| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹1.3 Cr+₹1.5 L (1.19%)Rejected-Finance | ₹1.3 Cr+₹1.5 L (1.19%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹1.3 Cr+₹7.3 L (5.73%)Rejected-Finance | ₹1.3 Cr+₹7.3 L (5.73%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹1.4 Cr+₹9.4 L (7.38%)Rejected-Finance | ₹1.4 Cr+₹9.4 L (7.38%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not having eligible category b(ii) |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
16 May 2025, 6:00 pmClosed
CWE (ARMY) SECUNDERABAD
Commander Works Engineers Mudfort, MES Office Complex Secunderabad-500 003
ADDITION / ALTERATION and SPECIAL REPAIR TO SIMULATOR BUILDINGS AND PROVISION OF 3PHASE ELECTRIC CONNECTION AND ALLIED WORKS FOR SIMULATOR BUILDING UNDER GE (NORTH) SECUNDERABAD
2025_MES_704175_1
84614
Open Tender
Civil Works
Item Rate
270 days
Secunderabad
as per NIT
7 documents required · 7 mandatory
₹1,000
GE (NORTH) SECUNDERABAD
₹2.2 L
Yes
27 Jun 2025
11 Apr 2025
23 May 2025
11 Apr 2025
16 May 2025
2 May 2025
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including similar pattern roof covering,complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an with coach screw and washer in roof, wall etc complete all as specified and as directed.
S&F Pre- painted galvaliume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an with coach screw and washer in roof, wall , ridges etc, complete all as specified and as directed.
M& L for fly ash brick work with sub class 'B' bricks straigth or curved on plain exc 6m mean radius built in CM (1:6), complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 ( using 20mm graded stone aggregate) Providing, cement concrete in roof kerbs or mud stops,rounded or chamfered on edge, complete all as specified and as directed.
M & L rendering 15mm thick on stone surfaces or otherthan fair face of brick work surface in CM 1:6 all as specified surfaces finished even and smooth without using extra cemen, complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint on wall,complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer and 3mm thick putty on walls, complete all as specified and as directed.
M & L PCC 1:4:8 type D2 ( Using 40mm graded stone aggregate) , 75 mm thick in sub base, complete all as specified and as directed.
M&L 20-25 mm thick machine cut Polished kota stone as in flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed.
M & L 18-20 mm thick Machnie cut polished kota stone as in dado/skirting set and jointed in neat cement slurry and pointed in coloured cement to match over 10mm thick rendering in cm 1:4 backing coat, complete all as specified and as directed.
M & L preparation of old painted surfaces of steel and applying one coat of synthetic enamel paint on steel surfaces over 10 cm width or girth, complete all as specified and as directed.
M&L 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as specified and as directed.
M&L for chequerred cement concrete tiles with grey cement and pigments of size 250 x 250 x 22mm thick awr set and pointed in neat cement slurry in floors over a screed bed of 15mm thick in CM 1:6,complete all as specified and as directed.
Taking down the existing unserviceable point wiring of any description, type, size of light or fan or power or two way or bell etc on TW batten or conduit including removal of batten or conduit or gutters or wooden boards or switches or sockets or regulators or light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall or ceiling to match with the existing surfaces complete all as specified and as directed.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes, complete all as specified and as directed.
Material and labour for point wiring of any length complete with stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded CONCEALED with new sunk type pressed steel terminal boxes suitable for MODULAR switches including fixing/grouting sunken/ surface as per site requirement covered with suitable modular white cover plate for suitable size for mounting of MODULAR switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed for the following :- Note: Modular coer plate with frame, Modular metal flux box and cutting chases are inclusive of unit rate quoted by the tenderer.
(a) One light/Fan/Bell point controlled by one, one way switch 5 amps, single pole.
(b) One 3 pin 5 amps switch socket out let point controlled by one switch on independent board
(c) One 3 pin 5 amps switch socket out let point controlled by one switch on same board
All as per item No. 17.00 here in before but using 2.5 square millimetre single core copper conductor cable of multistranded PVC insulated unsheathed 1100 volts grade FRLS confirming to IS-694 for 3 pin 15 amps switch socket combination point on independent board and running of 2.5 square millimetre copper conductor PVC insulated cable FRLS as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed Note: Modular coer plate with frame, Modular metal flux box and cutting chases are inclusive of unit rate quoted by the tenderer.
Supply and fix MODULAR switch 1 way 6 A, 1 Module capacity 230 volts complete all as specified and as directed.
Supply and fix MODULAR socket 5 pin 6 amps 2 MODULE, 230 Volts complete all as specified and directed.
Supply and fix MODULAR socket 6 pin 6/16 amps 2 MODULE, 230 Volts complete all as specified and as directed.
Supply and fix Switch MODULAR 1 WAY 16 amps, 230 Volts complete all as specified and as directed.
Supply and fix fan regulator, 5 stepped, electronic type, single phase, socket size complete all as specified and as directed.
Supply and fix Ceiling rose of surface Bakelite 65 X 50 mm, three terminals, AC 50 HZ, 230 Volts complete all as specified and as directed.
Supply and Fixing Triple Pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole 63 Amps MCB complete all as specified.
Supply and fix wall mounted indus plus LED batten with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1 x 20w, 230 volts, bipin holders, DIFFUSED TYPE connector block internally prewired etc with necessary mounting arrangements including all accessories with new 3 core multi stranded copper conductor of size 23/0.193 from ceiling rose to fitting and including LED Tube 20W including taking down existing unserviceable tube light fitting complete all as specified and as directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TP 63 AMP and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and as directed.
S&F sheet metal enclosure vertical type MCCB DB TPN 8 way double door with suitable rated bus bar 415 volts suitable for and including MCCB TPN as incomer with suitable rated copper bus bar with neutral link including provision for 250 Amps MCCB 25KA TPN as incomer and SP/TP MCBs as outgoing and total number of modules equal to MCCB TPN + 24 with blanking plates and fixed flush to wall and making good the disturbed surfaces etc, complete all ass specified and as directed. Note: MCB SP/TP 24ll be measured and paid seperately.
S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar of 240 Volts, double door with magnetic locking system for fixing MCB’s / isolators including taking down existing old unserviceable MCB DB complete all as specified and as directed.
Supply and fix MCB SPN 40 amps 240 volts 'C' curve suitable for fixing in MCB DB including taking down existing old unserviceable MCB complete all as specified and as directed.
Supply and fix MCB SP 6 to 32 amps 240 volts 'C' curve suitable for fixing in MCB DB including taking down existing old unserviceable MCB complete all as specified and as directed.
Material and labour for earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. NOTE: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
Material and labour for sub main wiring with Four runs of single core FRLS PVC multistranded stranded unsheathed copper conductor cable of size 6 square mm and drawing through PVC conduit of 25mm dia with accessories on surface in wall/roof along with one run of 6 square mm FRLS PVC insulated unsheathed multi stranded 1100 volts grade with copper conductor cable as earth continuity conductor connected to earth and earth dolly, connecting to main board including removing the existing wiring and making good the disturbed wall surfaces to match with the surroundings complete all as specified and directed. Note:5 runs of 6 Square mm cable and 1 run of PVC conduit with accessories shall be measured and paid as 1 unit of running metre. Note: Cutting/Chases is inclusive of unit rate quoted by the tenderer.
Material and labour for sub main wiring with two runs of single core FRLS PVC multistranded stranded unsheathed copper conductor cable of size 4 square mm and drawing through PVC conduit of 25mm dia with accessories on surface in wall/roof along with one run of 4 square mm FRLS PVC insulated unsheathed multi stranded 1100 volts grade with copper conductor cable as earth continuity conductor connected to earth and earth dolly, connecting to main board including removing the existing wiring and making good the disturbed wall surfaces to match with the surroundings complete all as specified and directed. Note:3 runs of 4 Square mm cable and 1 run of PVC conduit with accessories shall be measured and paid as 1 unit of running metre.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFMb with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note: Cutting/Chases is inclusive of unit rate quoted by the tenderer.
Supply and fixing Wall mounted fans with blades, hooks and other accessories, 230V, 450mm sweep with motor all as specified and directed.
S & F security LED Light fitting 1x35 Watt complete with Bracket made out GI pipe med grade 25mm of L Shape 1.5 Mtr long incl clamps and nuts botls etc all as specified and as directed.
Supply, errection, testing and commissioning of Transformer outdoor type capacity 250 KVA, 3 phase, 50 Hz, ONAN type, double wound with copper winding in mild steel tank as per IS-1180 (Part-I) 2014, 11KV/433 volts, Energy efficiency level-3 with offload tapping arrangement on HT side to vary secondary voltage (+) 5 % to (-)5% in step of 2.5% on HV windings of clrcuit, vector group DYN-11, mounted on suitable size PCC Plinth, inltial filling of transformer oil and making connection from 11 KV HT bushing to epoxy cable box including all undermentioned accessories complete all as specified and as directed all as per manufacturer's instruction complete :- (i) HT side terminal box - 01 No. with suitable bushings - 03 Nos (ii) LT side terminal box - 01 No with suitable bushings - 04 Nos (iii) Lifting lugs - 04 Nos (iv) Oil conservator tank with drain plug - 01 No (v) Silica Gel breather - 01 No (vi) Drain valve with plug - No (vii) Explosion vent - 1 No (viii)Temperature guage with for oil & winding - 1 No
(ix) Earthing terminals - 2 Nos (x) Air release plug - 1 No (xi) Offioad tap changer with locking facility - 1 No (xii) Oil level guage - 1 No (xiii) Rating & connection diagram plate - 1 Nos NOTE: (i) civil work/ platform deemed to be included in quoted rate executed as per manufacturer specfication. (ii) Factory Inspection: Factory inspection will be carried by any rep detail by accepting officer. Necessary arrangement will carried out by contractor with no cost benfit. (iii) Post installation the transformer commissioning Testing will be carried by SEI or rep detail by accepting officer.
Supply and install HT 11 KV out door type gang operated air break switch suitable for horizontal or vertical mounting fixed type complete with 15 insulators with operating mechanism worked from ground levelof rating upto 400 Amps complete all as specified and as directed.
Supply and fixing Lightning arrester expulsion type complete for HT 11KV with all fittings, station/transmission class, discharge capacity 10 kilo amp complete all as specified and as directed.
Steel tubular swaged poles of type 410-SP-55 (11.0mtr long) complete with cast iron base plate, finial taper plug, bolts, nuts, screws and errected in position including painting over two coats of aluminium paint over a coat of primer and marking pole number as per give patern complete all as specified and directed.
Anti climbing device, comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round to poles, to a length of 0.5 to 1.0 metre, clamped and properly secured or as ordered complete all as specified and directed. (clamps are measured saperately)
Supply, installation connecting electrically commissioning and testing in replacement of old unsv complete outdoor type, as recommended by manufacturer, Automatic Power Factor Correction(APFC) system 8 stage type intel VAr APFC Panel with heavy duty MPPH capacitors and MCCBs as incomer factory made single unit 440 volts, 50 Hz, 3 phase 100 KVAR (2No X 5 KVAR+ 3No X 10 KVAR+ 3 x 20 KVAR) including taking down old existing one and comprising with following provisions :- (a) Metallised polypropylene MPP-H capacitor bank heavy duty of rating 100 KVAR 2NoX5 KVAR+3No X 10 KVAR+ 3X20 KVAR) confirming to IS-2834, IS-13340, 3341 & IEC 931 Make :- L&T/ EPCOS/ MEHER. (b) Capacitor duty contactor of appropriate rating for capacitor switching confirming to IEC-947-4-1 and IS 13947, Make :- L&T/ C&S/BCH.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables, heavy duty, with aluminium conductor 11000 volts grade, suitable for 11Kv/11Kv (UE/E) system ISI Marked of cross sectional area 3 core 95 sqmm, including laying in trenches or fixing to poles or passing through pipe, ducts, poles or laid in road crossings and jointing, testing and commissioning complete all as specified and directed. Note: Earthwork, sand cushioning, PCC cable covers and GI pipe for cable protection will be measured and paid separately under appropriate items.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core, XLPE, armoured, Aluminium conductor cable size 70 to 120 sq mm.
Supply & Lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of following: sizes -
(a) 185 Sqmm 3.5 core
(b ) 95 Sqmm 3.5 core
(c) 35 Sqmm 3.5 core
(d) 10 Sqmm 2 core
Supply and fixing LED street light fitting 35 Watt230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and Fix Steel tubular swaged poles of type 410-SP-31 (9.0mtr long) complete with cast iron base plate, finial taper plug, bolts, nuts, screws and errected in position including painting over two coats of aluminium paint over a coat of primer and marking pole number as per give patern complete all as specified and directed.
S & F thermo plastic junction / terminal box of size with internal dimensions of 130 x 180 x 77 mm with hinged door, incl provision of 4 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixed on pole by means of clamps made out of MS flat iron of size 25 mm x 4 mm
M&L Pipe bracket for street light fitting made out of 40mm dia GI pipe, medium grade, tubing bend to shape, 1.5 m long fixed to pole wall including provn of two sets of clamps made out of flat iron of size 50x6 mm including of provn of bolts, nuts and washers complete all as specified and directed.
M&L Expulsion fuse single pole 11000 volts upto 25 amps complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m in wide and not exceeding 1.5m in depth for laying of cables / pole and getting out in the hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 m depth for laying of pipes/cables/erection of poles etc. and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
Supply and spreading clean, fine, dry river sand in trenches for cushioning of under ground cable / inside transformer yard complete all as specified and directed Note: Only punned thickness shall be measured for payment purpose.
Supply and laying un-reinforced pre-cast concrete cable covers, class HV, Type 2, flat, size 450mmx 180mm x 40mm for HT 11 KV cable protection complete all as specified and as directed.
Supplying and laying unreinforced precast concrete cable cover, class LT, type-I, flat size 250mmx150mmx40mm and laying complete all as specified and as directed.
Plain cement concrete 1:4:8, type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
Plain cement concrete type C1, 1:3:6 using 20mm graded stone aggregate in coping and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and as directed.
M.S.work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including applying two coats of aluminium paint over a coat of primer of red oxide zinc chrome complete all as specified and directed.
M&L, Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required, 32x6mm galvanised iron strip complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters in English, Hindi & Telugu figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 1100 volts, of size 20x15cm complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters in English, Hindi & Telugu figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 11000 volts, of size 25x20cm complete all as specified and directed.
M&L, Earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to GI strip 25x4mm as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed.
M&L, Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to GI wire 4mm dia as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure, complete all as specified and as directed.
Chain link MS galvanisd fencing, any size or type, complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified and as directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed.
Extra only over Item 70 for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc, complete all as specified and as directed.
M&L stone masonary (H shape) platform of size 2.5m x 2.5 m x 1.5 m in cement mortar 1:6 with PCC foundation 1:4:8 type D-2 using 20 mm graded stone aggregate, PCC 1:2:4, type B-1 using 12.5 mm graded stone aggregate, 20 cm thick coping over brick work, plastering to exposed surfaces of brick work with cement mortar 1:4, 15mm thick complete all as specified and as directed.
Galvanised iron tubing, 40mm bore light grade with all fittings fixed complete to walls, poles, ceilings or lain in floors/ trenches/ road crossings for the protection of cables all as specified and as directed.
Galvanised iron tubing, 80mm bore light grade with all fittings fixed complete to walls, poles, ceilings or lain in floors/ trenches/ road crossings for the protection of cables all as specified and as directed.
Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board Out door type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary Aluminium bus bar arrangement with insulated bus bar 600 Amps rating , 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 40x40x5mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incomming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :-(MLTP) Incoming: (a) MCCB 4 Pole, 415 V, capacity 400 Amps - 01 No
Outgoing: (a) MCCB 4 pole adjustable type, 160 Amp, 415 Volts 50 KA – 01 No (APFC PANEL) (b) MCCB 4 pole adjustable type, 160 Amp, 415 Volts 35 KA – 03 No ( Simulators and one spare) (c) MCCB 4 pole fixed type, 63 Amp, 415 Volts 25 KA – 01 (Bldg load) (d) MCB 2 pole 16-32 Amp 240 Volt- 01 No (street light load) (e) Indicating lamps (set 03 Nos) - 01 set (R,Y & B) (f) Digital panel mounted Voltmeter and ammeter flush type of size 96 X 96 mm three phase (g) Street light timer single phase with contactor of suitable capacity -01 No (h) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end termination lugs. (j) Digital panel mounted Voltmeter and ammeter flush type of size 96 X 96 mm three phase (k) CT of size 500/5 amps - set of 03
Haasith constructions (BID ID -3298130)
Sri Associates (BID ID -3298389)
SANJEEV CONSTRUCTIONS (BID ID -3292789)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .