Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC OPPOSITE VIPUL GAS AGENCY HOSPITAL ROAD SOLAN H P | SOLAN | SOLAN | HIMACHAL PRADESH | L1 | Accepted-AOC Accept | |
| 2 | L2₹49.9 L+₹13.8 L (38.1%)Rejected-AOC HAMIRPUR ROAD NEAR BUS STAND UNA DISTT UNA HP | UNA | HIMACHAL PRADESH | 174301 | L2 | Rejected-AOC reject | |
| 3 | L3₹45.9 L+₹9.8 L (27.0%)Rejected-AOC | L3 | Rejected-AOC reject |
Tender Value
Refer Docs
EMD Value
₹68,700
Closing Date
28 Dec 2023, 11:00 amClosed
EE Matiana
EE Jal Shakti Division Matiana
LWSS Darjolidhar in GP Kot Shilaroo Tehsil Theog and Distt. Shimla H.P. SH Replacement of existing Pumping Machinery 120HP in stage 1st and 50 HP in stage 2nd of with energy efficient IE2 High Efficiency pumping machinery
2023_HPIPH_82840_1
JS-DM-CB-7789-7829-1
Open Tender
Pumps/Motors
Item Rate
180 days
Darjolidhar
Please refer Tender documents.
2 documents required · 2 mandatory
₹800
Yes
EE Matiana
₹68,700
Yes
20 Jun 2024
19 Dec 2023
28 Dec 2023
19 Dec 2023
28 Dec 2023
19 Dec 2023
Amount
Providing energy efficient pumps of HSC- CF pumps horizontal spindle horizontal/radial split casing /end section(back pull out arragement) single/double/multistages centrifugal pump or combination of pumps, in series/parallel of recommended other approved make such as Mather and Platt/KSB//Becon weir/Kirloskar / BE/Jyoti as per BIS-1520-1980 with upto date ammendments, read with IS -9137-1978 or latest edition suitable for lifting Clear water for under mentioned characterstics with bronze impellers/priming funnels casing ring and shaft sleaves of bronze, shaft of steel grade- with cast iron casing coupled directly through a flexible coupling on a common C.I/Cast steel base plate (base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/ Squarrel cage screen protected drip proof IE2 ( High Efficiency) induction motor of standard other approved make such as Kirloksar /Crompton /Bhel /NGEF/GEC/SIEMEN/ JAYOTI/ABB suitable for operation on 415(+)/- 5% volts, 50 cycles/second, 3 phase AC electric supply.The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the opeation range of (+)10% and(-)25 % of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS 900-1972. It should include cost ofbearing nuts,bolts and pointing etc. and should meet the following requirements:- (I) Discharge (Q) 33.56 Cum/Hr Per Set. (ii) Total Dynamic Head: 529.00 Meters.(a) LWL in sump well(h) : - Meters. (b)_ Shaft level :- - Meters. © Level at discharge point : - Meters. (d) Suction lift :- 3.00 Meters.(e) Residual head:- 3.00 Meters. (f) Static head:- 475.00 Meters.(iii) Rising main (a) Length. 1570 Meters. (b) Dia :- 125 mm. (iv) Pumping hours. 8 hours. (v) Altitude of Installation above MSL - Meters. (vi) Characteristics of water (a) Temperature oC (b) Abient Temperature oC © Turbidity Clear water JTU (d) Alkalanity Mg/CA CO3 (e) Size of the solids. Mm. (f) Other. (a) Pumps 2 sets x120 HP (I) other approved make (ii) Model (iii) No.of stages (iv)Material manufactures certificate to be appended (Performance) (I)Head(H). (ii)Discharge(Q) (iii)BHP absorbed (iv)Efficiency(n) (iv)Efficiency(n) (v) NPSH(K) (b) Motors I) other approved make ii) Model iii) Motor rating (KW). iv) Speed. ( C) Coupling ] (d) Base Plate ] 2 Nos Each
Providing change over switch with HRC fuses of Kilburn/L&T/Siemens/ Crompton/Standard/Havells other approved make and having Capacity 30% extra of the Operational rating as per IS:4064-1978 with upto date ammendments immediately after the power meter of HPSEB. Change over Main switches. ((i) other approved make (ii) Type (iii) Capacity 1 Each
Providing MS .sheet,steel fabricated floor mounted closed(Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, with steel sheet of 16 gauge Panel/Switch Board (I) Drawing (ii) Layout plan 1 Each.
comprising, capable of mounting the following accessories with all internal connections:
M.C.B./Oil circuit breaker of Kilburn/L&T/MEI/GEC other approved make & of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516-1985 with upto date ammendments with. MCB. (I) other approved make (ii) Type (iii) Range iv) Capacity. 1 Each
Earth leakage circuit breaker of recommended other approved make (Kilburn/L&T/MEI/ with upto date ammendment and of suitable range which should have control box operating handle and trip/ reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. E.L.C.B. I)other approved make ii) Type (iii) Range… 1 Each
The voltage monitor relay three phase with all protection and usual indicator and electric siren against single phasing low voltage,high voltage reverse phasing,over loading and phase voltage difference as per IS:3842(latest edition). VOLTAGE MONITOR RELAY. (I) other approved make (ii)Type (iii) Range 1 Each
Power factor meter square type of standard other approved make as per relevant IS code with uptodate ammendments of suitable rating. POWER FACTOR METER (I)Type (ii) other approved make 1 Each
Frequency meter square type of standard other approved make as per relevant IS code with upto date ammendments of suitable rating. FREQUENCY METER I) Type (ii) other approved make (iii)Range. 1 Each
Bus bar chamber having three and half copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current three and half the rating of full ength for neutral phase as per IS:8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments BUS BAR CHAMBER (I) Type (ii) other approved make (iii_ Rating… 1 Set
ICTP switches with HRC fuses of L&T/Crompton/Kilburn/Siemens/standard/ Havells other approved make & of suitable capacity as per IS 4064-1978 with upto date ammendments. ICTP SWITCHES (I) Type (ii) other approved make (iii)_Capacity 2 Each.
Three phase Indicator lamps complete with toggle switches for individual motors as per IS 3452 (P-I & II) with upto date ammendments. THREE PHASE INDICATOR (I) Type (ii) other approved make (iii) Capacity 1 Set.
Capacitor of Siemens/Bhel/GEC/ L&T/ other approved make as per IS:2834-1986 with upto date ammendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to HP offered including cablesas per relevant ISI code(of Siemens/Glocter/IEC other approved make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date ammendments CAPACITOR (I)Type (ii) other approved make (iii) Range….. 2 Each
Providing suitable Oil immersed star delta on starter of MEI/Jyoti/ other approved make as per IS 8544-1979 with upto date ammendments for squirrel cage/slip ring motor mounted on pannel board with magnetic type overload release and dashpot, time lag,under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248(P-V)- 1983 with upto date ammendments. STARTER (I) Type (ii) other approved make SINGLE PHASE PREVENTOR (I) Type (ii) other approved make 2 Each
Providing Hour run meter of recommended other approved make of suitable capacity as per IS:722(Latest edition). HOUR RUN METER (I)Type (ii) other approved make (iii)Capacity 2 Each
Prov. Antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS; 6337-1971 Antivibration Pad; (1) Size (ii) other approved make (iii)Material 2 Each.
Prov. Cast iron flanged/screw type foot valves with strainer as per IS: 4098-1986 with upto date ammendments of Kirloskar/ Mechneil/Kilburn/Leader/other approved make mm dia. FOOT VALVE: I) other approved make: ii)Class iii)Test working head. iv) Material. 2 Each
Providing double flanged cast steel sluice valve of Leader/Bhel/ Kirloskar/Kilburn/GLED/Fouress/Kartar other approved make and of …mm dia. for the delivery line of pump and capable of with standing the normal seat pressure and as per BS-1414-75 with upto date ammendments SLUICE VALVE (I)other approved make (ii) Class (iii)Seat pressure (iv) Material 2 Each
Providing double flanged(Swing type) Cast steel Reflux valve of Leader/Bhel/Kirloskar/Kilburn/GLED/Fouress/Kartar other approved make and of mm dia having bye pass arrangement on the delivery line of pump and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments REFLUX VALVE(I) other approved make(ii) Class (iii)Seat pressure (iv) Material. 2 Each
Providing double flanged Cast Iron/Cast steel Reflux valve of Leader/Bhel/Kirloskar/Kilburn/GLED/Fouress/Kartar other approved make and of … mm dia having bye pass arrangement for Rising Main and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments. REFLUX VALVE (I) other approved make (ii) Class (iii)Seat pressure (iv) Material. 1 Each.
Providing 100mm dia circular dia pressure gauge of Fiebing/Bourden Prega/precision other approved make complete with all accessories such as stop cock, copper tubing etc. as per IS 3624-1987 with upto date ammendments. PRESSURE GAUGE (I)other approved make (ii)Range 2 Each
Providing 100mm dia circular dia vaccume gauge of Fiebing/ Bourden/Prega/ Precision other approved make complete with all accessories such as stop cock,copper tubing etc. as per IS 3624-1987 with upto date ammendments. VACCUME GAUGE (I)other approved make (ii)Range: 2 Each
Prov.discharge meter standard other approved make to be tiked on the rising main near the storage tank as per the directions of the Engineer-in-charge as per IS-2373-1981 with upto date ammendments. Discharge Meter:i)other approved make: ii)Type: iii) Range: 1 Each.
Installation of all the items appearing at Serial No. 1 to 13…as per the systematic drawing attached with the tender documents (Drg. No.1). Job No. 1
Providing and fixing double flanged MS/GI piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends,tees,Nut Bolt,gasket reducers/increasers with companion flanges matching with the relevant specifications of the accessores as indicated in the drawing No 2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS 1364-1983. The pipes shall be as per relevant IS code and to withstand 1.5 times total head stipulated under item No.1 The size of the various components to be as under:- (I) Suction pipe… mm dia. (ii)Delivery pipe… mm dia. (iii)Common Header mm dia. and will extended upto 5 mtrs from the outer wall of the pump house in the direction to be jointed. SUCTION PIPE (I)other approved make (ii)Grade. (iii)Thickness (iv) Pressure rating. . DELIVERY PIPE AND COMMON HEADER. (i) material. (ii)Grade (iii)Thickness (iv) Pressure rating. 1 Job.
Providing and laying copper PVC insulated armoured power cable(one cable carrying all the three phases )of suitable size and capacity to and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of Siemens//Gloster/ JEC/ICC/EICO National/Grandlay other approved make including all other accessores such as thimbles, flexible,pipes solder,nuts and bolts, cable glands etc. laid in pipes or trenches under floor. ARMOURED POWER CABLE (A)Motor side(from switch to starter and starter to motor.) (I)Size (ii)other approved make (iii)Type (iv)Capacity (v) Core. (B)SUPPLY SIDE (FROM METER OF HPSEB TO BUS BAR AND SWITCH).(I) Size (ii) other approved make (iii)Type (iv) Capacity (v)Core. 1 Job
Providing and fixing double loop earthing and copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts,charcoal and common salt,25mmx3mm copper strips/as per IS: 3043-1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc,.complete in all respect. 1 Job
STAGE-2nd
Providing energy efficient pumps of HSC- CF pumps horizontal spindle horizontal/radial split casing /end section(back pull out arragement) single/double/multistages centrifugal pump or combination of pumps, in series/parallel of recommended other approved make such as Mather and Platt/KSB//Becon weir/Kirloskar / BE/Jyoti as per BIS-1520-1980 with upto date ammendments, read with IS -9137-1978 or latest edition suitable for lifting Clear water for under mentioned characterstics with bronze impellers/priming funnels casing ring and shaft sleaves of bronze, shaft of steel grade- with cast iron casing coupled directly through a flexible coupling on a common C.I/Cast steel base plate (base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/ Squarrel cage screen protected drip proof IE2 ( High Efficiency) induction motor of standard other approved make such as Kirloksar /Crompton /Bhel /NGEF/GEC/SIEMEN/ JAYOTI/ABB suitable for operation on 415(+)/- 5% volts, 50 cycles/second,3 phase AC electric supply.The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the opeation range of (+)10% and(-)25 % of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS 900-1972. It should include cost of bearing nuts,bolts and pointing etc. and should meet the following requirements:- (I) Discharge (Q) 15.00 Cum/Hr Per Set. (ii) Total Dynamic Head: 430.00 Meters. (a) LWL in sump well(h) : - Meters. (b)_ Shaft level :- - Meters .© Level at discharge point : - Meters. (d) Suction lift :- 3.00 Meters. (e) Residual head:- 3.00 Meters. (f) Static head:- 390.00 Meters. (iii) Rising main (a) Length. 1570 Meters. (b) Dia :- 80 mm. (iv) Pumping hours. 8 hours. (v) Altitude of Installation above MSL - Meters. (vi) Characteristics of water (a) Temperature oC (b) Abient Temperature oC © Turbidity Clear water JTU (d) Alkalanity Mg/CA CO3 (e) Size of the solids. Mm. (f) Other. (a) Pumps 2 sets x50 HP (I) other approved make (ii) Model (iii) No.of stages (iv) Material manufactures certificate to be appended (Performance) (I)Head(H). (ii)Discharge(Q) (iii)BHP absorbed (iv)Efficiency(n) (v) NPSH(K) ( b) Motors I) other approved make ii) Model iii) Motor rating (KW). iv) Speed.© Coupling ] (d) Base Plate ] 2 Nos Each
Providing change over switch with HRC fuses of Kilburn/L&T/Siemens/ Crompton/Standard/Havells other approved make and having Capacity 30% extra of the Operational rating as per IS:4064-1978 with upto date ammendments immediately after the power meter of HPSEB .Change over Main switches. ((i) other approved make (ii) Type (iii) Capacity 1 Each
Providing MS .sheet,steel fabricated floor mounted closed(Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, with steel sheet of 16 gauge Panel/Switch Board (I) Drawing (ii) Layout plan 1 Each.
comprising, capable of mounting the following accessories with all internal connections:
M.C.B./Oil circuit breaker of Kilburn/L&T/MEI/GEC other approved make & of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516-1985 with upto date ammendments with .MCB. (I) other approved make (ii) Type (iii) Range iv) Capacity. 1 Each.
Earth leakage circuit breaker of recommended other approved make (Kilburn/L&T/MEI/ with upto date ammendmentand of suitable range which should have control box operating handle and trip/ reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. E.L.C.B. I)other approved make ii) Type (iii) Range… 1 Each.
The voltage monitor relay three phase with all protection and usual indicator and electric siren against single phasing low voltage,high voltage reverse phasing,over loading and phase voltage difference as per IS:3842(latest edition). VOLTAGE MONITOR RELAY. (I) other approved make (ii)Type (iii) Range 1 Each.
Power factor meter square type of standard other approved make as per relevant IS code with uptodate ammendments of suitable rating. POWER FACTOR METER (I)Type (ii) other approved make 1 Each
Frequency meter square type of standard other approved make as per relevant IS code with upto date ammendments of suitable rating. FREQUENCY METER I) Type (ii) other approved make (iii)Range. 1 Each
Bus bar chamber having three and half copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current three and half the rating of full ength for neutral phase as per IS:8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments. BUS BAR CHAMBER (I) Type (ii) other approved make (iii_ Rating… 1 Set.
ICTP switches with HRC fuses of L&T/Crompton/Kilburn/Siemens/standard/ Havells other approved make & of suitable capacity as per IS 4064-1978 with upto date ammendments. ICTP SWITCHES (I) Type (ii) other approved make (iii)_Capacity 2 Each.
Three phase Indicator lamps complete with toggle switches for individual motors as per IS 3452 (P-I & II) with upto date ammendments. THREE PHASE INDICATOR (I) Type (ii) other approved make (iii) Capacity 1 Set
Capacitor of Siemens/Bhel/GEC/ L&T/ other approved make as per IS:2834-1986 with upto date ammendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to HP offered including cablesas per relevant ISI code(of Siemens/Glocter/IEC other approved make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date ammendments. CAPACITOR (I)Type (ii) other approved make (iii) Range….. 2 Each
Providing suitable Oil immersed star delta on starter of MEI/Jyoti/ other approved make as per IS 8544-1979 with upto date ammendments for squirrel cage/slip ring motor mounted on pannel board with magnetic type overload release and dashpot, time lag,under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248(P-V)- 1983 with upto date ammendments. STARTER (I) Type (ii) other approved make SINGLE PHASE PREVENTOR (I) Type (ii) other approved make 2 Each
Providing Hour run meter of recommended other approved make of suitable capacity as per IS:722(Latest edition). HOUR RUN METER (I)Type (ii) other approved make (iii)Capacity 2 Each
Prov. Antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS; 6337-1971 Antivibration Pad; (1) Size (ii) other approved make (iii)Material 2 Each
Prov. Cast iron flanged/screw type foot valves with strainer as per IS: 4098-1986 with upto date ammendments of Kirloskar/ Mechneil/Kilburn/Leader/other approved make mm dia. FOOT VALVE: I) other approved make: ii)Class iii)Test working head. iv) Material. 2 Each
Providing double flanged cast steel sluice valve of Leader/Bhel/ Kirloskar/Kilburn/GLED/Fouress/Kartar other approved make and of …mm dia. for the delivery line of pump and capable of with standing the normal seat pressure and as per BS-1414-75 with upto date ammendments. SLUICE VALVE (I)other approved make (ii) Class (iii)Seat pressure (iv) Material 2 Each
Providing double flanged(Swing type) Cast steel Reflux valve of Leader/Bhel/Kirloskar/Kilburn/GLED/Fouress/Kartar other approved make and of mm dia having bye pass arrangement on the delivery line of pump and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments REFLUX VALVE (I) other approved make (ii) Class (iii)Seat pressure (iv) Material. 2 Each
Providing double flanged Cast Iron/Cast steel Reflux valve of Leader/Bhel/Kirloskar/Kilburn/GLED/Fouress/Kartar other approved make and of … mm dia having bye pass arrangement for Rising Main and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments REFLUX VALVE (I) other approved make (ii) Class (iii)Seat pressure (iv) Material. 1 Each
Providing 100mm dia circular dia pressure gauge of Fiebing/Bourden Prega/precision other approved make complete with all accessories such as stop cock, copper tubing etc. as per IS 3624-1987 with upto date ammendments. PRESSURE GAUGE (I)other approved make (ii)Range 2 Each
Providing 100mm dia circular dia vaccume gauge of Fiebing/ Bourden/Prega/ Precision other approved make complete with all accessories such as stop cock,copper tubing etc. as per IS 3624-1987 with upto date ammendments. VACCUME GAUGE (I)other approved make (ii)Range: 2 Each
Prov.discharge meter standard other approved make to be tiked on the rising main near the storage tank as per thedirections of the Engineer-in-charge as per IS-2373-1981 with upto date ammendments. Discharge Meter:i)other approved make: ii)Type: iii) Range: 1 Each
Installation of all the items appearing at Serial No. 1 to 13…as per the systematic drawing attached with the tender documents (Drg. No.1). 1 Job
Providing and fixing double flanged MS/GI piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends,tees,Nut Bolt,gasket reducers/increasers with companion flanges matching with the relevant specifications of the accessores as indicated in the drawing No 2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS 1364-1983. The pipes shall be as per relevant IS code and to withstand 1.5 times total head stipulated under item No.1The size of the various components to be as under:- (I) Suction pipe… mm dia. (ii)Delivery pipe… mm dia.(iii)Common Header mm dia. and will extended upto 5 mtrs from the outer wall of the pump house in the direction to be jointed.SUCTION PIPE (I)other approved make (ii)Grade.(iii)Thickness (iv) Pressure rating. DELIVERY PIPE AND COMMON HEADER. (i)material. (ii)Grade (iii)Thickness (iv) Pressure rating. 1 Job
Providing and laying copper PVC insulated armoured power cable(one cable carrying all the three phases )of suitable size and capacity to and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of Siemens//Gloster/ JEC/ICC/EICO National/Grandlay other approved make including all otheraccessores such as thimbles, flexible,pipes solder,nuts and bolts, cable glands etc. laid in pipes or trenches under floor. ARMOURED POWER CABLE (A)Motor side(from switch to starter and starter to motor.) (I)Size (ii)other approved make (iii)Type (iv)Capacity ( v) Core. (B)SUPPLY SIDE (FROM METER OF HPSEB TO BUS BAR AND SWITCH). (I) Size (ii) other approved make(iii)Type(iv) Capacity (iv)Core. 1 Job
Providing and fixing double loop earthing and copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts,charcoal and common salt,25mmx3mm copper strips/as per IS: 3043-1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc,.complete in all respect. 1 Job
Thakur Traders
SS ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .