| 1 | L1₹42.6 LAccepted-AOC A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹44.6 L+₹1.2 L (2.66%)Rejected-Finance VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L2 | Rejected-Finance Other than
lowest
bidder | |
| 3 | L3₹49.3 L+₹5.8 L (13.3%)Rejected-Finance 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | L3 | Rejected-Finance Other than
lowest
bidder | |
| 4 | L4₹49.3 L+₹5.8 L (13.4%)Rejected-Finance | L4 | Rejected-Finance Other than
lowest
bidder | |
| 5 | L5₹52.8 L+₹9.4 L (21.5%)Rejected-Finance NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | L5 | Rejected-Finance Other than
lowest
bidder |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
24 May 2023, 6:00 pmClosed
GE BABINA
GE BABINA CANTT 284401
REPAIR/ RENEWAL OF STREET LIGHT/ FLOOD LIGHT/ HIGHMAST LIGHT FITTINGS INCL ALLIED WORKS AT OLD CANTT BABINA AREA UNDER GE BABINA
2023_MES_590093_1
8127/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹92,000
Yes
14 Jun 2023
18 Apr 2023
26 May 2023
18 Apr 2023
24 May 2023
9 May 2023
Amount
Supply,laying and testing in replacement of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with stranded aluminium conductor of size 50 sqmm 3.5 core as per IS 7092 Pt-I complete all as specified and as directed.
All as per item No 1 here in above but of size 25 sqmm 4 core and ditto-
All as per item No 1 here in above but of size 16 sqmm 4 core and ditto-
All as per item No 1 here in above but of size 10 sqmm 4 core and ditto-
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for pole / cable / foundation etc including getting out in soft /loose soil complete all as specified and directed.
Excavation in trenches in any type of soil not exc 1.5 mtrs wide and exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed.
Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick after cable are laid and tested complete all as specified and directed.
Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directed at a level not exc.1.5 mtr above the ground level complete all as specified & directed.
M&L for PCC cable cover class LV type 1 flat size 250 mm x 150 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed.
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable incl spreading, levelling, watering and consiolidation complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles all as specified and directed by Engr-in-Charge.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed by Engr-in-Charge.
M&L for steel tubing galvanised, light grade complete with fittings laid in trenches/ fixed along with poles etc as protection to cables of size 50 mm dia bore complete all as specified and as directed.
M&L for cutting of road up to 0.75 m deep suitable for laying underground cables/MS tubes of any size/dia including GI pipe of 50 mm dia & making good the disturbed area to match with the existing level with cement concrete including removing the surplus soil to a distance upto 50 mtr complete all as specified and directed.
S&F in replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 65 power consumption 45 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors from junction box to security lights complete all as specified and directed.
S&F in replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 65 power consumption 70/72 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors from junction box to security lights complete all as specified and directed.
S&F in replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 65 power consumption 90 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors from junction box to security lights complete all as specified and directed.
S&F in replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 65 power consumption 120 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors from junction box to security lights complete all as specified and directed.
S&F in replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 100 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors as requirement at site complete all as specified and directed.
S&F in replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 150 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors as requirement at site complete all as specified and directed.
S&F in replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 250 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm 3 core through copper connectors as requirement at site complete all as specified and directed.
Supply, erection and connection in replacement of new Pre- streessed concrete poles 102 mm x 172 mm at top and 102 mm x 279 mm at bottom 9.0 mtrs long including making alternate white and black strips 30 cms height (05 Nos strips) numbering the poles by 2" height letters complete all as specified and directed.
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31) 9.0 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint incl taking down complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately.
S & F of GI brackets for street light fitting fabricated with GI tubing 32 mm dia for LED Street lights medium grade 1.2 mtr length and bending to angle of 120 degree incl mild steel flat iron clamp fabricated with mild steel flat iron 32 x 5 mm with nut, bolt & washers suitable for fixing of GI bracket complete all as specified and directed.
S&F of kiosk box for luminaires ,weather proof made out of PVC/HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of copper bus bar 4 nos of 16 Amps with 6 Amp MCB single pole , of minimum size 300x200x125mm, IP 66 fixed on pole with MS, clamps 30x5mm with necessary nuts, washer and incl. applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box complete all as directed
M&L for earthing complete including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 3 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead 4.0 mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe and watering pipe shall be 20 mm ore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc. complete all as directed. Note : The conctrete pit shall be PCC 1:3:6 type C1, 40 mm thick PCC slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No.5 of MES SSR Part-1 (ii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbows etc shall be deemed to included in the quoted rate.
Supply & fixing of three phase 415 v automatic street light timer switch of capacity 12 KW using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 66 degree of ingress three phase 12 KW lightning load capacity including mounting bracket , cable glands, openable doors with lock complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 12 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB rating 40 Amps - 03 Nos (b).Contactor rating 40 Amps - 03 Nos (c).Out put MCB rating 40 Amps - 03 Nos (d).Three phase circuit wiring minimum 10 Sqmm multistranded copper wire. (e)Model No :- SWADEEP -66-12KW 3 P.
Supply & fixing of single phase automatic street light timer switch of capacity 8 kw using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 66 degree of ingress single phase 8KW lightning load capacity including mounting bracket , cable glands, openable doors with lock complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 8 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB rating 63 Amps - 01 Nos (b).Contactor rating 63 Amps - 01 Nos (c).Out put MCB rating 63 Amps - 01 Nos (d).Single phase circuit wiring minimum 16 Sqmm multistranded copper wire. (e)Model No :- SWADEEP -66-8 KW1P. Make :- Kakatiya Energy Systems Ltd
S&F & testing commissioning of outdoor type bus bar panel pedestal dust and vermin proof, IP65 class protection, CPRI approved MS cubical panel board made of 3.15mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of bus bar of 300 Amp capacity & MCCB 200 Amp capacity 4 pole (Ics = Icu = 100%) including one coat of red oxide and two coat of enamel paint powder coated, mounted on channels and PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed.
S&F & testing commissioning of outdoor type bus bar panel pedestal, dust and vermin proof, IP65 class protection, CPRI approved MS cubical panel board made of 3.15mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of bus bar of 300 Amp capacity & MCCB 160 Amp capacity 4 pole (Ics = Icu = 100%) including one coat of red oxide and two coat of enamel paint powder coated, mounted on channels and PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed.
Taking out under ground, LT cables, different sizes, by excavation and earth work in any type of soil, removing bricks or PCC tiles of any size, re-laying in the same trenches or re-routing after rectification of fault as required complete all as specified and directed NOTE:- (i) Joints & Jointing materials, new cable, additional bricks/PCC Covers, sand shall be measured & paid for separetely. (ii) Retrieved serviceable bricks or PCC cable cover and sand shall be re-laid on the cable & the cost for the same is deemed to be included in the unit rate.
M&L fo replacement of TPN HRC type switch fuse unit of 415 Volt 50 Hz three phase of capacity 32 Amp including MS box with backelite fuse & fuse carrier fittings , operating insulated handle, top cover necessary locking arrangemnts etc as per IS/IEC 60947 1&3 including necessary wall mounting fitting as directed including taking down the existing all as specified and directed. Make : INDOASIAN / L&T/Havells
Description all as per item No 33 above but of capacity TPN 63 Amp and ditto-
Description all as per item No 33 above but of capacity TPN 100 Amp and ditto-
Description all as per item No 33 above but of capacity TPN 200 Amp and ditto-
S & F in replacement of MCCB, 04 Pole, capacity 40 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) in the existing panel with suitable connecting copper terminals at site complete all specified and directed.
Description all as per item No 37 here in above but of capacity 63 Amps with ultimate breaking capacity 16 KA .
Description all as per item No 37 here in above but of capacity 100 Amps with ultimate breaking capacity 25 KA .
Description all as per item No 37 here in above but of capacity 160 Amps with ultimate breaking capacity 25 KA.
Description all as per item No 37 here in above but of capacity 200 Amps with ultimate breaking capacity 25 KA .
Description all as per item No 37 here in above but of capacity 250 Amps with ultimate breaking capacity 35 KA.
S&F in replacement ON load changeover switch 415 volt 3 Phase for mounting on PANEL with mounting arrangementsof capacity 63 Amp 4 pole all as specified.
S&F in replacement ON load changeover switch 415 volt 3 Phase for mounting on PANEL with mounting arrangementsof capacity 100 Amp 4 pole all as specified.
S & F in replacement off Load Change over switch 4 pole 415 Volt 50 HZ side operated 200 Amp in SS enclosure with side handle
S & F in replacement off Load Change over switch 4 pole 415 Volt 50 HZ side operated 100 Amp in SS enclosure with side handle
S & F in replacement off Load Change over switch 4 pole 415 Volt 50 HZ side operated 63 Amp in SS enclosure with side handle
S & F cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint incl taking down existing complete all as specified and directed.
S&F Aluminium conductor steel reinforced ( ACSR ) of any size and of any description as per site requirement on LT poles /lines incl stringing ,tightening binding to insulators with aluminium wire making and connecting jumpers ,connections and incl connecting , commissioning and testing etc complete and directed .
M&L for painting of steel tubuler 11/9 mtr poles any type complete incl flat iron clamps, D clamps, Stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface initally & applying one coat of red oxide, applying two coat of aluminum paint over the red oxide, marking with alternate white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint and also including numbering of poles with white paint are located on different locations complete all as specified and directed by Engr-in-Charge.
M & L for painting of steel cross arm, bracing supports of 11/9 mtr PCC poles any type incl flat iron clamps, D clamps, stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint incl prepration old painted surface and applying cemente based paint over cemented portion of PCC poles, marking with alternator white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint, numbering of poles complete all as specified and directed.
Disconnecting power supply from defective /unserviceable street light/ security light/ high mast light/flood light fitted on 11 mtr/9 mtr/8.5 poles and testing / checking for defects, testing LED drivers, fuse, testing kisok box, over head line connection, tightening of loose nuts bolts of GI brackets on pole, checking connecting wire from pole etc and fixing the repaired / services light fittings on poles and testing & commisining of light. Note :- (i) All spare like LED drivers, connecting cable, pole box, MCB in pole box etc and refixing in replacement will be measured & paid separately under relevant item. (ii) All necessary T&P (like ladder of suitable height and safety belt) for testing & repair of light fitting will be provided by contractor with out any extra cost. (iii) Contractor will depute one technician and one helper daily repairs & maintenance of security lights as directed (iv) Contractor will carry out daily repair & maintenance of security light as directed. Contractor has to understand the nature of wks under this item & quote his rate accordingly. (v) Complaints of unserviceable light fittings will be given by JE E&M to contractor/contractor’s rep to technician on mobile phone followed by writing. Contractor has to arrange required material, T&P & safety equipments to repair the security light within 72 hours from the time of intimation failing which a penality of Rs. 500/- per light per day (beyond 72 Hrs) will be charged and recovered from contractor dues.
Supply and fix garden light crompton heritage 20 watt land scap lighting,LPTH-20 CDL. including all connected items complete all as specified and direcetd.
M&L for decorative LED post top gate light with IP 65 protection resistant to impact and corrosion,glair free and better uniformity all as specified and directed.Make CG/wipro or equipvalent.(wipro Pat No-LP 07-431-xxxC2-CL.)
M&L for decorative LED bollard stailess steel 9 watt weather proof light (warm white)with acrylic diffuser complete with all accessaries all as specified and directed.
S&F in replacement of LED drivers of LED streeet light /flood light of any make , of capacity 30 watts to 60 watts including replacement of burnt drivers carefully and as direcetd
Description all as per item no. 56 above but 70 watts to 90 watts and ditto-
Description all as per item no. 56 above but 100 watts to 150 watts and ditto-
S&F in testing & commisioning of LED bulb panel inside LED flood/security light of capacity 45 watt to 70 watt including taking down old unserviceable LED panel including replacement through soldering etc complete. Qouted rate includes necessary part reuired for repalcement for commisiioning of LED lights.
Description all as per item no 59 of above but size 90 watt to 150 watt
Restringing of HT overhead line conductor comprising of any size ACSR conductor after opening from insulators, including restringing same and winding on insulator with proper size of binding wire upto permissible sag including cutting, trimming and vending of branches along HT line and removing of creepers from poles/conductors complete all as directed.
Cutting and trimming of tree branches of any girth all around the HT/LTover head lines upto two mtr from all around the over head lines complete and removing the cut branches from site to a distance not exc 50 mtr all as directed
S&F MCB 63 Amp TPN for street light complete all as specified and as directed.
S&F MCB 63 Amp spn for street light complete all as specified and as directed.
S&F MCB 40 Amp spn for street light complete all as specified and as directed.
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 04 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd.
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated copper conductor three core cable flat or circular of size 1.5 sqmm for street light connections etc complete all as specified and direcetd.
M/S Kharya Associates
M/s Ravi Traders
MTR GROUP & COMPANY
M/S Ritu Tandon
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .