| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹16.6 L+₹50,910.65 (3.17%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹18.0 L+₹1.9 L (11.9%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹18.5 L+₹2.5 L (15.5%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹20.9 L+₹4.9 L (30.3%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹29.7 L
EMD Value
₹59,400
Closing Date
27 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE U ELECTRIC SUPPLY
GE U ELECTRIC SUPPLY,Delhi Cantt
REPAIR REPLACEMENT TO FAULTYDAMAGED HTLT CABLES ALONG WITH CONNECTED WORKS FOR SFC, CGDA,NIDEM,OTM I,II,III, YOGINDER VIHAR, BANA SINGH, 180 QTR, UPPER SHANKAR VIHAR, 35 INF BDE, TARAPUR ENCLAVE IN THE AREA OF AGE U ELECT SUPPLY NO III UNDER GE U E
2021_MES_458416_3
GE ELECT/D-45/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE U ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹59,400
Yes
2 Nov 2021
7 Oct 2021
29 Oct 2021
8 Oct 2021
27 Oct 2021
15 Oct 2021
60 days
Amount
Material and labour for excavation on any type of soil / PCC/ Road cutting for laying of GI pipes / HDPE pipe of any length and refilling with PCC of 1:2:4 with 20 mm aggregate complete all as specified and directed.
Supply and Laying of GI pipe of 150 mm dia as new provision under re routing complete all as specified and directed
Supply and Laying of GI pipe of 80 mm dia as new provision under re routing complete all as specified and directed
Supply and Laying of GI pipe of 50 mm dia as new provision under re routing complete all as specified and directed.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed.
Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Excavation and earth work will be measured and paid for seperately under respective items of schedule. (c) PCC cable route indicator shall be paid separately. (d)Fault to the contractor wiil be intimated vide phone/e-mail /whatsapp.The Contrator has to rectify the fault within 12 Hrs ,failure of the contractor to attend the fault beyond 12 Hrs , a penalty of Rs. 1000/Hrs will be recovered , fault will be retified by the other contractor /vendor under Risk & Cost by deducting the rectification cost with penalty from the work done.
Labour and transport for Laying only in assorted piece/ Sizes of 10 to 15 mtr length towards cable faults/ joint replacement /insulation break down for making straight through joints were cable loops are not available towards rectification of cable faults, laying, jointing and testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of the following cable sizes,11 KV grade (earth) for 11 KV (E) system, laid in trenches/ ducts /encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed. Note : Rate Quoted shall include the cost of transportation of cable from stores/ to site of work within the delhi cantt area. Note :- The HT cable shall be issued under schedule 'B'. free for laying only
3 core 300 Sq mm
3 core 240 Sq mm
3 core 185 Sq mm
3 core 120 Sq mm
Material & Labour for complete Jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm.
(a) Against joint failures.
(b) Against breakdown /damages.
Material & Labour for complete Jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 120 to 185 Sqmm.
(a) Against joint failures.
(b) Against breakdown /damages.
Material & Labour for complete Jointing and testing, indoor end termination heat shrinkable type joint , suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm against Joint Failures complete all as specified and directed.
All as per srl item No 09 here -in-before but size of 3 core,120 to185 sqmm.
Material and Labour for complete jointing and testing,outdoor end termination heat shrinkable type joint , suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 Sqmm against joint Failures complete all as specified and direcetd.
All as per srl item No 11 here -in-before but size of 3 core,120 to 185 sqmm.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 V LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Excavation and earth work will be measured and paid for seperately under respective items of schedule. (c) PCC cable route indicator shall be paid separately. (d) Fault to the contractor wiil be intimated vide phone/e-mail /whatsapp.The Contrator has to rectify the fault within 12 Hrs ,failure of the contractor to attend the fault beyond 12 Hrs , a penalty of Rs. 1000/Hrs will be recovered , fault will be retified by the other contractor /vendor under Risk & Cost by deducting the rectification cost with penalty from the work done.
Labour and transport for laying only LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, in assorted piece/ Sizes of 10 to 15 mtr length towards cable faults/ joint replacement /insulation break down for making straight through joints were cable loops are not available towards rectification of cable faults,and of complete lengths as required for laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete of size 240 to 300 Sqmm 3.5 core. complete all as specified and directed. Note : Rate Quoted shall include the cost of transportation of cable from stores/ to site of work within the delhi cantt area. and cost of removal of damaged lengths Note for item no 14 to 19 :- The LT cable shall be issued under schedule 'B' for laying only
Against Re Routing / diversion from residential buildings and restricted area / Cable insulation Failure of break down for making straight through joint
Against the damaged portion / length
All as per srl item No 14 here -in-before but size of 3.5 core,150 to 185 sqmm.
Against Re Routing / diversion from residential buildings and restricted area / Cable insulation Failure of break down for making straight through joint
Against the damaged portion / length
All as per srl item No 14 here -in-before but size of 3.5 core, 95 to 120 sqmm.
Against Re Routing / diversion from residential buildings and restricted area / Cable insulation Failure of break down for making straight through joint
Against the damaged portion / length
All as per srl item No 14 here -in-before but size of 3.5 core, 50-70 sqmm.
Against Re Routing / diversion from residential buildings and restricted area / Cable insulation Failure of break down for making straight through joint
Against the damaged portion / length
All as per srl item No 14 here -in-before but size of 3.5/4 core, 25 sqmm to 35 Sqmm
Against Re Routing / diversion from residential buildings and restricted area / Cable insulation Failure of break down for making straight through joint
Against the damaged portion / length
All as per srl item No 14 here -in-before but size of 2/3.5/ 4 core,10 sqmm to 16 Sqmm
Against Re Routing / diversion from residential buildings and restricted area / Cable insulation Failure of break down for making straight through joint
Against the damaged portion / length
Material and Labour for jointing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade of size 16 to 35 Sqmm x 3.5 / 4 core complete all as directed.
(a) Against joint failures.
(b) Against breakdown /damages.
All as per srl item No 20 here -in-before but size of 50 to 70 Sqmm x 3.5 core
(a) Against joint failures.
(b) Against breakdown /damages.
All as per srl item No 20 here -in-before but size of 120 to 185 Sqmm x 3.5 core
(a) Against joint failures.
(b) Against breakdown /damages.
All as per srl item No 20 here -in-before but size of 240 to 300 Sqmm x 3.5 core
(a) Against joint failures.
(b) Against breakdown /damages.
Dismantling/ taking down 11 kv load break switch outdoor type and supplying , installation, testing and commissioning of 11 KV, 630 Amps having short circuit capacity 20kA/3-sec, Outdoor (IP54), RMU (Ring main unit) 2-way comprising of 01 Nos motorized operated Load Break Switch and 01 Nos 630 Amp Fixed-Type motorized spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled, robotically welded stainless steel 304 (Non Ferrite Non Megnetic Grade) tank with min. thickness 3+0.5 mm, IP 67 Degree of Protection , internal-arc classified 20kA/1sec, on-site-repairable with site replacable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have padlockable double-door access with anti-theft higes, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit alongwith Bus-connected, fixed-type Auxiliary transformer shall include the following along with all necessary accessories and fittings as required at site.
(A) 01 Nos. Incoming Load Break Switch module each consisting of following accessories :- (i) Each switching-unit is designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch. (ii) 11kV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 20kA/3-sec, Making Capacity - 50kAp -01 No (iii) Auxiliary contacts - 1NO + 1NC-01 No (iv) Spring-assisted snap-action motorized mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 300 Sqmm , 3 Core , XLPE AL cable termination in live-condition. Each Set of 03 (vi) Right angle boots (push on type)-Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom , front with Interlocking mechanism including earth switch -01 No (viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set (ix) Fault Passage Indicator - It is to be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault-01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No.
(B) 01 Nos. Outgoing VCB module each consisting of following accessories :- (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch.The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 11kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 20kA/3-sec, Making Capacity - 50kAp-01 No (iii) Aux. contacts - 1NO+1NC-01 No (iv) Stored-energy motorized high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow handle-less and un-inhibited operation -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 185 Sqmm , 3 Core, XLPE AL cable termination in live-condition. Each Set of 3 (vi) Right angle boots (push on type)-Each set of 3 (vii) 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also.Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol-01 No (viii) Associated ring-core cast-resin insulated CTs 100/1 Amp , 2.5 VA, 10P10 for protection - Each Set of 3 (ix) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No (x) Capacitive voltage indication fixed type system as per IEC61243 with LED -01 No (xi) Push button for breaker trip (xii) Shunt trip coil 24V DC - 01 (xiii) ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01. (xiv) Emergency Trip Push Button - 01.
(C) 01 No. Bus-connected, fixed-type Auxiliary transformer with floor-mounted compartment of matching height and depth, positioned along-side RMU to provide required aux. supply and metering consisting of following accessories :- (i) 1-Ph (11kV/rt3):230VAC, 500VA Auxiliary transformer-01 No (ii) 2x12 Volt DC battery-01 Set (iii) Battery charger-01 No (iv) HRC fuse-links for primary side isolation and AC/DC MCBs for secondary isolation-01 Set (v) Voltmeter & RYB LED Indications to confirm AC/DC supply availability-01 Set (vi) Anti-condensation space-heater-01 No (vii) CFL lamp for illumination and 3-pin socket with switch -01 No
Note:- (i) It is preferable to have all feeder-switches inside single stainless steel compartment with incomer feeders at the extremities to prevent chances of failure due to plug-in coupling arrangement. (ii) Necessay interclocking arrangement shall be provided for safety and operations including two plate Earthings of strip sizes 32x4mm. (iii) Drawing of the RMU provided by the contractor must include the drawing of the foundation and foundation of RMU to be included in the quoted rate complete all as required at site. (iv) The cost of PCC works for placing RMU on plinth is deemed to be included in the cost, height of the plinth should not be less than 0.45 mtr from ground level.
Material and labour for bore earthing 150 mm dia, depth 30 mtr below ground level using earth electrode 50 mm dia GI pipe medium grade duly drilled hole of 12 mm dia 15 cm C/C on both side of the pipe including lowering in bore well upto the depth of 29 mtr and one mtr above the gound level the pipe electrode should be filled around commercial salt charcoal dust/ Breeze and magnesium phophate of 30 CM layer each upto the full length of pipe. The bore well should have 06 mtr of length 150 mm dia MS pipe for protection of bore well. The GI strip 50X6 mm 20 mtr welded on earth electrode, GI pipe 50 mm dia and GI strip 15 mtr from the bore well to test point. Note :- (a) Excavation and Earth work for drilling hole for electode/ pipe in Hard rocky soil should be carried out using the Rig / compressor only (b) The rate of GI strip as specified shall deemed to be included from earth pit to test point up to 20 mtr.
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out for laying of electric power cable and getting out all as specified and directed by engineer –in-charge.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 50 mtr above the starting point .
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by engr –in-charge
Supply &Laying sub class B bricks having minimum compressive strenth 75 Kg/sqm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per Srl item No 30 here in before but using old bricks obtained under item No 26.
Supply and lay in replacement unreinforced precast concrete cable covers class HV Type -1 with peak size 300 x 180 x 40 mm. compete all as specified and directed
All as per srl item No 32 here-in-before but using old tiles obtained under srl item No 26.
Labour and transport for Laying only towards cable faults/ joint replacement /insulation break down for making straight through joints were cable loops are not available/ Under the Metro foundations / Roads towards rectification of cable faults, laying, jointing and testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of the cable of 240 Sqmm size,11 KV grade (earth) for 11 KV (E) system, laid in trenches/ ducts /encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed. Note : Rate Quoted shall include the cost of transportation of cable from stores/ to site of work within the delhi cantt area. (ii) Jointing of cable through straight through shall be measured under relevant Item (iii) HT Cable shall be issued under Schedule 'B' Free for Laying
M&L for boring of holes under road/pavement/hard standing by trenchless technology using ultra sound technique and necessary machine including material and labour for HDPE pipe of 160 mm dia suitable for 04 Kg/cm working pressure. Wall thickness of pipe not less than 6.5 mm. for 11KV Cable Note: (i) The contractor will be responsible for taking permission from appropriate authority i.e. NHAI / IGL or other Units , if needed, for above said work. (ii) Depth of Trench Less shall not less than 2 mtr from ground level unless other wise specifed due to site requirement and contractor has to maintain the depth of trenchless up to 4 mts from ground level if required as per site conditions all rates quoted shall be demeed to be included to maintain the Trench less depts as directed during exection to avoid damages to the existing services (iii) The cost quoted is deemed to be inculded for repiars / rectification for damages done to the existing elecrtical / comminication and water supply system / Sewage System during execution of work
Note: the unit rate quoted shall be deemed to include the cost of earth work of any type of soil including dismantilling of PCC foundation of unserviceable pole and with new RCC foundation 1:2:4 type B-1 approx Size 0.6m x 0.6 m x 1.0 mtr depth for new pole including supply and errection of EN grade foundation Bolt M 20* 600 mm long complete, Foundation to be made as per the manufactures specification and Approved by the Accepting Officer. (i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
KISHORE ENTERPRISES
M P TYAGI ENGINEERS AND CONTRACTORS
MV Engineers And Contractors
Ridhi engineers and builders
Vijay Electricals
mayur enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .