Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC BIRD LINE CALICUT POST SRI VIJAYA PURAM SOUTH ANDAMAN 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹23.9 L | L1 | Accepted-AOC Accept |
| 2 | L2₹26.8 LRejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹26.8 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹28.0 LRejected-Finance ATR MAIN ROAD GARACHARMA II OPP MAHINDRA JADWET SHOWROOM SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹28.0 L | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹28.3 LRejected-Finance | ₹28.3 L | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹28.6 LRejected-Finance ROOM NO 01 1ST FLOOR SIMA TRADING BUILDING SURVEY NO 268 GARACHARMA VILL SRI VIJAY PURAM 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹28.6 L | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | RPG AND COMPANY L3 | M/s Gurunath Construction L5 | M/s Prem Enterprise L6 | M/s K Moorthi L4 | SKV Engineering L2 | DELTA ELECTRICALS L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing & Commissioning of online, double conversion IGBT based technology UPS of capacity 06 KVA with single phase AC input voltage range 110 to 288V and out put voltage 230 V ± 1%, 50 Hz, pure sine wave with inbuilt isolation transformer necessary protection against short circuit, over load including taking down defective UPS complete all as specified and as directed.
Make: KRYKARD/ Microtek/ Luminous | 4 | Each | 1,24,800 ₹5.0 L | 1,26,100 ₹5.0 L | 1,27,000 ₹5.1 L | 1,25,000 ₹5 L | 1,25,000 ₹5 L | 1,10,000 ₹4.4 L |
| 2.00 | Disconnecting & removing existing unserviceable battery and S&F 12 V, 18 AH SMF batteries including terminal clamps, copper lead of suitable length and size including testing and commissioning all as directed.
Make: Exide/ SF/ Amaron | 4 | Each | 5,500 ₹22,000 | 5,980 ₹23,920 | 6,000 ₹24,000 | 5,800 ₹23,200 | 5,000 ₹20,000 | 4,700 ₹18,800 |
| 3.00 | Disconnecting & removing existing unserviceable battery and S&F 12 V, 42 AH SMF batteries including terminal clamps, copper lead of suitable length and size including testing and commissioning all as directed.
Make: Exide/ SF/ Amaron | 80 | Each | 12,800 ₹10.2 L | 12,980 ₹10.4 L | 13,000 ₹10.4 L | 12,900 ₹10.3 L | 12,500 ₹10 L | 10,250 ₹8.2 L |
| 4.00 | Disconnecting & removing existing unserviceable battery and S&F 12 V, 100 AH SMF batteries including terminal clamps, copper lead of suitable length and size including testing and commissioning all as directed.
Make: Exide/ SF/ Amaron | 31 | Each | 21,500 ₹6.7 L | 21,800 ₹6.8 L | 21,900 ₹6.8 L | 21,650 ₹6.7 L | 20,000 ₹6.2 L | 20,000 ₹6.2 L |
| 5.00 | Disconnecting & removing existing unserviceable battery and S&F 12V, 150 AH tubular battery including terminal clamps, copper lead of suitable length and size including testing and commissioning all as directed.
Make: Exide/ SF/ Amaron | 6 | Each | 29,500 ₹1.8 L | 29,600 ₹1.8 L | 29,800 ₹1.8 L | 29,550 ₹1.8 L | 30,000 ₹1.8 L | 27,500 ₹1.6 L |
| 6.00 | Supply & fix as in repair sheet metal enclosure of thickness 2.00 mm withIP-42 protection, 4P, 125 Amps, 415 volts, 50 Hz Bypass switch complete all as specified and as directed. | 2 | Each | 24,800 ₹49,600 | 29,300 ₹58,600 | 29,400 ₹58,800 | 24,900 ₹49,800 | 25,000 ₹50,000 | 27,500 ₹55,000 |
| 7.00 | Supply and fixing as in repair 6 way vertical type of MCCB TPN DB, double door, IP-43, IK-09, suitable for flush mounting type, powder painted with 200 Amps copper bus bar for each phase, neutral link, earth bar and Din rail ,415 Volts complete all as specified and as directed . | 1 | Each | 28,500 ₹28,500 | 29,300 ₹29,300 | 29,400 ₹29,400 | 29,000 ₹29,000 | 27,000 ₹27,000 | 28,000 ₹28,000 |
| 8.00 | Supply and fix as in repair MCCB 125 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA Thermal magnetic type, suitable for fixing in VTPN DB complete all as specified and as directed by Engineer-in-Charge.
Note :(i) MCCB should be Ics = 100 % Icu
(ii). MCCB should be adjustable O/L (0.8-1)In and S/C - (5-10)ln | 1 | Each | 17,500 ₹17,500 | 17,800 ₹17,800 | 17,900 ₹17,900 | 17,600 ₹17,600 | 15,000 ₹15,000 | 14,500 ₹14,500 |
| 9.00 | Supply & fixing as in repair MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 25 to 63 Amps complete all as specified and as directed. | 6 | Each | 1,800 ₹10,800 | 1,950 ₹11,700 | 2,000 ₹12,000 | 1,900 ₹11,400 | 1,500 ₹9,000 | 2,500 ₹15,000 |
| 10.00 | Supply and fix as in repair sheet metal enclosure of thickness 2.00 mm with IP-42 protection, 2 pole DC MCCB of rating 320 Amps, thermal magnetic type complete all as specified and as directed by Engineer-in-Charge. | 2 | Each | 42,000 ₹84,000 | 42,150 ₹84,300 | 42,200 ₹84,400 | 42,100 ₹84,200 | 35,000 ₹70,000 | 32,000 ₹64,000 |
Updated dates
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
21 Jan 2026, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
8693/E8- SPECIAL REPAIR FOR REPLACEMENT / RENEWAL OF OLD VINTAGE / DEFECTIVE UPS BATTERIES AND CONNECTED ACCESSORIES AT INHS DHANVANTARI UNDER GE MINNIE BAY SRI VIJAYA PURAM
2025_MES_745905_1
8693/E8
Open Tender
Civil Works
90 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Yes
GE, Minniebay
₹46,000
Yes
3 Mar 2026
24 Dec 2025
23 Jan 2026
24 Dec 2025
21 Jan 2026
7 Jan 2026
Supply, installation, testing & Commissioning of online, double conversion IGBT based technology UPS of capacity 06 KVA with single phase AC input voltage range 110 to 288V and out put voltage 230 V ± 1%, 50 Hz, pure sine wave with inbuilt isolation transformer necessary protection against short circuit, over load including taking down defective UPS complete all as specified and as directed. Make: KRYKARD/ Microtek/ Luminous
Disconnecting & removing existing unserviceable battery and S&F 12 V, 18 AH SMF batteries including terminal clamps, copper lead of suitable length and size including testing and commissioning all as directed. Make: Exide/ SF/ Amaron
Disconnecting & removing existing unserviceable battery and S&F 12 V, 42 AH SMF batteries including terminal clamps, copper lead of suitable length and size including testing and commissioning all as directed. Make: Exide/ SF/ Amaron
Disconnecting & removing existing unserviceable battery and S&F 12 V, 100 AH SMF batteries including terminal clamps, copper lead of suitable length and size including testing and commissioning all as directed. Make: Exide/ SF/ Amaron
Disconnecting & removing existing unserviceable battery and S&F 12V, 150 AH tubular battery including terminal clamps, copper lead of suitable length and size including testing and commissioning all as directed. Make: Exide/ SF/ Amaron
Supply & fix as in repair sheet metal enclosure of thickness 2.00 mm withIP-42 protection, 4P, 125 Amps, 415 volts, 50 Hz Bypass switch complete all as specified and as directed.
Supply and fixing as in repair 6 way vertical type of MCCB TPN DB, double door, IP-43, IK-09, suitable for flush mounting type, powder painted with 200 Amps copper bus bar for each phase, neutral link, earth bar and Din rail ,415 Volts complete all as specified and as directed .
Supply and fix as in repair MCCB 125 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA Thermal magnetic type, suitable for fixing in VTPN DB complete all as specified and as directed by Engineer-in-Charge. Note :(i) MCCB should be Ics = 100 % Icu (ii). MCCB should be adjustable O/L (0.8-1)In and S/C - (5-10)ln
Supply & fixing as in repair MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 25 to 63 Amps complete all as specified and as directed.
Supply and fix as in repair sheet metal enclosure of thickness 2.00 mm with IP-42 protection, 2 pole DC MCCB of rating 320 Amps, thermal magnetic type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix as in repair sheet metal enclosure of thickness 2.00 mm with IP-42 protection, 2 pole DC MCCB of rating 32 Amps, thermal magnetic type complete all as specified and as directed by Engineer-in-Charge.
M & L for sub-main wiring with 10 Sq.mm (nominal area) PVC unsheathed multi strandard copper conductor PVC insulated 1100 volt grade 4 runs of single core cable drawn through and including rigid PVC conduit medium grade minimum 25 mm size / casing capping as per site requirement and its accessories complete along with one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 10 Sqmm as continuous earthing wire and connecting to common earth dolly including taking down u/s wiring complete all as directed and specified. Note : Five runs of PVC copper cable and one run of PVC conduit will be measured as one RM.
M & L for XLPE insulated, PVC innersheathed, unarmoured, 25 Sqmm single core multistrand 1100 volts grade copper conductor (FRLSH quality) cable drawn through and including PVC conduit medium grade minimum 20 mm size and its accessories for fixing on wall including taking down existing u/s cable complete all as specified and as directed by Engineer in Charge.
Material and labour earthing with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead, buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to20×3mm copper strip as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including dismantling old defective earth pit. NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe,Copper earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing and dismantling old defective earthpit.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_835212.xls
BOQ • 0.26 MB
8693TENDER.pdf
Tender Documents • 0.89 MB
Download all tender documents and submit your bid