Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | ₹19.7 L Quoted ₹20.2 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹21.4 L+₹1.2 L (5.93%)Rejected-AOC | ₹21.4 L+₹1.2 L (5.93%) | L2 | Rejected-AOC NOT LOWEST |
| 3 | L3₹22.8 L+₹2.6 L (12.9%)Rejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹22.8 L+₹2.6 L (12.9%) | L3 | Rejected-AOC NOT LOWEST |
| 4 | L4₹23.4 L+₹3.1 L (15.5%)Rejected-AOC | ₹23.4 L+₹3.1 L (15.5%) | L4 | Rejected-AOC NOT LOWEST |
| 5 | L5₹30.3 L+₹10.1 L (49.9%)Rejected-AOC B 17 SHRIRAM INDUSTRIAL ESTATE G D AMBEKAR ROAD WADALA MUMBAI CITY MAHARASHTRA 400031 | MUMBAI | MAHARASHTRA | 400031 | ₹30.3 L+₹10.1 L (49.9%) | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
17 Mar 2021, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI 400088
REPAIR/MAINTENANCE OF LT UG CABLE AND ALLIED WORKS AT MANKHURD AREA AND REPAIR/MAINTENANCE OF CAPACITOR PANEL, LT PANEL AND ALLIED WORKS AT MANKHURD AREA UNDER GE (NW) MANKHURD
2021_MES_422850_1
8060/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) MANKHURD
AS PER NIT AND TENDER PAGES
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹56,000
Yes
26 Mar 2021
16 Feb 2021
19 Mar 2021
16 Feb 2021
17 Mar 2021
5 Mar 2021
16 Feb 2021 - 4 Mar 2021
Amount
Notes : (i)The contractor should be in possession of valid electrical license to execute electrical works. (ii) Supervisor for execution of electrical works/ electrical component of works employed by the contractor shall possesses supervisor certificate of competency issued by concerned State Government/ Union Territory and the worker/ tradesmen for execution of electrical works/ electrical component of works shall hold necessary permit issued by concerned State Government/ Union Territory. Excavation in trenches not exc. 1.5 mtr wide and not exc.1.50 mtr depth for foundation etc or for shafts, wells, cesspits, manholes etc n.exc 10 Sqm on plan & n.exc 1.5 mtr in depth for laying of underground cable, erection of poles etc. and getting out in soft/loose soil including separating serviceable cable protection cover for re-use at site obtained during excavation complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removal of surplus soil not exc 50mtr distance and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and directed.
Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and directed. Note :- Serviceable cable cover obtained from Ser Item No 1 shall be reused.
M & L for sand cushioning by spreading in trenches fine cursh sand by gently punning down manually as in cable protection complete all as specified and directed.
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 150 Sqmm 3.5 core in trenches, along the wall including necessary connection and providing cable lugs as required including disconnection/taking down of existing unserviceable complete all as specified and directed.
All as per item No 7.00 above but 95 Sqmm 3.5 Core -do-
All as per item No 7.00 above but 70 Sqmm 3.5 Core -do-
All as per item No 7.00 above but 50 Sqmm 3.5 Core -do-
All as per item No 7.00 above but 35 Sqmm 3.5 Core -do-
All as per item No 7.00 above but 25 Sqmm 3.5 Core -do-
All as per item No 7.00 above but 16 Sqmm 4 Core -do-
All as per item No 7.00 above but 10 Sqmm 3 Core -do-
All as per item No 7.00 above but 6 Sqmm 3 Core -do-
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core up to to 50 Sqmm incl taking down existing terminal joints complete all as specified and directed.
All as per item No 16.00 above but 3.5/4 core 70 Sqmm to 150 Sqmm size -do-
All as per item No 16.00 above but 3.5/4 core 185 Sqmm to 300 Sqmm size -do-
S& F in replacement of GI pipe light grade 40 mm dia for laying in ground, along the pole, in coping, road crossing etc for cabe protection including necessary fittings , clamps for supports, etc complete all as specified and directed.
Supply and fix Power Capacitors of Rating 25 KVAR 415 Volt in repairs Naturally air cooled Double dielectric heavy duty, MPP type 440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR conforming to IS 13340 and 13341 ISI Marked complete all as specified and directed.
All as per item No 20.00 above but Power Capacitors of Rating 20 KVAR 415 Volt
All as per item No 20.00 above but Power Capacitors of Rating 15 KVAR 415 Volt
All as per item No 20.00 above but Power Capacitors of Rating 10 KVAR 415 Volt
All as per item No 20.00 above but Power Capacitors of Rating 7.5 KVAR 415 Volt
All as per item No 20.00 above but Power Capacitors of Rating 5 KVAR 415 Volt
Equipment and labour for servicing of ACB including drawing/taking out from LT Panel, cleaning the Contacts, checking the breaker accessories, replacing the burnt out control wiring, burnt fuse units, old unserviceable spring units for proper function and carrying out ratio test by applying primary injection all for LT ACB 630 Amps to 800 Amps and refixing the breaker in position and testing all as directed by Engineer in Chare at site Note : The Contractor shall brought all T & P and testing equipments.
Supply and fix in repairs power factor controller relay 8 Stage RPM 8, 415 volts, 50 cycles suitable for manual / automatic operation with indication for each stage, power factor adjustment setting knob / screw, display. Cat no -ETACONM008R Of L & T or equivalent from Conzerv / Neptune /SCHNIDER/SYNTRON/ABB/ C&S
M & L for testing of APFC panel for proper functioning in manual & auto mode, including re-wiring the burnt out wires, replacing the wiring ducts/casing Capping, fuse units and cleaning and testing complete all as specified and directed.
Supply and Fix in replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating, Conforming to Type MNX 25 & Cat No - CS94110 of L & T or Equivalent from Schnider Electric/ABB/C&S including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system complete all as specified and directed.
All as per item No 31.00 above but Contactor Three Pole 415 volts 32 Amps AC 3 Rating Conforming to Type - MNX 32 & Cat no - CS94111 of L & T or equivalent from Schnider Electric, ABB/ C&S
All as per item No 31.00 above but Contactor Three Pole 415 volts 40 Amps AC 3 RatingConforming to Type - MNX - 40 & Cat no - CS94190 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No 31.00 above but Contactor Three Pole 415 volts 50 Amps AC 3 Rating Conforming to Type -MNX - 50 & Cat no ST19001 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No 31.00 above but Contactor Three Pole 415 volts 70 Amps AC 3 Rating Conforming to Type - MNX - 70 & Cat no - ST19002 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No 31.00 above but Contactor Three Pole 415 volts 110 Amps rating Conforming to Type - MNX - 110 & Cat no - CS94137 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No 31.00 above but Contactor Three Pole 415 volts 140 Amps AC 3 Rating Conforming to Type - MNX 140 Cat no - CS94138 of L & T or equivalent from Schnider Electric/ABB/ C&S
S & F in repair MCCB 400 Amps, 35 KA Triple Pole 415 Volts including connecting up complete in existing panel with Lugs/Glands all as specified and directed.
All as per item No 38.00 above but MCCB 250 Amps, 25 kA Triple Pole 415 Volts
All as per item No 38.00 above but MCCB 200 Amps, 25 kA Triple Pole 415 Volts
All as per item No 38.00 above but MCCB 100 Amps, 25 kA Triple Pole 415 Volts
All as per item No 38.00 above but MCCB 63 Amps, 16 kA Triple Pole 415 Volts
Supply and fix in repair add on Blocks suitable for Power contactors of range 25 Amps to 140 amps (MNX 25 to MNX 140 including making addition/Alternation to existing Wiring/circuit system complete all as specified and directed. Make- L&Tor equivalent from Schnider Electric/ABB/ C&S
Supply and Fix in repairs 230 Volts push buttons complete of colour red/ green with NO/NC elements complete all as specified and directed.
S & F in repairs 230 Volts indication lamp complete(R Y B ) for mounting on LT panel complete all as specified and directed.
S & F in repair Closing coil 415 V/230 V for ACB of rating from 630 Amps to 800 Amps complete all as specified and directed.
S & F in repair Shunt Release 415 V/230 for ACB of rating from 630 Amps to 800 Amps complete all as specified and directed.
M & L for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of cable Glands, cable lugs, bus bar link, connectors, insulators, door hinges, panel door locks & scrapping of old paints & applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for provn of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 2.50 M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification complete all as specified and directed.
S&F GI strip size 25 x 4 mm all as directed including welding brazing and taking down of existing strips as required at site complete all as specified and directed.
M & L spray painting inside, outside complete to the LT panel boards outdoor type of size not exceeding 2.0 Mtr width 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface complete all as specified and directed.
All as per item No 53.00 above but with the following acessories:- (a) Copper bus bar 400 Amps for 3 phase and Neutral. (b) MCCB TPN 200 Amps 36 KA 415 Volts, 4 pole - 1 Nos as a Incommer (c) MCCB TP 100 Amps, 25 KA - 03 Nos (e) Digital VAF Meter Conforming to Cat No - WL411010OOOO of L&T - 1 Nos (h) RYB Indicator lamp - 1 Set. Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication from GE and shall be fabricated from CPRI approved manufacturer
Supply, installing, testing and commissioning of powder coated LT feeder panel cubical outdoor type (Double Door), channel mounted, compartmentalized in construction, all confirming to IS 8623 Part I 1993, CPRI approved, fabricated by enlisted make from 3 mm thick CRCA sheet & suitable size to accomadate all accessories / fittings, incommers, outgoings, bus-bars other components / parts etc. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator. The bus bars shall have copper extension links for connecting with outgoings MCCB. The cubicle shall have a bottom channel & free standing frame (Height 0.60 Mtr from GL) made of angle iron of size not less than 50 mm x 50mm x 6mm & detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front centre openable/ lockable with key. The panel shall be dust, vermin peoof and powder coated of approved thickness complete including CT's control wiring with 1.5 Sqmm copper conductor wire and consisting of the following also including taking down of old unsv panel after disconnecting exiting cable & reconnecting the cables to new panels, removing the existing 5 Nos Energy Meters & refixing the same Energy Meters in new panel and including providing PCC foundation platfrom, execavation, grouting bolts etc. complete all as specified and directed :- (a) Copper bus bar 200 Amps for 3 Pahase and Neutral - 01 Set (b) MCCB TP- 63 Amp, 415 Volts, 25 KA - 01 No (c) MCB SPN 40 Amps, 10 KA, 230 Volts, 'C' Series - 6 Nos (d) Space for Fixing 5 Nos of Single Phase Energy Meter of Capacity 40 Amps (e) RYB indicators - 01 Set (f) Digital VAF Meter Conforming to Cat No - WL411010OOOO of L&T - 1 Nos ) Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication and shall be fabricated from CPRI approved manufacturer
M&L for testing of old earthing using calibrated earth tester & submitting result to Engr -in -charge complete all as specified and directed. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted. Note : A sum of Rs 50,525.00 towards sch of credit shall be deducated to arrive the contract sum.
M/s R J TRADING CO
sapana enterprises
Radha Engineering Services
Urja Techniques India Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .