Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC KAHIKUCHI MARKET P O AZARA ASSAM 781017 | AZARA | KAMRUP | ASSAM | 781017 | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.6 L+₹59,149.10 (2.57%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹24.9 L+₹1.9 L (8.35%)Rejected-AOC AZARA THAKURIAPARA AZARA ASSAM 781 017 | KAMRUP METRO | ASSAM | 781017 | L3 | Rejected-AOC L3 | |
| 4 | L4₹25.2 L+₹2.2 L (9.72%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹28.0 L+₹5.0 L (21.8%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹59,000
Closing Date
19 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati 15 Assam Pin 781015 Tele 0361 2841626
REPAIR MAINT OF HT DISTRIBUTION SYSTEM AND CONNECTED ITEMS AT BORJHAR
2021_MES_494760_1
CWE(AF)/BOR/TOKEN-53 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Borjhar
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE AF Borjhar
₹59,000
Yes
9 Feb 2022
15 Dec 2021
21 Jan 2022
15 Dec 2021
19 Jan 2022
30 Dec 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in soft / loose soil complete all as specified and directed. Note: No mechanical excavator will be allowed at site.
All as per Item No 1 above but depth exceeding 1.5 m and n exc 1.5 m wide and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point, complete all as specified and as directed.
Material and Labour for dry sand cushioning with coarse sand in trenches for protection of underground electric cable 8cm deep before laying the cable and 15cm thick after laying & stretching of cable complete all as specified and as directed. (Note:- Only punned thickness of 18cm shall be measured and paid)
Supply and laying factory made reinforced precast concrete cable cover, class EHV, type 2 with peak of size 450mm x 180mm x 40mm, embosed "MES HT CABLE" at top for protection of UG cable complete all as specified and directed.
Re-laying only reinforced precast concrete cable cover of any type, in trenches for UG cable protection (Serviceable reinforced precast concrete cable cover obtained from taking down of cable shall be used), complete all as specified and directed.
Taking out old unserviceable 11KV, HT UG cable from existing trenches/duct/ HT poles of any cross sectional area including disconnecting, PCC covers, GI Pipe etc. of any descriptions, segregation of serviceable materials viz cable cover, GI Pipes, UG cables etc. and keep in safe custody for re-use including necessary excavation and earth work complete all as specified and directed NOTE : Serviceable cable covers, cables and GI pipes shall be kept aside for re-use as directed by the engineer-in charge.
Laying only old serviceable HT cable of size 95-120 Sqmm 3 core laid in trenches/duct all necessary fixing arrangements such as lugs, glands and terminals etc complete all as as directed.
Supply, laying, jointing and testing of UG electric power cable, heavy duty 11KV (E) grade, XLPE insulated, screened, bedded, galvanised steel strip or wire armoured, aluminium conductor of cross sectional area 120 sqmm, 3 core, laid in trenches/cable duct/under road crossing / on poles / panels complete all as specified and as directed.
All as per Item No 10 above but 95 sqmm 3 core complete all as specified and directed. Note for Item No 08 to 11: HT Cable shall be laid in civil area i.e. near to state/national highway. Any permission required from civil authority for laying of the cable shall be obtained by the contractor before execution of the works without any extra claim to the department.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm including testing after jointing complete all as specified and as directed. Make: Densons/Cabseal/3M /Raychem.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm including testing after jointing complete all as specified and as directed. Make: Densons/Cabseal/3M.
Supply & laying in trenches GI pipe light grade 100 mm bore for cable protection including all fittings, suitable clamps and sealing ends of pipe with suitable bituminous wooden wedge complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in bituminous macadam road/hardstanding complete all as specified and directed. Note: No mechanical excavator will be allowed at site.
Material and Labour for PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregates) as in foundation filling and mass concrete including necessary formwork complete all as specified and as directed.
Material and Labour for PCC (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for horizontal boring across the existing road without disturbing the road surface for inserting 100 mm bore GI pipe, complete all as directed. Note: GI pipe shall be measured and paid for separately under respective item.
Taking down unserviceable/rusted HT poles of any size/type complete all as specified and directed
M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) including painting with two coats of synthetic enamel paint of sky blue colour (upto 1.5 m above PCC copping) and aluminium paint for balance portion of the pole over a coat of red oxide primer complete all as specified and directed. (Note: Earth work and PCC foundation etc shall be measured and paid seperately under relevant item)
Material and labour for trimming of branches of tree of girth 80mm to 125mm touching HT electric overhead line by climbing up tree or using ladder of required height and making clear about 3 metre in radius and carrying & depositing where directed not exc 50 m complete all as specified and as directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and as directed. Make : 3M or equivalent
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level sourrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filled in alternate layers etc and connected to and including 32 x 6 mm GI strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40 mm bore GI pipe connected to main control board and GI pipe medium grade 15 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50 mm thick reinforced with 8 mm TMT bar 100 mm C/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20 mm graded aggregate) including excavation and earthwork, disposal of surplus soil to a distance not exceeding 50 m and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and directed.
Material and labour for chemical earthing complete with copper plate electrode of size 90 cm x 60 cm x 5 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 m below normal ground level connected to copper earth strip 50 x 6 mm, all as shown on electrical plate No 3 of SSR Part-I, using 5 Nos alternate layers of charcol and salt crystal and a final layer of Magnesium sulphate of 5 cm thickness to be provided and connected to earth test point including 25 mm bore GI medium grade pipe for watering with funnel and wire mesh and 63 mm bore GI light grade pipe for protection of earth strip and providing water supply connection from nearest water supply point and testing including PCC chamber complete all as specified and as directed. Note :- (i) The unit rate shall deemed to include for earth work in hard/ dense soil, PCC (1:2:4) type B-1 chamber, RCC (1:1.5:3) cover 50 mm thick reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways, funnel with watering pipe 25 mm bore medium grade, GI protection pipe light grade 63 mm bore and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub-heading earthing, specified on SSR Part-II. (ii) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on GI plate above 45 cm from GL as per colour code followed in AF Station. (iii) If the desired earth resistance is not achieved during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissible. (iv) Copper strip shall be provided upto earth test points as directed.
Supply and fixing in repair earth continuity conductor or main earthing lead made of galvanized iron strip of size 32 mm x 6 mm as roof conductor/down conductor above ground level/ burried in ground fixed with saddles (made of Porcelain / PVC ) and screws at a distance 30 cm complete all as specified & as directed.
Supply and fixing in repair earth continuity conductor or main earthing lead made of Copper strip of size 32 x 6mm as roof conductor/down conductor above ground level/ burried in ground fixed with saddles (made of Porcelain / PVC ) and screws at a distance 30 cm complete all as specified & directed.
Supply & laying in trenches GI pipe light grade 50 mm bore for cable protection including all fittings, suitable clamps and sealing ends of pipe with suitable bituminous wooden wedge complete all as specified and directed.
M&L for writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high on LT switch gear, Panel/Pole etc complete all as specified and as directed.
Material and Labour in repair for mild steel cross arms, bracing, supports, clamps and back plates fabricated from structural steel section conforming to Fe - 290 (Gde E-165) including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape/size as directed including painting with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and as directed.
Supply and fixing in repair Disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, brown colour, single disc assembly for tension with tension clamp for conductor, working pressure 11000 volts grade complete all as specified and directed.
Supply and fixing in repair switches air break, gang operated, Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level for current rating upto 400 amps, 11000 Volts grade complete all as specified and as directed.
Supply and fixing in repair drop out fuse unit assembly (Channel type) complete with MS base frame and expulsion fuse and six Nos of porcelain insulators for current rating 400 amps, 11000 Volts grade complete all as specified and as directed.
Supply, installing, testing and commissioning in repair HT lightening arrester expulsion type complete with all fittings discharging capacity 65 KA, 11000 volts grade complete all as specified and directed by Engr-in-Charge.
Supply, stretching, fixing, testing and commissioning in repair OH, ACSR conductor of any type / size on existing / new HT poles including fixing to insulators with binding wire complete all as specified and directed.
Supply and fixing in repair drop out fuse elements 11KV, 10-25 Amps rating complete all as specified and as directed.
Supply and fixing in repair drop out fuse elements 11KV, 40 Amps rating complete all as specified and as directed.
Supply and fixing in repair drop out fuse elements 11KV, 60 Amps rating complete all as specified and as directed.
Supply and fixing in repair fibre tube with metal fitting on both ends of 11KV grade cable complete all as specified and as directed.
Supply and fixing in repair Vice type taps, consisting of two brass plates and one bolt and nut for connecting 2 equal or unequal size conductors of dia 10-14mm in GOD or DO fuse or ACSR conductor including treatment of taps and ACSR conductor with conducting jelly complete all as specified and as directed.
Supply and fixing in repair anti-climbing device, spikes type fabricated out of MS. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross-section of the pole complete all as specified and directed.
Supply and fixing in repair Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm including testing after jointing complete all as specified and as directed. Make: Densons/Cabseal/3M/Raychem.
Supply and fixing in repair Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm including testing after jointing complete all as specified and as directed. Make: Densons/Cabseal/3M/Raychem.
Supply and fixing Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and directed.
Material and labour for cable route indicator of size 300mm (W), 800mm(H), 100 mm (T) of PCC (1:2:4) type B0 (using 12.5mm graded aggregate), install the same on ground by PCC work of (1:3:6) type C1 (size 310mm x 150mm x 300mm), engraved the words in Block letter of size 5cm height and 2cm width "MES 11 KV CABLE" or "MES CABLE JOINT" including rendering 10mm thick in CM (1:3) including necessary excavation and earthwork and applying two coats of weather coat paint over a coat of primer complete all as directed.
M.S. Construction
M/s Lalowari Electricals
Purbanchal Construction Co
M/S TRADE CENTRE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .