Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹11.1 L
EMD Value
₹22,125
Closing Date
9 Mar 2021, 4:00 pmClosed
EXECUTIVE ENGINEER CIVIL STORES NDMC
OFFICE OF THE EXECUTIVE ENGINEER CIVIL STORES NDMC ROOM NO 224 SBS PLACE NEW DELHI
9 B Suspense Stock during 2020 21 SH Supply and Stacking of GT Cover with Frame and GT Cover only in NDMC Civil Store
2021_NDMC_200688_1
22/EE(Store)/2020-21
Open Tender
Supply of Materials
Supply
60 days
Civil Store Division NDMC New Delhi
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹22,125
15 Mar 2021
1 Mar 2021
9 Mar 2021
1 Mar 2021
9 Mar 2021
1 Mar 2021
Amount
Supplying and Stacking of precast steel fibre reinforced cement concrete gully grating horizontal of the following sizes and specification at site including all leads as per direction of Engineer-in-Charge.
SFRC Rectangular GT Cover with Frame for 450mm x 500 mm size clear opening in frame.
SFRC Circular GT Cover with Frame for 560mm dia clear opening in frame.
GT Cover only of rectangular shape 520mm x 560mm and 70mm thick.
GT Cover only of circular shape 660mm dia and 70mm thick.
Conditions:- 1. The material shall be supplied at any NDMC stores as per instruction of Engineer-in-Charge. 2. The quoted rates shall be net, inclusive of all taxes i.e. GST, cartage etc. and nothing extra shall be paid over the quoted rates in this account to the contractor. 3. The material shall be supplied proportionate to the time of completion of supply and as per the directions of the Engineer-in-Charge. 4. All other conditions of G.T. Cover & Frame like thickness, tolerances, sampling, concreting, reinforcement etc. will be governed by as in the case of equivalent nearest size manhole cover & frame as per IS:12592. 5. Protective mild steel flat sheet of minimum 2mm thickness around the periphery of the cover and 25mm x 3mm mild steel flat as part of the frame and shall be given suitable treatment of anti-corrosive paint or coating as described in IS : 12592. 6. When tested after ultimate load as per method described in IS:12592 for manhole cover with frame, the grating cover with frame shall bear a non fracture load of 5.00 MT for 20 seconds. Testing to be carried out from laboratory approved by Engineer-in-Charge. The number and method of sampling shall confirm to IS: 12592. 7. 19 Nos./25 Nos. of holes of 50mm to 60mm dia be provided on G.T. Cover circular/rectangular respectively and should not have sharp edge at top. 8. The grating cover shall be furnished smooth at top and bottom. 9. NDMC will have the right to inspect the manufacturer’s workshop of Authoirzed dealer of Manufacturers/Dealers/ Suppliers and casting process. 10. The firm should have his own well equipped casting workshop with testing facility and adequate for controlled concrete and curing etc. 11. The agency shall submit the manufacturing test certificate of all the items. 12. Steel fibres are used in addition to reinforcement and shall not be greater than 0.75mm and the aspect ration of fibres shall be in the range of 50 to 80 and minimum volume of fibres shall be 0.5% of the volume of concrete. 13. The following information shall be clearly and permanently casted/ engraved on the cover:- (i) Manufacturer Trade Mark of Name. (ii) Year of Manufacturing (iii) With words NDMC.
Sushma Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .