Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.4 LAdmitted-Finance BAGIDORA DIST BANSWARA | BAGIDORA | BANSWARA | RAJASTHAN | L1 | Admitted-Finance | ||
| 2 | L2₹14.9 L+₹48,321.12 (3.36%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹15.7 L+₹1.3 L (8.91%)Admitted-Finance D 804 OPP NRI COLONY JAGATPURA JAIPUR CITY SOUTH RAJASTHAN 302033 | JAIPUR | RAJASTHAN | 302033 | L3 | Admitted-Finance | ||
| 4 | L4₹16.2 L+₹1.8 L (12.2%)Admitted-Finance 54 KATCHERY ROAD DR B N VERMA ROAD AMINABAD LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L4 | Admitted-Finance |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
4 Nov 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMISSIONER MUNICIPAL COUNCIL BANSWARA
COMMISSIONER MUNICIPAL COUNCIL BANSWARA
Municipal Council Banswara SHAYMPURA PATHWAY PAR LIGHT LAGANE KA WORK
2026_DLB_604828_1
MUNICIPAL COUNCIL BANSWARA STORE 10/2026-27/01
Open Tender
Civil Works
Percentage
60 days
COMMISSIONER MUNICIPAL COUNCIL BANSWARA
Municipal Council Banswara SHAYMPURA PATHWAY PAR LIGHT LAGANE KA WORK
2 documents required · 2 mandatory
₹500
COMMISSIONER MUNICIPAL COUNCIL BANSWARA
₹32,000
Yes
6 Nov 2026
26 Oct 2026
5 Nov 2026
26 Oct 2026
4 Nov 2026
26 Oct 2026
90 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and erection of PU coated , 6 to 7 mm thick Glass / Fibre Reinforced Pole (GRP /FRP) made by CNC filament winding machine using thermoset resin polyester/epoxy resin system) having minimum 62% glass content. designed to withstand the maximum wind speed as per IS 875, and Tested for deflection not more than 15% length of pole as per ASTM D 4923, The pole should be in one piece and tapered round in shape, pole shafts shall be provided with FRP Anchor with suitable MS cated Base with provision for fixing 4 no. foundation bolts (Including cost of Foundation Bolt), The Pole shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension on Existing cement concrete foundation. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 5 Mtr. Long, Top/ Bottom OD Dia 89/141mm ± 2mm approx. With Base 250X250 X 10mm | 35 | each | 22,643 | ₹7,92,505 |
| 2 | Supply, Erection and Fixing of GRP Overhang with cap over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSr. Single arm overhang | 35 | mtr | 4,426 | ₹1,54,910 |
| 3 | Providind and Laying RCC foundation for octagonal pole with excavation of pit ,providing and laying cement concrete with foundation bolts all as per bsr item no 67.8.2 Pole Foundation for Octagonal pole from 3 Mtr. To 6 Mtr. | 35 | Nos | 5,973 | ₹2,09,055 |
| 4 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .LED Street Light fixture with Minimum lumen output 5600 lm | 35 | each | 4,249 | ₹1,48,715 |
| 5 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR10.0 Sq. mm 4 core | 1,200 | mtr | 197 | ₹2,36,400 |
| 6 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 3x 1.5 sq.mm | 500 | mtr | 65 | ₹32,500 |
| 7 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR 6 SWG G.I. ( Hot Dipped ) Wire | 200 | mtr | 28 | ₹5,600 |
| 8 | P & F of IP 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch OFF at preselected time. Switch shall have 7 day power backup withouthampering of preset time and over ride facility for maintenance purpose Suitable for 15 kw load (three phase) including contactor, MCB, cable glands, terminal block and
locking arrangement | 1 | each | 20,352 | ₹20,352 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.58 MB
BOQ_1072653.xls
BOQ • 0.26 MB
Cori.pdf
PDF • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .