| 1 | L1₹10.0 LQualified Make: N and M
Model: N & M & NM- Transasia & ERBA EM 200 5 B 2 1ST FLOOR OPP METRO PILLOR 484 TILAK NAGAR DELHI 110018 | WEST | DELHI | 110018 | Make: N and M
Model: N & M & NM- Transasia & ERBA EM 200 | L1 | Qualified | |
| 2 | L2₹11 L+₹1.0 L (10.1%)Qualified Make: N and M
Model: N & M & NM- Transasia & ERBA EM 200 5B 2 FIRST FLOOR TILAK NAGAR NEW DELHI WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | Make: N and M
Model: N & M & NM- Transasia & ERBA EM 200 | L2 | Qualified | |
| 3 | L3₹11.3 L+₹1.3 L (12.6%)Qualified Make: N and M
Model: N & M & NM- Transasia & ERBA EM 200 5A 18 ROOM NO A GROUND FLOOR FRONT SIDE TILAK NAGAR DELHI DELHI 110018 UDYAM DL 11 0012098 07AAKFG1385Q1ZR B R M MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110018 | Make: N and M
Model: N & M & NM- Transasia & ERBA EM 200 | L3 | Qualified | |
| 4 | Disqualified Make: ANALYTICAL
Model: ATL BG3060 ANALYTICAL HOUSE E67 E68 RAVI PARK VASNA ROAD BARODA GUJARAT 390 015 | BARODA | VADODARA | GUJARAT | 390015 | Make: ANALYTICAL
Model: ATL BG3060 | - | Disqualified | |
| 5 | Disqualified Make: OPTI CCA-TS
Model: OPTI Medical, USA, OPTI CCA-TS D 1 253 NEW KONDLI MAYUR VIHAR PHASE III EAST DELHI INDIA | Make: OPTI CCA-TS
Model: OPTI Medical, USA, OPTI CCA-TS | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
5 Nov 2018, 3:00 pmClosed
blood gas analyser MSME Exemption For Years Of Experience And Turnover Yes Blood Gas Analyser ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Complete set of details Blood Gas Analyser (BGA) System BGA is POCT (Point of Care Test) for measuring and calculating complete Blood Gas Analysis BGA is POCT (Point of Care Test) for measuring and calculating complete Blood Gas Analysis
BGA is whole blood benchtop equipment for measuring and calculating complete Blood Gas Analysis in laboratory BGA have facility for measuring; pH
pCO2
pO2
Na+ & K+ on one robust self contained platform yes * BGA also have facility to test broad range of blood gases
electrolytes and other critical Cl
iCa
Glu
Hct
Creatini ne
Lacate
HCO3
TCO2
BEecf
BEb
02SAT
iCa(N )
tHb * 1/3 chemistry test for measuring: BGA works with Cartridge(s) and/or Reagent(s): Multiple Use Cartridge for POCT Single Use Cartridge for POCT
Multiple Use Cartridge for POCT
Single use Cartridge/Reagent (for Benchtop equipment) Monitor type LCD Display Touch Screen Colour display
LCD Display Shall have Inbuilt B P (Barometer Pressure)
Inbuilt/thermal Printer
Complete menu for blood gases
Hematocrits
electrolytes and other chemistries With Inbuilt Printer With Inbuilt Printer
With Thermal Printer external Shall have facility to test BAG Parameters in single and multiple test cartridges Yes * Shall delivers realtime patient result using electrochemical sensor technology yes * Cartridge/reagent to be used can be stored mostly at room temperature between 2-30 Degree C
Automatic calibration Yes * Shall have patient Bar Code facility
Ability to run a wide range of patient panels on one system true true
false Capability to transfer patient data to LIS/HIS false true
false Certification CE- European US FDA
CE- European Weight (Kg) >20 0-5
>5-20
>20 Warranty (Year) 5 3
5 Power requirement Bench top BGA - Power Supply With UPS 30 Min Backup POCT BGA-- Battery Rechargeable
Power Supply 220 V/50 Hz AC(Both)
POCT BGA- Power Supply 220 V 50 Hz AC
POCT BGA-- 2/3 Battery Rechargeable
Bench top BGA - Power Supply With UPS 30 Min Backup * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manjesh Bharti 825317
Training Centre and School
Meru Camp
BSF 1 30
780375
GEM/2018/B/109490
blood gas analyser
30 days
Jharkhand; Hazaribagh
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| blood gas analyser MSME Exemption For Years Of Experience And Turnover Yes Blood Gas Analyser ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Complete set of details Blood Gas Analyser (BGA) System BGA is POCT (Point of Care Test) for measuring and calculating complete Blood Gas Analysis BGA is POCT (Point of Care Test) for measuring and calculating complete Blood Gas Analysis | - | - | - |
| BGA is whole blood benchtop equipment for measuring and calculating complete Blood Gas Analysis in laboratory BGA have facility for measuring; pH | - | - | - |
| pCO2 | - | - | - |
| pO2 | - | - | - |
| Na+ & K+ on one robust self contained platform yes * BGA also have facility to test broad range of blood gases | - | - | - |
| electrolytes and other critical Cl | - | - | - |
| iCa | - | - | - |
| Glu | - | - | - |
| Hct | - | - | - |
| Creatini ne | - | - | - |
| Lacate | - | - | - |
| HCO3 | - | - | - |
| TCO2 | - | - | - |
| BEecf | - | - | - |
| BEb | - | - | - |
| 02SAT | - | - | - |
| iCa(N ) | - | - | - |
| tHb * 1/3 chemistry test for measuring: BGA works with Cartridge(s) and/or Reagent(s): Multiple Use Cartridge for POCT Single Use Cartridge for POCT | - | - | - |
| Multiple Use Cartridge for POCT | - | - | - |
| Single use Cartridge/Reagent (for Benchtop equipment) Monitor type LCD Display Touch Screen Colour display | - | - | - |
| LCD Display Shall have Inbuilt B P (Barometer Pressure) | - | - | - |
| Inbuilt/thermal Printer | - | - | - |
| Complete menu for blood gases | - | - | - |
| Hematocrits | - | - | - |
| electrolytes and other chemistries With Inbuilt Printer With Inbuilt Printer | - | - | - |
| With Thermal Printer external Shall have facility to test BAG Parameters in single and multiple test cartridges Yes * Shall delivers realtime patient result using electrochemical sensor technology yes * Cartridge/reagent to be used can be stored mostly at room temperature between 2-30 Degree C | - | - | - |
| Automatic calibration Yes * Shall have patient Bar Code facility | - | - | - |
| Ability to run a wide range of patient panels on one system true true | - | - | - |
| false Capability to transfer patient data to LIS/HIS false true | - | - | - |
| false Certification CE- European US FDA | - | - | - |
| CE- European Weight (Kg) >20 0-5 | - | - | - |
| >5-20 | - | - | - |
| >20 Warranty (Year) 5 3 | - | - | - |
| 5 Power requirement Bench top BGA - Power Supply With UPS 30 Min Backup POCT BGA-- Battery Rechargeable | - | - | - |
| Power Supply 220 V/50 Hz AC(Both) | - | - | - |
| POCT BGA- Power Supply 220 V 50 Hz AC | - | - | - |
| POCT BGA-- 2/3 Battery Rechargeable | - | - | - |
| Bench top BGA - Power Supply With UPS 30 Min Backup * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manjesh Bharti 825317 | - | - | - |
| Training Centre and School | - | - | - |
| Meru Camp | - | - | - |
| BSF 1 30 | - | - | - |
Exempted
5 Nov 2018
25 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_780375.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .