GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
REPAIR/REPLACEMENT OF WATER SUPPLY SYSTEM,DG SETS OF PUMP HOUSES AND USE OF CHEMICALS ,CALCIUM BASED GRANULE ,LIME DEHYDRATED ,BLEACHING POWDER AND CONNECTED ITEMS UNDER GE(W)PATHANKOT
2023_MES_604013_1
GE/PKT-17/2023-24
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (WEST) PATHANKOT
As per tender and NIT documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹49,000
4 Aug 2023
17 Jun 2023
30 Jul 2023
17 Jun 2023
28 Jul 2023
15 Jul 2023
Amount
Repair, servicing and comprehensive maintenance of DG Sets of any make of the following capacities incl replacement of defective /burn out parts by new parts such as filters,gaskets,V belts,Engine oil , rubber hoses,cleaning of alternator by vacuum cleaner and greasing of bearing with cother connected work for the cap 200 kVA complete all as specified and directed by Engr-in-charge. And supply only following consumable parts. (NOTE: Cost factorof labours for servicing & fixing of parts shall be deemed to be included in unit rate. However worn out & unservicable parts to be replaced will be measured and paid separately as supply only. Make of spare parts same as of DG set or as per sample. Servicing will be done as per manufacturer instructions.
Diesel filter element with O rings
Engine oil filter with by pass filter element with O rings
Air filter element
Fan belt
Rubber hose pipe set with clamp
All as per Srl Item No 01 here-in-before but DG set cap 63/62.5 kVA of any Make & type
Diesel filter element with O rings
Engine oil filter with by pass filter element with O rings
Air filter element
Fan belt
Rubber hose pipe set with clamp
All as per Srl Item No 01 here-in-before but DG set cap 20-40 kVA of any Make & Type
Diesel filter element with O rings
Engine oil filter with by pass filter element with O rings
Air filter element
Fan belt
Rubber hose pipe set with clamp
Supply & pouring in sump/topping up of Engine oil of grade 15W-40/20W-50 in engine or replacement from Engine.
Supply & filling coolant in radiator in any type of DG set at various loactions all as directed by Engr-in-charge
S&F in replacement battery lead of copper conductor 16 sqmm single core 1.5 mtr long fitted with battery lead terminal one side and other side with brass ternminal,clamps, copper lugs and connection as directected by Engr-in- Charge.
Supply & pouring of Electrolyte for lead acid battries in sealed container all as directed by Engr-in-charge
Disconnecting of radiator from engine of DG sets of capacity 200 kVA and taking it to workshop for overhauling ,cleaning, descaling with restore plus solution ,welding and brazing as required for repair of water leaking, refixing it at site duly repaired all as directed by Engineer -in-Charge.
All as per srl Item No. 8 here-in-before but DG set cap 62.5/63 kVA.
All as per srl Item No. 8 here-in-before but DG set cap 20-40 kVA.
M&L for Cleaning of fuel tank both internal & external by removing all the dust/sadiments etc incl writing of tank cap, date of cleaning and next due date of cleaning incl replacement of fuel cap and replacement of fuel pipe (tank to DG set) complete for Cap 200 kVA of any make & type all as specified and directed by Engr-in-charge.
All as per srl Item No11 here-in-before but DG set cap 20-63 kVA
S&F in replacement of water pump assy of DG set cap 200 kVA of any make & type all as directed by Engr-in-charge
All as per srl Item No. 13 here-in-before but DG set Cap 62.5/63 kVA.
All as per srl Item No. 13 here-in-before but DG set Cap 20-40 kVA .
Taking out FIP from DG set of cap 200 kVA of any make & type,transportation to authorised service centre for overhauling and re-calibration and re-fixing to DG set including replacement of necessary spare parts such as delivery valves, plunger 'O' ring spring, fuel injector pipe set, etc. complete all as specified and as directed by Engr-in-charge.
All as per srl Item No. 16 here-in-before but DG set Cap 62.5/63 kVA.
All as per srl Item No. 16 here-in-before but DG set Cap 20-40 kVA .
Rapair and over hauling of self starter 12 V of any DG set (spare parts will be measured and paid separately as supply only).
Supply only field coil
Supply only armature rewinding
Supply only carbon bushes
Supply only Clutch bushes
Supply only pinion assy
Rapair and over hauling of self starter 24 V of any DG set (spare parts will be measured and paid separately as supply only).
Supply only field coil
Supply only armature rewinding
Supply only carbon bushes
Supply only Clutch Bushes
Supply only pinion assy
M&L for electrical device of alternator 12 Volt replacement of rectifire, voltage regulator , slip rings , carbon brushes and terminal etc complete all as specified and as directed.
All as per srl Item No. 21 here-in-before but cap 24 V.
Scrapping of old paint from DG set of any make of capacity 200 kVA , preparation of old painted surfaces for repainting and Material and labour for spray painting to DG set of any capacity with synthetic enamelled paint of superior quality over a coat of red oxided after scratching the old paint, making the surface smooth with sand paper etc. writing letter SM No/MES No, DG capacity & other by paint or glossy tapes complete all as specified and directed by Engr-in -Charge
All as per srl Item No. 23 here-in-before but DG set cap 62.5/63 kVA.
All as per srl Item No. 23 here-in-before but DG set cap 20-40 kVA .
Taking out unserviciable door lock incl all hinges of DG set canopy and supply & fixing new lock with keys and all hinges as per sample andall as per directed by Engr-in-charge.
M&L for replacement of MS coupling with new coulping rubber bush /rubber disc by taking coupling from engine and generator/alternator joint of 200 kVA Cap DG set of any make & type complete all as specifies and as directed.
All as per srl Item No. 27 here-in-before but DG set cap 62.5/63 kVA
All as per srl Item No. 27 here-in-before but DG set cap 20-40 kVA
S&F in repair asbestos rope 6 mm dia wrapped over the exhaust pipe complete
S&F in repair anti vibration pads suitable for 40/63/62.5 kVA DG set complete all as specified and as directed by Engr-in-Charge. Make : Dunlop or technocommercially or equivalent in other makes as approved by AGE E/M.
M&L for 200 KVA DG set, panel board wiring with 4 sqmm Single Core multistranded copper wire cable, including taking out of existing wiring complete all as directed by Engineer -in- Charge
All as per srl Item No. 32 here-in-before but DG set cap 62.5/63 kVA
All as per srl Item No. 32 here-in-before but DG set cap 20-40 kVA
S&F in replacement battery Charger 12 Volts , 6 amps with incoming and outgoing connections including all connected works deemed inclusive in the quoated rates complete all as directed by Engineer -in-Charge.Make Sucam/AMCO/Sinetrac/BCH
All as per srl Item No. 35 here-in-before but DG set cap 24V.
S&F in replacement AVR (Automatic Voltage Regulator) of DG set of capacity 200 kVA of any make & type all as directed by Engineer-in-Charge.
All as per srl Item No. 37 here-in-before but DG set cap 63/62.5 kVA
All as per srl Item No. 37 here-in-before but DG set cap 20-40 kVA
S&F in replacement Turbo charging unit for 63/62.5 kVA DG Set complete all as specified and directed by Engr-in-Charge. Make:Kirloskar,Cummins,Greaves
S&F in replacement Oil pressure Guage suitable for 20-200 kVA DG set of any Make DG set
Disconnecting incoming / outgoing cable connection from alternator of 200 KVA DG set and taking out from DG set room checking carefully and transporting to auth workshop for repair and rewinding of alternator dismentling into parts and cutting the burnt/damage copper winding wire from alternator / stator cleaning slots and rewinding the stator/alternator with super enamelled copper winding wire of existing gauge & size and insulation paper etc complete varnishing of rewinded alternator replacement of carbon brush set bearing set etc complete and transporting the alternator to DG set room coupling with DG set and testing complete include water load test all as specified and directed by Engr-in-charge. (NOTE: All neccessary T&P for dismantling,transporting and installation cost is deemed in this item and nothing extra shall be admissible).
All as per srl Item No. 42 here-in-before but DG set cap 63/62.5 kVA
All as per srl Item No. 42 here-in-before but DG set cap 20-40 kVA
S&F in replacement of u/s Battery with standard lead acid 12 volt DC, 150 AH to be fitted on DG set including connecting S/C copper lead of size 10 Sqmm dia with two nos of bty terminal complete all as specified and directed. Make Exide/Amaron/Tata Green /Luminious
S&F in replacement of controller including relays, PCBs & mimic visual display complete with ON/OFF switches and phase indicators complete for 200 kVA DG set of any make & type all as per specified and as directed.
All as per srl Item No. 46 here-in-before but DG set cap 63/62.5 kVA
All as per srl Item No. 46 here-in-before but DG set cap 20-40 kVA
S&F in replacement of MCCB 4 pole 415 volt 50 HZ of capacity 63Amps adjustable thermal and fixed magnetic and current breaking capacity 25 KA.with incoming and outgoing connections including all connected works deemed inclusive in the quoated rates
S&F in replacement of MCCB 4 pole 415 volt 50 HZ of capacity 200Amps adjustable thermal and fixed magnetic and current breaking capacity 35 KA.with incoming and outgoing connections including all connected works deemed inclusive in the quoated rates
S&F in replacement of ON load change over switch 415 volt 50 HZ capacity 160 Amps, open execution with incoming and outgoing connections including all connected works deemed inclusive in the quoated rates
S&F in replacement of ON load change over switch 415 volt 50 HZ capacity 100 Amps, open execution with incoming and outgoing connections including all connected works deemed inclusive in the quoated rates.
S&F in replacement of copper tube (Thimbles) terminal heavy duty of size 95 Sq.mm.
S&F in replacement of copper tube (Thimbles) terminal heavy duty of size 70 Sq.mm.
S&F in replacement of copper tube (Thimbles) terminal heavy duty of size 150 Sqmm.
S&F in replacement of copper tube (Thimbles) terminal heavy duty of size 120 Sq.mm
S&F in replacement of indicator lamp (LED type) fitting with neon lamp in three colour (Red/Green/Yellow).
M&L for Overhauling of DG set of any make & type of capacity 63 KVA by dismantelling the parts of DG set replacing the worn out parts, cleaning/servicing thoroughly and testing on load after completion of work including all spare parts as required at site for smooth functioning of DG set complete as pe all as specified and as directed by Engr-in-Charge.
S&F in replacement electronic governor suitable for DG set of capacity 63 KVA complete with electric actuator , electronic speed control unit and magnetic sensor all as specified and directed by Engr-in-Charge.
S&F in replacement of Exhaust system/ silencer For DG sets of capacity 62.5/63 KVA as required at site for smooth functioning of DG set complete all as specified and as directed by Engr-in-Charge.
Supply, fixing and making connections in repairs Hour meters 220-240 V, AC suitable for any type & capacity DG sets complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Self starter 12 V, DC for diesel engine driven water cooled DG sets complete as per sample all as specified and as directed by Engr-in-Charge.
Taking up or down GI tubing including connections carefully, for relaying or removal to store all as directed and specified by Engr-in-Charge of size 15mm bore. Note- Excavation and earth work shall measured and paid saperately under respective item.
All as per srl Item No. 63 here-in-before but size 20mm bore
All as per srl Item No. 63 here-in-before but size 25mm bore
All as per srl Item No. 63 here-in-before but size 40mm bore
All as per srl Item No. 63 here-in-before but size 50mm bore
All as per srl Item No. 63 here-in-before but size 80mm bore
All as per srl Item No. 63 here-in-before but size 100mm bore
Supply, laying and testing GI Pipe medium grade with all fitttings laid in trenches of size 15 mm dia. complete all as specified and directed Make :- TATA/JINDAL
All as per srl Item No. 64 here-in-before but size 20mm bore
All as per srl Item No. 64 here-in-before but size 25mm bore
All as per srl Item No. 64 here-in-before but size 40mm bore
All as per srl Item No. 64 here-in-before but size 50mm bore
All as per srl Item No. 64 here-in-before but size 80mm bore
All as per srl Item No. 64 here-in-before but size 100mm bore
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth in any type of soil for repairing/ replacement of CI & GI pipes including getting out excavated earth complete all as specified and directed.
Returning, filling in trenches incl spreading and leveling, watering and well ramming in layers n.exc. 25 cm thick all as specified.
Removal of excavated soil to a distance n.exc. 50 mtr and depositing the same where directed at a level n.exc. 1.5 mtr above starting point complete all as specified
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 1,31,480.50). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 5% (Five percent) of the accepted contract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249 (c) If makes of the item is not mentioned in respective item or tender should be from approved make list of WC or as per existing sample should be decided by Engg-in Charge
M/S MALHOTRA ENGINEERS
DASHMESH BUILDERS
M/s. Aggarwal Engineers
JAI DURGA CONSTRUCTION CO
Om Sai Ram Builders
KHOSLA ENGINEERS BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .