Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹14.5 L+₹1.5 L (11.2%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹20.2 L
EMD Value
₹40,400
Closing Date
2 Oct 2021, 6:00 pmClosed
MAJ JP SAHOO
GE 872 EWS, C/O 99 APO
REPAIRS/MAINT TO INTERNAL ELECTRIFICATION, REPAIRS/ MAINT/ SERVICING TO VARIOUS TYPES OF FANS AND GEYSER AND REPAIRS/ MAINT/ SERVICING TO COOLING APPLIENCES, REPAIRS/ MAINT OF EXTERNAL WATER SUPPLY, REPAIRS/ MAINT TO LT EXTERNAL ELECTRIFICATION AND R
2021_MES_466072_2
8631/T-31/E8
Open Tender
Miscellaneous Works
Item Rate
183 days
NLP
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE 872 EWS
₹40,400
Yes
27 Oct 2021
15 Sept 2021
4 Oct 2021
15 Sept 2021
2 Oct 2021
20 Sept 2021
15 Sept 2021 - 18 Sept 2021
Amount
REPAIRS/MAINT TO INTERNAL ELECTRIFICATIONS
M&L Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) complete from in any position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets (but excluding Light Fittings of any description), etc, Making Good Disturbed Surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 including providing Surface Treatment (Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Taking down/out unserviceable Sub-main Wiring from Batten/ Conduit/ PVC Casing Capping of any description, Making Good disturbed Portion/ Surfaces of Walls/ Floor/ Ceiling, etc. by using Cement Mortar 1:3 including providing Surface Treatment to match the Existing Treatment/ Finishes on Ground, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/BELL POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accom-modating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE CEILING/ EXHAUST/ FRESH AIR FAN POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire for ONE 6 AMP 5 PIN SOCKET OUTLET POINT on SAME BOARD, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 6 AMP 5 PIN SOCKET OUTLET POINT on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodat-ing Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 16 AMP 3/5 PIN SOCKET OUTLET POINT on INDEPENDENT BOARD, complete all as specified and all as directed.
M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :- (a) Cost of 3-Runs of Cables & 1-Run of PVC Casing Capping will deem to be included in the Quoted Unit Rate and the same also Mesured as ONE UNIT. (b) Sub-main Wiring will be measured existing PVC Casing Capping only. Wire required for looping, etc. as ordered will deem to be included in the Quoted UNIT RATE.
S&F PVC Casing Capping (ISI Marked) of size 25mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed.
S&F PVC Casing Capping (ISI Marked) of size 32mm including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out unserviceable PVC Casing Capping, complete all as specified and as directed
S&F PVC Rectangular Block of size 175x100x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F PVC Rectangular Block of size 200x150x50mm deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out unserviceable PVC Block, complete all as specified and as directed.
S&F Switch Piano Flush type, 6 Amp, Single Pole, 1-way, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Piano Flush type, 6 Amp, Single Pole, 1-way, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Piano, complete all as specified and as directed.
S&F Switch Socket Outlet 6 Amp, 3 Pin, Flush type and connecting up, complete all as specified and as directed.
S&F Switch Socket Outlet 6 Amp, 5 Pin, Multi-Plug, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Piano, complete all as specified and as directed.
S&F Switch Socket Combination 6 Amp, 5 Pin, Multi-Plug, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Socket combination 6/16 Amp, 5 Pin, Multi-Plug, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed.
S&F Switch Socket combination 6/16 Amp, 3/5 Pin, Multi-Plug, Flush type, 230 Volt AC and connecting up including Taking down/ out unserviceable Switch Socket Combination, complete all as specified and as directed.
S&F Pendant/Lamp Holder Ordinary with Insulated Body and connecting up, complete all as specified and as directed.
S&F Ceiling Rose Surface type, Bakelite 65x50mm 2 to 3 Terminal suitable for 230 Volt AC, 6 Amp and connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator 230 Volt AC, Rotary Stepped Electronic type 120/280 Volt including necessary Connection and connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator 230 Volt AC, Rotary Stepped Electronic type 120/280 Volt and connecting up including Taking down/ out unserviceable Fan Regulator, complete all as specified and as directed.
S&F LED Bulb 10 Watt, B 22, 230 Volt suitable for fixing in Normal Pendent/ Batten Holder including Taking down/ out unserviceable Bulb, complete all as specified and as directed. MAKE : HAVELLS, CAT No. LHLDEUEEML8R010 or equivalent in Make : BAJAJ/ CG/ PHILIPS
S&F LED Bulb 15 Watt, B 22, 230 Volt suitable for fixing in Normal Pendent/ Batten Holder including Taking down/ out unserviceable Bulb, complete all as specified and as directed. MAKE : HAVELLS, CAT No. LHLDDEEEML8R015 or equivalent in Make : BAJAJ/ CG/ PHILIPS
S&F LED Batten 18 Watt 4 Feet Cool Day Light including Taking down/ out unserviceable Batten, complete all as specified and as directed. MAKE : HAVELLS, CAT No. LHLDEUEEML8R010 or equivalent in Make : BAJAJ/ CG/ PHILIPS
S&F MCB Single Pole 6 to 32 Amp, 'C' Series 10 kA Breaking capacity, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F MCB Single Pole 40 to 63 Amp, 'C' Series 10 kA Breaking capacity, 240 Volt and connecting up including Taking down/out unserviceable MCB, complete all as specified and as directed.
S&F Factory Made MCB Distribution Board, SPN 2-way, 240 Volt AC, Single Door, Steel Phoshotised Powder painted with 200 Amp Neutral Bars, Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. MAKE : HAVELLS or equivalent Modal of LEGRAND/ L&T
S&F Factory Made MCB Distribution Board, SPN 4-way, 240 Volt AC, Single Door, Steel Phoshotised Powder painted with 200 Amp Neutral Bars, Earth Bar and connecting up including Taking down/out unserviceable MCB DB, complete all as specified and as directed. MAKE : HAVELLS or equivalent Modal of LEGRAND/ L&T
REPAIRS/MAINT TO FANS
M&L Taking down unserviceable Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Air Circulator Fan of any Make & Size after disconnecting and removing to AGE E/M Store Yard at NLP for Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Re-hanging the same in Original Position after repaired and providing Electric Connection, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involved to make the Fan completely Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Rewinding & Other Parts required to be replaced will be Measured and Paid separately as "S&F"/"M&L" under relevant Items.
S&F Ball Bearing (size as per existing one/ as approved) suitable for Ceiling Fan 1200/1400mm Sweep including Taking down/out unserviceable Ball Bearing, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
S&F Condenser 2.0/2.5 mfd suitable for Ceiling Fan of any Make and Size including Taking down/out unserviceable Condenser, complete all as specified and as directed.
S&F Fan Blade Aluminium (size as per existing one/ as approved) suitable for Ceiling Fan 1200mm Sweep of any Make/Model, Aero dynamically Balanced and Screwed with suitable size Mild Steel Screws including Taking down/out unserviceable Fan Blade, complete all as specified and as directed.
M&L Frame suitable for Exhaust Fan 380/400mm Sweep with Mild Steel Flat and fixing with Bolts, Nuts, Washers, etc. as required/ordered including Taking down/out unserviceable Frame, complete all as specified and as directed.
S&F Gun Metal Bush (size as per existing one/ as approved) suitable for Cabin/ Ceiling/ Exhaust Fan of any Make and Model including Taking down/out unserviceable Bush, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
M&L Louver Shutter suitable for Exhaust Fan 380mm Sweep of any Make/ Model, fixing with Bolts, Nuts, Washers, etc. and grouting to Brick/PCC Block Walls including Taking down/out unserviceable Louver Shutter, complete all as specified and as directed.
M&L Louver Shutter suitable for Exhaust Fan 400mm Sweep of any Make/ Model, fixing with Bolts, Nuts, Washers, etc. and grouting to Brick/PCC Block Walls including Taking down/out unserviceable Louver Shutter, complete all as specified and as directed.
M&L Mild Steel Down Rod 15mm nominal dia and 18" long, heavy duty, duly painted in matching Colour including Taking down/out unserviceable Down Rod, complete all as specified and as directed.
M&L Mild Steel Down Rod 15mm nominal dia and 24" long, heavy duty, duly painted in matching Colour including Taking down/out unserviceable Down Rod, complete all as specified and as directed.
M&L Mild Steel Down Rod 15mm nominal dia and 36" long, heavy duty, duly painted in matching Colour including Taking down/out unserviceable Down Rod, complete all as specified and as directed.
M&L Transporting Ceiling Fan 1200mm Sweep from AGE E/M Store Yard at NLP to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Exhaust Fan 300/ 380mm Sweep from AGE E/M Store Yard at NLP to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Wall/ Cabin Fan 400mm Sweep from AGE E/M Store Yard at NLP to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Pedestal Fan of any Sweep from AGE E/M Store Yard to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Taking down Ceiling Fan of any Sweep from any Situation after disconnect-ing, Preparing old Painted Surfaces of Fan including Cleaning, Washing, Rubbing and Filling Cavities with Filler, applying One Coat of Synthetic Enamelled Paint (as approved) with Spray Painting Machine and Writing MES No. with Black Paint, Re-hanging the Fan in Original Postion & Re-connecting and Testing, complete all as specified and as directed.
REPAIRS/MAINT TO GEYSERS
M&L Opening Defective Water Cooler of any Capacity/ Make/ Model/ Type for Checking/Repairing, Removal of Blockage by Flushing Out, Brazing (as required) Suction & Discharge Pipes for Making the System Fully Leakeage Proof, Cleaning thoroughly Cooling Coil to achive Proper Cooling effect, Replacing unserviceable Compressor & Other Parts and Re-assembling after necessary repaired & Testing, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Water Cooler Functional, even if not notified by JE/ Engineer-in-Charge, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items and the Quantities are Provisional.
S&F Base Assembly Gasket of any shape and size, suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Base Assembly Gasket, complete all as specified and as directed.
S&F Base Assembly (Inner), Brass Chromium plated complete of any shape and size with Inlet, Outlet, Thermostate Slot, drain plug, Clamp or Bolts to fixing Heating Element as existing Shape suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Base Assembly (Inner), complete all as specified and as directed.
S&F Brass Chromium plated Connection 350mm long with Brass Chromium plated Adaptor and Making connection to Inlet & Outlet suitable for Electric Water Heater 25/50 Litre capacity of any Make/Model including Taking down/ out unserviceable Connection with Adaptor, complete all as specified and as directed.
S&F Fusible Plug in existing Shape suitable for Electric Water Heater 25 Litre capacity of any Make/Model and Testing including Taking down/out unserviceable Fusible Plug, complete all as specified and as directed.
S&F Glass Wool (Insulation Materials) superior quality (as approved) suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking out unserviceable Glass Wool, complete all as specified and as directed.
S&F Heating Element 1.5 KW 230 Volt AC suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed.
S&F Heating Element 2.0 KW 230 Volt AC suitable for Electric Water Heater 50 Litre capacity of any Make/Model including Taking down/out unserviceable Heating Element, complete all as specified and as directed.
S&F Indication Lamp Assembly consisting Red & Green in Colour of any shape and size, 230 Volt suitable for Electric Water Heater 50 Litre capacity of any Make/Model including Taking down/out unserviceable Indication Lamp, complete all as specified and as directed.
S&F Inner Shell (Inner Tank), ISI marked, made out of Copper Sheet 22 Gauge thick suitable for Electric Water Heater 25 Litre capacity of any Make/Model in existing Shape & Size including Taking down/out unserviceable Inner Shell, complete all as specified and as directed.
S&F Inner Shell (Inner Tank), ISI marked, made out of Stainless Steel Sheet 20 Gauge thick suitable for Electric Water Heater 25 Litre capacity of any Make/ Model in existing Shape & Size including Taking down/out unserviceable Inner Shell, complete all as specified and as directed.
S&F Outer Body complete with Top & Bottom Cover, Inspection Plate suitable for Electric Water Heater 25 Litre capacity of any Make/Model and applying Two Coats of Synthetic Enamelled Paint (as approved) ove a coat of Red Oxide Zinc Chrome Primer with Spray Painting Machine including Taking down/out unserviceable Outer Body, complete all as specified and as directed.
S&F PVC Connection in Inlet, 15mm bore (dia) & 450mm in length with PTMT Nuts suitable for Cold/Hot Water including Taking down/out unserviceable PVC Connection, complete all as specified and as directed.
S&F Safety Valve, ISI marked suitable for Electric Water Heater 25 Litre capacity of any Make/ Model including Taking down/out unserviceable Safety Valve, complete all as specified and as directed.
S&F Thermostate Switch with Thermal Setting 40 °C to 90 °C capacity and Relay 240 Volt AC suitable for Electric Water Heater 25/50 Litre capacity of any Make/ Model including Taking down/out unserviceable Thermostate Switch, complete all as specified and as directed.
S&F Metal Clad Top 2 Pole & Earth 20 Amp, ISI marked and connecting up including Taking down/out unserviceable Metal Clad Top, complete all as specified and as directed.
S&F Plug Top 6 Amp, 3 Pin, ISI marked and connecting up including Taking down/out unserviceable Plug Top, complete all as specified and as directed.
S&F Plug Top 16 Amp, 3 Pin, ISI marked and connecting up including Taking down/out unserviceable Plug Top, complete all as specified and as directed.
S&F PVC insulated, Flexible, Copper multi-stranded Cable, Cross-sectional area 4.0 Sqmm, 3 Core and making Electric connection to Electric Water Heater and Plug Top including Taking down/out unserviceable Cable of any description, complete all as specified and as directed.
REPAIRS/MAINT TO AIR CONDITIONERS
M&L Taking down/ Lowering Defective Split AC 1.5/2.0 TR Capacity of any Make from any Height by disconnecting all Electric Connections, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects & Repair Works involves, Repairing/Replacing of unserviceable Parts, Cleaning thoroughly Condensing Unit to achive Proper Cooling effect, Checking of Electronic Circuit of Machine, Changing of Wiring with proper size PVC insulated Copper Wires, Brazing the Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof, Re-install the Same in Original/ New Position and providing necessary Electric Connection, Testing on Completion, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Split AC 1.5/2.0 TR Capacity Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items and the Quantities are Provisional.
M&L Compressor Rotary type (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split AC 2.0 TR Capacity with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : CARRIER/ HITACHI/ KIRLOSKAR/ TECUMSEH
M&L Compressor Rotary type (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split AC 2.0 TR Capacity with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : CARRIER/ HITACHI/ KIRLOSKAR/ TECUMSEH
M&L Condensor Fan Blade Assembly, Heavy duty for Fan Motor (as per Existing One/ as approved) suitable for Split type AC 1.5/ 2.0 TR Capacity and providing necessary Connections & Testing including Taking down/out unserviceable Condensor Fan Blade Assembly, complete all as specified and as directed. MAKE : CARRIER/ FEDDERS LLOYED/ VOLTAS
M&L Indoor Motor, Single Phase, 230 Volt (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split type AC 1.5/ 2.0 TR Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Indoor Motor, complete all as specified and as directed. MAKE : AUE/ USHA or equivalent as approved by GE
M&L Outdoor Motor, Single Phase, 230 Volt (as per Existing One/ as approved) to match the Same Model & Capacity suitable for Split type AC 1.5/2.0 TR Capacity and providing necessary Connections & Testing including Taking down/ out unserviceable Condensor Fan Blade Assembly, complete all as specified and as directed. MAKE : AUE/ USHA or equivalent as approved by GE
M&L Copper Pipe 1/2" (as per Existing One/ as approved) to match the Same Model & Capacity AC with necessary Connection & Testing including Taking down/ out unserviceable Pipe, complete all as specified and as directed.
M&L Copper Pipe 5/8" and 3/8" (as per Existing One/ as approved) to match the Same Model & Capacity AC with necessary Connection& Testing including Taking down/ out unserviceable Pipe, complete all as specified and as directed.
M&L Flare Nut made out of Brass for Copper pipe 1/2"/ 3/8" (as per Existing One/ as approved) including Taking down/ out unserviceable Nut, complete all as specified and as directed.
M&L Insulation On & Around Suction and Discharge Copper Piping with 6.0mm thick Flexible Thermocool Heat Resistant duly scrapped with Sticking Tape & Testing includ-ing Taking down/ out unserviceable Insulation, complete all as specified and as directed.
M&L Power Circuit (PC) Plate (as per Existing One/ as approved) suitable for Split type AC 1.5 TR and providing necessary Connections & Testing including Taking down/out unserviceable Power Circuit, complete all as specified and as directed.
M&L Power Circuit (PC) Plate (as per Existing One/ as approved) suitable for Split type AC 2.0 TR and providing necessary Connections & Testing including Taking down/out unserviceable Power Circuit, complete all as specified and as directed.
M&L Repairs to Power Circuit (PC) Plate of Split type AC 1.5 TR, re-fixing after repaired and providing necessary Connections, complete all as specified and as directed.
M&L Repairs to Power Circuit (PC) Plate of Split type AC 2.0 TR, re-fixing after repaired and providing necessary Connections, complete all as specified and as directed.
M&L Sensor Set Dry Cool (as per Existing One/ as approved) suitable for Split type AC 1.5/2.0 TR and providing necessary Connections & Testing including Taking down/out unserviceable Sensor Set, complete all as specified and as directed.
M&L Shifting Split type AC 1.5/ 2.0 TR Capacity Outer Unit with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage Vacum Test Pressure, Testing, insisting thick Flexible Thermocool and Servicing of Indoor and Outdoor Unit, complete all as specified and as directed.
Supply & Charging Gas F-22 to Split type Air Conditioner 2.0 TR Capacity including necessary Servicing, Brazing to Stop the Leakage of required Pressure & Testing, complete all as specified and as directed.
S&F Sheet Metal Enclosure, Single Pole with a 2-Pin and Earth Plug and Socket with and including 1 No. MCB Single Pole, 20 Amp, 240 Volt and Connecting up including Taking down/out unserviceable Sheet Metal Enclosure, complete all as specified and as directed.
M&L Dismantling Voltage Stablizer of capacity 3.0 KVA having Input Rating 135-290 Volts including Transformer Copper wound, Relays Contact Point, Wiring with Replacement of Volt Meter, Repairs to Transformer, Replacement of Relays, Assembling the complete & Testing, complete all as specified and as directed.
M&L Dismantling Voltage Stablizer of capacity 5.0 KVA having Input Rating 135-290 Volts including Transformer Copper wound, Relays Contact Point, Wiring with Replacement of Volt Meter, Repairs to Transformer, Replacement of Relays, Assembling the complete & Testing, complete all as specified and as directed.
REPAIRS/MAINT TO REFRIGERATORS
M&L Opening Defective Refrigerator of any Capacity/ Make/ Model/ Type, Removal of Blockage by Flushing Out, Brazing (as required) and Making the System Fully Leakeage Proof, Replacing unserviceable Compressor & Other Parts and Re-assembling after necessary repaired and Testing, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Refrigerator Functional, even if not notified by JE/ Engineer-in-Charge, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items and the Quantities are Provisional.
M&L Compressor Unit Hermetically Sealed (as per Existing One/ as approved) suitable for Refrigerator 286/310 Litre Capacity, providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : KIRLOSKER/ TECHUMSHEH/ WHIRLPOOL
M&L Door Gasket, Magnetic type (as per Existing One/ as approved) suitable for Refrigerator 286/310 Litre Capacity including Taking down/ out unserviceable Door Gasket, complete all as specified and as complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
M&L Freeze Assembly Complete (as per Existing One/ as approved) suitable for Refrigerator 286/310 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Freeze Assembly, complete all as specified and as directed.
M&L Over Load Protector 1/6 HP Capacity (as per Existing One/ as approved) suitable for Refrigerator of any Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Over Load Protector, complete all as specified and as directed. MAKE : HITECH/ RENUTRAL/ USHA
M&L Pigmy Lamp 15 Watt, 230 Volt AC (as per Existing One/ as approved) suitable for Refrigerator of any Capacity & Testing including Taking down/ out unserviceable Lamp, complete all as specified and as directed. MAKE : CROMPTON/ PHILIPS
M&L Power Circuit Breaker (as per Existing One/ as approved) suitable for Refrigerator 286/ 310 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Power Circuit (PC) Plate, complete all as specified and as directed.
M&L Relay Open type, 1/6 HP (as per Existing One/ as approved) suitable for Refrigerator of any Capacity & Testing including Taking down/ out unserviceable Relay, complete all as specified and as directed. MAKE : HITECH/ RENUTRAL/ USHA
M&L PVC/Plastic Chilled Freezer Tray Complete (as per Existing One/ as approved) suitable for Refrigerator 286/ 310 Litre Capacity including Taking down/ out unserviceable Chilled Freezer Tray, complete all as specified and as complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
M&L PVC/ Plastic Ice Tray, Superior quality of Large size with PVC Separator Complete (as per Existing One/ as approved) suitable for Refrigerator 286/310 Litre Capacity, Providing necessary Connections including Taking down/ out unserviceable Ice Tray, complete all as specified and as directed.
M&L PVC/ Plastic Vegetable Tray Complete (as per Existing One/ as approved) suitable for Refrigerator 286/310 Litre Capacity including Taking down/ out unserviceable Vegetable Tray, complete all as specified and as directed. MAKE : KELVINATORS/ LG/ SAMSUNG
REPAIRS/MAINT TO WATER COOLERS & DEEP FREEZER
M&L Opening Defective Water Cooler of any Capacity/ Make/ Model/ Type for Checking/Repairing, Removal of Blockage by Flushing Out, Brazing (as required) Suction & Discharge Pipes for Making the System Fully Leakeage Proof, Cleaning thoroughly Cooling Coil to achive Proper Cooling effect, Replacing unserviceable Compressor & Other Parts and Re-assembling after necessary repaired & Testing, complete all as specified and as directed. NOTE :- (a) Any Minor repairs involves to make the Water Cooler Functional, even if not notified by JE/ Engineer-in-Charge, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items and the Quantities are Provisional.
M&L Capacitor 10 mfd Capacity suitable for Water Cooler 40/80 Litre or 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Capacitor, complete all as specified and as directed. MAKE : ASAIN/ KEL/ SPEED/ UNISTAR
M&L Compressor Unit Hermetically Sealed (as per Existing One/ as approved), Single Phase suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Compressor, complete all as specified and as directed. MAKE : KIRLOSKAR/ SHRIRAM/ TECHEMSHAH
M&L Fan Blade Assembly Complete, Heavy duty (as per Existing One/as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Fan Blade Assembly, complete all as specified and as directed. MAKE : SIDHWAL/ USHA/ VOLTAS
M&L Fan Motor 1/35 HP or 1/32 HP Capacity (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Fan Motor, complete all as specified and as directed. MAKE : AUE/ CROMPTON
M&L Over Load Protector 2613 (as per Existing One/ as approved) suitable for Water Cooler of any Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Over Load Protector, complete all as specified and as directed. MAKE : HITACHI/ TECHEMSHAH
M&L Starting Capacitor 40/60 mfd suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Starting Capacitor, complete all as specified and as directed. MAKE : ASAIN/ EPCOS/ SPEED/ UNISTAR
M&L Starting Kit comprising of Relay & Over Load Protector (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Starting Kit, complete all as specified and as directed. MAKE : RENUTRAL/ SHRIRAM
M&L Thermostatic Switch (as per Existing One/ as approved) suitable for Water Cooler 40/80 Litre & 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out unserviceable Thermostatic Switch, complete all as specified and as directed. MAKE : GODREJ/ INDOFOSS/ RENUTRAL
M&L Push Cock 15mm bore (dia) Brass Chromium plated, high pressure, screwed down for Socket/ Unions or GI Pipe including Taking down/ out unserviceable Push Cock, complete all as specified and as directed. MAKE : JAINSON/ NIXON or equivalent as approved by GE
M&L PVC Drain Pipe 32mm bore (dia), Heavy duty of Length 1.00 Metre with 2 Nno. Galvanized Adjustable Clamps, Providing necessary Connections including Taking down/ out unserviceable Drain Pipe, complete all as specified and as directed.
M&L PVC Float Valve Assembly 15mm bore (dia) comprising Valve Assembly, Aluminum Rod, PVC Ball, suitable Water Cooler/ Desert Cooler including Taking out/ down unserviceable Float Valve Assembly, complete all as specified and as directed.
M&L Denting, Welding to Water Cooler 40/80 Litre Capacity including applying Two Coats of Synthetic Enameled Paint (1st quality/ grade) over a Coat of red Oxide Zinc Chrome Primer with Spray Painting Machine after necessary Preparation of Surfaces including Sencil Writing MES No. with Paint, complete all as specified and as directed.
Supply & Charging Gas F-12 to Water Cooler 40/80 Litre Capacity including necessary Servicing, Brazing to Stop the Leakage of required Pressure and Testing, complete all as specified and as directed.
Supply & Charging of Refrigerant F-12 to Deep Freezer 200/400 Litre Capacity of any Make/ Type after Cleaning of Condenser Unit, Evoporator Unit, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof and Vaccuming and Testing, complete all as specified and as directed.
M&L PVC insulated, Sheathed Copper Conductor multi-stranded Cable of size 40/.0076, 3 Core (Colour White or Black) and Providing Electric Connection including Taking down/out unserviceable Cable of any description, complete all as specified and as directed.
EARTH WORKS
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Mete for Electric Post, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Removal Excavated Materials (Soil) to a distance not exc. 50 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed.
REPAIRS/MAINT OF EXTERNAL WATER SUPPLY
Taking up Galvanised Steel Tubing 25mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 32mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 50mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 80mm bore (dia) with Connections of any description, complete all as specified and as directed.
Taking up Galvanised Steel Tubing 100mm bore (dia) with Connections of any description, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 25mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 32mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 50mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 63mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 90mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
S&F Gate Valve 25mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
S&F Gate Valve 32mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
S&F Gate Valve 40mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
S&F Gate Valve 50mm bore (dia) in size for PP-R Pipe including Taking down/out Unserviceable Valve of any description, complete all as specified and as directed.
M&L Cast Iron Sluice Valve 80mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Cast Iron Sluice Valve 100mm bore (dia), Operation-cap, both sides Flanged, ISI Marked (IS:14846-2000 & Class PN 1.6) having Cast Iron Hand Wheel, Brass Spindle, Cheek Nuts and Sliding Gate and Body with Mild Steel Bolts & Nuts and Testing against Leakage including Taking out/ down Old Unserviceable Sluice Valve, complete all as specified and as directed.
M&L Construction Brick Masonry Valve Chamber of Size 60x60x60 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 2.0mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Pit, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Return-ing, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed.
M&L Construction Brick Masonry Valve Chamber of Size 100x100x100 Cm (Internal Dimension of Chamber) with Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Foundation, One Brick thick Brick Walls in Cement Mortar 1:4, Rendering 15mm thick on Brick Walls in Cement Mortar 1:4 and all Internal Surfaces except PCC Foundation Bed, Externally upto 150mm below Normal Ground Level, providing Mild Steel Valve Chamber Cover 2.0mm thick with Hinges, Handle and Locking Arrangements with Mild Steel Angle Iron Frame 40x40x5.0mm on Top of Valve Pit, Angle Iron Frame embedded in Cement Concrete 1:2:4 (20mm graded stone aggregate) 100mm thick including applying Two Coats of Black Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer after necessary preparation to all Steel Surfaces Painting, all necessary Earth Work i.e. Excavation in any type of Soil, Returning, Filling in and Removal of Surplus Soil to a distance not exc. 50.00 Metre including Demolition of Damaged Valve Chamber, complete all as specified and as directed.
M&L Cleaning Existing Water Sump 42000 LITRE capacity by carry out the following Works, complete all as specified and as directed :- (a) Dewatering the Sump by employing Tulu Pump and Man Power. (b) Removing the Sludge, Muddy and dissolved Iron Water from the Sump by employing Man Power and required Tools & Plants. (c) Scrubbing the Algae from Walls, Corners, etc. completely by using Wire Brush and Man Power. (d) Washing Walls, Bottom, Conrners, etc. using Bleaching Powder. NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.
M&L Cleaning Existing Water Sump 80000 LITRE capacity by carry out the following Works, complete all as specified and as directed :- (a) Dewatering the Sump by employing Tulu Pump and Man Power. (b) Removing the Sludge, Muddy and dissolved Iron Water from the Sump by employing Man Power and required Tools & Plants. (c) Scrubbing the Algae from Walls, Corners, etc. completely by using Wire Brush and Man Power. (d) Washing Walls, Bottom, Conrners, etc. using Bleaching Powder. NOTE : Materials viz Bamboos, Coconut String, Munj or other Equipments as required for construction of Temporary Structure on Outside of Sump will be arranged by the Contractor at his Own Arrangement & Cost and the same will be include in the Quoted Unit Rate. No Extra Amount shall be Paid separately on this account.
REPAIRS/MAINT OF PUMPS & MOTORS
M&L Repairs Monoblock Pump 3.0 HP capacity, complete all specified and as directed involving the following Works :- (a) Disconnecting all Electric & Water Supply Connections, Removing to AGE E/M Store Yard at NLP, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning Covers and Parts as required. (b) Transporting defective Pump to nearest Workshop for Repairing and carry out Repair works including Replacement of defective Unserviceable Parts. (c) Reassembling the Pump after repaired. (d) Transporting the repaired Pump to Work Site and Installation of the same, Carry out necessary Tests in presence of JE/Engineer-in-Charge to the entire satisfaction. (e) Painting Installed Pump Externally with applying Two Coats of Synthetic Enamel Paint (Shade of Paint as approved/ordered). NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to included in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Pump Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) Greasing/Oiling, etc. of Parts as as required shall be done by the Contractor without any Extra Cost to the Department. (d) Rewinding of Stator of Motor of Monoblock Pump, where invloves will be Measured and Paid separately under relevant Items.
Supply only Ball Bearing (SKF 6306) suitable for Monoblock Pump 3.0 HP capacity, complete all as specified and as directed.
Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 3.0 HP capacity, complete all as specified and as directed.
M&L Repairs Monoblock Pump 5.0 HP capacity, complete all specified and as directed involving the following Works :- (a) Disconnecting all Electric & Water Supply Connections, Removing to AGE E/M Store Yard, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning Covers and Parts as required. (b) Transporting defective Pump to nearest Workshop for Repairing and carry out Repair works including Replacement of defective Unserviceable Parts. (c) Reassembling the Pump after repaired. (d) Transporting the repaired Pump to Work Site and Installation of the same, Carry out necessary Tests in presence of JE/Engineer-in-Charge to the entire satisfaction. (e) Painting Installed Pump Externally with applying Two Coats of Synthetic Enamel Paint (Shade of Paint as approved/ordered). NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to included in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Pump Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) Greasing/Oiling, etc. of Parts as as required shall be done by the Contractor without any Extra Cost to the Department. (d) Rewinding of Stator of Motor of Monoblock Pump, where invloves will be Measured and Paid separately under relevant Items.
Supply only Ball Bearing (SKF 6306) suitable for Monoblock Pump 5.0 HP capacity, complete all as specified and as directed.
Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 5.0 HP capacity, complete all as specified and as directed.
M&L Repairs Monoblock Pump 10 HP capacity, complete all specified and as directed involving the following Works :- (a) Disconnecting all Electric & Water Supply Connections, Removing to AGE E/M Store Yard, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning Covers and Parts as required. (b) Transporting defective Pump to nearest Workshop for Repairing and carry out Repair works including Replacement of defective Unserviceable Parts. (c) Reassembling the Pump after repaired. (d) Transporting the repaired Pump to Work Site and Installation of the same, Carry out necessary Tests in presence of JE/Engineer-in-Charge to the entire satisfaction. (e) Painting Installed Pump Externally with applying Two Coats of Synthetic Enamel Paint (Shade of Paint as approved/ordered). NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to included in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Pump Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) Greasing/Oiling, etc. of Parts as as required shall be done by the Contractor without any Extra Cost to the Department. (d) Rewinding of Stator of Motor of Monoblock Pump, where invloves will be Measured and Paid separately under relevant Items.
Supply only Ball Bearing (SKF 6306) suitable for Monoblock Pump 10 HP capacity, complete all as specified and as directed.
Supply only Cast Iron Impaller CI KDS-3 suitable for Monoblock Pump 10 HP capacity, complete all as specified and as directed.
M&L Lifting of Submersible Pump & Motor Assembly 12.5 HP capacity alongwith complete Column Pipes, Submersible Cable, Safety Rope, etc. from the existing Borewell by employing Chain Pulley Block, etc., Dismantling Column Pipes by Opening Nuts, Bolts, Pump & Motor, etc, Seggregating & Stacking of Serviceable Column Pipes & Other Materials and Keep in Safe Custody for re-use, complete all as specified and as directed.
M&L Removing Submersible Pump & Motor Assembly 12.5 HP capacity to AGE E/M Store Yard at NLP, Opening/Dismantling & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Cleaning of Cover and Parts as required, Transporting defective Submersible Pump & Motor Assembly to nearest Workshop for Repairs, Repairing & Replacing of Unserviceable Parts, Reassembling Submersible Pump Motor Assembly after repaired, Transporting repaired Submersible Pump Motor Assembly back to Work Site, complete all as specified and as directed. NOTE :- (a) Spare Parts required to be replace will be Measured and Paid as "Supply only" under relevant Items. Cost of Labour Element involved for replacement of Parts will deem to included in the Quoted Unit Rate. (b) Any Minor repairs involved to make the Submersible Pump & Motor Assembly Functional, even if not notified by the Board of Officers, the same will be carry out by the Contractor without any Extra Cost to the Department. (c) The Cost of Minor Spares Parts/Items viz Nuts, Bolts, Washers, Gasket, etc. will deem to be include in the Quoted Unit Rate. (d) Rewinding of Submersible Motor, wherever invloves will be Measured and Paid separately under relevant Item.
Supply only Valve Casing /O-Ring, Valve Cup, Valve Seat, Upper & Lower Valve, Seat Retainer (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Valve Guide, Rivet, Connecting Piece, Top Chamber, Up-thrust Disc, Top Bearing (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
Supply only Neck Ring, Split Cone, Impeller, Bolts and Nuts (as per existing/ as approved) suitable for Submersible Pump 12.5 HP capacity, complete all as specified and as directed.
M&L Repair & Replacing of Submersible Pump & Motor Assembly 12.5 HP capacity Complete as required at Site to Make the Submersible Pump & Motor Assembly Serviceable and Testing, complete all as specified and as directed. NOTE : Cost of All Materials as required for Repairing of Submersible Pump & Motor Assembly to Make Serviceable will be considered in the Quoted Unit Rate.
M&L Lowering down Submersible Pump & Motor Assembly 12.5 HP capacity (after Repaired & Testing of Functionability) alongwith Column Pipes of any Size and Length, Submersible Cable, Steel Wire Rope, etc. with the help of Chain Pulley Block and Tool & Plants, Testing on Completion, complete all as specified and as directed. NOTE : Serviceable Materials viz Column Pipes, etc. will be keep in Safe Custody for Lowering . Rusted/ Unserviceable Column Pipes shall be replaced with New Pipes and the same will be Measured & Paid as 'Supply only' under approprite Item.
M&L Direct Online Starter suitable for 3.0 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPDOLJA*D
M&L Direct Online Starter suitable for 5.0 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPDOLJA*E
M&L Direct Online Starter suitable for 10 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPDOLJA*G
M&L Deluxe Automatic Star Delta Starter suitable for 12.5 HP Motor (as per existing as approved), fixing to Existing Panel Board with necessary Fixing Arrangements and providing all Electric Connections including Taking down/out Unserviceable Star Delta Starter from Panel Board, complete all as specified and as directed. MAKE : HAVELLS Cat No. IHPASDMB*
REPAIRS TO LT EXTERNAL ELECTRIFICATIONS
Dismantling unserviceable Steel Tubular Pole of any description and any size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed. NOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately.
Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed.
Taking down unserviceable Insulator of any size and any description from LT Electric Poles or from any Situations, complete all as specified and as directed.
Taking down ACSR Conductor including Line Spacers of OH Electric Lines from LT Electric Poles of any size and capacity, complete all as specified and as directed.
Dismantling Stay Assembly complete of any description, complete all as specified and as directed. NOTE : Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earth Works, Demolition of Cement Concrete, etc. will not be Measured & Paid separately.
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description including GI Pipes, Bricks, etc. from Trenches, Floors, Poles, Walls, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork, complete all as specified and as directed.
M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Work & PCC will be Measured and Paid separately under relevent Items.
M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed.
S&F Pin type Insulator 100mm height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, white, brown or green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut, complete all as specified and as directed.
S&F Insulator Shackle type, Porcelain, Vitreious, white brown or green of size 150mm High and 150mm dia including Galvanised Mild Steel Straps of Section 38x5mm, 20mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 11000 Volt, complete all as specified and as directed.
S&F Insulator Loop type, Small in size, Vitreous Porcelain, white, borwn or green with Overall Dimensions 65x90mm, Clearance of Hole 16mm, complete all as specified and as directed.
S&F ACSR Conductor of any size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed. NOTE : Size of Conductor will be as per Site requirement as Ordered.
M&L Stay Assembly complete with all Accessories such as Mild Steel Galvanised Flat Iron Stay Clamp 7/3.15 Mild Steel Galvanised Stay Wire, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 65x90mm and Clearance of Hole 16mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles, 16mm dia Mild Steel Galvanised Stay Rod and Mild Steel Galvanised Stay Plate all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed. NOTE : Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevant Items.
S&F Air Breaks Gang Operating Switch 11 KV, Triple Pole with DO Mechanically Vertical Operated, mounted on Insulator and Steel Frame with operating mechanism worked from Ground Level for current rating up to 200 Amp including Taking down unserviceable GOD, complete all as specified and as directed.
S&F LED Street Light Fitting 40 Watt Environmental Friendly, Energy Saving, New Generation, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed. MAKE : HAVELLS, CAT No. ENDURAPEARLNEOSL40WLED757PASYTOPC or equivalent in Make : BAJAJ/ CG/ PHILIPS
S&F LED Street Light Fitting 45 Watt Environmental Friendly, Energy Saving, New Generation, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed. MAKE : HAVELLS, CAT No. ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent in Make : BAJAJ/ CG/ PHILIPS
M&L Painting LT Steel Tubular Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
Supplying, Laying, Commissioning & Testing LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998 having Cross-sectional Area 10 Sqmm, 2 Core, laid in Trenches, Ducts, Pipes or on Poles, etc., complete all as specified and as directed. NOTE : Earth Works, Pipes, Concrete Cable Cover, etc. will be Measured and Paid separately under relevent Items.
Supplying, Laying, Commissioning & Testing LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998 having Cross-sectional Area 16 Sqmm, 4 Core, laid in Trenches, Ducts, Pipes or on Poles, etc., complete all as specified and as directed. NOTE : Earth Works, Pipes, Concrete Cable Cover, etc. will be Measured and Paid separately under relevent Items.
Supplying, Laying, Commissioning & Testing LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998 having Cross-sectional Area 25 Sqmm, 4 Core, laid in Trenches, Ducts, Pipes or on Poles, etc., complete all as specified and as directed. NOTE : Earth Works, Pipes, Concrete Cable Cover, etc. will be Measured and Paid separately under relevent Items.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Sub-class ‘B’ Bricks, Kiln burnt for Cable Protection Cover, complete all as specified and as directed.
REPAIRS/MAINT TO LT PANEL BOARDS & EARTHING
S&F MCCB 100 Amp 4 Pole, 26 kA, 415 Volt, 50 Hz with Outgoing & Incoming Cable Connection and connecting up including Taking down/out unserviceable MCCB, complete all as specified and as directed.
S&F MCCB 125 Amp 4 Pole, 26 kA, 415 Volt, 50 Hz with Outgoing & Incoming Cable Connection and connecting up including Taking down/out unserviceable MCCB, complete all as specified and as directed.
S&F Synthetic Insulation Mat of Size 2000x1000x10mm thick (as approved), ISI marked and suitable for 1100 Volts Grade including Taking out unserviceable Insulation Mat of any description, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Earth Works in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4(20mm graded stone aggregate) reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Earth Works in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
M&L Earthing with Copper Earth Plate Electrode 600x600x3.15mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Copper Earth Strip of size 20x3.0mm by means of Bolts, Nuts, Check nuts and Washers of Copper Strip and connected Earthing Testing Point/Bus-bar, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4(20mm graded stone aggregate) reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Earth Works in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
REPAIRS/MAINT TO DG SETS
M&L Repairs/Maint & Servicing of DG Set 30 KVA capacity of MAKE : ASHOK LAYLAND, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE :- (a) Cost of all Materials i.e. Spare Parts and Labour Elements required for Functional of DG Set will deem to be included in the Quoted Unit Rate. (b) Quantites of Spare Parts at Item No. 12.02 to 12.09 are Proisional and will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only AVR (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Cooling Fan (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Fuel Filer Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only Oil Filer Assembly (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 30 KVA capacity, complete all as specified and as directed.
M&L Repairs/Maint & Servicing of DG Set 62.5 KVA capacity of MAKE : KIRLOKAR, complete all as specified and as directed comprising with the following Works:- (a) Replacement of all Filters, Lubricating Oil. (b) Checking of Belt Tension, Battery Connections and Topping up Distilled Water (if required), External Bolts and Nuts and its Tightening, Safety Units and its Electrical Connections, Alternator Cable Connections, Engine Control Wirings (c) Carry out necessary Tappet Clearance, if required. (d) Cleaning of Fuel Lines, Inlet Air Lines and Exhaust Liner Radiator Fins. (e) Check functioning of Changing Alternator. (f) Engine Safety viz. High Water Temperature Gauge, Oil Pressure Gauge, Oil Temperature Gauge and High Speed Gauge shall be checked for their functions and repaired/replaced if required. (g) Coolant Level and Conditioning of Coolant shall be checked and refilled if required. (h) The Governor shall be Checked and Tuned for Proper Functioning. (j) Check for Leaks if any and shall be rectified. (k) The Engine shall be Run on NO LOAD or at AVAILABLE LOAD, Check any Leakage and Abnormal Noise. If any such abnormality Noticed the same shall be Diagnosed and Remedial Action shall be taken to removed the casues. NOTE :- (a) Cost of all Materials i.e. Spare Parts and Labour Elements required for Functional of DG Set will deem to be included in the Quoted Unit Rate. (b) Quantites of Spare Parts at Item No. 12.11 to 12.18 are Proisional and will be Measured & Paid as 'Supply only' under appropriate Items.
Supply only Air Filter Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Bearing for Cooling Fan and Fan Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Controler Model No. KG162 SWS (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Door Hinges with Nut & Bolts (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Fuel Filer Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Fuel Pipe (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only Oil Filer Assembly (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
Supply only V Belt (as per existing/ as approved) suitable for DG Set 62.5 KVA capacity, complete all as specified and as directed.
S&F Toggle Switch 3-way, Double Pole (as per existing/ as approved) and connected including Taking down/out unserviceable Toggle Switch, complete all as specified and as directed.
M&L Repairing & Cleaning of Diesel Tank of any Capacity with suitable Materials after disconnecting Fuel Line, Opening of all Nuts, Bolts, etc., Re-fixing the Same after Satisfactory Repairing including necessary Welding (if required), etc., complete all as specified and as directed.
Supply & Filling Coolant for Radiators as approved), complete all as specified and as directed. MAKE : KIRLOSKAR
Supply & Filling Engine Oil 20 W/ 40 Grade as approved), complete all as specified and as directed. MAKE : CASTROL CRB Plus
ms singh construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .