| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹45.8 L+₹4.7 L (11.4%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹46.5 L+₹5.3 L (12.9%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹47.0 L+₹5.8 L (14.1%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹47.0 L+₹5.9 L (14.3%)Rejected-Finance 83 5M 1 SHIV GANGA PURAM YADAVPUR ROAD UMARPUR NEEWAN PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L5 | Rejected-Finance Being L5 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
8 Nov 2021, 6:00 pmClosed
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Special repairs to OTM accommodation of at Old Cantt Allahabad
2021_MES_480116_1
8506/E8
Open Tender
Civil Works
Item Rate
180 days
Allahabad
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹92,000
Yes
9 Dec 2021
6 Oct 2021
10 Nov 2021
6 Oct 2021
8 Nov 2021
1 Nov 2021
6 Oct 2021 - 13 Oct 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store, removing rubbish off the premises, complete all as specified and directed.
Dismantling of Bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer), laid bedded and pointed in cement mortar, complete all as specified and directed.
Demolition of mud / lime concrete in roofs not exceeding 200mm thickness, including plastering and leeping not exceeding 150mm thickness (below or above ground level) and removing rubbish from site, complete all as specified and directed.
Taking down cement plaster on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water etc, including removal of rubbish off the premises, complete all as specified and directed.
Plain Cement concrete 1:2:4 type B-0 (using 12.5 mm crushed stone aggregate), as in padding concrete / levelling course in roof slabs, benching, etc, finished even and rough to receive cement mortar screed bed, complete all as specified and directed.
Non - skid Ceramic jointless coloured tiles 7 to 8 mm thick, size of tiles shall be 400mm x 400mm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile with and including provision of 15mm thick screed bed in CM 1:6, complete all as specified and directed.
Glazed ceramic coloured tiles [premium quality] as in vertical surface of walls such as skirting / dado and risers to steps, size of tile shall be 350mm x 250mm x 7 mm / 450mm x 350mm x 7mm thick, set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match the colour or shade of tiles, laid over and including provison of 10 mm thick rendering as in backing of tiles in cement mortar 1:4, complete all as specified and directed..
Non - skid Ceramic jointless coloured tiles 7 to 8 mm thick, size of tiles shall be 600mm x 600mm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile with and including provision of 15mm thick screed bed in CM 1:6, complete all as specified and directed.
Non - skid Ceramic jointless coloured tiles 7 to 8 mm thick, size of tiles shall be 600mm x 600mm, as in vertical surfaces like skirting, dado, riser to steps, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile with and including provision of 10mm thick backing coat in CM 1:4, complete all as specified and directed. NOTE:- The height of skirting shall be 100mm.
Polished kota stone slab flooring 20-25mm thick of size 600mm x 600mm finished the surface as that of granite finish, including provision of 16 to 18 mm thick 100mm wide Jaisalmer stone border, laid over and including provision of cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, including provision of 20mm thick screed bed in CM 1:4, complete all as specified and directed.
Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including provision of 10mm thick rendering as in backing coat in CM 1:4 finished fair and even to receive tiles, complete all as specified and directed.
Granite (of any type) tiles machine cut, 18 to 20mm thick, in skirting/ dado laid over 15 mm thick backing coat in CM (1:4) and jointed with grey cement slurry, and pointed with white cement with marble dust (1:2) to match the shade of granite stone including grinding and polishing, complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and directed.
Rendering 15mm thick, on fair faces of brick work or concrete surfaces in cement sand mortar 1:4 mixed with water proofing compound, finished surface even and smooth without using extra cement complete all as specified and directed. NOTE:- Water proofing compound shall be measured and paid separately as supply only under respective items of this Schedule.
Rendering 15mm thick, on fair faces of brick work or concrete surfaces in cement sand mortar 1:6, finished surface even and fair, complete all as specified and directed.
Rendering 5mm thick in CM 1:4 on concrete surfaces in ceiling, finished fair and even, complete all as specified and directed.
Cleaning the sunken floor surfaces by wire brushing, brooming down, removing rubbish/ dust and dismantling of lime concrete floor on roof terrace and removing the rubbish from site upto 50 m outside the premises and applying following: (a) One coat of Bitumen primer confirming to IS-3384-1965 @ 0.3 ltr per sqm on top of dry/ cleaned roof surface or finished cement concrete or plaster surface. (b) Applying a tack coat of hot blown bitumen 85/25 @ 1.2 kg/sqm confirming to IS-702-1998 applied over primed surface.. (c) Providing APP modified polymeric water proofing membrane having weight not less than 3 kg per sqm consisting of 3mm thick reinforced with polyster non woven fabric with a overlap of 100 mm wide side or end lap and joint sealed with flamed torched pasted over full length. (d) Again Applying a tack coat of hot blown bitumen 85/25 @ 1.2 kg/sqm confirming to IS-702-1998 for water proofing membrane. (e) Spread coarse sand @ 1.00 kg per sqm over entire bitumen surafce, complete all as specified and directed.
PCC 1:5:10 type E-2 using 40mm crushed stone aggregate as in filling up sunken floor, complete all as specified and directed.
Providing water proofing treatment over cleaned roof surface with APP modified bitumenous membrane weight not less than 3 kg per sqm comprising of the following and testing of following: (a) 10 mm thick rendering or screed bed or bedding layer in cement sand mortar 1:3 mixed with water proofing compound @ 2% by weight of cement, finished surface even and smooth without using extra cement. (b) One coat of Bitumen primer confirming to IS-3384-1965 @ 0.3 ltr per sqm. (c) Applying a tack coat of hot blown bitumen 85/25 @ 1.2 kg/sqm confirming to IS-702-1998 for water proofing membrane. (d) Providing APP modified polymeric water proofing membrane 3mm thick having weight not less than 3 kg per sqm with 100 mm wide side or end lap and joint sealed with flamed torched pasted over full length. (e) Again Applying a tack coat of hot blown bitumen 85/25 @ 1.2 kg/sqm confirming to IS-702-1998 for water proofing membrane. (f) Spread coarse sand over entire bitumen surafce, complete all as specified and directed. NOTE:- Water proofing compound shall be measured and paid separately under respective item of this Schedule.
Brick tiles, 40 mm thick laid over and including 15 mm thick screed bedding in CM 1:6 and joints grouted, flush, pointed in CM 1:3, complete all as specified and directed. NOTE:- This item shall be executed over sand spread over roof treatment with APP membrane as mentioned in Sl. No. 19.00 here-in-before.
Brick tiles, 40 mm thick laid over and including 15 mm thick screed bedding in CM 1:6 and joints grouted, flush, pointed in CM 1:3, but except brick tiles, complete all as specified and directed. NOTE:- (a) The bricks retrieved from dismantling as in Sl. item No. 2.00 here-in-before shall be used. (b) This item shall be executed over sand spread over roof treatment with APP membrane as mentioned in Sl. No. 19.00 here-in-before.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Plain cement concrete 1:3:6, type C2 (using 40mm graded stone aggregate), as in plinth protection, 75mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at the length not exceeding 3 metre and at every change of direction and filling the same with and including provisin of bitumen and sand 1:3 by weight, complete all as specified and directed.
Taking up or down galvanised steel tubing, 15 mm bore, and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down galvanised steel tubing, 20 mm bore, and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down galvanised steel tubing, 25 mm bore, and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 15mm bore of pipe, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 20mm bore of pipe, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 25mm bore of pipe, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), except tubing, 15mm bore of pipe, complete all as specified and directed. NOTE:- The quantity of GI tube retrieved from taking down as inSl. item No. 23.00 here-in-before shall be used.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), except tubing, 20mm bore of pipe, complete all as specified and directed. NOTE:- The quantity of GI tube retrieved from taking down as inSl. item No. 24.00 here-in-before shall be used.
Supply only integral water proofing compound, ISI marked, complete all as specified and directed. NOTE:- The water proofing compound shall be incorporated in the work all as per manufacturers instructions.
Rotational moulded HDPE water storage tanks (cylindrical vertical with closed top), 1000 litre capacity (ISI embossed), double layered, hoisted and fixed in position all as specified in SSR Part I, including provision of ball valve high pressure PTMT with epoxy coated aluminium rod and high density plastic ball secured for iron pipe of dia 20mm (minimum weight 210 gram), fixed in repairss, complete all as specified and directed. fixed in repairss, complete all as specified and directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, 20mm bore, fixed in repairs, complete all as specified and directed.
Chromium plated stainless steel standard size soap tray / soap dish [size 100 x 60mm], fixed to plugs with steel screws, fixed in repairs, complete all as specified and directed.
UPVC (SWR) 110 mm bore pipes single socketed ends, in any length with rubber ring joints, fixed to walls or laid in floors or trenches, fixed in repairs, complete all as specified and directed..
UPVC (SWR) bends of any radius and 110mm bore fixed to pipes in walls making good with fixed to PVC pipe joint with rubber gasket solvent, complete all as specified and directed..
UPVC (SWR) bends with access door and 110mm bore fixed to pipes in walls making good with fixed to PVC pipe joint with rubber gasket solvent, complete all as specified and directed..
UPVC (SWR) branch piece, double (double 'Y') equal or unequal, 110mm dia fixed to pipes in walls making good with fixed to PVC pipe joint with rubber gasket solvent, provided with oval access door, complete all as specifed and directed.
UPVC (SWR) reducers 110/75mm dia fixed with solvent, complete all as specifed and directed.
UPVC (SWR) junction double, (Double 'Y') equal or unequal, 110mm bore with access door fixed to PVC pipe joint with rubber gasket solvent, fixed in repairs, complete all as specified and directed..
Salt-glazed stoneware gully traps, size 150 x 150mm, square mouthed, type 'P', fixed to trench, complete all as specified and directed..
UPVC (SWR) 75 mm bore pipes single socketed ends, in any length with rubber ring joints, fixed to walls or laid in floors or trenches, fixed in repairs, complete all as specified and directed..
UPVC (SWR) bends with oval access door and of any radius of 75mm bore jointed with cement solvent or adhesive, complete all as specified and directed..
UPVC (SWR) bends, ISI marked, of any radius of 75mm bore jointed with cement solvent or adhesive, complete all as specified and directed..
UPVC (SWR) junction double, (Double 'Y') equal or unequal, 75mm bore with oval access door fixed to PVC pipe joint with rubber gasket solvent, fixed in repairs, complete all as specified and directed..
Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm dia pipe, complete all as specified and directed.
UPVC (SWR) floor trap of 75mm dia, plain with CP grating 90mm round with or without centre hole, including jointing with cement solvent or adhesive, complete all as specified and directed.
Bib taps, cast copper alloy, chromium plated, fancy type, with capstan head handle, screwed down, screwed for iron pipe or for brass ferrule for 15mm bore, fixed in repairs, complete all as specified and directed.
Stop valves, cast copper alloy, screwed down, high pressure, with capstan headed handle, screwed both ends for iron pipe or for unions and fixed but fancy type, chromium plated (concealed type), 15 mm bore, fixed in repairs, complete all as specified and directed.
Angle valve, cast copper alloy chromium plated, screwed down, high pressure, with capstan head handle, 15mm bore, screwed for iron pipe or for unions, fixed in repairs, complete all as specified and directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shank and fly-nuts, screwed for iron pipe 15mm bore, fancy type, fixed in repairss, complete all as specified and directed.
Chromium plated brass shower rose 125 mm long, fancy type with swivel joints fixed to 15mm bore pipe, fixed in repairs, complete all as specified and directed.
PVC connection 15mm size with brass fly nuts on both ends of length 600mm, fixed in repairs, complete all as specified and directed..
Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden / plastic cleats (Minimum weight 190gms), complete all as specified and directed.
Vitreous china oval type counter sunk basin, white, of size 550mm x 400mm excluding chain, plug and porcelain stopper but including bracket, chromium plated waste coupling 32 mm dia, fixed in repairs, complete all as specified and directed.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580mm x 440mm, white, with integral foot rests (excluding flushing cistern and flush pipe) and make good to match with the existing surface of floor, fixed in repairs, complete all as specified and directed.
Cast Iron P or S trap, 100 mm bore, complete all as specified and directed.
Cast Iron sanitary connection socket to fit WC outlet, 100mm dia, complete all as specified and directed.
PVC low level cistern with inlet, 10 litre capacity, with inlet float valve, handle, including bracket, PVC bend of approved make, fixed in repairs, complete all as specified and directed.
Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern, complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5sq.m each with shutters (without taking off shutters from the frames), complete all as specified and directed.
Taking down chowkhat or frame with shutter (without taking off shutters from the frame) area exceeding 1.5 sq.m and not exceeding 4.0 sq.m each and removing from site, complete all as specified and directed.
Taking down shutter of any description exceeding 1 sq.m not exceeding 2 sq.m each and removing from site, complete all as specified and directed.
Solid PVC Door Frame of size 50mm x 95mm made out of 5mm single side prelam PVC sheet & edges will be printed to match with the prelam sheet reinforced with M.S. Square tube, complete all as specified and directed. MAKE:- Syntex / Rajshree Plastic Wood Forex, Indore
Solid PVC Door Frame of size 50mm x 95mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. square tube, complete all as specified and directed. MAKE:- Syntex / Rajshree Plastic Wood Forex, Indore
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail wire gauzed i.e. panel will be of wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly, complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed.
Flush shutters 35 mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
Glazed and skeleton shutters, 35mm thick, second class hardwood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), divided into squares with plain, chamfered or rounded mitered beads for securing glass /gauge, complete all as specified in SSR Pt- I, section 8, clause 8.24(a), complete all as specified and direcetd.
Factory Made Solid PVC Moulded Cupboard Shutter, 28 mm thick (stiles), with wood free EPS design with 2mm thick Moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supplying and fixing in frame at site, complete all as specified and directed.
Steel window factory made with side hung shutter including box type hinges with steel handle, steel peg stay, complete with glazing bars, dovetailed or welded joint, fixed in repairs, complete all as specified and directed.
Steel window factory made with side hung shutter including box type hinges with steel handle, steel peg stay, complete without glazing bars, dovetailed or welded joint, fixed in repairs, complete all as specified and directed.
Steel ventilator with top hung shutter including box type hinges with steel handle, steel peg stay, dovetailed or welded joint, fixed in repairs, complete all as specifed and direcetd.
Sheet glass (pin headed or figured glass), 3 mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sq.m in each pane, complete all as specified and directed.
Sheet glass ordinary quality 3 mm thick frosted on one side and other plain sheet glass ordinary quality, glazing with oil putty or wooden beads in a square not exceeding 0.5 sq.m in each pane, complete all as specified and directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specifed and direcetd.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, fixed in repairs, complete all as specifed and direcetd.
Ordinary rat tail rod pattern door springs, mild steel, 150mm long, including roller and roller plate, fixed on door with screws, complete all as specified and directed.
Butt hinges, 100 mm long, medium weight, cold rolled mild steel with steel pin hinge and fixed with steel screws, complete all as specified and directed.
Aluminium anodised alloy handles, 150mm long extruded, cast type fixed with screws , complete all as specifeid and directed.
Aluminium anodised alloy barrel tower bolt of extruded section, 200mm long, fixed with screws complete all as specified and directed.
MS tubing of 25mm dia with PVC coating for curtain rod fancy type including fancy type PVC brackets (wall to wall or flush to wall) for securing to curtain rod, fixed in repairs, complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, length of bolt 300 mm, complete all as specified and directed.
Preparing new plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed.
Complete removal of exisitng treatment / finish on walls by scrapping with wire brushes and cleaned with water and minor wall cracks or holes shall be filled up with cement and sand mortar and applying two coats of white wash on walls, complete all as specified and directed..
Preparing new plastered surfaces of ceiling and applying two coats of white wash, complete all as specified and directed.
Preparing old plastered surfaces of ceiling and applying two coats of white wash, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coat of acrylic emulsion paint of approved shade over a coat of primer over 1.0mm thick Birla or JK wall care putty, complete all as specifed and directed.
Complete removal of exisitng treatment / finish on walls by scrapping with wire brushes and cleaned with water and minor wall cracks or holes shall be filled up with oil putty and applying two coats of Acrylic emulsion paint of approved colour over one coat of primer over 1.00mm thick Birla or JK wall care putty on wall surfaces, complete all as specified and directed..
Preparation of new plastered surfaces of walls with sand or emery paper and applying two coat of cement base paint in approved shade over one coat of primer, complete all as specifed and directed.
Preparation of old plastered surfaces of walls with sand or emery paper and applying two coat of cement base paint in approved shade, complete all as specifed and directed.
Preparation of new steel and iron surfaces over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Preparation of new wood or wood based surfaces exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Rolled mild steel sections conforming to Fe 290-0 or (Gde-E- 165), as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc, fixed in repairs, complete all as specified and directed.
Welding in repair not exceeding 2.5 cm in length and thickness of metal to be welded upto 6mm on steel doors or window at site, complete all as specified and directed.
Demolition of concrete work (un-reinforced) in ground floors and pavings including floor tiles not exeeding 15 cm thickness (below or above ground level) and removal of debris from the site, complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Brickwork with subclass B bricks, old size straight or curved on plan exceeding 6m mean radius, built in CM 1:6, complete all as specified and directed.
Brickwork with subclass B bricks, old size straight or curved on plan exceeding 6m mean radius, built in CM 1:6, except bricks, complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and directed.
Rendering 15mm thick, on fair faces of brick work or concrete surfaces in cement sand mortar 1:4, finished surface even and fair without using extra cement, complete all as specified and directed.
Dismantling of AC corrugated or semi corrugated sheet including AC ridges as in roof covering, complete all as specified and directed..
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Complete removal of exisitng treatment / finish on walls by scrapping with wire brushes and cleaned with water and minor wall cracks or holes shall be filled up with oil putty and applying two coats of Acrylic emulsion paint of approved colour over one coat of primer, complete all as specified and directed..
Preparation of new plastered surfaces of walls and applying two coat of acrylic emulsion paint in approved shade over a coat of primer, complete all as specifed and directed.
Complete removal of exisitng treatment / finish on walls by scrapper or wire brushes and cleaned with water and minor wall cracks or holes shall be filled up with oil putty and applying two coats of cement base paint with preparation of plastered surfaces, complete all as specified and directed..
Preparation of old steel and iron surfaces over 10cm width or girth and applying two coat of synthetic enamel paint, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden or metal frames fixed with putty or beads etc, complete all as specified and directed
Brass mortice lock four lever vertical type of size 75 mm with all fitings for fixing in aluminium door, fixed in repairs, complete all as specified and directed.
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty, fixed in repairs, complete all as specified an directed.
Aluminium anodised alloy barrel tower bolt of extruded section, 150 mm long, fixed with screws, fixed in repairs, complete all as specified and directed.
Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed in repairs, complete all as specified and directed.
E- board (design lake and hill) of size 605mm x 605mm x 4mm thick, white prelaminated set, embossed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped galvanised iron imposed grid with 24mm wide T-section (white powder coated); the framework shall comprises of main runner made of 0.33mm thick GS sheet and of size 24mm x 32mm x 300mm and spaced at 1200mm (maximum) centre-to-centre, hangers of GI wire 1.6 mm dia wire to be fixed by approval rawl plug level and fastener and screws etc, flush fitting of 1200mm long cross tee (double stitching) to be interlocked between main runners at 600mm centre-to-centre to form 1200mm x 1600mm modules, cross tee longer than 600mm to be supported independently, 600 x 600mm doubles to be formed by fittings 600mm long cross tee centrally between the 1200mm cross tee, perimeter wall angle shall be made out of 0.45mm thick GS sheet of size 19mm x 19mm and 300mm long of white colour, all as per manufacturers specifications, complete all as specified and directed. MAKE:- Rajshree / Polytuff / Armstrong / Everest or any other techno-commercially equivalent make as approved by GE. NOTE:- Work shall be executed by the manufacturer only, complete all as specified and directed.
Taking down copper/ aluminium point wiring of any type, size and description (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc. to match with the existing, complete all as specified and directed.
Taking down main switches, DBs, cut-outs of any type alongwith existing boards and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as directed by Engr-in-Charge, complete all as specified and directed.
Taking down carefully submain wiring of any type and size including earth wire on wooden batten / surface conduits / casing and caping etc., and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 1.5 sq.mm (nominal area) FR type multi stranded copper conductor, single core drawn in and including provision of not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories controlled by one, one way switch, including concelad pressed steel terminal box of required size not less than 1.6mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 3.0 mm thick top cover of plastic laminated sheet of required colour for mounting of switches, sockets, fan regulator etc, including 1.5 sq.mm FR type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including making chases by cutting and making good the disturbed surfaces and applying finishes to match the existing surface, complete all as specified and directed, for the following:-
One light / fan / bell / exhaust fan point controlled by one one-way 5 Amp switch
One 3 pin, 5 Amp socket outlet point on an independent board.
One 5 pin, 5 Amp socket outlet on the same board with other switches
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 2.5 sq.mm (nominal area) FR type multi stranded copper conductor, single core drawn in and including provision of not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories, for one 6 pin 15/16 Amp socket outlet on independent board, including concelad pressed steel terminal box of required size not less than 1.6mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 3.0 mm thick top cover of plastic laminated sheet of required colour for mounting of the above socket, including 2.5 sq.mm FR type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including making chases by cutting and making good the disturbed surfaces and applying finishes to match the existing surface, complete all as specified and directed.
Switch piano, flush type single pole, one way 5/6 Amp 230 volts, complete all as specified and directed.
Socket outlet, 2 in 1, 5 pin, 5/6 Amps 230 Volts, flush type, complete all as specified and directed.
Switch piano, flush type single pole, one way 15/16 Amp 230 volts, complete all as specified and directed.
Socket outlet, 2 in 1, 6 pin, 15/16 Amps 230 Volts, flush type, complete all as specified and directed.
Lamp holder, PVC / polycarbonate body with back plate / cord grip cap suitable for batten/ angle / pendent fittings, complete all as specified and directed.
Ceiling rose, single phase, PVC / polycarbonate, insulated body, three terminals, surface bakelite sheet 63.5mm dia, complete all as specified and directed.
Ceiling fan regulator flush type, electronic, rotary stepped type, AC 230 V, suitable for 1200 / 1400 mm sweep ceiling fan, complete all as specified and directed.
Sheet metal enclosure for MCB DBs SPN, 8 way, double door, vertical type, 240 V with 200 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way, complete all as specified and directed.
MCB SPN, 6 to 32 Amp, 240 Volt, conforming to 'C' curve, 10kA breaking capacity, complete all as specified and directed.
MCB SP 6 to 32 Amp, 240 Volt, conforming to 'B' curve, 10kA breaking capacity, complete all as specified and directed.
LED bulk head light fitting, 1x10W, LED 600 lumen, enclosed in polycarbonate body, weather proof, LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. MAKE:- Phillips ENDURA Model No. WT202W LED6S CW PSU S1 PC or Cat No. HEXAFT10WLED857SSY MBOPC of Havells or techno-commercially equivalent model in Crompton / Bajaj
LED wall mounted tube light fitting, 1x18W, LED 6000K, decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. Make: Havells Model No LHEXBHP7IN1W018 or techno-commercially equivalent model of Phillips / Crompton / Bajaj
Building security light lighting luminarie 25 Watt, with unique peanut optics to ensure uniform distribution, higher spacing between poles and maintenance free system for city roads and streets, 50% energy savings, IP66 Protection PC and FG cover, high impact resistance complete including LED lamps and all accessories including bracket made out of 25mm bore GI pipe (light grade), 1.20m long made to shape and fixed to existing pole or building by means of 2 Nos MS flat iron 40x6 mm clamps with suitable size bolt, nuts & washers and connecting with 3 core flexible copper wire of size 23/0.0076 from ceiling rose to existing junction box, complete all as specified and directed. MAKE:- Cat No. LR02-291-XXX-57-XX of Wipro or Cat No. BRLEP 25W LED WH of Bajaj or techno-commercially equivalent model in CG / Philips
Exhaust fan 230 Volt 50 Hz single phase AC supply, 380 mm sweep with louvers complete with metal body powder coated with protective steel bird guard on wall of building with and including provision of 3 core 1.5 sq.mm flexible cable from ceiling rose to exhaust fan including writing MES number on exhaust fan motor using synthetic enamel paint of approved tint, including making necessary holes in masonry walls and making good the disturbed surfaces to match with the existing, complete all as specified and directed. MAKE:- Model: Ventil Air-DS of Havells or techno-commercially equivalent model in Almonard / Bajaj / Usha / Khaitan.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 20mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) If earth resistance is not found satisfactory, till satisfactory test result comes, the same shall be redone by the contractor without any extra cost to department.
Sub main wiring complete with 2 runs of 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of rigid PVC conduit 20mm dia including conduit accessories and connecting terminal ends to DB's including providing 1 run of 4sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including making good disturbed surfaces to match with existing, complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4sq.mm copper earth continuity conductor and one run of PVC casing / caping shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Taking down carefully ceiling fan / exhaust fan keeping in safe custody cleaning and servicing the fan including painting with one coat of synthetic enamel paint and marking MES No. refixing in original position including replacement of three core 23/0.0076 copper conductor, complete all as specified and directed.
Taking down carefully geyser keeping in safe custody cleaning and servicing the same including painting with one coat of synthetic enamel paint and marking MES No. refixing in position including replacement of three core 23/0.0076 copper conductor, complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 to 32 Amps, C series, 10kA capacity, complete all as specified and directed.
Sheet metal enclosure for MCCB DBs TPN, 4 way, double door (acrylic), 415 V with 200 Amps rated bus bars, including provision of MCCB of 160 Amp TPN of breaking capacity 25kA with thermal magnetic release as incommer and 6 Nos MCB SP 6-32 Amp 'B' series of breaking capacity 10kA as outgoing and provision of blaking plates wherever required and IP-43 degree protection making necessary electric connections with lugs, complete all as specified and directed.
Socket outlet, 2 in 1, 3 pin, 5/6 Amps 230 Volts, flush type, complete all as specified and directed.
Socket outlet, 2 in 1, 3 pin, 15/16 Amps 230 Volts, flush type, complete all as specified and directed.
Building security light lighting luminarie 36 Watt, with unique peanut optics to ensure uniform distribution, higher spacing between poles and maintenance free system for city roads and streets, 50% energy savings, IP66 Protection PC and FG cover, high impact resistance complete including LED lamps and all accessories including bracket made out of 25mm bore GI pipe (light grade), 1.20m long made to shape and fixed to existing pole or building by means of 2 Nos MS flat iron 40x6 mm clamps with suitable size bolt, nuts & washers and connecting with 3 core flexible copper wire of size 23/0.0076 from ceiling rose to existing junction box, complete all as specified and directed. MAKE:- Cat No BRLEP36WLEDWHOY of Bajaj / Cat No. ENDURA CITYLITE PLATINUM PLUS of Havells or techno-commercially equivalent model in Philips/ Crompton
Recess Mounting decorative LED light fitting size, 600 x 600, LED 36W, high brightness SMD LED, including suitable driver connection and testing, complete all as specified and directed.
KRISHNA BAHADUR
Abhinav Builders
AMARDEEP ENTERPRISES
chauhan construction
Avion Industries
R K GUPTA AND SONS
M/S A P CONSTRUCTION
Ram Babu Bros
M/S Akhilesh Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .