification for a period of six months of 15 HP (3 phase, 415V, 50C/S, AC Supply) of any make overhauling, servicing, cleaning thoroughly cases, impellers ,shaft, bearing housing, gland packing, descaling all derts and assembling after repair with required machining works ( if any), new key, new both end bearings, old bearing cover, new gland packing with old gland cover, old/new impeller, stuffing box stud, rubber coupling including applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of pump external surface, inluding rewinding of burnt centrifugal pump 15 HP of any make through authorised services centre of OEM with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete , and refixing after repair, jointing coupling with pump, electrically connected, setting proper alignment with pump with old/new nuts, bolts & washers, rubber coupling joint and testing complete (iii) Repair of motor and pump measured separately however if any repair which is not catered in BOQ and it is necessary to making the pump functional shall be provided by contractor without any extra cost. (iv)Commencement date of comprehensive period to be considered from the day on which the pump will be under take first time for maintenance.(v) The unit quoted rate is for total comprehensive period of six months. However, incase completion certificate issued prior to completion of comprehensive period, payment will be made on prorata basis. Contractor may also claim running payment on pro-rata (monthly) basis.The quoted rate is deemed to be included all the factors..(vi) All minor spares required for making the pump functional shall be provided by contractor without any extra cost.(vii) Breakdown Maintenance : The approved Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE kalaikunda officials or their representatives.The approved agencies will carry out the required repairs of the units and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service to the machinary/equipments during comprehensive maintenence period. (viii) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.200.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contract (vi) Cost of minor items like insulating tape,gland packing materials, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoated rate.
Supply & fix Rotor shaft with couplings and seals of above pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
S&F in replacement of marking tape as per OEM specification complete all as specified and directed.
S&F in replacement of ' O ' Ring and gasket centrifugal pump/open hole pump/Non clogging sewage pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
S&F in replacement of Radial bearing upper centrifugal pump/open hole pump/Non clogging sewage pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
S&F in replacement of radial bearing lower centrifugal pump/open hole pump/Non clogging sewage pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
S&F in replacement of pump bearing centrifugal pump/open hole pump/Non clogging sewage pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
S&F in replacement of Shaft key centrifugal pump/open hole pump/Non clogging sewage pump of capacity 5 to 15 HP as per Original Equipment Manufacturer's (OEMs) specification through approved Agencies as approved by GE [Make: Calama/Kriloskar/CRI/KSB/Crompton Greaves/]
Re - development of existing / old bore well by air compressor or other machine (Minimum air compressor used 8- 10 hrs per bore ) with air line pipe after Lifting of submersible pumping set of any make and capacity from bore well after providing lifting tools, chain pulley etc. as required carefully, by disconnecting /dismantling all electric connections, column pipes, steel ropes/chain and keeping them under safe custody for reuse all complete and (b) Lowering of submersible pumping set of any make and capacity inside bore wells after proper coupling of pump and motor , fixing old/new chain with clamp, connecting/refixing existing/new column pipe lines with new rubber gasket 3 mm thick, nuts, bolts & washers carefully with the help of chain pulley etc. & carefully re-connecting all electric/water lines and testing on load to the entire satisfaction of Engineer-in-charge Note : 1. Any tools & plants required to complete the job shall be include the rate of quoted . 2.refixing of column pipe to be done after proper descaling . 3. All minor spares required for making the pump functional shall be provided by contractor without any extra cost.
M & L for cleaning and washing of inside portion of RCC OH reservoirs/Water tank of Capacity of Round/ Square type of Capacity 100000 gallons (including 02 chambers) up to 25 mtr height ,located in domestic area, with Anti-bacterial agent consisting of following process: - Dewatering the tank by mechanical means as directed, de-silting and removing of left over dirty water up to 100 to 150 mm in the bottom of the tank and sludge with special sludge pump, cleaning of walls and ceiling with special mechanized high pressure jet machines by rotary jet system at 100-120 Bar pressure (120 Kg /sq cm) which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains and cleaning chemicals if required of make Eureka Forbes Ltd or equivalent as approved by GE, floor of the dirty tank should be thoroughly cleaned up by fry jet cleaner to accumulate all dirt ,the remaining sludge should than be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial Vacuum Cleaners to make the floor totally dirt free, application/spraying of Anti-Bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the above operations should be executed by trained workers and technicians, properly dressed along with gum boots, to work as per the direction of Engineer in charge. and writing "Date of cleaning and Next due date of cleaning" on the column of tank at specified location with and including necessarry scalfolding and safety measure complete all as specified and directed.
All as per item No.27.00 here-in-before but capacity of 50000 gallons, complete all as specified and as directed
All as per item No.27.00 here-in-before but capacity of 22000 gallons, at Aerator deck to flux mixer complete all as specified and as directed .
All as per item No.27.00 here-in-before but at Sedimentation tank (28000 Gallons /h) complete all as specified and as directed .
All as per item No.27.00 here-in-before but at Filter bed (28000 Gallons ) complete all as specified and as directed .Note for item No.27.00 to 31.00 : (i) Removing of bee heavs and cleaning of vegitation grown on tank shall be done by the contractor without any extra charge. (ii) All T&P required at site for cleaning of tank shall be arranged by the contractor without any extra cost.. (iii) All safety measures, safety belts, helments and other safety tools required at site for the trademens deployed for cleaning of tanks (under ground and over head RCC tanks) shall be provided by the contractor without any extra cost. (iv) Contractor has to clean the tank after tanking permission from Eng in Charge in one week advance. (v) Contractor shall use dewatering pump and industrial vaccume cleaner for cleaning of tank. (vi) Contractor shall deploy sufficient labour for cleaning the tank with stipulate time period of same day so that water supply from that tank would not be hampered. (vii) Contractor has to submit the photos of inside tank before cleaning and after cleaning to the Eng in Charge before claiming for payment. (viiii) Contractor shall provide ACP sheet of size 400 mm x 400 mm on each tank for writing date of cleaning of tank and next due date of cleaning on blue base with white colour. (IX) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the above mentioned works.
Supply only Ferric Alum Gde I for purification of water containing lead ( as Pb) 30 ppm maximum confirming to IS 299/ 1989 complete all as specified and as directed.
Supply only calcium hypochlorite granule 65 % to 70 % chlorine grade I in air tight sealed plastic bags for treatment of drinking water complete all as specified and as directed. Note :- 1. Approval of chemical ( calcium hypochlorite) shall be given after verification of test certificates and their chemical analysis , strength in terms of quantity of chlorine content. 2. The brand/make of chlorination chemical must be certified by Govt. Laboratory and confirming compliance of specification , suitable for drinking water.
Supply only Chlorine test kit/ iron test kit against old u/s kit with coloured sample complete with all testing fitments and OT solution in rexine finish box complete all as specified and as directed.
Testing of drinking water sample for servicable borewell No 3,6,7 and after treated water of filter plant of this station with under mention test by authorised lab ie, IIT Kharagpur or District water testing laborotory kharagpur as approved by GE and Test report shall be submitted to GE along with RAR/FB, India :- CHEMICAL TEST :- (a) PH Valve,Temperature,Turbidity,Total hardess (as caco3) mg/l, Alkalinity, TDs ppt. Max,Iron mg/l ,Nitrate mg/l,Chloride mg/l,Residual chlorire mg/l, Fluoride mg/l. BACTERIALOGICAL:- (b) Coliform orgnisms, Faecal coliforms.
Comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) specification for a period of six months of existing of engine oil of Air compressor ( air blower ) fitted with 5 HP 440 V AC 1440 rpm TEFC motor cap: 200 cfm complete all as specified and directed. Note :- (i)Commencement date of comprehensive period to be considered from the day on which the pump will be under take first time for maintenance. (ii) The unit quoted rate is for total comprehensive period of six months. However, incase completion certificate issued prior to completion of comprehensive period, payment will be made on prorata basis. Contractor may also claim running payment on pro-rata (monthly) basis.The quoted rate is deemed to be included all the factors.
Supply & Fix fully automatic star delta Submersible pump starter in sheet steel enclouser suitable for 25 HP pump set , 3 phase , 415 volt , 50 Hz , including making all electrical connection to run the pump and taking out old unserviceable complete all as specified and directed by Engr-In-Charge.
Supply & Fix DOL pump starter in sheet steel enclouser suitable for 7.5 HP pump set , 3 phase , 415 volt , 50 Hz including making all electrical connection to run the pump and taking out old unserviceable starter complete all as specified and directed by Engr-In-Charge.
S& F in replacement of brass vertical check valve of size 80 mm for 5 HP/7.5 HP pump complete all as specified and directed
Supply only rubber gasket of size not less than 5 mm thick as per sample for repacking valves/leakage gasket packings.
Materials and Labour for valve pit cover using brick masonry with fly ash brick valve chamber of internal size 1.5 M x1.5M x1.0 M with 23 cm thick wall in CM 1:6 including excavation if required, earth work in any strata & PCC 1:4:8 foundation type D-2, 75 mm thick including 20 mm thick PCC 1:2:4 type B1 in & plastering the internal surface with 10 mm thick cement mortar 1:4 if required & replacing old 3.15 mm MS sheet chamber cover double opening arrangement center lock system with 40x40x6mm angle iron frame duly painted with two coat of black bituminous paint over one coat of red oxide primer with and inluding demolition of existing complete all as directed by Engr in Chargre.
S&F in replacement of 8 mm dia steel wire rope for hanging submersible/sewage pump of various overhead tanks installed in AF station salua all as specified and directed by Engr-in charge.
Cleaning the vegetation incl grass, bushes, small trees & all vegetation growth complete incl digging out roots of bushes around installation /sump/OH tanks/ valve chamber incl leveling the surface by removing debris to a distance n.exc 50 mtr all as directed.
Materials and Labour for,run lead joint for cast iron spigot and socket pipes and fittings for water mains ,200 mm bore, including burning out lead joints in position and including removing old lead from site, complete all as specified and directed. ( NOTE:- Earthwork shall be included in quoated rates)
All as per item No.44.00 above but 150 mm dia.complete all as specified and as directed.
All as per item No 44.00 above but 100 mm dia.complete all as specified and as directed.
Materials and Labour for,run lead joint for cast iron spigot and socket pipes and fittings for water mains ,80 mm bore, including burning out lead joints in position and including removing old lead from site, complete all as specified and directed. (NOTE:- Earthwork shall be included in quoated rates)
Supply and fixing in repair Non return (Reflux valve) 150 mm dia , flap type ISI marked,as per IS 13095: 1991,both end flanged including fiber board gasket, bolts, nuts and washers for fixing the valve in position, or location as directed and specified by Engr-in-charge . Make : Uphadhya / Kirloskar/ Leader
M&L for disconnecting existing tank setting aside for repairs, including cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.300 and not exc. 500 ltrs complete all as specified & as directed. Note : Spare part required to be replaced up to Rs 200 deemed to be included in quoated rates.
M&L for disconnecting existing tank setting aside for repairs, including cleaning of service PVC tank by rubbing vertical wall and bottom of with bleaching powder and allowed ½ hour to react and then washing down with water to get free from deposits and bleaching inside the tank of capacity and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.500 and not exc. 1000 ltrs complete all as specified & as directed.Note : Spare part required to be replaced up to Rs 200 deemed to be included in quoated rates.
M & L for 5 layers of gravel (50mm to 40mm size-75mm), 40mm to 20mm size-75mm, 20mm to 15mm size 75mm, 15mm to 5mm size 75mm and 5mm to3mm size-150mm followed by two layer of quartz sand dumbed and leveled near filter plant area of effective size 0.55mm to 0.7mm of uniformity coefficient not exceeding 1.5,and free from clay, sand, loam and organic impurities of any kind,conforming to IS 8419, Part-I, inside rapid gravity filter with and including removing old complete all as specified and directed.
S&F in replacement of HDPE pipe of 90 mm size from the filter bed including fittings complete all as specified and directed
S& Fof brass spindal for sluice valve of 200 mm ISI marked, brass check nut, with fiber board gasket, bolts, nuts and washers for fixing the valve in position, in valve pit chambers or location as directed
S&F of brass spindal for sluice valve of 150 mm ISI marked, brass check nut, with fiber board gasket, bolts, nuts and washers for fixing the valve in position, in valve pit chambers or location as directed
Material & labour for disconnecting existing Rapid Sand Filter of 22000 GPH from inlet & outlet pipe and removing complete layers, PVC strainer and painting with two coat each of Black Bituminous paint(inside of the filter suitable for drinking ), Red Oxide primer (Outside of the Filter) with and two coat of synthetic Enamel paint(Outside of the Filter) after through inspection from existing system with suitable tools including cleaning of the filter by dewatering, removing sludge, mud and dissolved iron water and scrubbing the algae from inside walls, corners etc complete by using brush and bleaching solution all as specified and as direted. Note : Any damage to existing system or structure shall be made good by Contractor without any extra cost.
Supply and Fix in repairs, PVC double nut type strainer suitable for rapid sand filter, complete all as specified and directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
M& L for painting with two coat of Black Bituminous paint(inside of the filter suitable for drinking after through inspection from existing system with suitable tools including cleaning of the filter by dewatering, removing sludge, mud and dissolved iron water and scrubbing the algae from inside walls, corners etc inside water tank/sedimentation tank after cleaning complete by using brush and bleaching solution all as specified and as direted. complete all as specified and directed by Eng in charge.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer after complete removal of existing treatment and preparation of surfaces on pipe lines any type/size on surface / floors with in the pump house / installation premises for sizes upto & including any bore and outer surface of over head tank complete all as specified and directed. (Note: Painting includes painting on fittings without considering any additional factors. Area of fittings shall be calculated as per nominal size of pipe and length.)
M& L U clamp heavy duty for steel wire rope clamping all as specified by EIC.
M&L for framed work for valve pit chamber cover made of Mild steel (MS) equal angle and MS sheet 2.8 mm thick including welding , cutting ,hinges , locking arrangments , painting including dismantling wrought iron or mild steel work of any description provided for valve pit chamber and for angle iron ladder of tank complete with and including two coat synthethic enamel paint high glossy finish, of Make Asian Apcolite rust shield , Anti rust shield PU enamel over a coat of primer complete all as specified and directed
Supply and Fix in repairs,ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe 20 mm bore and fixed (Minimum weight 210 grams), complete all as specified and directed.
Supply and Fix in repairs,ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe 25 mm bore and fixed (Minimum weight 455 grams), complete all as specified and directed.
S&F in repair switch piano flush type single pole,5 Amp. AC, 230 V one way complete all as specified and directed by EIC.
S&F switch piano flush type single pole one way 5 Amps complete all as specified and directed (Note : Item to be measured if executed under new point wiring)
S&F in repair Polycarbonate Switch socket combination 5 Amps ,2 in 1, flush type complete all as specified and directed by EIC.
S&F Polycarbonate Switch socket combination 5 Amps ,2 in 1, flush type complete all as specified and directed by EIC.(Note : Item to be measured if execuated under new point wiring)
S&F in repair Switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose complete all as specified and directed.
S&F Switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose .complete all as specified and directed by EIC(Note : Item to be measured if executed under new point wiring)
S&F in repair ceiling Rose, surface,bakelite 65mm polycarbonate three terminals, AC, 230 Volts complete all as specified and directed by EIC.
S&F ceiling Rose, surface,bakelite 65mm polycarbonate three terminals, AC, 230 Volts complete all as specified and directed by EIC.(Note : Item to be measured if execuated under new point wiring)
S&F in repair bell push flush type single pole one way, 5 Amp, AC,230 V complete all as specified and directed by EIC.
S&F bell push flush type single pole one way, 5 Amp, AC,230V complete all as specified and directed by EIC.(Note : Item to be measured if execuated under new point wiring)
S&F Bell ,Ding dong type electric AC, 230V, Single phase,complete all as directed by EIC.(Note : Item to be measured if execuated under new point wiring)
S&F bell ding dong type,AC, 230 volts, single pole on PVC box complete all as specified and directed by EIC. (Note : Item to be measured if executed under new point wiring)
S&F in repairs LED Bulb 12 watt with B22 base built in Rechargeable battery,cool day white, 1100 lumen 6500 K, surge protection upto 4 KV ,4 hrs battery backup ,AC 230V complete all as specified and directed
S&F in repairs LED smart Bulb 9 watt with B22 base and wi-fi connectivity, colour changing , 806 lumen 6500 K,AC 230V ,complete all as specified and directed by EIC. icomplete all as specified and directed .
M&L in repair lamp holder , PVC/Poly carbonate type with back plate suitable for LED lamp fittings .including complete all as specified and directed
Taking down old unserviceable TPN / SPN MCB DB's incl MCB of any size and any discription complete all as specified and directed .
S & F sheet metal enclosure for MCB, DB, VTPN 415 Volts,IP-43, 100 amps rated copper busbar 4 way Double door ( Vertical DB with prov of MCB as incomer) Confirming to IS as per IEC 61439-3 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge.
S&F sheet metal enclosure for VT DB TPN, MCB DB TPN 4 way (with provision for MCCB as INCOMER and MCB as out going), Confirming to IS as per IEC 61439-3, IP 43,double door including 63 Amp, 25 kA,TP MCCB as incomer (Vertical type double door, 63 Amps MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3,12 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed .
S & F in repair sheet metal enclosure for MCB, DB, SPN, 240 Volts, 2 way, single door without bus bar, enclosure made up of CRCA sheet steel RAL 9003 powder coated, IP 30 complete all as specified and directed by EIC.
S & F circuit breakers (MCB), three pole with one protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated Rated current 40 to 100 A,, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. Note: DB and MCCB/MCB shall be of same make.
S & F circuit breakers (MCB), three pole (TP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 25A to 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. Note: DB and MCCB/MCB shall be of same make.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.. Note: DB and MCCB/MCB shall be of same make.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated Rated current 6A to 32 A,, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. Note: DB and MCCB/MCB shall be of same make.
S&F in repair of stepped type electronic fan regulator 100 watt flush type (mini) on the existing hylem laminated sheet etc as required complete all as specified and directed by EIC.
S&F stepped type electronic fan regulator 100 watt flush type (mini) on the existing hylem laminated sheet etc as required including taking down old u/s complete all as specified and directed by EIC.(Note : Item to be measured if executed under new point wiring)
S & F in repair LED bulkhead light with pressure die-cast housing light fittings nominal power 10/12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1100, lumen , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete all as specified and as directed.
S & F in repair LED wall mounted light Decorative type batten IP 20 with opal glass diffuser,B22 base type ,including 9 w LED bulb .complete all as specified and directed by EIC.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor FRLSH cable as per IS 694: 2010 (with colour code), drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed.
M&L for concealed Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including PVC conduit pipe not less than 25 mm ISI marked including all accessories of conduit pipe as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continous earth conductor cable connected to earth dolly complete all as specified and directed by EIC.Note : Submain Wiring to be done as per approved colour code in IE rule.Rate includes chase cutting for concealed submain wiring.
S&F for Sub main wiring with Four run of single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 10.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in with and including PVC casing capping not less than 32 mm ISI marked including all accessories of casing caping including one run of PVC insulated unsheathed 10.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed by EIC. ( 4 x 10.0 sqmm + 1 x 10.0 Sqmm earth wire).
S&F for Sub main wiring with Four run of single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in with and including PVC casing capping not less than 32 mm ISI marked including all accessories of casing caping including one run of PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed by EIC. ( 4 x 6.0 sqmm + 1 x 6.0 Sqmm earth wire).
S&F in repair PVC casing caping of min 25 mm dia exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping including taking down old u/s all as specified and directed by Engineer in charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants,regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.complete all as specified and directed by EIC.
S&F point wiring with 1.5 Sqmm FRLSH multi stranded copper conductor 1100 V grade,as per IS 694: 2010 , ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable duly painted with aluminium paint inside and anticorrosive paint out side with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets for the following:- Note : (i) Contractor has to make the surface good after flushing the sunken box as per existing specification without any extra cost
One light/fan point controlled by one switch.
One 3 pin socket outlet, 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps on independent board.
All as per item 101.00 here in before but wiring with 2.5 Sq mm FRLSH mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLSH insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed by EIC.
All as per item 101.00 here in before but power point wiring with 4.0 Sqmm FRLSH multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable & including PVC casing caping of 25 mm wide , including all accessories casing caping complete with PVC 4.0 sqmm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, for industrial metal clad socket power point.complete all as specified and directed by EIC.
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, including taking down old u/s complete all as specified and directed by EIC.
S&F in repairs laminated bakelite sheet cover, ISI marked with CM/L no.cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in loc with new galvanised screw and cup washer complete all as specified and directed by EIC,including taking down old u/s of following sizes.
11 x 13 inches
9 x 11 inches
5 x 8 inches
5 x 5 inches
6 x 6 inches
Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed .
S&F in repair modular switch 1 way 6A, 1 Module complete all as specified and directed
S&F in repair modular switch 1 way 16A, 1 Module complete all as specified and directed
S&F in repair modular bell switch 1 way , 1 Module complete all as specified and directed
S&F in repair modular socket 6A/16A 2/3 Pin combined -2 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings complete all as specified and directed by EIC
S&F in repair modular switch socket combination 16A , 6 Pin combined -3 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings complete all as specified and directed by EIC
Supply and fixing in repair of stepped type Modular electronic fan regulator 2- module , 100 watt flush type , on the existing hylam laminated sheet etc as required.complete all as specified and directed by EIC .
Supply and fixing in repair of stepped type Modular electronic fan regulator 1- module , 100 watt flush type , on the existing hylam laminated sheet etc as required.complete all as specified and directed by EIC .
S&F in repair Modular metal flush box of 1/2 module including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular metal flush box of 3 module including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular metal flush box of 4 module including taking out u/s including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular metal flush box of 6 module including taking out u/s including make good to match with existing surface complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 2 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 3 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 4 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 6 Module complete all as specified and directed by EIC.
S&F in repair Modular white cover plate with frame for 8 Module complete all as specified and directed by EIC.
S&F in repairs wall mounted bed side study lamp aluminium body, 3 W LED type warm white including LED driver with on /off button switch ,flexible pipe with lamp head 360 degree rotating type, 220 Volts, including taking down old u/s. complete all as specified and directed by Engr- in- charge.
S&F for repairing distribution box(DB's) of any rating, any size by proper dressing of wirings,providing lugs, screw, nuts , cleaning of the burned surfaces etc, tightening of all the connections of incoming and outgoings from the MCB's/ DB, connecting Earthing connection to each earth dolly including fixing of DB cover by providing screws etc complete all as specified and directed by EIC.
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 10-60 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with (parameters to show Date, time, current reading, KW, PF) including taking out old u/s complete all as specified and directed by EIC Make : Secure (Model Saral) or eqivelent of make: L&T Note : Old u/s meter to be deposite in AGE E/M store.
S&F in repair three phase, 4 wire direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V( P-N) and 400/415V (P-P), 10-60Amp, sprint 350, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with polycarbonate cover( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electrical connections, connecting PVC cable by providing suitable size copper lugs etc, complete all as directed specifed and directed by EIC. Make : Secure(Sprint 350) /L&T/HPL/Siemens. Note : Old unservieable meter to be deposite in MES store.
M & L for bracket made out of GI pipe 40 mm dia medium grade, 1.6 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick 2-nos mild steel nuts, bolts incuding painting two coats of aluminium paint over a coat of primer all as specified and directed by Engineer In Charge.
S&F PVC flexible roll white colour ,size 20 mm with and including all accessories ISI MARKED including taking out old unserviceable complete all as specified and directed MAKE: Presto Plast or equivalent of make :Supreme/Prince/Finolex
S& F in repair Rigid non-metallic PVC conduit pipe dia 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock,nuts, saddles, pipe hooks etc complete all as specified and directed by EIC.
Note :- (i) For item to be replaced under repair (day to day complaint) contactors trade man should report to E/M complaint cell daily and take complaint from concren JE E/M and after attending complaint he should give feedback and return the complaint slip to concern JE E/M in the evening at 17.30 Hrs on same day. (ii) Tradesman deployed for work should wear proper uniform with full shirt and full Pant. Colour code will be decided by EIC. (iii) For any minor repair required in wiring or their is any fault in circuit where the item under repair is to be replaced, contractor has to identify and recitified the fault without any extra cost. (iv) Contractor must ensure a stock of 25% of total qty as catered in CA or 25% of balance qty of the item as catered in CA (during currency of contract) at the MES provided store. If the contractor not provided said above recovery shall be made as per Terms and Condition of the contract as specified in particular specification. However no ‘Advance on Account’ against this provision as material laying at site shall be admissible.
(v) All LED lights/ flood lights shall be properly connected with earth dolly provided with fittings and earth connection. (vi) All LED lights have replacement warranty of 3 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of 3 year replacement warranty certificate (vii) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and defects covered in standard warranty policy. (viii) The contractor shall submit the surge protection certificate and type test certificate LM 79, LM 80 for luminaries. (ix) All LED fitting shall be identified by printing or fixing sticker duly mentioned the CA number and date of completion. (x) For any change in product or change in catalogue No. etc due to technological up gradation, letter has to be obtained from the lighting company on their letter head signed by an official of National level. (xi) All T&P required at site for installation of light on Bldg/ hanger or at any location shall be arranged by contractor.
Rate quoated above all items here in before inclusive provision as under :Making arrangement for establishment of centralized complaint centre in the existing building as under :- (a) Infrastructure required in Complaint cell i.e. Computer, printer, telephone, furniture, stationary, transport and other necessary items/materials to establish a complaint centre able to receive and manage complaints from the users by all means ie Manual complaint mechanism, Telephonic complaints mechanism, SMS complaint Mechanism and e-mail complaint mechanism, online complaint mechanism and to maintain a consolidated list of complaints and its redressal mode indicating all its relevant data as directed by Engineer-in-Charge.
(b) Provision and maintenance of all tools, plants, equipment and safety gear required for tradesmen under this contract (c) Provision of communication facilities to supervisor and tradesmen. (d) Monitoring and management of complaints report from generation to execution of complaint including pending complaints. (e) Updating status of lodged complaints before change of eight hour shift. (f) Provision of motorized conveyance for deployment to all tradesmen under this contract. (g) Basic inputs to be noted from the complainants will be locality, Building No, Qtr No, Name and Rank of complaint and exact nature of complaint and mobile No/ telephone or based on inputs provided in the complaint redressal sofware. (h) MES may provide software for generation of complaints. However operation entry, printout and releated activities wrt complaint registry and redressal will be the resposibiity of the contractor. On lodging the complaint, the Complaint No will be assigned for reference . Accordingly a corresponding complaint slip shall be generated by the system with all relevant info. Complaint slip should be printed in triplicate and to be handed over immediately to Supervisor who shall detail appropriate tradesmen for repair with required materials/store. One copy of complaint shall be retained in complaint centre and two copies with tradesmen.
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in sub base /hardstanding /floor/path, pavings, etc. all as specified and as directed.
M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate 75 mm thick in sub base /hardstanding /floor/path, pavings/plinth protechion , etc. all as specified and as directed.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 25 cm X 25 cm X 22 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
Materials and Labour for brick work with fly ash brick straight or curved on plan exceeding 6M mean radius built in cement mortar (1:6), complete all as specified and directed.
Materials and Labour for brick work with fly ash brick straight or curved on plan exceeding 6M mean radius built in cement mortar (1:4), complete all as specified and directed.
Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles throating,and roof padding as directed including necessary from work complete all as specified and directed.
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - (Water proofing compound will be deemed to be included in unit rate quoated by bidders)
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
All as per item ser No 154.00 herein before above but add or deduct for each 25mm girth or part there of over or under 30 cm all as specified & as directed.
M&L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in surface channels and drains complete all as specified & as directed.
Demolition of reinforced cement concrete of any description and in any position (Reinforement cut as required to facilitate demolition) and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M&L Mild Steel TMT bars 6 mm to 8 mm dia and over cut to length, bent to shape required , including cranking, bending spirally for hooping for columns,hooking ends and and bending with and including mild steel wire(anneled) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed
M&L for Formwork to soffits of suspended flat slabs of rough finished surface such as culvert slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all specified and directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, fixed to walls incuding mild steel clamp not more than 1metre C/C complete all as specified and directed by Engineer- in- charge .
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil ,complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of internal dia 600 mm, set in cement mortar complete all as specified and as directed.
M&L 600mm bore,HDPE double wall corrugated(DWC) SN-8 PIPE (HDPE Black Pipe) WITH COUPLER Conforming to IS:16098 Part-II:2013 sewage pipes laid in trenches and jointed as per manufacturer,s instruction with and including all fitting complete all as specified and as directed.
Returning filling in any type of soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all asspecified and directed.
M&L for preparation of old painted surfaces of Steel surface of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel painting complete all as specified and as directed.
SUMAN CONSTRUCTION
M/S Tapan Sur
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .